| 1 | L1₹25.7 CrAdmitted-Finance DORSIA HOUSE DAYING ERING COLONY P O P S ITANAGAR PAPUMPARE DISTRICT A P 79 111 | 79111 | ₹25.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹25.7 CrAdmitted-Finance | ₹25.7 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically not qualified |
| Sl No | Description | Qty | Unit | M/S GOOD WILL SUPPLIERS L2 | M/s Samco Construction Co. L1 |
|---|---|---|---|---|---|
| 1.00SH-1. SITE DEVELOPMENT | |||||
| 1.01 | Excavation in Hill Area in Soil by Mechanical Means (Excavation in soil in hilly area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with all lifts and lead upto 1000 metres)
All kinds of soil | 53,259.38 | Cum | 187 ₹99.6 L | 186 ₹99.1 L |
| 2.00SH-1. SITE DEVELOPMENT | |||||
| 2.01 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. | 5,504 | Cum | 281 ₹15.5 L | 281 ₹15.5 L |
| 2.02 | Excavation in Soil with Dozer with lead upto 100 metres ( Excavation for road way in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 metres (average lead50 metres), including trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections.) | 81 | Cum | 198 ₹16,038 | 198 ₹16,038 |
| 2.03 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
Pipes, cables etc, not exceeding 80 mm dia. | 115 | Mtr | 225 ₹25,875 | 225 ₹25,875 |
| 2.04 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. (qty from sanitary estimate) | 25 | Mtr | 417 ₹10,425 | 417 ₹10,425 |
| 2.05 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. | 4,141.95 | Cum | 128 ₹5.3 L | 128 ₹5.3 L |
| 2.06 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. | 217.82 | Cum | 4,120 ₹9.0 L | 4,120 ₹9.0 L |
| 2.07 | Supplying chemical emulsion in sealed containers including delivery as specified
a) Chlorpyriphos Emulsifiable concentrate 20% with 1% concentration.
'@' 1.0 ltr per sqm of covered area
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL | 1,451.15 | Cum | 200 ₹2.9 L | 200 ₹2.9 L |
Tender Value
₹25.7 Cr
EMD Value
₹25.7 L
Closing Date
28 Mar 2023, 12:00 pmClosed
Executive Engineer, Ziro Division, PWD, Ziro
Executive Engineer, Ziro Division, PWD, Ziro
Construction of A-1 type school building for Kendriya Vidyalaya at Ziro, Arunachal Pradesh
2023_PWDAP_1209_1
ZD/KV/2022-23/01
Open Tender
Civil Works - Building
1095 days
Ziro
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,000
EE PWD Ziro
₹25.7 L
Yes
Superintending Engineer, Yachuli Civil Circle, PWD
18 Apr 2023
22 Mar 2023
30 Mar 2023
22 Mar 2023
28 Mar 2023
22 Mar 2023
23 Mar 2023
Amount
SH-1. SITE DEVELOPMENT
Excavation in Hill Area in Soil by Mechanical Means (Excavation in soil in hilly area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with all lifts and lead upto 1000 metres) All kinds of soil
SH-1. SITE DEVELOPMENT
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Excavation in Soil with Dozer with lead upto 100 metres ( Excavation for road way in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 metres (average lead50 metres), including trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections.)
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Pipes, cables etc, not exceeding 80 mm dia.
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. (qty from sanitary estimate)
Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
Supplying chemical emulsion in sealed containers including delivery as specified a) Chlorpyriphos Emulsifiable concentrate 20% with 1% concentration. '@' 1.0 ltr per sqm of covered area Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: 2.35.2.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration (excluding the cost of chemical emulsion) :
CONCRETE WORK
Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: a) Foundations and plinth
Providing and laying damp proof course 50 mm thick with cement concrete 1: 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
Extra for providing and mixing water proofing material in cement concrete work in the proportion recommended by manufacturers.
Applying a coat of hot bitumen (mashphalte 80/100 or equivalent) using 1.70 Kg per Sq.m. on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. Perimeter of building as per plan on ground floor
RCC WORK
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All Works up to Plinth Level : Concrete of M25 grade with minimum cement content of 330 kg /cum All works above plinth level upto floor V level
Concrete of M25 grade with minimum cement content of 330 kg /cum
CENTERING & SHUTTERING
Centering and shuttering including strutting, propping etc. and removal of form for: a) Foundations, footings, bases of columns, etc. for mass concrete
b) Suspended floors, roofs, landings shelves and their supports , balconies and chajjas (3.5m Height)
c) Lintels, beams girders, bressummers and cantilevers etc
d) Columns, Pillars, Posts and Struts etc
e) Vertical and horizontal fins individually or forming box louvers bands and facias
f) Stairs (excluding landings) except spiral staircase
Providing and fixing sheet covering over expansion joints with iron screws as per design to match the colour / shade of wall treatment. Aluminium fluted strips 3.15mm thick.- 200 wide
STEEL REINFORCEMENT
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel
BRICK WORK
Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).
Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth.
Extra for providing and placing in position 2 nos. 6 mm dia. MS bars at every third course of brick half brick masonry (with FPS bricks).
ROOFING AND TERRACING
BRICK-BAT COBA:-Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations. a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water proofing compound conforming to IS : 2645 over the RCC slab including cleaning the surface before treatment. b) Laying cement concrete using broken bricks/ brick bats 25 mm to 100 mm size with 50% of cement mortar 1:5 (1 cement :5 coarse sand) admixed with proprietary water proofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with proprietary water proofing compound conforming to IS : 2645 to required slope and treating similarly the adjoining wall upto 300 mm height including rounding of junctions of walls and slabs. c) After two days of proper curing applying a second coat of cement slurry admixed with proprietary water proofing compound conforming to IS :2645 d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with proprietary water proofing compound conforming to IS : 2645 and finally finishing the surface with trowel with neat cement slurry and making of 300x300 mm square. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge. With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing gola 75 x 75 mm in cement concrete 1:2;4 ( 1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1 : 3 ( 1 cement : 3 fine sand) as per standard design :
Making khurras 45 x 45 cm with avg. minimum thickness of 5 cm cement concrete 1 : 2 : 4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1 mm x 1 m x 400 micron, finished with 12 mm cement plaster 1 : 3 ( 1 cement : 3 coarse sand) and finishing the outlet complete as per drawing.
RAIN WATER PIPES SYSTEMS
Providing and fixing on wall face unplasticised Rigid PVC Rain water pipes confirming to IS:13592 Type-A including jointing with seal ring confirming to IS: 5382 leaving gap for thermal expansion. (i) single socketed pipes 110 mm diameter
Providing and fixing unplasticised PVC pipes clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50 hard wood plugs, screwed with M.S.Screws of required length i/c cutting brick work and fixing in cement mortor 1:4(1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fitting/accessories for unplasticised - Rigid PVC Rain water pipes confirming to IS:13592 Type-A including jointing with seal ring confirming to IS: 5382 leaving gap for thermal expansion. Bend-87.5º 110 mm diameter Bend
Coupler 110 mm
shoe (plain- 110mm)
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
WOOD WORK
Providing and fixing flush door shutters, non-decorative type, core of black board construction with frame of 1st class hard wood and well matched commercial ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 40 mm thick including anodised aluminium butt hinges with necessary screws
Extra for providing vision panel not exceeding 0.1 Sq.m. in all types of flush door shutters (excluding cost of glass). a. Rectangular or square
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
Providing and fixing MS handles with necessary screws etc complete. a) 125 mm
Providing and fixing aluminium floor door stopper anodised ( anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws, etc. complete. Twin rubber stoper.
Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete. b) 250x10 mm
Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a) 250x16 mm
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. a) Plain grill.
Extra for providing lipping with second class teak wood battens 25 mm thick minimum depth on all edge of shutters ( overall area of door shall be meaured)
Supplying and fixing glass panes with wooden fillets including removal of broken glass panes and old wooden fillets wherever necessary but excluding cost of wooden fillets c) Frosted glass panes 2 mm thick and area 1 sqm each
FLOORING
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Raj Nagar plain
kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete with 1:4 cement mortar (1 cement :4 coarse sand) (in class rooms) 25 mm thick
Kota stone slabs 20mm thick in risers of steps, skirting, dado and pillars laid on 12mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Extra for nosing in steps and treads of kota stone slab
Providing and fixing 1st quality ceramic glazed wall tiles confirming to IS: 15622 ( thickness to be specified by manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any sizes as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 Cement : 3 Coarse sand) and joining with grey cement slurry @3.30kg per sqm including pointing with white cement mixed with pigment of matching shade complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours, shades, except White, Ivory, Grey, Fume Red Brown laid on 20mm thick bed of Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
STEEL WORK
Providing and fixing hand rail by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer ERW tubes
Providing and fixing T-iron frames for doors, windows and ventilators of MS Tee sections joints mitred and welded with 15 x 3 mm legs, 10 cm long embedded in cement concrete block 15 cm x 10 cm x 10 cm size of 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or bolt and nuts as required, including fixing of necessary butt hinges and screws and applying a priming coat of approved primer.
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top/centre hung with beading and all members such as K11 B and K 12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and shash bars tenoned and riveted including providign and fixing of hinges, pivots, including priming coat of approved steel primer, but , excluding the cost of other fittings, complete all as per approved design,(sectional weight of only steel members shall be measured for payement) a) Fixing with 15x3mm lugs 10 cm long embedded in cement concrete block 15x10x10cm of C.C. 1:3:6 (Cement: 3 Coarse Sand :6 Graded Stone Aggregate 20mm nominal size)
Extra for providing and fixing steel beading of approved shape and section with screw instead of glazing clips and metal sash putty in steel doors, windows, ventilators and composite units.
Providing and fixing oxidised MS casement stays (straight peg type) with necessary screws etc. complete. 300 mm weighing not less than 200 gms
Supplying and fixing glass panes with putty and nails including removal of broken glass panes where necessary b) Glass panes 3 mm thick and area 0.1 Sq.m. each
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately).
Providing and fixing Durashine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet roofing fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafters and trusses. Details of cost for 179.655 Sq.m.Laying and fixing 20 sheets in 3 row require Overall Sheet area of 20 x 3 x 3.05 x 1.072 plus 3% wastages = 202.061 Sqm After H & L laping as per manufacturer's specification, effective Area Measurable will be 20 x 3x 2.95 x 1.015 = 179.655 Sqm
Providing and fixing Durashine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet ridges fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafters and trusses. Details of cost for 11.75m Laying and fixing 4 lenths of 3.05m each require Overall length of 4 x 3.05 plus 3% wastages = 12.566m After laping as per manufacturer's specification, effective Measurable length will be (4 x 3.05) - (3 x 0.15) = 11.75
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification andalso including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with a. 12.5 mm thick tapered edge gypsum moisture resistant board
FINISHING
12 mm thk cement plaster 1: 3( 1 cement : 3 fine sand) on walls.
15 mm cement plaster 1:3 (1 cement :3 fine sand) on the rough side of single or half brick wall
15 mm cement plaster 1:3 with floating coat of neat cement in sunken portion 1:3 (1 cement :3 fine sand)
6 mm cement plaster to ceiling 1 : 3 (1 cement : 3 fine sand).
Applying one coat of cement primer of approved brand and manufacture on wall surface :
Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm overand including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Applying priming coat with ready mixed genuine red lead paint of approved brand and manufacture on steel work.
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
painting with synthetic enamel paint of approved brand and manufacture to give an even shade- 2 or more coats
Providing two coats of acrylic water based wall putty/wall filter of asian paints/Berger/dulux over concrete/cement plaster/brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ceilings surface with the help of emery stone,putty blade or wire brush,moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
WATER PROOFING
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with Armourcrete of M/s The Structural Water Proofing Company Pvt. Ltd. or Tapecrete of M/s CICO Engg. Service consisting of applying : ( a ) First layer of slurry of cement @ 0.488 kg/sqm mixed with Armourcrete or Tapecrete @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with Armourcrete or Tapecrete @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. / The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonary with polymer mixed slurry. Note: Rendering/plastering as protective layer, if required will be paid separately
ALUMINUM WORK
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.5 mm thickness (weight notless than 12.50 kg/sqm)
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-incharge Powder coated minimum thickness 50 micron aluminium
( A. Sanitary Installations )
Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required. b) Orissa Pattern WC Pan
Providing and fixing white vitreous china type water closet pedestal (European type WC pan) with seat and lid CP brass hinges and rubber buffers, 12.5 Litres high level CI flushing cistern with fittings RS or CI brackets, galvanized steel telescopic flush pipe with fittings and clamps, 20 GI overflow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting making good the walls and floors where required. a) WC pan with white plastic seat and lid.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x430x265 mm sizes respectively with CI automatic flushing cistern with fittings, RS or CI brackets standard size galvanized steel flush pipe and spreaders with brass unions and GI clamps complete including painting of cistern and fittings, cutting and making good the walls and floors where required. One urinal Basin with 5 litre CI automatic flushing cistern
Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. Flat back wash basin size 550x400 mm with a single 15 mm CP pillar taps of Heavy quality
Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe 265mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighting not less than 263 gms.
Providing and fixing laboratory sink including making all connections excluding cost of fittings a. white vitreous china sink Size 600 x 450 x 200mm
Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete. a. Semi rigid pipe
i. 32 mm dia
Providing and fixing 100 mm sand cast iron grating for gully ,floor ,or nahni trap.
Providing and fixing mirror of superior glass (of approved quality)and of required shape and size with plastic moulded frame approved make and shade with 6mm thk. Hard board backing. d. Rectangular shape 1500x450mm
Providing and fixing Toilet paper holder a. C.P Brass
( B. Waste pipes)
Providing and fixing soil, waste and vent pipes : a. 100 mm dia
Providing and fixing MS holder-bat clamps of approved design to Sand cast iron/ cast iron (spun) pipe embedded in and including cement concrete blocks 10 x 10 x 10 cm of 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) including cost of cutting holes and making good the walls etc. b. 100 mm diameter
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm a. Centrifugally cast (spun) iron S & S
Providing and fixing plain bend of required degree 100 mm Centrifugally cast (spun) iron S & S
Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
Providing and fixing single equal plain junction of required degree. a. 100 x 100 x 100 mm
Providing and fixing collar : Centrifugally cast (spun) iron S & S 100 mm
Providing and fixing terminal guard: 100 mm sand cast iron S&S
Providing lead caulked joints to sand cast iron / centrifugally cast (spun) iron pipes and fittings of diameter : 100 mm
Providing and fixing sand cast iron trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100mm inlet and 100 mm outlet
Painting sand cast iron / centrifugally cast (spun) iron soil, waste vent pipes and fittings with paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 100 mm diameter pipe
providing and fixing PTMT grating of approved quality and colour 100mm dia nominal size
( C. G I Pipes and Fittings)
Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good the walls etc. (internal work) Exposed on wall b. 20 mm dia nominal bore
c. 25 mm dia nominal bore
d. 32 mm dia nominal bore
e. 40 mm dia nominal bore
Concealed pipe including painting with anti-corrosive bitumastic paint, cutting chases and making good the wall 15 mm dia nominal bore
20 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work : 50 mm dia. nominal bore
65 mm dia. nominal bore
Providing and fixing brass gate valve with CI wheel of approved quality (screwed end) 25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
65 mm nominal bore
Providing and fixing ball valve (brass) of approved quality complete High or low pressure with plastic floats 25 mm nominal bore
Painting GI pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. c. 25 mm diameter pipe
Providing and fixing GI union in GI pipe including cutting and threading the pipe and making long screws etc. complete (new work) 25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Sub-Head : C . P. BRASS FITTINGS
Providing and fixing CP brass bib cock of approved quality conforming to IS : standards and weighing not less than 810 gms a. 15 mm Nominal bore
Providing and fixing CP brass stop cock (concealed) of standard design and of approved make conforming to IS : 8931 a. 15 mm Nominal bore
Providing and fixing CP brass angle valve for basin mixer and gyser points of approved quality conforming to IS : 8931 a. 15 mm Nominal bore
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. a. 15 mm nominal bore.
Sub-Head : Drainage System
Providing laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement in the proporation of 1:1(1 cement :1fine sand ) including testing of joints etc. complete. c. 200mm dia SW Pipes
Providing and laying cement concrete 1:5:10 (1 cement :5 coarse sand : 10 grade stone aggregate 40 mm nominal size) all-round S.W pipes including bed concrete as per standred design. 200mm diameter S.W pipe
Providing and fixing square-mouth SW gully trape grade 'A' complete with CI grating brick masonry chamber with bricks of class designation 75 and water tight CI cover with frame of 300 x 300 mm size (inside) the weight to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180 x 150 mm size P type With FPS bricks
Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design. a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg). with F.P.S brick with class designation 75
Extra for depth for manholes Size 120 v 90 cm
ELECTRICAL INSTALLATIONS A. POINT WIRING
Note :- Rates of only ISI marked conduits, cables, switches and socket outlets have to be taken in the following items. Unless and otherwise specified, only such conduits, cables, switches and socket outlets shall be used in the work. Wiring for light point /fan point /exhaust fan point /wall fan/call bell point with 1.5 sq. mm. FRLS PVC insulated, copper conductor single core cable in surface/recessed medium class PVC Conduite with piano type switch, phenolic laminated sheet, suitable size MS box and Earthing point with 1.5 mm FRLS PVC insulated copper conductor single core cable required: Group -B
Wiring for twin control light point with 1.5 sq. mm. PVC insulated, copper conductor, cable in recessed steel conduit, with 2 way, 5/6 amps, piano type switch etc. as required.
Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 no. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 no. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit / sub mains wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x2.5 sq.mm + 1x2.5 sq.mm earth wire.
4x10sq.mm + 2x10 sq.mm earth wire.
2x16 sq.mm + 1x16 sq.mm earth wire.
Supplying and drawing following pair 0.5mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 4 Pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required.
Supplying and fixing metal box of 150 mm x 75 mm x 60 mm deep ( nominal size ) on surfance or in recess with suitable size phenolic laminated sheet cover in the front including provinding and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connections, painting etc. as required. ( For light plugs to be used only in non- residential buildings).
Supplying and fixing metal box of 180mm x100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Supplying and fixing metal box of following size (nominal sizes) on surfance or in recess with suitable size phenolic laminated sheet cover in the front including painting etc. as required. ( For power plugs). 150mm x 75mm x 60mm deep
100mm x 100 mm x 60mm deep
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. Telephone socket outlet
TV antenna socket outlet
Bell push
Supplying and fixing of following sizes of medium class PVC conduit along with the accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required : 25 mm dia.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.
B. ERECTION OF FITTINGS
Rates of only ISI marked conduits, cables, switches and socket outlets have been taken in the following relevant items. Unless and otherwise specified, only such conduits, cables, switches and socket outlets shall be used in the work. Installation, testing and commissioning of prewired, flourescent fittings/ CFL of all types, complete with all accessories and tube etc. directly on ceiling/wall, including connections with 1.5 sq.mm. PVC insulated, copper conductor, single core cable etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down roads of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Numbering of ceiling fan/exhaust fan/air circulator/ flourescent fitting as required
Upto 450mm sweep.
Extra for fixing the louvers/shutters complete with frame for exhaust fans of all sizes.
Suppling and fixing extra down road of 10 cm. Length, G.I. pipe, 20 mm dia, heavy guage, including painting etc. as reqired. ( note more than 5 cm length shall be rounded off to the nearest 10 cm., and 5 cm. Or less shall be ignored.)
C. CABLES, MAINS AND SUB-MAINS
Supplying and making end terminations with brass compression gland for PVC insulated and PVC sheathed Aluminium Conductor cable of 1.1 KV grade of the following sizes as required including providing crimping heavy duty copper lugs 1.1 KV 4 x 16 sq. mm AYFY Cable
1.1 KV 3.5 x 95 sq. mm AYFY Cable
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface required. Upto 35 sq.mm (clamped with 1mm thick saddle).
D. SUPPLY OF CABLES, MAINS AND SUB-MAINS (Market Rate items)
Supply of following size of cables as per specifications mentioned in the Document eleswhere complete as required. 1.1 KV 4 x 25 sq. mm AYFY Cable (for main)
1.1 KV 4 x 16 sq. mm AYFY Cable (for sub mains)
Providing & laying in position hume pipes of following sizes in road crossings, paved areas etc., including collars, joints filled with cement mortar 1:4 (1 Cement: 4 Coarse sant) fini-shed neat and provided 75 mm thick cement concrete 1:3:6 (1 cement:Coarse sand:6 crushed stone aggregate 20mm and compacted and finished smooth complete. 150 mm dia Hume pipes
E EARTHING
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or coke and salt) complete as required.
Supplying and laying 25mm x 5mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt and spring washer spaced at 50mm).
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
F. SUPPLY OF LIGHTING FIXTURES & FANS (Market Rates Items)
Supply the following Lighting fixtures including lamps at site. Rate shall include all taxes and duties, transportation etc. complete. 1 x 40 watts Flourescent Light Fixture as per Bajaj Cat No. BJIE 136/140
2 x 40 watts Flourescent Light Fixture as per Bajaj Cat No. BJIE 236/240
12" dia (1400 r.p.m) Exhaust Fan with bird guard screen and gravity louvers complete.
48 " dia ( 1200 mm sweep ) ceiling fan .
G. FINAL DISTRIBUTION BOARDS - CPWD SOR
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
TPN RCCB: Supplying and fixing following rating, four pole, (three phse and neutral) 415 volts, residual current circuit breaker (RCCB) having a sensivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12) Double door.
Providing and fixing MV danger notice plate of 200 mm x 150 mm made of mild steel, atleast 2 mm thick, and vitreous enamelled white on both sides, and with inscription in signal red colour on front side as required.
H. MAIN PANELS & SUB DISTRIBUTION BOARDS Main Panel
Main school building Fire fighting Works A. Fire Hydrant System
S/L/J/T of following sizes of heavy grade “C” class galvanised iron pipe, flanges and fitting such as bends, tees, reducers,rubber insertions and galvanized nuts and bolts 'Heavy class' confirming to IS:1239-1974 Part-I and Part-II with upto-date amendment i/c fixing the pipe on wall/ceiling with suitable MS strip/clamps/bracket and painting with one coat of anticorrosive paint/primer and two or more coats of synthetic enamel paint etc. complete as required. c) 100 mm dia
Providing and fixing first aid fire hose reel equipment confirming to IS:884-1969 with up-to-date amendments finished with post office red spray paint and complete with following as required: a) 20 mm dia 40 mtr long hose tubing of DUNLOP make confirming to IS:5132-1969 with up-to-date ammendments. b) Swinging type hose guide fixing Bracket assembly. c) 20 mm dia globe valve, 20 mm dia GI (heavy class) piping upto 1 m Length duly painted, 5 mm outlet Gunmetal nozzle with shut offValve as required.
Providing and fixing 63 mm dia 15m long rubber lined woven jacketed hose including gunmetal male and female instantaneous type coupling approved by fire authority, machine wound with G.I. wire complete in all respects. Hose shall conform to I.S. 636 Type II and coupling to I.S. 903-1975 with ISI certification. (Two per hydrant station)
Providing and fixing standard short size gunmetal branch pipe with gunmetal nozzle 16 mm dia outlet with standard instantaneous type 63 mm dia coupling. Branch pipe and nozzle shall confirm to IS 903-1985.
Providing and fixing standard fireman's axe with heavy insulated rubber handle.
Providing and fixing C.I. double flanged sluice valve confirming to type PN 1.6 of I.S.780-1980 with C.I. wheel (right hand type with arrow head engraved or cast thereon showing the direction of turning open or close) and gunmetal seat, volts, nuts, washers and 3 mm thick insertion rubber gasket including painting complete. 100 mm dia Class-I
Providing and fixing cast steel double flanged horizontal type non return valves including nuts, bolts, 1.5 mm thick compressed asbestos gasket complete. 100 mm dia
Supply, installation, testing and commissioning of Down comer pump comprising of the following: Horizontally mounted centrifugal pump, suitable for operation on 415 volts ± 10%, 3 phase, 50 HZ A.C supply. Fire pump having C.I. body, bronze impeller and S.S. Shaft with mechanical seal, capable for deliverying 900 LPM of water at 35 mts. head. Complete with necessary pressure gauge with gun metal shut off cock and syphon on delivery side. The pump should meet the condition of Local fire Authority. Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase 50 HZ AC supply for the above pump with a synchronous speed of 2900 R.P.M. with flexible coupling and coupling guard etc. as required. Common base plate for (a) and (b) from M.S. channel as required size. Suitable cement concrete foundation with plaster, Antivibration arrangement of cushy foot mounting.
Providing, fixing, testing and commissioning of pressure vessel (minimum 450 mm dia & 1800 mm height) for pressurization of hydrant system complete with pressure switches, pressure gauge, valves at outlet / drain to operate as per operating sequences including 80 mm dia drain valve, air release valve with stop cock on the top Duly painted from inside and outside complete as required.
Providing and fixing signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+ -10%) containing lumigen II as base chemical, covered under UV stablized coating and of appropriate size (Glo-lite or eq. Make) including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats anchor fasteners etc. complete in all respacts as diercted by Engineer-in-charge.
Providing and fixing 4 mm thick glass door of size 1.0 m x 1.5 m with anodized aluminium frame of size 0.10 x 0.05 M with centre opening for fire hose cabinet. Suitably marked on the outside with the letters "FIRE HOSE" including locking arrangement. All aluminium work to be in Red P.O. colour. - FHC
Sub-Head : Hand Appliance
Supply & erection of ISI marked portable fire extinguishers, wall mounted type, wall brackets complete in all respect as per standard item with all accessories, delivery hose & nozzle whereever required, including fixing on walls as per the directions of Engineer-in-charge. (MAKE : Minimax / Cease Fire / Safex / Padmini / Newage) Water CO2 nozzle type. 9 Lt.capacity (IS:15683)
CO2 gas type. 4.5 kg. Capacity wheel type(IS:15683)
ABC dry powder stored pressure type 6 kg. capacity (IS:15683)
Supply & fixing of 4 nos. G.I. round bottom fire buckets of 9.0 liters capacity filled with sand including proper supporting / mounting arrangements in MS angle iron frame, painted by fire red colour over two coats of red oxide paint and written with white paint "FIRE" complete in all respects as per the directions of Engineer-in-charge.
SH-3. STAFF QUARTERS TYPE-II-4 Nos. EARTH WORK
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
CONCRETE WORK
Providing and laying in foundations and plinth cement concrete 1 : 3 : 6 (1 cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. a. Foundations and Plinth
Providing and laying damp proof course 50 mm thick with cement concrete 1: 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
Extra for providing and mixing water proofing material in cement concrete work in the proportion recommended by the the manufacutres.
Applying a coat of hot bitumen (mashphalte 80/100 or equivalent) using 1.70 Kg per Sq.m. on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth.
R.C.C. WORK
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All Works up to Plinth Level : Concrete of M25 grade with minimum cement content of 330 kg /cum All works above plinth level upto floor V level
Concrete of M25 grade with minimum cement content of 330 kg /cum
Add or deduct for plaster drip course/groove in plastered surface or moulding to RCC projection.
CENTERING & SHUTTERING
Centering and shuttering including strutting, propping etc. and removal of form for: a) Foundations, footings, bases of columns, etc. for mass concrete
c) Suspended floors, roofs, landings shelves and their supports , balconies and Chajjas
d) Lintels, beams, girders, bressummers and cantilevers etc
e) Columns, Pillars, Piers, Posts and Struts.
g) Stairs (excluding landings) except spiral staircase etc.
STEEL REINFORCEMENT
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel
BRICK WORK
Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).
Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth.
ROOFING AND TERRACING
Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or/and residual bitumen applied hot @ 1.45, 1.20 & 1.70 Kg. per Sq.m. of area respectively, second & fourth courses of roofing felt type-2 grade-I (fibre base self finished bitumen felt) and sixth and final course of stone grit 6 mm and down size or pea size gravel spread at 6 Cu.dm. per Sq.m. including preparation of surface excluding grading complete.
Providing gola 75 x 75 mm in cement concrete 1:2;4 ( 1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1 : 3 ( 1 cement : 3 fine sand) as per standard design :
Making khurras 45 x 45 cm with avg. minimum thickness of 5 cm cement concrete 1 : 2 : 4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1 mm x 1 m x 400 micron, finished with 12 mm cement plaster 1 : 3 ( 1 cement : 3 coarse sand) and finishing the outlet complete as per drawing.
WOOD WORK
Providing and fixing flush door shutters, non-decorative type, core of black board construction with frame of 1st class hard wood and well matched commercial ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 40 mm thick including anodised aluminium butt hinges with necessary screws
Providing and fixing MS handles with necessary screws etc. complete. a) 125 mm
Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete. b) 250 x 10 mm
Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. b) 250 x16 mm
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. b) Ornamental grill.
Extra for providing lipping with second class teak wood battens 25 mm thick minimum depth on all edge of shutters ( overall area of door shall be meaured)
Supplying and fixing glass panes with wooden fillets including removal of broken glass panes and old wooden fillets wherever necessary. c) Frosted glass panes 2 mm thick
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including aluminium butt hinges with necessary screws a) 38mm thick best available local wood class - B I
Providing and fixing 38 mm thick wire gauge shutters using galvanized mild steel wire gauge of IS gauge designation 140G with wire of dia 0.56 mm for doors, windows and clerestory windows including anodized aluminum butt hinges with necessary screws. a) Best available local wood class B-I
FLOORING
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete b). Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete b). Size of Tile 600 x 600 mm
Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete with 1:4 cement mortar (1 cement :4 coarse sand) 25 mm thick
Kota stone slabs 20mm thick in risers of steps, skirting, dado and pillars laid on 12mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Extra for nosing in steps and treads of kota stone slab
Extra for kota stone flooring in steps and treads not exceeding 30cm in width
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours, shades, except White, Ivory, Grey, Fume Red Brown laid on 20mm thick bed of Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing 1st quality ceramic glazed wall tiles confirming to IS: 15622 ( thickness to be specified by manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any sizes as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 Cement : 3 Coarse sand) and joining with grey cement slurry @3.30kg per sqm including pointing with white cement mixed with pigment of matching shade complete. Providing & fixing 18 mm thk. Gangsaw cut mirror polished premoulded and pre polished machine cut for kitchen plateforms, similar locations of required size of approved shades, colour and texture laid over 20 mm thk base cement mortar 1:4 (I cement: 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxi tiuchups,i/c rubbing, curing, moulding and polishing to edge to givr high gloss finish etc. complete at all levels. a). Udaipur green marble area of slab over 0.50 sqm
Providing & fixing 18 mm thk. Gangsaw cut mirror polished premoulded and pre polished machine cut for kitchen plateforms, similar locations of required size of approved shades, colour and texture laid over 20 mm thk base cement mortar 1:4 (I cement: 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxi tiuchups,i/c rubbing, curing, moulding and polishing to edge to givr high gloss finish etc. complete at all levels. a). Udaipur green marble area of slab over 0.50 sqm
Providing edge moulding to 18mm thk. Marble stone counters etc. i/c. machine polishing to edge to give high gloss finish etc. complete as per design approved by Engg-in-charge. Marble work
STEEL WORK & ROOFING
Providing and fixing hand rail by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer b ) ERW tubes
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately). b). In grating, frames, guard bar, laddrs, railing, brackets, gates and similaar works
FINISHING
12 mm thk cement plaster 1: 3 ( 1 cement : 3 fine sand) on walls.
15 mm cement plaster 1:3 (1 cement :3 fine sand) on the rough side of single or half brick wall
6 mm cement plaster to ceiling 1 : 3 (1 cement : 3 fine sand).
Wall painting (two or coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade
Applying priming coat with ready mixed genuine red lead paint of approved brand and manufacture on steel work.
Applying priming coat consisting of a mixture of red lead, white lead and double boiled linseed oil in the ratio of 0.7 Kg : 0.7 Kg : 1 Litre on wood work complete.
Painting two or more coats with synthetic enamel paint of approved brand and manufacture in black or chocolate shade on new work over and including an under coat of suitable shade with ordinary paint of approved quality to give an even shade.
Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade.
Applying Priming coat with ready mixedred oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works.
French spirit polishing (two or more coats) including a coat of wood filler on new work.
Providing two coats of acrylic water based wall putty/wall filler of Asian Paints/Berger/Dulex over concrete/cement plaster/brick walls and ceiling both internal and exterial after removing all the loosely adhering materials from the wall/ceiling suface with the halp of emery stone, putty blade or wire brush, moistering the wall with the help of sufficient quantity of water as specified and directed by the department.
WATERPROOFING
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with Armourcrete of M/s The Structural Water Proofing Company Pvt. Ltd. or Tapecrete of M/s CICO Engg. Service consisting of applying : ( a ) First layer of slurry of cement @ 0.488 kg/sqm mixed with Armourcrete or Tapecrete @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with Armourcrete or Tapecrete @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. / The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonary with polymer mixed slurry. Note: Rendering/plastering as protective layer, if required will be paid separately
Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or/and residual bitumen applied hot @ 1.45, 1.20 & 1.70 Kg. per Sq.m. of area respectively, second & fourth courses of roofing felt type-2 grade-I (fibre base self finished bitumen felt) and sixth and final course of stone grit 6 mm and down size or pea size gravel spread at 6 Cu.dm. per Sq.m. including preparation of surface excluding grading complete.
Providing and fixing 6mm thick Acrylic sheet to the back side of toilet door shutter with necessary screws and washers and edges to be saled with water replent compound and adhesives as per direction of Engineer-in-charge
Staff Quarters Type-II 4 Nos Electrification POINT WIRING
Note :- Rates of only ISI marked conduits, cables, switches and socket outlets have to be taken in the following items. Unless and otherwise specified, only such conduits, cables, switches and socket outlets shall be used in the work. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc., as required. Group C
Wiring for twin control light point 1.5 sq. mm.FR PVC insulated, copper conductor single core cable in surface/ recessed PVC conduit with 2 way piano type switch, phenolic laminated sheet, suitable size M.S.box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc. as required:
Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 no. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for power plug with 4 x 4 sq. mm. FR PVC insulated, copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 NOS. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x4 sq.mm + 1x4 sq.mm earth wire.
2x6 sq.mm + 2x6 sq.mm earth wire.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 wolts, complete as required.
Supplying and drawing following pair 0.5mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 4 Pair
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as requried. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
ERECTION OF FITTINGS
Rates of only ISI marked conduits, cables, switches and socket outlets have been taken in the following relevant items. Unless and otherwise specified, only such conduits, cables, switches and socket outlets shall be used in the work. Installation, testing and commissioning of prewired, flourescent fittings/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan and regulator, including wiring the down rod of standard length (upto 30 cm) with 1.5 sq.mm. PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and fixing extra down road of 10 cm. Length, G.I. pipe, 20mm dia, heavey guage, including painting etc. as required (note more than 5cm length shall be rounded off to the nearest 10cm and 5cm or less shall be ignored).
Numbering of ceiling fan/exhaust fan/air circulator/flourescent fitting as required
Installation of exhaust fan in the existing opening, including making good the damage, connections, esting, commissioning etc. as required. Upto 450mm sweep.
Extra for fixing the louvers/shutters complete with frame for exhaust fans of all sizes.
Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed steel/ PVC conduit as required.
SUPPLY CABLES, MAINS AND SUB-MAINS (mkt. Rate items)
Sub main wiring in PVC Conduit: Wiring for submain wiring along with earth wire with th following sizes of PVC insulated copper conductor, singl core cable in surface/ recess PVC conduit as required 4 x 25 sqm.
Providing & laying in position hume pipes of following sizes in road crossings, paved areas etc., including collars, joints filled with cement mortar 1:4 (1 Cement: 4 Coarse sant) fini-shed neat and provided 75 mm thick cement concrete 1:3:6 (1 cement:Coarse sand:6 crushed stone aggregate 20mm and compacted and finished smooth complete. 150 mm dia Hume pipes
EARTHING
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr. long etc.(but without charcoal or coke and salt) complete as required.
Supplying and laying 25mm x 5mm G.I. strip at 0.50 mtr. Below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
SUPPLY OF LIGHTING FIXTURES & FANS (mkt. Rates)
Supply the following Lighting fixtures including lamps at site. Rate shall include all taxes and duties, transportation etc. complete. 1 x 40 watts Flourescent Light Fixture as per Bajaj Cat No. BJIE 136/140
12" dia (1400 r.p.m) Exhaust Fan with bird guard screen and gravity louvers complete.
48 " dia ( 1200 mm sweep ) ceiling fan .
FINAL DISTRIBUTION BOARDS - CPWD SOR
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4+18), Double door
Providing and fixing MV danger notice plate of 200 mm x 150 mm made of mild steel, atleast 2 mm thick, and vitreous enamelled white on both sides, and with inscription in signal red colour on front side as required.
Staff Quarters Type-II 4 Nos Sanitary and plumbing
Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required. b) Orissa Pattern WC Pan
Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. Flat back wash basin size 550x450 mm with a single 15 mm CP pillar tap of heavy quality
Providing and fixing Stain stainless steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required 510 x 1040 mm bowl depth 250 mm
Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe 32 mm dia
Providing and fixing 100 mm sand cast iron grating for gully, floor / Nahani trap
Providing and fixing mirror of superior glass (of approved quality)and of required shape and size with plastic moulded frame approved make and shade with 6mm thk. Hard board backing. Rectangular shape 1500x450mm
Providing and fixing sand cast iron / cast iron(spun) soil, waste and vent pipes : 100 mm dia
Providing and fixing MS holder-bat clamps of approved design to Sand cast iron/ cast iron (spun) pipe embedded in and including cement concrete blocks 10 x 10 x 10 cm of 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) including cost of cutting holes and making good the walls etc. For 100 mm dia pipe
Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
Providing and fixing single equal plain junction of required degree.
Providing and fixing collar : Centrifugally cast (spun) iron S & S 100 mm
Providing lead caulked joints to sand cast iron / centrifugally cast (spun) iron pipes and fittings of diameter : 100 mm
Providing and fixing sand cast iron trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet
Painting sand cast iron / centrifugally cast (spun) iron soil, waste vent pipes and fittings with paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 100 mm diameter pipe
G I Pipes and Fittings
Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good the walls etc. (internal work) Exposed on wall 15 mm dia nominal bore
20 mm dia nominal bore
25 mm dia nominal bore
Concealed pipe including painting with anti-corrosive bitumastic paint, cutting chases and making good the wall 15 mm dia nominal bore
20 mm dia nominal bore
Providing and fixing brass gate valve with CI wheel of approved quality (screwed end) 25 mm nominal bore
Providing and fixing ball valve (brass) of approved quality complete High or low pressure with plastic floats 15 mm nominal bore
Painting GI pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 15 mm dia nominal bore
20 mm dia nominal bore
25 mm dia nominal bore
Providing and fixing GI union in GI pipe including cutting and threading the pipe and making long screws etc. complete (new work) 15 mm nominal bore
20 mm nominal bore
25 mm nominal bore
Providing and placing on terrace ( at all floor levels ) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
C . P. BRASS FITTINGS
Providing and fixing CP brass bib cock of approved quality conforming to IS : 8931 15 mm Nominal bore
Providing and fixing CP brass stop cock (concealed) of standard design and of approved make conforming to IS : 8931 15 mm Nominal bore
Providing and fixing CP brass angle valve for basin mixer and gyser points of approved quality conforming to IS : 8931 15 mm Nominal bore
Providing and fixing square-mouth SW gully trape grade 'A' complete with CI grating brick masonry chamber with bricks of class designation 75 and water tight CI cover with frame of 300 x 300 mm size (inside) the weight to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 With FPS bricks
Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design. a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg). with F.P.S brick with class designation 75
RAIN WATER PIPES SYSTEMS
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type-A, including jointing with seal ring conforing to IS:5382, leaving 10mm gap for thermal expansion, (i) Single Socketed pipes. 110 mm diameter
Providing and fixing MS holder-bat clamps of approved design to Sand cast iron/ cast iron (spun) pipe embedded in and including cement concrete blocks 10 x 10 x 10 cm of 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) including cost of cutting holes and making good the walls etc. 100 mm diameter
Providing and fixing on wall face unplasticised-PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type-A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion. 110 mm diameter bend
Providing lead caulked joints to sand cast iron rain water pipes and fittings: 100 mm dia pipe
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams.
SH-3. b) STAFF QUARTERS TYPE-III-4 Nos. EXCAVATION AND EARTH WORK
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
CONCRETE WORK
Providing and laying in foundations and plinth cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. 1:3:6( 1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) under floors.
Providing and laying damp proof course 50 mm thick with cement concrete 1: 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
Extra for providing and mixing water proofing material in cement concrete work in the proportion recommended by the the manufacutres.
Applying a coat of hot bitumen (mashphalte 80/100 or equivalent) using 1.70 Kg per Sq.m. on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth.
R.C.C. WORK
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All Works up to Plinth Level : Concrete of M25 grade with minimum cement content of 330 kg /cum All works above plinth level upto floor V level
Concrete of M25 grade with minimum cement content of 330 kg /cum
CENTERING & SHUTTERING
Centering and shuttering including strutting, propping etc. and removal of form for: a) Foundations, footings, bases of columns, etc. for mass concrete
c) Suspended floors, roofs, landings shelves and their supports , balconies and Chajjas
d) Lintels, beams, girders, bressummers and cantilevers etc
e) Columns, Pillars, Piers, Posts and Struts.
g) Stairs (excluding landings) except spiral staircase etc.
STEEL REINFORCEMENT
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel
BRICK WORK
Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).
Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth.
ROOFING AND TERRACING
Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or/and residual bitumen applied hot @ 1.45, 1.20 & 1.70 Kg. per Sq.m. of area respectively, second & fourth courses of roofing felt type-2 grade-I (fibre base self finished bitumen felt) and sixth and final course of stone grit 6 mm and down size or pea size gravel spread at 6 Cu.dm. per Sq.m. including preparation of surface excluding grading complete.
Providing gola 75 x 75 mm in cement concrete 1:2;4 ( 1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1 : 3 ( 1 cement : 3 fine sand) as per standard design :
Making khurras 45 x 45 cm with avg. minimum thickness of 5 cm cement concrete 1 : 2 : 4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1 mm x 1 m x 400 micron, finished with 12 mm cement plaster 1 : 3 ( 1 cement : 3 coarse sand) and finishing the outlet complete as per drawing.
WOOD WORK
Providing and fixing flush door shutters, non-decorative type, core of black board construction with frame of 1st class hard wood and well matched commercial ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 40 mm thick including anodised aluminium butt hinges with necessary screws
Providing and fixing MS handles with necessary screws etc complete. a) 125 mm
Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete. a) 250 x 10 mm
Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a) 250x16 mm
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. a) Ornamental grill.
Extra for providing lipping with second class teak wood battens 25 mm thick minimum depth on all edge of shutters ( overall area of door shall be meaured)
Supplying and fixing glass panes with wooden fillets including removal of broken glass panes and old wooden fillets wherever necessary. c) Frosted galss panes 2 mm thick
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including aluminium butt hinges with necessary screws a) 38mm thick best available local wood class - B I
Providing and fixing 38 mm thick wire gauge shutters using galvanized mild steel wire gauge of IS gauge designation 140G with wire of dia 0.56 mm for doors, windows and clerestory windows including anodized aluminum butt hinges with necessary screws. a) Best available local wood class B-I
FLOORING
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be pecified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete with 1:4 cement mortar (1 cement :4 coarse sand) 25 mm thick
Kota stone slabs 25mm thick in risers of steps, skirting, dado and pillars laid on 12mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Extra for nosing in steps and treads of kota stone slab
Providing and laying in Ceramic glazed floor tiles 300 x 300 mm (thickness to be specified by manufacturer) of 1st quality confirming to IS: 15622 of approved make in all colours such as white, ivory,grey ,fume red brown laid on 20 mm thick cement mortar 1:4 (1 cement :4 coarse sand) jointing with grey cement slurry @ 3.3 Kg/Sqm including pointing the joints with white cement and matching pigment etc. complete.
Providing and fixing 1st quality ceramic glazed wall tiles confirming to IS: 15622 ( thickness to be specified by manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any sizes as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 Cement : 3 Coarse sand) and joining with grey cement slurry @3.30kg per sqm including pointing with white cement mixed with pigment of matching shade complete.
Providing & fixing 18 mm thk. Gangsaw cut mirror polished premoulded and pre polished machine cut for kitchen plateforms, similar locations of required size of approved shades, colour and texture laid over 20 mm thk base cement mortar 1:4 (I cement: 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxi tiuchups,i/c rubbing, curing, moulding and polishing to edge to givr high gloss finish etc. complete at all levels. Udaipur greem marble - area of slab over 0.50 sqm
Extra for providing edge moulding to 18mm thk. Marble stone counters etc. i/c. machine polishing to edge to give high gloss finish etc. complete as per design approved by Engg-in-charge. Marble
STEEL WORK
Providing and fixing hand rail by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer ERW tubes 40mm nominal dia
steel work welded in build up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required. In grating, frames, guard bar, laddrs, railing, brackets, gates and similaar works
FINISHING
12 mm thk cement plaster 1: 3( 1 cement : 3 fine sand) on walls.
15 mm cement plaster 1:3 (1 cement :3 fine sand) on the rough side of single or half brick wall
6 mm cement plaster to ceiling 1 : 3 (1 cement : 3 fine sand).
White washing with whiting on new work (three or more coats) to give even shade.
Wall painting (two or coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade
Applying priming coat with ready mixed genuine red lead paint of approved brand and manufacture on steel work.
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
Painting two or more coats with synthetic enamel paint of approved brand and manufacture in black or chocolate shade on new work over and including an under coat of suitable shade with ordinary paint of approved quality to give an even shade
Finishing walls with premium acrylic smooth exterior paint with silicon additive of required shade New work (Two or more coats applied @ 1.43 ltr/10 sqm) over and including base coat of water proofing cement paint applied @2.20kg/10 sq
Applying one coat of cement primer approved brand and manufacturer on wall surface : Cement primer
French spirit polishing (two or more coats) including a coat of wood filler on new work.
Providing and applying plasteer of paris putty of 2.0 mm Thick over plastered surface to prepare the surfeace even and smooth complete
WATERPROOFING
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with Armourcrete of M/s The Structural Water Proofing Company Pvt. Ltd. or Tapecrete of M/s CICO Engg. Service consisting of applying : ( a ) First layer of slurry of cement @ 0.488 kg/sqm mixed with Armourcrete or Tapecrete @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with Armourcrete or Tapecrete @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. / The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonary with polymer mixed slurry. Note: Rendering/plastering as protective layer, if required will be paid separately
Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or/and residual bitumen applied hot @ 1.45, 1.20 & 1.70 Kg. per Sq.m. of area respectively, second & fourth courses of roofing felt type-2 grade-I (fibre base self finished bitumen felt) and sixth and final course of stone grit 6 mm and down size or pea size gravel spread at 6 Cu.dm. per Sq.m. including preparation of surface excluding grading complete.
Providing and fixing 6mm thick Acrylic sheet to the back side of toilet door shutter with necessary screws and washers and edges to be saled with water replent compound and adhesives as per direction of Engineer-in-charge.
STAFF QUARTERS TYPE-II 4 Nos. ELECTRICAL WORKS ELECTRICAL INSTALLATIONS SUB-HEAD : POINT WIRING
Note :- Rates of only ISI marked conduits, cables, switches and socket outlets have to be taken in the following items. Unless and otherwise specified, only such conduits, cables, switches and socket outlets shall be used in the work. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc., as required. Group C
Wiring fortwin control light point 1.5 sq. mm.FR PVC insulated, copper conductor single core cable in surface/ recessed PVC conduit with 2 way piano type switch, phenolic laminated sheet, suitable size M.S.box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc. as required:
Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 no. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for power plug with 4 x 4 sq. mm. FR PVC insulated, copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 NOS. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x4 sq.mm + 1x4 sq.mm earth wire.
2x6 sq.mm + 2x6 sq.mm earth wire.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 wolts, complete as required.
Supplying and drawing following pair 0.5mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 4 Pair
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as requried. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
SUB-HEAD: ERECTION OF FITTINGS
Rates of only ISI marked conduits, cables, switches and socket outlets have been taken in the following relevant items. Unless and otherwise specified, only such conduits, cables, switches and socket outlets shall be used in the work. Installation, testing and commissioning of prewired, flourescent fittings/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan and regulator, including wiring the down rod of standard length (upto 30 cm) with 1.5 sq.mm. PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and fixing extra down road of 10 cm. Length, G.I. pipe, 20mm dia, heavey guage, including painting etc. as required (note more than 5cm length shall be rounded off to the nearest 10cm and 5cm or less shall be ignored).
Numbering of ceiling fan/exhaust fan/air circulator/flourescent fitting as required
Installation of exhaust fan in the existing opening, including making good the damage, connections, esting, commissioning etc. as required. Upto 450mm sweep.
Extra for fixing the louvers/shutters complete with frame for exhaust fans of all sizes.
Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed steel/ PVC conduit as required.
SUB-HEAD : SUPPLY CABLES, MAINS AND SUB-MAINS
Sub main wiring in PVC Conduit: Wiring for submain wiring along with earth wire with th following sizes of PVC insulated copper conductor, singl core cable in surface/ recess PVC conduit as required 4 x 25 sqm.
Providing & laying in position hume pipes of following sizes in road crossings, paved areas etc., including collars, joints filled with cement mortar 1:4 (1 Cement: 4 Coarse sant) fini-shed neat and provided 75 mm thick cement concrete 1:3:6 (1 cement:Coarse sand:6 crushed stone aggregate 20mm and compacted and finished smooth complete. 150 mm dia Hume pipes
SUB-HEAD : EARTHING
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr. long etc.(but without charcoal or coke and salt) complete as required.
Supplying and laying 25mm x 5mm G.I. strip at 0.50 mtr. Below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
SUB-HEAD: SUPPLY OF LIGHTING FIXTURES & FANS
Supply the following Lighting fixtures including lamps at site. Rate shall include all taxes and duties, transportation etc. complete. a) 1 x 40 watts Flourescent Light Fixture as per Bajaj Cat No. BJIE 136/140
c)12" dia (1400 r.p.m) Exhaust Fan with bird guard screen and gravity louvers complete.
d) 48 " dia ( 1200 mm sweep ) ceiling fan .
SUB-HEAD : FINAL DISTRIBUTION BOARDS - CPWD SOR
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supplying and fixing following way prewired TP & N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) 6 way (4+18), Double door
Providing and fixing MV danger notice plate of 200 mm x 150 mm made of mild steel, atleast 2 mm thick, and vitreous enamelled white on both sides, and with inscription in signal red colour on front side as required.
STAFF QUARTERS TYPE-III 4 Nos.PLUMBING WORKS
Providing and fixing white vitreous china water closet squatting pan (Indian type WC pan) size 580 mm with 100 mm sand cast iron P or S trap, 12.5 litre high level C.I. flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanised steel telescopic flush pipe with fittings and clamps 20mm GI overflow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cisterns and fittings cutting and making good the walls and floors wherever required b. Orissa pattern WC pan of size 580 x 440 mm with integral type foot rests flush pipe and overflow arrangement
Providing and fixing white vitreous china wash basin with C.I./M.S. brackets, 15 mm CP brass pillar taps, 32 mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : Flat back wash basin size 550x450 mm with a single 15 mm CP pillar tap of heavy quality
Providing and fixing Stain stainless steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required a. Kitchen sink with drain board i. 510 x 1040 mm bowl depth 250mm
Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete. a. Semi rigid pipe i. 32 mm dia
Providing and fixing 100 mm sand cast iron grating for gully, floor / Nahni trap
Providing and fixing mirror of superior glass (of approved quality)and of required shape and size with plastic moulded frame approved make and shade with 6mm thk. Hard board backing. d. Rectangular shape 1500x450mm
Providing and fixing soil, waste and vent pipes : 100 mm dia
Providing and fixing MS holder-bat clamps of approved design to Sand cast iron/ cast iron (spun) pipe embedded in and including cement concrete blocks 10 x 10 x 10 cm of 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) including cost of cutting holes and making good the walls etc. b. For 100 mm dia pipe
Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
Providing and fixing plain bend of required degree a. 100 x 100 x 100 mm
Providing and fixing collar : Centrifugally cast (spun) iron S & S 100 mm
Providing lead caulked joints to sand cast iron / centrifugally cast (spun) iron pipes and fittings of diameter : 100 mm
Providing and fixing sand cast iron trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : a. 100mm inlet and 100 mm outlet
Painting sand cast iron / centrifugally cast (spun) iron soil, waste vent pipes and fittings with paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : b. 100 mm diameter pipe
G I Pipes and Fittings
Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good the walls etc. (internal work) Exposed on wall a.15 mm dia nominal bore
b.20 mm dia nominal bore
c.25 mm dia nominal bore
Concealed pipe including painting with anti-corrosive bitumastic paint, cutting chases and making good the wall 15 mm dia nominal bore
20 mm dia nominal bore
Providing and fixing brass gate valve with CI wheel of approved quality (screwed end) 25 mm nominal bore
Providing and fixing ball valve (brass) of approved quality complete High or low perssure with plastic floats 15 mm nominal bore
Painting GI pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. a.15 mm dia nominal bore
b.20 mm dia nominal bore
c.25 mm dia nominal bore
Providing and fixing GI union in GI pipe including cutting and threading the pipe and making long screws etc. complete (new work) 15 mm nominal bore
20 mm nominal bore
25 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
C . P. BRASS FITTINGS
Providing and fixing CP brass long nos bib cock of approved quality conforming to IS standards and weighing not less than 810 gms a. 15 mm Nominal bore
Providing and fixing CP brass stop cock (concealed) of standard design and of approved make conforming to IS : 8931 a. 15 mm Nominal bore
Providing and fixing CP brass angle valve for basin mixer and gyser points of approved quality conforming to IS : 8931 a. 15 mm Nominal bore
Providing and fixing square-mouth SW gully trapgrade 'A' complete with CI grating brick masonry chamber with bricks of class designation 75 and water tight CI cover with frame of 300 x 300 mm size (inside) the weight to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 With FPS bricks
Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design. a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg).
RAIN WATER PIPES SYSTEMS
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type-A, including jointing with seal ring conforing to IS:5382, leaving 10mm gap for thermal expansion, (i) Single Socketed pipes. 110 mm diameter
Providing and fixing M.S. Holder bat clamps of approved design of C.I. or S.C.I. pipes embedded in and including cement concrete block 10 cm x 10 cm x 10 cm of 1 : 2 : 4 mix (1 cement : 2 coarse sand: 4 stone aggregate 20mm nominal size) including cost of cutting holes and making good the wall etc. For 100 mm dia pipe
Providing and fixing on wall face unplasticised-PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type-A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion. 110 mm diameter bend
Providing lead caulked joints to sand cast iron rain water pipes and fittings: 100 mm dia pipe
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams.
TOTAL OF TYPE - III SH-3. C ) STAFF QUARTERS TYPE-V 1 Nos.
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
CONCRETE WORK
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) under floors.
Providing and laying damp proof course 50 mm thick with cement concrete 1: 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
Extra for providing and mixing water proofing material in cement concrete work in the proportion recommended by the the manufacutres.
Applying a coat of hot bitumen (mashphalte 80/100 or equivalent) using 1.70 Kg per Sq.m. on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth.
R.C.C. WORK
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All Works up to Plinth Level : Concrete of M25 grade with minimum cement content of 330 kg /cum All works above plinth level upto floor V level
Concrete of M25 grade with minimum cement content of 330 kg /cum
CENTERING AND SHUTTERING.
Centering and shuttering including strutting, propping etc. and removal of form for: a) Foundations, footings, bases of columns, etc. for mass concrete
c)Suspended floors, roofs, landings, balconies, shelves and access platform.
d) Lintels, beams, plinth beams, girders, bressummers and cantilevers.
e) Columns, Pillars, Piers, Abutments, Posts and Struts.
STEEL REINFORCEMENT
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel
BRICK WORK
Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).
Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth.
ROOFING AND TERRACING
Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or/and residual bitumen applied hot @ 1.45, 1.20 & 1.70 Kg. per Sq.m. of area respectively, second & fourth courses of roofing felt type-2 grade-I (fibre base self finished bitumen felt) and sixth and final course of stone grit 6 mm and down size or pea size gravel spread at 6 Cu.dm. per Sq.m. including preparation of surface excluding grading complete.
Providing gola 75 x 75 mm in cement concrete 1:2;4 ( 1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1 : 3 ( 1 cement : 3 fine sand) as per standard design :
Making khurras 45 x 45 cm with avg. minimum thickness of 5 cm cement concrete 1 : 2 : 4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1 mm x 1 m x 400 micron, finished with 12 mm cement plaster 1 : 3 ( 1 cement : 3 coarse sand) and finishing the outlet complete as per drawing.
WOOD WORK
Providing and fixing flush door shutters, non-decorative type, core of black board construction with frame of 1st class hard wood and well matched commercial ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 40 mm thick including anodised aluminium butt hinges with necessary screws
Providing and fixing MS handles with necessary screws etc complete. a) 125 mm
Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete. a) 250x10 mm
Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a) 250x16 mm
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. a) Plain grill.
Extra for providing lipping with second class teak wood battens 25 mm thick minimum depth on all edge of shutters ( overall area of door shall be meaured)
Supplying and fixing glass panes with wooden fillets including removal of broken glass panes and old wooden fillets wherever necessary. c) Frosted galss panes 2 mm thick
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including aluminium butt hinges with necessary screws a) 38mm thick best available local wood class - B I
Providing and fixing 38 mm thick wire gauge shutters using galvanized mild steel wire gauge of IS gauge designation 140G with wire of dia 0.56 mm for doors, windows and clerestory windows including anodized aluminum butt hinges with necessary screws. a) Best available local wood class B-I
FLOORING
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be pecified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand)including grouting the joint with white cement and matching pigments etc complete b. Size of Tile 600x600 mm
kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete with 1:4 cement mortar (1 cement :4 coarse sand) a. 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Extra for nosing in steps and treads of kota stone slab
Providing and laying in Ceramic glazed floor tiles 300 x 300 mm (thickness to be specified by manufacturer) of 1st quality confirming to IS: 15622 of approved make in all colours such as white, ivory,grey ,fume red brown laid on 20 mm thick cement mortar 1:4 (1 cement :4 coarse sand) jointing with grey cement slurry @ 3.3 Kg/Sqm including pointing the joints with white cement and matching pigment etc. complete.
Providing and fixing 1st quality ceramic glazed wall tiles confirming to IS: 15622 ( thickness to be specified by manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any sizes as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 Cement : 3 Coarse sand) and joining with grey cement slurry @3.30kg per sqm including pointing with white cement mixed with pigment of matching shade complete.
Providing & fixing 18 mm thk. Gangsaw cut mirror polished premoulded and pre polished machine cut for kitchen plateforms, similar locations of required size of approved shades, colour and texture laid over 20 mm thk base cement mortar 1:4 (I cement: 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxi tiuchups,i/c rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. a)Raj Nagar Plain with White marble/Udaipur green marble/Zebra black marble (Area of slab over 0.50 Sqm)
Extra for providing edge moulding to 18mm thk. Marble stone counters etc. i/c. machine polishing to edge to give high gloss finish etc. complete as per design approved by Engg-in-charge. Marble
FINISHING
12 mm thk cement plaster 1: 3 ( 1 cement : 3 fine sand ) on walls.
15 mm cement plaster 1:3 (1 cement :3 fine sand) on the rough side of single or half brick wall
6 mm thick cement plaster ( 1 cement : 3 fine sand) to ceiling.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade two or more coate on new work
Painting two or more coats with synthetic enamel paint of approved brand and manufacture in black or chocolate shade on new work over and including an under coat of suitable shade with ordinary paint of approved quality to give an even shade
Finishing walls with premium acrylic smooth exterior paint with silicon additive of required shade New work (Two or more coats applied @ 1.43 ltr/10 sqm) over and including base coat of water proofing cement paint applied @2.20kg/10 sq
Applying one coat of cement primer approved brand and manufacturer on wall surface : Cement primer
French spirit polishing (Two or more coats) including a coat of wood filler on new works
Providing two coats of acrylic water based wall putty/wall filter of asian paints/Berger/dulux over concrete/cement plaster/brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ceilings surface with the help of emery stone,putty blade or wire brush,moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
WATERPROOFING
Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or/and residual bitumen applied hot @ 1.45, 1.20 & 1.70 Kg. per Sq.m. of area respectively, second & fourth courses of roofing felt type-2 grade-I (fibre base self finished bitumen felt) and sixth and final course of stone grit 6 mm and down size or pea size gravel spread at 6 Cu.dm. per Sq.m. including preparation of surface excluding grading complete.
Providing and fixing 6mm thick Acrylic sheet to the back side of toilet door shutter with necessary screws and washers and edges to be saled with water replent compound and adhesives as per direction of Engineer-in-charge. All D2 door
ELECTRICAL INSTALLATIONS
Note :- Rates of only ISI marked conduits, cables, switches and socket outlets have to be taken in the following items. Unless and otherwise specified, only such conduits, cables, switches and socket outlets shall be used in the work. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc., as required. Group C
Wiring fortwin control light point 1.5 sq. mm.FR PVC insulated, copper conductor single core cable in surface/ recessed PVC conduit with 2 way piano type switch, phenolic laminated sheet, suitable size M.S.box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc. as required:
Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 no. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for power plug with 4 x 4 sq. mm. FR PVC insulated, copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 NOS. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x4 sq.mm + 1x4 sq.mm earth wire.
2x6 sq.mm + 2x6 sq.mm earth wire.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 wolts, complete as required.
Supplying and drawing following pair 0.5mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 4 Pair
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as requried. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
SUB-HEAD: ERECTION OF FITTINGS
Rates of only ISI marked conduits, cables, switches and socket outlets have been taken in the following relevant items. Unless and otherwise specified, only such conduits, cables, switches and socket outlets shall be used in the work. Installation, testing and commissioning of prewired, flourescent fittings/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan and regulator, including wiring the down rod of standard length (upto 30 cm) with 1.5 sq.mm. PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and fixing extra down road of 10 cm. Length, G.I. pipe, 20mm dia, heavey guage, including painting etc. as required (note more than 5cm length shall be rounded off to the nearest 10cm and 5cm or less shall be ignored).
Numbering of ceiling fan/exhaust fan/air circulator/flourescent fitting as required
Installation of exhaust fan in the existing opening, including making good the damage, connections, esting, commissioning etc. as required. Upto 450mm sweep.
Extra for fixing the louvers/shutters complete with frame for exhaust fans of all sizes.
Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed steel/ PVC conduit as required.
SUB-HEAD : SUPPLY CABLES, MAINS AND SUB-MAINS
Sub main wiring in PVC Conduit: Wiring for submain wiring along with earth wire with th following sizes of PVC insulated copper conductor, singl core cable in surface/ recess PVC conduit as required 4 x 16 sqm.
Providing & laying in position hume pipes of following sizes in road crossings, paved areas etc., including collars, joints filled with cement mortar 1:4 (1 Cement: 4 Coarse sant) fini-shed neat and provided 75 mm thick cement concrete 1:3:6 (1 cement:Coarse sand:6 crushed stone aggregate 20mm and compacted and finished smooth complete. 150 mm dia Hume pipes
SUB-HEAD : EARTHING
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr. long etc.(but without charcoal or coke and salt) complete as required.
Supplying and laying 25mm x 5mm G.I. strip at 0.50 mtr. Below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
SUB-HEAD : SUPPLY OF LIGHTING FIXTURES & FANS
Supply the following Lighting fixtures including lamps at site. Rate shall include all taxes and duties, transportation etc. complete. 1 x 40 watts Flourescent Light Fixture as per Bajaj Cat No. BJIE 136/140
12" dia (1400 r.p.m) Exhaust Fan with bird guard screen and gravity louvers complete.
48 " dia ( 1200 mm sweep ) ceiling fan .
SUB-HEAD: FINAL DISTRIBUTION BOARDS
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4+18), Double door
Providing and fixing MV danger notice plate of 200 mm x 150 mm made of mild steel, atleast 2 mm thick, and vitreous enamelled white on both sides, and with inscription in signal red colour on front side as required.
STAFF QUARTERS TYPE-V 1 Nos.PLUMBING WORKS
Providing and fixing white vitreous china water closet squatting pan (Indian type WC pan) with 100 mm sand cast iron P or S trap, 10 litre low level P.V.C. flushing cistern (of approved make) with fittings, C.I./M.S. brackets, 32 mm diameter flush pipe with fittings and clamps, overflow arrangement with specials and mosquito proof coupling of approved municipal design including painting of fittings and brackets, cutting and making good the walls and floors wherever required b. Orissa pattern WC pan of size 580 x 440 mm with integral type foot rests flush pipe and overflow arrangement
. Providing and fixing white vitreous china type water closet pedestal (European type WC pan) with seat and lid CP brass hinges and rubber buffers, 12.5 Litres high level CI flushing cistern with fittings RS or CI brackets, galvanized steel telescopic flush pipe with fittings and clamps, 20 GI overflow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting making good the walls and floors where required.
Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. a. Flat back Wash basin size 550x400mm with a pair of 15mm C.P. brass pillar taps of heavy quality
Providing and fixing Stain stainless steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required a. Kitchen sink with drain board i. 510 x 1040 mm bowl depth 250mm
Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete. a.Semi rigid pipe i. 32 mm dia
Providing and fixing 100 mm sand cast iron grating for gully floor or Nahni Trap
Providing and fixing mirror of superior glass (of approved quality)and of required shape and size with plastic moilded frame approved make and shade with 6mm thk. Hard board backing. d. Rectangular shape 1500x450mm.
Providing and fixing soil, waste and vent pipes : a. 100 mm dia
Providing and fixing M.S. Holder bat clamps of approved design of C.I. or S.C.I. pipes embedded in and including cement concrete block 10 cm x 10 cm x 10 cm of 1 : 2 : 4 mix (1 cement : 2 coarse sand: 4 stone aggregate 20mm nominal size) including cost of cutting holes and making good the wall etc. b. For 100 mm dia pipe
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. Centrifugally cast (spun) iron S & S 100 mm
Providing and fixing plain bend of required degree Centrifugally cast (spun) iron S & S 100 mm
Providing and fixing collar : Centrifugally cast (spun) iron S & S 100 mm
Providing lead caulked joints to sand cast iron / centrifugally cast (spun) iron pipes and fittings of diameter : 100 mm
Providing and fixing sand cast iron trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : a.100 mm inlet and 100 mm outlet
Painting sand cast iron / centrifugally cast (spun) iron soil, waste vent pipes and fittings with paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : b. 100 mm diameter pipe
G I Pipes and Fittings
Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good the walls etc. (internal work) Exposed on wall 15 mm dia nominal bore
20 mm dia nominal bore
25 mm dia nominal bore
Concealed pipe including painting with anti-corrosive bitumastic paint, cutting chases and making good the wall 15 mm dia nominal bore
20 mm dia nominal bore
Providing and fixing brass gate valve with CI wheel of approved quality (screwed end) 25 mm nominal bore
Providing and fixing ball valve (brass) of approved quality complete High or low perssure with plastic floats 15 mm nominal bore
Painting GI pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 15 mm dia nominal bore
20 mm dia nominal bore
25 mm dia nominal bore
Providing and fixing GI union in GI pipe including cutting and threading the pipe and making long screws etc. complete (new work) 15 mm nominal bore
20 mm nominal bore
25 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
C . P. BRASS FITTINGS
Providing and fixing CP brass bib cock of approved quality conforming to IS : 8931 a. 15 mm Nominal bore
Providing and fixing CP brass stop cock (concealed) of standard design and of approved make conforming to IS : 8931 a.15 mm Nominal bore
Providing and fixing CP brass angle valve for basin mixer and gyser points of approved quality conforming to IS : 8931 15 mm Nominal bore
Providing and fixing square-mouth SW gully trap class SP-1 complete with CI grating brick masonry chamber with water tight CI cover with frame of 300 x 300 mm size (inside) the weight to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 180 X 150 MM size P Type With FPS bricks
Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design. a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg).
RAIN WATER PIPES SYSTEMS
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type-A, including jointing with seal ring conforing to IS:5382, leaving 10mm gap for thermal expansion, (i) Single Socketed pipes. 110 mm diameter
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm diameter
Providing and fixing on wall face unplasticised-PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type-A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion. 110 mm diameter bend
Providing lead caulked joints to sand cast iron rain water pipes and fittings: 100 mm dia pipe
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams.
SH-4. CANTEEN E A R T H W O R K
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
C O N C R E T E W O R K
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) under floors.
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
Extra for providing and mixing water proofing material in cement concrete work in the proportion recommended by manufacturers
Applying a coat of hot bitumen (mashphalte 80/100 or equivalent) using 1.70 Kg per Sq.m. on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
REINFORCED CEMENT CONCRETE
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
. Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with M20 ( 1 cement: 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for : a) Foundations, footings, bases of columns, etc. for mass concrete
b) Suspended floors, roofs, landings shelves and their supports , balconies and chajjas (3.5m Height)
c) Lintels, beams girders, bressummers and cantilevers etc
d) Columns, Pillars, Posts and Struts etc
STEEL REINFORCEMENT
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel
B R I C K W O R K
Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).
Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth Cement mortar 1:4 (1 cement :4 coarse sand)
S T E E L W O R K
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces.
Supplying and fixing rolling shutters of approved make, made of 80 x 1.25 mm MS laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete but excluding the cost of the top cover and spring
Providing and fixing ball bearing for rolling shutters.
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
F L O O R I N G
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick.
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sum including pointing in white cement mixed with pigment of matching shade complete.
R O O F I N G
Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or/and residual bitumen applied hot @ 1.45, 1.20 & 1.70 Kg. per Sq.m. of area respectively, second & fourth courses of roofing felt type-2 grade-I (fibre base self finished bitumen felt) and sixth and final course of stone grit 6 mm and down size or pea size gravel spread at 6 Cu.dm. per Sq.m. including preparation of surface excluding grading complete.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete.
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diameter
Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Coupler- 110 mm
Single tee with door 110x110x110 mm
Bend 87.5° 110 mm bend
Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm
F I N I S H I N G
20 mm cement plaster 1:3 (1 cement : 3 fine sand)
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
White washing with lime on New work (three or more coats)to give an even shade:
Applying one coat of cement primer of approved brand and manufacture on wall surface
Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade
Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new work to give an even shade :
SANITARY INSTALLATIONS
Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. b) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality.
Providing and fixing kitchen sink including making all connection excluding cost of fittings. a) White glazed fire clay sink size 600x450x150 mm
Providing and fixing sand cast iron/cast iron(spun) soil, waste and vent pipes : a.75 mm diameter :
Providing and filling the joints with spun yarn cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 75 mm dia pipe
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 75 mm dia Sand cast iron S&S as per IS - 1729
Providing and fixing plain bend of required degree. 75 mm
Providing and fixing sand cast iron trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors a. 100 mm inlet and 75 mm outlet
WATER SUPPLY
Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). b.20 mm dia nominal bore
c. 25 mm dia nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore.
Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 20 mm nominal bore, 120 mm long. Weighing not less than 198 gms.
Providing and fixing square-mouth SW gully trape grade 'A' complete with CI grating brick masonry chamber with bricks of class designation 75 and water tight CI cover with frame of 300 x 300 mm size (inside) the weight to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 With FPS bricks
Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design. a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg).
Providing laying and jointing glazed stone ware pipe grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 150 mm diameter SW Pipes
Providing and laying cement concrete 1:5:10 (1 cement :5 coarse sand : 10 grade stone aggregate 40 mm nominal size) all-round S.W pipes including bed concrete as per standred design. b. 150 mm diameter S.W PIPE
SH-5. GUARD ROOM
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. All kinds of soil.
Providing and laying damp proof course 50 mm thick with cement concrete 1: 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) under floors.
Brick work with best available local bricks in foundations and plinth in cement mortar 1:6 (1 cement : 6 fine sand).
Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level
Providing and fixing T-iron frames to door of mild steel Tee-Section, joint mitred and welded with 15x3mm lugs 10 cm long embeded in cement concrete block 15x10x10 cm of 1:3:6 (1 cement:3 course sand:6 graded stone aggregate 20 mm nominal size)or with wooden plugs and screws or raw plugs and screwsor with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved primer.
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top/centre hung with beading and all members such as K11 B and K 12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and shash bars tenoned and riveted including providign and fixing of hinges, pivots, including priming coat of approved steel primer, but , excluding the cost of other fittings, complete all as per approved design,(sectional weight of only steel members shall be measured for payement) a) Fixing with 15x3mm lugs 10 cm long embedded in cement concrete block 15x10x10cm of C.C. 1:3:6 (Cement: 3 Coarse Sand :6 Graded Stone Aggregate 20mm nominal size)
Providing and fixing flush door shutters decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 40mm thick including anodised aluminium butt hinges with necessary screws.
12 mm cement plaster 1:4 (1 cement : 4 fine sand)
15 mm cement plaster on rough side of single or half brick wall 1:4 (1 cement : 4 Fine sand)
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel
Centering and shuttering including strutting, propping etc. and removal of form for: c. Suspended floors, roofs, landings, balconies and access platform.
kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete with 1:4 cement mortar (1 cement :4 coarse sand) (in class rooms) a. 25mm thick.
Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth.
White washing with lime to give an even shade : New work (three or more coats)
Applying one coat of cement primer of approved brand and manufacture on wall surface
Finishing walls with water proofing cement paint of approved brand and manufacturer and of required shade to give an even shade New work (three or more coats)
Applying priming coat with ready mixed genuine red lead paint of approved brand and manufacture on steel work.
Providing and fixing MS sliding door bolts bright finished or / and black enamelled, with nuts and screws etc. complete : 300 x 16 mm
Providing and fixing MS handles conforming to IS : 208 with necessary screws etc. complete : 125 mm
Providing and fixing MS tower bolts (barrel type) with necessary screws, etc. complete : 200 x 10 mm
Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or/and residual bitumen applied hot @ 1.45, 1.20 & 1.70 Kg. per Sq.m. of area respectively, second & fourth courses of roofing felt type-2 grade-I (fibre base self finished bitumen felt) and sixth and final course of stone grit 6 mm and down size or pea size gravel spread at 6 Cu.dm. per Sq.m. including preparation of surface excluding grading complete.
Providing gola 75 x 75 mm in cement concrete 1:2;4 ( 1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1 : 3 ( 1 cement : 3 fine sand) as per standard design .
Making khurras 45 x 45 cm with avg. minimum thickness of 5 cm cement concrete 1 : 2 : 4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1 mm x 1 m x 400 micron, finished with 12 mm cement plaster 1 : 3 ( 1 cement : 3 coarse sand) and finishing the outlet complete as per drawing.
SH-6. ENTRANCE GATE
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. 1:4:8 (1cement :4 coarse sand :8 graded stone aggregate 40mm nominal size)
Centing and shuttering including strutting, propping etc. and removal of form for : a. Foundations, footings, bases of columns etc. and mass concrete.
e. Columns, Pillars, Piers, Abutments, Posts and Struts.
R.C.C. WORK
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement a.M20 (1 Cement :1.5 Coarse Sand : 3 Stone aggregate 20mm nominal Size)
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel
Providing and fixing 1st quality ceramic glazed wall Tiles conforming to IS:15622(thickness to be specified by the manufacturer)of approved make,in all colours,shades except burgundy bottle green,black of any size as approved by Engineer in charge ,in skirting,risers of steps and dados,over 12mm thick bedof cement mortar1:3 (1 cement :3 Coarse sand) and jointing with grey cement slurry @3.3 Kg per Sqm including pointing in white cement mixed with pigment of matching shade complete
Steel work welded in build up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required. In grating, frames, guard bar, laddrs, railing, brackets, gates and similar works
SH-7. SEPTIC TANK 5 NOS. EXCAVATION AND EARTH WORK
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level. 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size)
R.C.C. WORK
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
FORMWORK
Centering and shuttering including strutting, propping etc. and removal of form for: c)Suspended floors, roofs, landings, balconies, shelves and access platform.
STEEL REINFORCEMENT
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel
BRICK WORK
Brick work with best available local bricks in foundations and plinth in cement mortar 1:6 (1 cement : 6 fine sand).
FINISHING
12 mm thk cement plaster 1: 3 ( 1 cement : 3 fine sand) on walls.
DRAINAGE
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft and SW drain pipe 100mm dia 1.80 m long complete as per standard design
SH-8. BOUNDARY WALL- .1040.00 Mtr
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering in footings and bases of columns (All work upto plinth level). 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4graded stone aggregate 20 mm nominal size.)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
R.C.C. WORK
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
CENTERING AND SHUTTERING.
Centering and shuttering including strutting, propping etc. and removal of form for: a) Foundations, footings, bases of columns, etc. for mass concrete
b) Lintels, beams, plinth beams, girders, bressummers and cantilevers.
c) Columns, Pillars, Piers, Abutments, Posts and Struts.
STEEL REINFORCEMENT
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel
BRICK WORK
Brick work with best available local bricks in foundations and plinth in cement mortar 1:3 (1 cement : 3 fine sand).
Extra for brick work with best available local bricks in superstructure above plinth level up to floor two leve
FINISHING
15 mm cement plaster 1:3 (1 cement :3 fine sand) on the rough side of single or half brick wall
12 mm thk cement plaster 1: 4 ( 1 cement : 4 coarse sand ) on walls.
Applying one coat of cement primer of approved brand and manufacture on wall surface
Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade
Applying priming coat with ready mixed genuine red lead paint of approved brand and manufacture on steel work.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade.
Steel Febrication work
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. b. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
SH-9.A. BASKET BALL COURT
SH-9.A. BASKET BALL COURT
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level. 1:4:8 (1cement :4coarse sand :8 graded stone aggregate 40mm nominal size)
Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. c) 75 mm thick
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in- Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
Marking on court by paint.
Basket ballstands
SH-9.B. VOLLEY BALL COURT
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level. 1:4:8 (1cement :4coarse sand :8 graded stone aggregate 40mm nominal size)
Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. c) 75 mm thick
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in- Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
Marking on court by paint.
Acrylic post & net etc.
SH-10 INTERNAL ROAD (Preparartion of Subgrade ) (Cost for 1.00 Km)
Preparation of sub grade (Preparation of sub grade by excavating earth to an average depth of 22.50 cm, dressing to camber and consolidating with road roller, making good the undulations etc. and disposal of surplus earth, lead upto 50 m.)
Granular Sub-base with Close Graded Material
By Mix in Place Method (Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mixin placemethod with rotavator at OMC ,and compacting with vibratory roller to achieve the desired density,complete as per clause 401) (i) for grading- I Material
(W.B.M. - III) (Cost for 1.00 Km)
Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density.) By Manual Means Grading- III (Using Screening Crushable type such as Moorum or Gravel) Using Screening Type-B (11.2mm Agg.)
( Black Topping)
Prime coat (Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.60 kg/sqm using mechanical means.)
Tack coat - Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 Kg per Sqm on the prepared bituminous/ granular surface cleaned with mechanical broom.
Open - Graded Premix Surfacing (Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or cut-back or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades.) Case - II: Open-Graded Premix Surfacing using cationic Bitumen Emulsion.
Seal Coat (Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B seal coats) Case - I : Type A
(SH: 11 STORM WATER DRAIN 300 X 450 mm)
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
CONCRETE WORK
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth
b) Walls including attached buttresses,pilasters and their caps and bases and strings courses etc upto floor two level
REINFORCED CEMENT CONCRETE
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Centring and shuttering including strutting, propping etc. and removal of form for : a) Foundations, footings, bases of columns, etc. and mass concrete.
b) Walls (any thickness) including attached pilasters,Buttresses,plinth and string courses etc
c). Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5m Height).
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel
12 mm cement plaster 1:3 ( 1 Cement: 3 Fine Sand)
Neat Cement Punning
(SH:12 HARD STANDING ) For 100.00 Sqm
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
Chequered terrazzo tiles 22 mm thick with marble chips of sizes upto 6mm in floors on 25 mm thick bed mortar 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete: c) Dark shade pigment using ordinary cement
(SH:13 TUBE WELL & PUMPS)
Boring/ drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in IS:2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of al equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, beyond 90 metre & upto 150 metre depth below ground level. 300mm dia IN Rockey strata i/c boulders
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia having minimum wall thickness 5.0 mm
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2mm) mild steel threaded and socketed/ plain bevel ended pipe (type -A) of required dia, conforming to IS:8110, of requted and approved make, having wall thickness not less than 5.40mm including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia
Development of tube well in accordance with IS: 2800 (part-I) and IS: 11189, to establish maximum rate of usable water yield without sand countent (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples and getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirment and direction of Engineer-in-charge.
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part-I), including necessary bolts & nuts of required size complete. 200mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part-I) 150 mm dia
Underground Sump
Underground Sump
Transporatation of boring Rig, accessories and ancillary equipments, materials etc. to the work site including removing the same after completion of works.
Supply, installation, testing and commissioning of 6HP submersible pump sets (5 stages to deliver 15,000 litres per hour at 55m head to be installed in 200/150mm dia deep tube well including 3 phase, 425 volts, 50Hz AC induction motor, water proof cable of required size and length, supporting clamps and other accessories but excluding the cost of all other electrical works like DOL starter, AC operated water level controller, incoming nswith fuse, on/off indicator, L.T. constrol cables and control panel board etc. which have been included in separate items under electrical works.
Supplying, installation, testing and commissioning of 2Hp submersible pump to deliver 20,000 lit/hr (pump to be installed for transferring water from underground tank to over head tank at 30m head including 3 phase 415 volts 50Hz AC induction motor and other accessories.
(SH: RCC Retaining Wall- 3.00 Mtr Height) EXCAVATION AND EARTH WORK
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Re Filling excavated earth in foundations & plinth etc. in 15 cm layer including ramming and watering etc complete
CONCRETE WORK
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) under floors.
Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in :
R.C.C. WORK
Reinforced cement concrete in retaining wall (any thickness) including attached pillasters, buttresses, plinth and string courses, fillets etc from top of foundation up to floor two level excluding cost of centring,shuttering and reinforcement in : a) M20 (1 cement : 1.5 Coarse Sand : 3 stone aggregate 20 mm nominal size).
CENTERING AND SHUTTERING.
Centering and shuttering including strutting, propping etc. and removal of form for: a) Foundations, footings, bases of columns, etc. for mass concrete
b) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc
STEEL REINFORCEMENT
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications.
(SH: Random Rouble Retaining Wall- 3.00 Mtr Height) EXCAVATION AND EARTH WORK
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material Ordinary soil Manual Means upto 3 m depth(Without dewatering)
CONCRETE WORK
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
STONE WORK
Stone masonry work in cement mortar 1:3 in foundation complete as drawing and Technical Specification Random Rubble Masonry
BACK FILLING
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification Granular material
WEEP HOLES
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications.
M/S GOOD WILL SUPPLIERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.71 MB
TechnicalbidDocument.pdf
Tender Documents • 3.27 MB
BOQ_1336.xls
BOQ • 0.85 MB
Download all tender documents and submit your bid