| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC | ₹26.4 L Quoted ₹26.5 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹27.1 L+₹63,669.30 (2.40%)Rejected-AOC | ₹27.1 L+₹63,669.30 (2.40%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹27.4 L+₹95,817.80 (3.62%)Rejected-AOC FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | ₹27.4 L+₹95,817.80 (3.62%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹28.6 L+₹2.1 L (7.97%)Rejected-AOC | ₹28.6 L+₹2.1 L (7.97%) | L4 | Rejected-AOC Rejected |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹33.2 L
EMD Value
₹67,000
Closing Date
25 Mar 2023, 5:00 pmClosed
GARRISON ENGINEER GOMANATAK
GARRISON ENGINEER GOMANTAK VASCO DA GAMA PIN 403802
Special repairs of AGS Stores House Bldg No P15 at MO Goa and Special Repair of Bldg No P42 Gun Garage at NCB Goa and Demolition and Reconstruction of Magazine Sentry Post at NCB Goa under GE Gomantak Vasco
2023_MES_583467_1
8502/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
VASCO DA GAMA
As per tender documents
8 documents required · 8 mandatory
₹500
GE GOMANTAK
₹67,000
Yes
28 Apr 2023
28 Feb 2023
27 Mar 2023
28 Feb 2023
25 Mar 2023
13 Mar 2023
Amount
Dismantling wrought iron or mild steel work of any description not otherwise provided
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates. Fe-410-W(Gde-E-250) quality-A).
Dismantling asbestos cement (corrugated, semi corrugated) sheets including ridges as in roof covering.
M&L for one coat of synthetic enamel paint to old steel surface over 10 cm width or girth incl preparartion of surfaces.
S&F Prepainted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified .
S&F fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall iffixed with L-type or J- type or cranked hook bolts in lieu of screw and all as specified and as directed.
Dismantling of false ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets.
S&F for anodised aluminium snap grid frame work for false ceiling with of size 605 x 605mm using main and cross tee of size 36.5mm x 25mm x 1.40mm, weighing 0.24 Kg/RM and 23.5mm x 26.4mm x 1.4mm weighing 0.19 Kg/RM respectively. The snap grid shall be supported at end all along the wall with aluminium anodised angle of size 40mm x 25mm x 2mm weighing 0.36 Kg/RM, the snap grid shall be fixed to ceiling supporting hanger consisting of approx 2mm dia GI wire
S&F Gupsum board of 12 mm thick for false ceiling 60cm x 60cm with staples on snap grid.
Taking down chowkhat or frames of door/ window / ventilators with shutter(Without taking off shutter from the frame) n.exc 1.50 m each.
Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) exc 1.50 m and n.exc 4.00 Sqm each.
S&F 2nd class H/W Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at junctions all as specified.
M&L for PCC type C1 1:3:6 (using 20 mm graded aggregate) for filling the holes of the hold fasts.
S& F MS flat iron 25 x 3 mm as in hold fast for fixing if chowkats.
S&F hard wood Plain, framed, panelled shutters (any number of panels), 35mm with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats.
M & L for two coat of synthetic enamel painting over one coat of pink primer incl new preperation of wooden surface over 10 cm width or girth.
M&L 18/19 mm thick pre laminated particle board, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screw to aluminium frame in repairs as partition.
S&F glazing with 4 mm thick sheet glass ordinary type including rubber beddings/gasket around glass panes n.exc 0.50sqm each all as specified.
S&F glazing with 5.5 mm thick sheet glass ordinary type including rubber beddings/gasket around glass panes exc 0.50sqm each all as specified.
S&F aluminium anodised wire mesh of size 1.5 mm x 3 mm mesh 20 Gauge thick of make M/S Kiran Netting or equivalent as approved by GE.
S&F aluminium anodised barrel tower bolt 200 mm, extruded section.
S& F aluminium anodised sliding door bolts with hasp and stapple extruded section or cast aluminium alloy 300 mm long.
S&F 100 mm butt hinges, medium weight cold rolled mild steel.
S&F aluminium handle cast type anodised 150 mm long.
M&l for plastic dividing strips,3mm thick and width of strip in 38mm flooring of slab work etc.
Chipping off existing loose, damaged concrete from RCC members of all affected RCC Columns, beams, slabs and chajjas on external and internal facades etc beyond main r/f.(if required in the opinion of the consultant), carefully with chisel and hammer including relieving structural members such as column, beam and slabs of their superimposed load partially or fully by provision of adjustable steel props, frames etc. Providing and applying "Rusticide SS' Rust passivator or equivalent as specified in the Brand names to existing r/f bars including wire brushing of r/f, cleaning, washing of concrete etc complete as directed. Providing and applying two coats of rust preventor slurry made out of "Polyalk Fixoprime" or equivalent as specified in the brand names and cement in proportion 1:1.5 to exising r/f bars as directed complete. Providing and applying bonding coat of slurry made out of "Polyalk EP" or equivalent as specified in the brand names and cement in proportion 1:1 to concrete and r/f substrates complete as directed. Providing and applying 'Polyalk EP' or equivalent as specified in the brand names. Polymer modified cement mortar in required porportion (1:5:15) to RCC members including hand packing, curing and making the surface rough for plastering.
Material & Labour for applying two coat of oil emulsion distemper on old surfaces of wall over a coat of primer perparation of surface by complete removal of distempered and painted surfaces complete.
Supply & Fixing for 1.25mm thickness of laths Steel Rolling shutters, without ball bearing gear oprated type with bevel gear box and crank handle as specified including top cover, anchoring rod,hasp and one shop coat of primer, erected in position as indicated,complete.
Removing building materials etc.to a distance of 1.00 Km beyond the lead included in the rates, including loading, unloading and stacking at the destination as directed.
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe 290 Gde- E-165)
M&L Erection fixing and fabrication roof trusses (framed trussed purlin, crane ganries, rails and fastening and heavy bracket framing )beam,tee,angle,channel or flat section ) including distance pieces cleats adjacent wall/column/ etc,
S&F Welded steel wire fabric (not exc 4 kg) sopplied and fixed complete to wood or steel membres.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
M&L pre-cast cement concrete block masonry Type C1 1;3;6 20mm graded aggregate with solid blocks, exc. 10 cm in width and setting in mortar 1:6, complete
Taking down cement plaster on brick work or stone walls including racking out joints ,hacking for key,scrubing down with water etc
Material & Labour for rendering in CM 1 : 6 ,10mm thickness on brick/cement/stone surfaces and finishes the surface even and smooth without using extra cement
Material & Labour for providing two coats of oil-bound distemper over a coat of alkali-resistand primer on new plastered surfaces wall including necessary preparation to surfaces complete all as specified and as directed
M/L for preparation of old decorated surfaces of walls including cornices, pillers etc and applying one coat of oil bound distempere, complete all as directed by Engr -in-charge.
Material & Labour for rendering in CM 1 : 4 (10+5)=15mm thickness on brick/cement/stone surfaces and finishes the surface even and smooth with out using extra cement including mixing with liquid WPC on top 5mm thick only Note :- Water proofing compound will be paid separately
Material & Labour two coats of acrylic emulsion extenior paint (anti fungal painting-APEX or Equivalent) over a coat of acrylic amulsion primer on new surface including preparation of surface of any description all as specified and directed by Engr-in-Charge.
Complete removal of existing treatment and M&L for providing two coats of acrylic emulsion extenior paint (anti fungal painting-APEX or Equivalent) over a coat of acrylic emulsion primer on old treated surface of any description including preparation of surface all as specified and directed by Engr-in-Charge.
Removing loose concrete/plaster upto sound stratum of ceiling ,chajjas, cloumns and beams and cleaned the slurface with water using water jet etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5mm thick plaster in CM 1:3 on fair faces of brick or concrete work finished even and smooth without using extra cement as in ceiling.
M&L for applying three coats of white wash on new surface of ceiling including preparation of plastered surface complete all as specified and directed.
M&L for applying one coats of white wash on old surface of ceiling including preparation of surface complete.
Taking down Steel doors exc 1.5 sqm not exc 4 sqm each (without taking off shutters from the frame)
Supply and fix of Steel rolling shutters (Thickness of laths in 1.00mm) , with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type but gear operated type with bevel gear box and crank handle complete all as specified and as directed.
M&L for preparation of new untreated steel surfaces of any description and applying two coats of Aluminium paint over a coat of primer.
Supply only Liquid water proofing compound (Dr Fixit IW+ or equivalent, 200ml per bag of cement).
Material & labour for cleaning of roof tops including removing the esixting treatment by brooming down with steel wire brushing scrapping down with steel scrapper and roughening the existing surfaces to receive plaster complete all as specified and directed by Engineer-in-Charge. Note : The drbris out the cleaning/removing/ scraping shall be removed out MD Land
Material and labour for provideing 10mm thick cement plaster over roof slab (over the area of dismantled roof treatment ) in CM 1:4 finished even and smooth without using extra cement (quoted rate shall inclussive of SBR latex)
Supply & Laying water proofing treatment using 4mm thick APP modified membrane consisting five layer membrane with features as specified, weighing not less than 4.0 kg per Sqm laid over a coat of cold applied bituminous primer @ 0.20 Kg per sqm by torching the membrane including sealing the over lap while torching with 100mm on length side and 100mm wide side as per manufactorer instuctions including joints and changes in direction the curved with cement mortar 1:3 mixed with SBR latex @ 200 Ml/bag of cment cured well before laying of membrance all as per manufacturer instructions and to the satisfaction of Engineer -in-charge including two coats of bituminous aluminium paint. Note (i) irrespective of lap the net covered area will only be measured for payment (ii) The quoted rate is deemed to beinclusive of primer APP membrane & SBR Latex.
Demolition cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness (below or above ground level)
Material & Labour for Cement concrete type B-1,1:2:4 (20mm graded) 100 mm thick PCC as in hard standing , ramp incl necessary form work etc complete.
Material & Labour for Spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green
M&L 75 mm thick cement concrete type C2 1:3:6 (40 mm graded aggregate) as in plinth protection,without using extra cement for finishing.
Dismantling Concrete in Roof slab,beam and similar work provided for cement concrete is reinforced (reinforcement cut as required to facilitate demolition) all as specified and directed by Engr in charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/disintegrated rock all as specified and as directed
M&L for Cement concrete (1:4:8) type D2 as in foundations, filling and mass concrete all as specified and as directed.
M&L for TMT bars 10mm dia & over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed
Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed
Use & waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar complete all as specified and directed
Use & waste of formwork to sides of pilars,posts, struts, piers, columns and stanchions, rough finished surfacdes of concrete all as specified
Formwork to sides and soffits of roof beams, beam haunchings, girders, bressummers, including supports, overhangs, etc. also splays between floors and beams, etc.complete all as specified and directed
Use & waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) all as specified and directed
M&L for RCC (1:2:4) (nominal mix) using (20mm graded stone aggregate) as in foundations footing, plinth beams, bases for columns and basement slab, under reamed piles and mass concrete complete all as specified.
M&L for RCC(1:2:4) (nominal mix) using (20mm graded stone aggregate) as in columns, pillars, posts & struts complete all as specified.
M&L for RCC (1:2:4) (nominal mix) using (20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified.
M&L for RCC (1:2:4) (nominal mix) using (20mm graded stone aggregate) as in roof slab supported on walls, beams and columns (Horizontal or sloping) complete all as specified.
M&L for Pre-cast cement concrete type C1 (1:3;6) block masonry with solid blocks, exc. 10 cm in width and setting in mortar (1:4) complete all as specified and as directed.
Returning, filling in , including, spreading, levelling, watering and well ramming in layers not exc 25cm thick soil complete all as specified and directed
Removing excavated materials (soft/dis integrated rockl) to a distance n.exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
M & L Hard core, broken to gauge n exc 63 mm for plinth protection/ under floor as directed by Engr in Charge.
M&L for PCC (1:4:8) type D-2 (using 40mm graded aggregates) as in sub base floor 75mm thick
M&L Non - skid colour Ceramic tiles 7 to 8 mm thick quare/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.16 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 20mm thick screed in CM (1:4) complete all as specified and directed.
M & L 15 mm thick rendering on fair faces of concrete in CM 1:6 finish the surface even & smooth without using extra cement complete all as specified and directed
M & L 15 ( 10+5) mm thick rendering in two layer on fair faces of concrete in CM 1:4 finish the surface even & smooth without using extra cement complete all as specified and directed ( NOTE : II nd coat 5mm thick with WPC )
M & L for rendering in CM 1:3, 10 mm thickness on roof slab finishing the surface even and fair with out using extra cement complete all as specified and directed.
S & F powder coated (50 micron) Aluminium window or ventilator shutter and frame any type (slidding or openable) with frame or other similar work etc section fabricated by using the JINDAL/ INDAL /HINDALCO /sections including necessary roller,wheel cleat handals locking arrangements also to receive 4.8mm thick glass with aluminum chanel beading and stainless steel scrw including and rubber gasket beading etc complete (the weight of rubber gasket beading will not be measured with the weight of aluminum shuter glass will be measured and paid separately)All scections as approved by GE
S&F 4.8 mm thick Sheet glass, ordinary quality and glazing with oil putty/rubber beading in square/Rectangular n exc 0.5 sq. m in each pane.complete all as specified and directed
S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed
Material and labour for applying two coats of cement base paint after and including complete removal of existing treatment of old plastered surfaces of walls complete all as specified and as directed.
S & F mild steel work like angle iron, flat iron etc in posts and struts in fencing incl cutting tops to shape as directed, drilling holes, notching for wire etc including all necessary drilling conforming to Fe 290 Gde E-165.
M&L for Two coats of synthetic enamel paint over one coat of primer including preparation of. new steel surfaces all as spcified and as directed.
Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Taking down carefully aluminium point wiring (light, fan, socket, bell or power) complete including all fittings and fixtures, removing, materials from site and making good disturbed surfaces of wall, ceilings etc.
M & L for point wiring complete with 1100 V grade PVC insulated and unsheathed multistranded 1.5 sqmm single FRLS core copper conductor cable drawn through and including PVC concealed conduit with all accessories including 1.5 sqmm PVC insulated and unsheathed FRLS copper conductor cable as earth continuity wire all as specified for one light, fan, 5 Amps socket outlet in same board, etc and making good disturbed surface of walls and floors to match with existing surfaces.
All as per item No 2 but 2/3 pin socket out let 5 Amps with 1.5 Sqmm on independent board.
All as per item No 2 here-in-before but for 2 in 1 three pin socket outlet 15/20 Amps on independent board with 4 Sqmm cable FRLS copper conductor multistranded including 4 sqmm PVC insulated and unsheathed FRLS copper conductor cable as earth continuity wire all as specified and directed by Engr-in-Charge.
Supply & Fixing modular switch 1 way 6A, 1 module, 230 volts.
Supply & Fixing modular switch one way 16 Amps, 1 module, 230 volts.
Supply & Fixing modular socket 6 Amps-2/3 pin combined, 2 module.
Supply & Fixing modular socket 6A/16A-2/3 pin combined, 2 module.
Supply and fix ceiling rose surfaces bakelite 65 x 50 mm three terminals including supply and fix PVC plate or square blocks.
Supply & Fixing stepped type 2 module modular electronic fan regulator flush type including removal of old one.
Supply & fixing MCB, 6 to 32 Amps, single pole, C Series, 10 KA, 240 volts.
Supply & fixing MCB, 6 to 32 Amps, single pole neutral, C Series, 10 KA, 240 volts.
Supply & Fixing sheet metal enclosure DB, 8 way, SPN, double door factory made powder coated including neutral and earth link connector flush fixed in wall complete including dismantling of old one complete all as specified and directed.
Supply and fixing LED tube light fitting surface and wall mounted batten with 20 watts LED having minimum 100 lumens/watts and with integrated electronic driver complete made up of aluminium housing complete all as specified and directed.
S & F LED Bldg Security Street light 30W ,IP 65 with suitable surge protection device including suitable size of GI pipe 1.2 m long bent to required shape,clamps,nut ,bolts and making electrical connection to the fitting with Suitable size of service wire.
Supply & Fixing submain wiring with 2 Runs of 4 Sqmm, PVC insulated, unsheathed, single core, multi stranded, 1100 volts, FRLS copper conductor cable drawn in and including PVC conduit concealed with all accessories as required along with 1 run of 4 sqmm PVC insulated, unsheathed, single core, multi stranded copper conductor cable as continuous earth wire and connecting to existing main switch board/Distribution Board and testing on completion all as directed by Engineer-in-Charge.
Supply and fixing Earth continuity conductor or main earthing lead of 16 sqmm PVC insulated copper conductor drawn in through concealed steel conduit/pipe and connecting from existing earthing to Distribution box complete.
Supply & fixing brushless direct current (BLDC) ceiling fan 1200mm sweep (ISI Marked), 230 volts, 26 Watt includung connection rod as per existing size of length of GI pipe medium grade including dismantling of old one and depositing in MES store yard as per specified and directed by Engr-in-Charge. Make : Orient/Havells/Bajaj
Supply & fixing exhaust fan 300mm sweep, heavy duty, 230 volts including louvers of suitable size and dismantling of old one depositing in MES store yard as per specified and directed by Engr-in-Charge. Make : Orient/Havells/Bajaj
M/L for earthing complete with steel earth plate eletrode 60cm x 60cm x6mm thick buried dirctly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plat not less than 1.5 mtr below ground level connected to GI wire 4 mm dia by means of bolts. nuts,check nuts and washers etc including protection pipe 15mm dia up to 7.5m length , provision the earth lead to earth connection in ther main distribution box with lugs and GI nuts,bolts, earthing shall be done all as per shown electrical plate No 5 of SSR part 1 Including neccessary excavation disintergrated hard rock filling earth of 15 mm thick and privision of earth pit provision of 20mm dia eith funel PCC earth chamber 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing in presence of Engr-in-Charge.
Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in hard/dense soil .
Supply and fix for DWC high density polyethylene pipes having dia 50mm having outer side wall corrugated and inner surface plain confirming to IS 14930 (Part-I & II) including straight/bend couplers to join two pipes for protection of underground cable laid in trenches/floor/fixed on pole/wall including all fittings and clamps as required complete all as specified and directed.
Supply and Laying UG LT cable XLPE insulated armoured heavy duty 1100 volts grade with aluminium conductor multistandarded including centre gland, lugs, jointing materials etc laid in trenches or fixed it to wall cable of following size 10 sqmm 2 core complete all as specified.
M & L for sand cushion in trenches for cable protection complete all as directed and specified.
Supply and lay PCC cable cover class LV type I flat size 250mm x150mmx40mm with ISI mark.
Supply & fixing UG LT cable XLPE insulated armoured heavy duty 1100 volts grade with aluminium conductor multistandardedof size 25 sqmm 3.5 core including centre gland, lugs, jointing materials etc laid in trenches or fixed it to wall and taking down old unserviceable cable.
Supply and laying GI Pipe light grade of 40 mm dia laid in trenches or fixed in walls complete all as specified and directed.
STAR FABRICATION
M/S jvsr constructions
M/s RAJ CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .