Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹37.9 LAccepted-AOC | 1 | Accepted-AOC Being lowest and reasonable rates | |
| 2 | 2₹38.8 L+₹86,430 (2.28%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | 2 | Rejected-Finance Not being lowest and reasonable | |
| 3 | 3₹39.9 L+₹2.0 L (5.35%)Rejected-Finance | 3 | Rejected-Finance Not being lowest and reasonable | |
| 4 | 4₹40.4 L+₹2.5 L (6.57%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | 4 | Rejected-Finance Not being lowest and reasonable | |
| 5 | 5₹44.6 L+₹6.7 L (17.7%)Rejected-Finance | 5 | Rejected-Finance Not being lowest and reasonable |
Tender Value
₹45.3 L
EMD Value
₹90,600
Closing Date
6 Dec 2019, 6:00 pmClosed
CWE(U)
HQ CWE(U) Delhi cantt
SPECIAL REPAIRS TO WATER SUPPLY PIPE LINE AT CERTAIN AREAS UNDER GE U WATER SUPPLY DELHI CANTT
2019_MES_268751_1
89034/CWE(U)/D-07/2019-20/E8
Open Tender
Civil Works - Water Works
Item Rate
120 days
Delhi Cantt
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Yes
GE U Water Supply
₹90,600
Yes
6 Jan 2020
20 Sept 2019
7 Dec 2019
20 Sept 2019
6 Dec 2019
23 Nov 2019
Amount
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep for pipe line/cable in soft/loose soil getting out and levelling of bottom surface to required level complete all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25Cum thick complete all as specified and as directed.
Removing excavated material from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point complete all as specified and as directed.
Taking down any type of old/unserviceable water pipes as actually obtained at site including all fittings with spigot & socket ends and lead/rubber tyton joints including burning out lead joints and recovering lead of the following size of pipe for depositing to MES store yard complete all as specified and as directed. :- Note:- Videography/ Photographic records shall be maintained during execution , retrieval of pipes,proper stacking & measurement .
(a) 100 mm bore
(b) 150 mm bore
(c) 200 mm bore
Supplying, Laying, jointing, testing and commmisioning of DI Pipe as per IS 8329 class K-7 with inside cement mortar lining with spigot and socketed ends laid in trenches complete all as specified and directed at site for the following sizes :-
(a) 100 mm bore
(b) 150 mm bore
(c) 200 mm bore
Material and Labour for CI fittings/specials such as Tees of any size and radius,bends, collars, tapers, tail pieces, caps and plugs up to 300 mm bore confirming to IS: 1538 complete all as specified and as directed.
Material and Labour for DI fittings/specials such as Tees of any size and radius,bends, collars, tapers, tail pieces, caps and plugs up to 300 mm bore confirming to IS: 9523 complete all as specified and as directed.
Material and labour for Run lead joint including jointing material for CI/DI pipe of following size/bore complete all as specified and as directed. :-
(a) 100 mm bore
(b) 150 mm bore
(c) 200 mm bore
Labour only for Run lead joint by using old lead and spun yarn for CI/DI pipe of following size/bore complete all as specified and as directed. :-
(a) 100 mm bore
(b) 150 mm bore
(c) 200 mm bore
Material and labour for Rubber Gasket Joint (Tyton Joint) including jointing material for DI/CI pipe of following size/bore complete all as specified and as directed. :-
(a) 100 mm bore
(b) 150 mm bore
(c) 200 mm bore
M&L Joints with rubber or fibre board gasket of sizes as under with nut,bolt and double washers complete all as specified and as directed.
(a) 100 mm bore
(b) 150 mm bore
(c) 200 mm bore
Supplying and fixing, jointing, testing of CI Sluice Valve of sizes as under , ISI Marked, flanged ends drilled pressure rating PN-1.0, Conforming to IS 14846, having stainless steel spindle with cast iron operation wheel at top including taking out unserviceable sluice valve and deoposited to MES Store yard complete all as specified and as directed. Note:- Flanged joints complete with jointing material shall be deemed to be included in the unit rate of this item.
(a) 100 mm bore
(b) 150 mm bore
(c) 200 mm bore
Taking up or down GI tubing and connections of the following sizes from trenches/wall/floor including cleaning for refixing or removal and depositing to MES Store yard complete all as specified and as directed. :-
(a) 15 mm bore
(b) 20 mm bore
(c) 25 mm bore
(d) 40 mm bore
(e) 50 mm bore
Supply & Laying tubing GI pipe medium grade ISI marked in trenches/wall/floor in old/new position including all fittings complete all as specified and as directed of following sizes :-
(a) 15 mm bore
(b) 20 mm bore
(c) 25 mm bore
(d) 40 mm bore
(e) 50 mm bore
Supplying & fixing gun metal gate valves with iron wheel head,screwed both ends for iron pipe, ISI Marked, as per IS: 778 of following sizes including taking out unserviceable gate valves and depositing to MES Store yard complete all as specified and as directed. :-
(a) 15 mm bore
(b) 20 mm bore
(c) 25 mm bore
(d) 40 mm bore
(e) 50 mm bore
M & L for construction of valves pit chamber having internal dimension 120cm x 120cm x 120 cm (internal height) using PCC (1:4:8)type D -2 40 mm graded stone aggregate for foundation 15 cms thick, 23 cm thick wall in CM (1:4), 10 mm thick rendering all around the brick work with 1:6 cement mortar PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame of size 40x40x6 mm , and comprising of 4 nos hold fast of size (25x3x150 mm )& hinges of size 100mm including 3mm thick MS top sheet cover with locking arrangement including 50 mm pad lock with double key with handle 6mm dia to open sheet,
including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primers including necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as specified and as directed and as shown on Drg No CWE(U) D-1/86 Sheet 1/1 forming part of tender documents .
M & L for making bore hole under road in hard/dense soil through trenchless technology by HDD (Horizontal direction method) incuding preparing and setting up the plant and equipment, preparing new pipe work like excavation shoring/strutting etc drilling, stringing, reaming and pulling back the new work on the path alignment proper disposal of drilling fluid and the ground penetrating radar survey to protect any existing utilites at the pipe installation location, restoration of site after completion
,all inclusive as per relevant IS and STT code of practice for trenchless technology suiting Indian condition for making horizontal bore of size 400 mm dia suitable for HDPE pipe insertion under road crossing/hard standing including HDPE pipe 300 mm nominal dia, 28.3 mm min wall thickness of grade PE 80 for protection of MS pipe to any depth complete all as specified and directed. Note: MS will be measured and paid separately
Supplying , laying , fabricating, welding & jointing, & testing MS Pipe of size 200 mm bore and 5 mm wall thickness confirming to IS 3589 passing through 300 mm bore HDPE pipe for trenchless / laid in trenches/floor complete all as specified and directed.
Vijay Electricals
Shivom Projects Private limited
Ashish Sehgal and Co.
Ridhi engineers and builders
V.K. Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .