Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC | ₹19.0 L Quoted ₹16.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹19.0 LRejected-AOC M 18 HOUSING BOARD UNIT MADAYANKUTTAI POST METTUR DAM 636 452 | METTUR DAM | SALEM | TAMIL NADU | 636452 | ₹19.0 L | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | BHARAKATH INDUSTRIES L1 | THIAGARAJAN ENGINEERING CONTRACTOR L2 |
|---|---|---|---|---|---|
| 1.00 | Cutting the worn out HRA side door bend tubes of tube dia 63.5x8mm edge preparation of the new & existing tubes, positioning the tubes with proper alignment, TIG and ARC welding the joint with IBR welder, cost of Argon gas, cutting gas, all consumables, T&P’s, hire charges for welding generator, TIG set and etc. | 172 | Nos of equivalent joints | 7,304 ₹12,56,288 | 8,000 ₹13,76,000 |
| 2.00 | Fin welding in-between of HRA side wall tubes to avoid air ingress from outside of boiler area including the cost of Welding electrode, all consumables, hire charges for welding generator & other T&P’s etc. | 288 | mtr | 923 ₹2,65,824 | 1,200 ₹3,45,600 |
| 3.00 | Removal of insulation double layer (60mm + 60mm = 120mm thick) from Boiler elevation and refixing after completion of rectification works. | 50 | sq.m | 2,712 ₹1,35,600 | 3,500 ₹1,75,000 |
Tender Value
Refer Docs
EMD Value
₹19,600
Closing Date
19 Dec 2025, 2:00 pmClosed
CE/ MTPS2
O/o. CE/ MTPS2
HRA Side Wall Man Hole Door
2025_EB_632137_1
OT 208 HRA Side Wall Man Hole Door
Open Tender
Maintenance Works
20 days
MTPS2
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹19,600
Yes
2 Feb 2026
15 Dec 2025
20 Dec 2025
15 Dec 2025
19 Dec 2025
15 Dec 2025
Cutting the worn out HRA side door bend tubes of tube dia 63.5x8mm edge preparation of the new & existing tubes, positioning the tubes with proper alignment, TIG and ARC welding the joint with IBR welder, cost of Argon gas, cutting gas, all consumables, T&P’s, hire charges for welding generator, TIG set and etc.
Fin welding in-between of HRA side wall tubes to avoid air ingress from outside of boiler area including the cost of Welding electrode, all consumables, hire charges for welding generator & other T&P’s etc.
Removal of insulation double layer (60mm + 60mm = 120mm thick) from Boiler elevation and refixing after completion of rectification works.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.