Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹28.5 L+₹1.3 L (4.87%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹30.1 L+₹2.9 L (10.5%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹31.1 L+₹3.9 L (14.5%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹33.1 L+₹5.9 L (21.7%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹37.8 L
EMD Value
₹75,600
Closing Date
4 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAMS
GE NAMS AMRITSAR
SPL REPAIR TO BLDG NO P-120 (OR MD ACCN) AT PALERAM ENCLAVE OF 3 JAKLI AT NAMS
2022_MES_550383_1
GE NAMS-57/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE NAMS
CLASS D CATEGORY a(i) b(i)
8 documents required · 8 mandatory
₹500
GE NAMS
₹75,600
Yes
15 Nov 2022
6 Sept 2022
6 Oct 2022
6 Sept 2022
4 Oct 2022
20 Sept 2022
Amount
Taking down shutters of any description exc. 1 sqm and not exc. 2 Sqm each, complete all as specified.
Material and Labour glazed skeleton shutter for door 35mm thick 2nd class hard wood (Hollock) open rebated prepapred to receive glass, guage etc ( without sash bars) edges of framing plain, chamfered or rounded,fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I Section 8 Clause 8.24(a) complete all as specified and directed.
S&F 35mm thick 2nd class hard wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats complete all as specified.
S & F butt hinges 100 mm size medium weight cold rolled mild steel (zinc chromate coating) (ISI marked) complete all as specified and directed.
S & F 150 mm mild steel barrel tower bolts stove enamelled black (ISI marked) and fixed complete.
S & F 150 mm mild steel pressed handle, oval type, stove enamelled and fixed complete.
S&F 250mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified.
M & L for two coats of synthetic enamel paint over one coat of pink primer on new wooden surfaces exceeding 10cm width or girth including preparation of surface complete.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe 410-W (Gde-E-250) quality-A, complete all as specified and directed by Engr-In-Charge.
Material and Labour for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. complete all as specified and directed by Engineer-in-charge.
S & F 150 mm aluminum anodised barrel tower bolts of extruded sections and fixed complete.
S & F 150mm aluminum handles, cast type, anodised etc complete all as specified.
S&F floor door stopper of aluminium alloy body and tongued,anodised,with hard drawn steel spring,fixed complete all as specified and directed.
Material & labour for box type steel window 1.25 mm thick made of ERW tube P-Section of size 60 x 25 mm double rebated outer frame comprise of glazed skeleton shutter (two gauged shutters and two glazed shutter) of ERW tube P-Section size 50 x 20 mm and 1mm thick one/two Nos openable leaf consisting of two Nos sash bar of T-Section 20x3mm welded to frame with one No Vertical mullion of ERW box type T-Section of size 60 x 25 mm and 1.25 mm thick and FI 2 mm thick welded / screwed to frame for fixing of glass including fittings and fixture like Handle, Tower Bolt, stopper, cleat, pintal hinges, hold fast etc. (a) Hold Fast, 150mm long of 120mm x 3 mm made to shape -04 Nos per window. (b) Handle of Z sec 20mm x 25mm, 100 mm long -1 No per leaf (c) MS Tower bolt 150mm long - 2 No per leaf (d) Z Sec 20mm x 25 mm, 100 mm long stopper - 1 No per leaf (e) Cleat 55 mm long of hollow square 15mm x 20mm x.63mm welded to hinge -1 No per leaf. (f) MS Pintal hinges of size 75mm x 12mm - 2 Nos per leaf (g) 8 mm square guard bar, 10 cm centre to centre. (h) 25x4 mm flat iron all around for joint of both frame. (j) Two coat of red oxide primer to MS window and guard bar Note: Including taking down old steel window and making good dismantled portion with PCC 1:2:4 type B0 including hold fast PCC (four No’s for Each window) & around required plaster in CM 1:4 and match with existing finishing complete all as specified and directed by Engineer-in-charge.
Material and Labour for Box type steel ventilator made of ERW tube P-section of size 60mmx25mm outer frame ( single rebated), comprises glazed shutter, frame of ERW tube and FI 2mm thick welded/screwed to frame for fixing of sheet glass including fixture and fittings like as Stopper, Cleat, Pintal hinges, holdfast etc all as shown on drg No CEJZ/TD1019/08 sheet 1/3 to 3/3 dt 01 May 2008 complete all as specified. (a)10mm Sq Guard bar 10Cm C/C (b)Two coat of red oxide primer to MS window and guard bar Note: Including taking down old steel window and making good dismantled portion with PCC 1:2:4 type B0 including hold fast PCC (four No’s for Each ventilator) & around required plaster in CM 1:4 and match with existing finishing complete all as specified and directed by Engineer-in-charge.
M&L for two coats of synthetic enamel paint on new steel surface exc 10 cm width or girth on one coat of primer (Red oxide) incl preparation of new surfaces complete.
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples.
Supplying and fixing 3mm thick ordinary sheet glass and glazing with oil putty or fixed with wooden beading, in squares not exc 0.50 Sqm in each panes complete all as specified.
Supply and fixing 3mm thick figured glass pin head type and glazing with oil putty in squares not exc 0.50sqm in each pane complete all as specified and dircted.
Taking down cement plaster from wall/ceiling including raking out joints hacking for key scrubbing down with water complete all as specified and dircted.
M&L for 10mm rendering in cement mortar (1:6) on fair face of brick/concrete surfaces finished the surface even and smooth without using extra complete all as specified and dircted.
M&L for rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish even and fair (w/o using extra cement) incl WPC as per user manual complete all as specified and directed. (WPC shall be measuared seperatly and @ 200ML for 50kg cement bag or as per manufacturer's instructions).
M&L for 10mm rendering in cm (1:3) on ceiling surfaces finished the surfaces even and smooth without using extra cement complete all as specified and directed.
Material and Labour for preparation of new plastered surfaces and applying two coats of oil bound distemper over a coat of primer of chalk whitening on walls complete all as specified and directed by Engr-In-Charge.
Material and Labour for preparation of new plastered surfaces and applying two coats of cement base paint on wall complete all as specified.
Material and Labour for preparation of newly plastered surfaces and applying three coats of white wash on ceiling complete all as specified.
Supply only liquid WPC complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for non skid ceramic any coloured/printed tiles 7 to 8 mm thick (square/rectangular ) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm as in floor of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles, over 15mm thick rendering as screed bed in cement mortar (1:4) in floors, complete all as specified and directed.
All as per item 29.00 above but area of each tile exe 0.11 sqm but n.exe 0.18 sqm, in floors & skirting etc complete all as specified and directed.
M&L for glazed ceramic coloured/printed/ dark tiles size 300x200mmx7mm thick on vertical surface in skirting /dado ,set and jointed in neat cement slurry and pointed with white cement with pigment to match the colour of tiles, 10 mm thick rendering on fair faces of concrete surface of verticle in CM (1:3) finished even and smooth without using extra cement complete, shade & design as approved by EIC/GE, all as specified and directed.
Supply and fxing in replacement of rotational moulded polythene water storage tank, white coloured, tripple layer cylindrical vertical with closed top 500 litre capacity hoisted and fixed in position, including inlet and outlet pipe connections, 20mm dia and 15 mm dia GI pipes medium grade respectively, 20mm GI pipe medium grade over flow pipe 15 cm long wash out with plug and brass ball valve 20mm, high pressure with polyethelyne float and fly nuts complete all as specified and directed.
S & F in repair Bib taps, cast copper alloy, chromium plated, fancy type, long body with crutch or butterfly handle, screwed down, screwed for iron pipe of 15mm bore and fixed complete with all fittings all as specified and directed.
S & F in repair Stop cock concealed long shank chromium plated fancy type 15 mm bore screwed down high pressure with crutch or butter fly handle complete all as specified and directed.
S & F in repair Angle cock CP fancy type 15 mm bore screwed down high pressure with crutch or butterfly handle & screw both end for iron pipe or for Unions complete all as specified and directed.
S&F in repair for 125 mm size chromium plated shower roses with arm length not less than 150mm with swivel joints, any size including fixing to steel pipe or union complete all as specified and directed.
S&F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
Supplying and fixing in repairs PVC valve less syphonic action type low level flushing cistern of 10 ltrs capacity with inlet ball valve, float valve, push button type handle including 32mm dia of PVC (Heavy duty) flush pipe including brackets complete all as specified.
S & F in repair for vitreous china squating pan of (Orissa Pattern) size 580 x 440 mm white with 'P' or 'S' trap front or back inlet and integral foot rest (excluding flushing cisteern and flush pipe) fixed incl cement concrete bedding as required set complete all as specified and directed.
S&F for PVC connections 45cm long superior quality with PTMT nut on both side complete all as specified and directed.
S&F in repair sinks made of stainless steel 1 mm thick kitchen or laboratory with drainage board of size 915 x 460 mm with plugs, washers and wastes; incl bedding in cement mortar on to dwarf wall or including fixing cantilever brackets of angle iron 50x50x6mm and connecting union to pipe, overall size 915mmx460mm bowl size 410mmx330mmx160mm fixed complete all as specified.
S&F in repair stainless steel plate rack overall size 900 x 750 x 250mm, weight not less than 7.00 kgs for each, made out of 0.63mm thick stainless steel sheet as per standard pattern fixing to walls with screwed complete all as specified.
S&F in repair PVC waste pipe 32mm bore with socket (superior quality) complete all as specified.
S&F in repair CP grating 125mm dia round fix on floor/nahani trap fixed in repair with cement mortar 1:3 complete all as directed complete all as specified.
S&F in repair 18/19 mm prelaminated particle board, prelaminated both side with decorative choice lamination & other side balancing white lamination, as in cupboard shutters fixed with screws to timber/steel frame work (incl 2 Nos 100mm aluiminium handles, 1 Nos 100mm hasp & staples for each cupboard) complete all as specified and directed.
S&F 30mm width of flaps (when open) continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified and directed.
M&L for green marble 15-18 mm thick over cement screed bed laid on 15 mm thick CM 1:4 and jointed with grey cement slurry mixed with pigment ot match the shade of the slab / staircase / steps,riser incl rubbing and polishing incl moulding rounding to edge of marble & dismantling of old marble incl disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed by the EIC., complete all as specified and directed.
Supply and fixing powder coated mild steel curtain rods 20mm dia including, brackets to hold the rod & a set of ABS finials ( as per sample kept in GE's office) of approved quality & appropriate qty of ABS plastic rings complete all as specified .
S&F in repair 15mm bore Stop valve cast copper alloy screwed down high pressure with crutch or butter-fly handle, screwed both ends for iron pipes or for union, fixed, complete all as specified.
S&F in repair 20mm bore Stop valve cast copper alloy screwed down high pressure with crutch or butter-fly handle, screwed both ends for iron pipes or for union, fixed, complete all as specified.
Taking up or down steel water tubings and connections of 15 mm bore pipe including cleaning for re-fixing or removal to store, complete all as specified and directed.
Taking up or down steel water tubings and connections of 20 mm bore pipe including cleaning for re-fixing or removal to store, complete all as specified and directed.
Taking up or down steel water tubings and connections of 25 mm bore pipe including cleaning for re-fixing or removal to store, complete all as specified and directed.
S&F Steel water tubing of 15 mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified.
S&F Steel water tubing of 20 mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified.
S&F Steel water tubing 25mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches, complete all as specified.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed by the EIC. complete all as specified and directed.complete all as specified and directed.
Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified.
All as per ser item No 59.00 here in before but except brick
Dismantling of brick tiles or terracing tiles, single layer on roofs, complete all as specified and directed.
Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) and diposing the rubbish to a distance exceeding 500 mtr, complete all as specified and directed.
M&L 50mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in roof padding, haunching, sub base of floor etc, incl WPC as per user manual complete all as specified and directed. (WPC shall be measuared seperatly @ 200ML for 50kg cement bag or as per manufacturer's instructions).
M&L for preparation of roof surface and applying evenly a tack coat of industrial bitumen primer 85/25 grade @ 1.2 Kg/Sqm including APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application, joints to be touched hot and width of overlaps not less than 150mm complete all as specified. Note: Treatment to be carried out by Company approved applicator
S&F in repair for 110mm bore PVC (SWR) bends any radius with access door complete all as specified and directed. .
S&F stack clamps out of 50 mm x 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100mm bore pipe complete all as specified and directed. .
S&F in repair 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
M&L for PCC 1:4:8, type D-2 (using 40mm graded crushed aggregate) as in concrete bed to drain pipes 110mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; complete all as specified and directed.
S&F for PVC (SWR) branch piece, double (double Y) equal or unequal for 110mm dia pipe complete all as specified and directed. .
S&F PVC (SWR) floor trap, plain with grating including jointing to waste pipe with solvent cement, dia of outlet 75mm, complete all as specified.
S&F PVC (SWR) gully trap 110mm, setting and jointing with solvent cement, complete all as specified.
S&F PVC (SWR) vent cowl of size 110mm bore, complete all as specified.
M&L 75 mm thick cement concrete (1:3:6), type C-1 using 20mm graded stone aggregate as in plinth protection and laid in panels complete and finished the even & fair and providings joints through out the thickness of plinth protection filed with mastic filling comprising one part of 01 bitumen 85/25 grade and three part of sand by weight incl dismantling / demolition and disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed by the EIC., complete all as specified and directed.all as specified and directed.
M & L for 75mm thick PCC 1:4:8 type D-2 (using 20 mm agg. ) in sub base of flooring incl demolition, disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed by the EIC. complete all as specified and directed.
M & L for chequered tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling and disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed by the EIC., complete all as specified and directed.
M & L for repair to RCC Chajjas, roof projection edges, hanging part of chajjas, edges of chajjas, RCC parapets, under the roof / floor slabs with RCC 1:2:4 (using 12.5mm crushed stone graded agg) incl necessary renforcement 8mm to 12mm TMT bars, form work, MS wire mesh for bounding the concrete on ground required and plaster work in CM 1:3 & periodical services to match with the existing surfaces finishing at any height of buildings etc complete all as specified and directed by Engr-in-Charge.
Taking down aluminium/copper point wiring from existing conduit / batten (light, fan, socket or power) complete such as switches, ceiling rose, pendent, regulators, socket, light fittings etc and removing material from site and making good the disturbed surface of wall / floor etc, complete all as specified and directed
M&L for point wiring with 1.5 sqmm (Nominal area ) 1100 Volt PVC Insulated , FRLS unsheathed and multi stranded copper conductor cable in old PVC Concealed conduit for one light / fan point or bell point controlled by one switch (including cutting chases and making good the distributed surfaces) and fixing new 3mm thick plastic laminated sheet top cover, sheet screws and 1.6mm thick GI sunken boxes after removing old unserviceable plastic laminated sheeet and sunken boxes included 1.5 Sqmm stranded copper conductor with green PVC Insulation earth contunity conductor connected to common earth dolly etc . complete all as specified and directed Note : The cost of sunken boxes and bakellite sheet is included in the quoted rate)
All as per Srl item No 78.00 above but for one 5 amps socket outlet independent complete all as specified.
All as per Srl item No 78.00 above but on the same board complete all as specified
All a per item No 78.00 above but with 2.5 Sq mm size cable multi stranded FRLS copper wire unsheathed for one 3 pin socket outlet 15 Amps on independent board including continuous earth wire of PVC insulated 1.5 Sq mm copper solid conductor connecting to common earth dolly complete.
Supply and fixing of switch piano type 6 Amps one way 230 volts AC complete all as specified and as directed.
Supply and Fixing of socket outlet 5 pin, 6 Amps flush type 230 volts AC complete all as specified and as directed
Supply and Fixing of switch piano 16 Amps type one way 230 volts AC complete all as specified and as directed
Supply and Fixing of socket outlet 6 pin 6/16 Amps multi purpose flush type 230 volts AC complete all as specified and as directed
Supply and Fixing of switch type regulator 5 step 230 volts AC complete all as specified and as directed
Supply and fixing of ceiling rose 65/50 mm two to three terminals complete all as specified.
Supply and fix of MCB 40 Amps single pole with neutral, AC 230 Volts complete all As specified and directed.
Supply and fix of MCBs single pole (SP) 5 to 32 Amps with 10 KA breaking capacity of 'C' series in distribution boards complete all as specified and directed.
Supply and fixing in replacement Sheet metal enclosure for DB's when MCB's to be used single door factory made flush fixed complete with 200 Amps rated busbar 240 Volts single phase 8 ways complete all as specified
Supply and fix in replacement for sub main wiring with two run of single core (FRLS) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area 6.0 Sqmm drawing into and including PVC non metallic rigid conduit medium grade of adequate size and making electric connections including one run (FRLS) PVC insulated single core copper conductor cable 6.0 Sqmm as a earth continuity conductor(green colour) and including non metallic medium grade rigid PVC conduit, including cutting chases in brick wall, and making good to match the existing specifications complete all as specified and directed by Engineer-in-Charge. Note :- (i) Rates are deemed to be included cutting and making holes in wall/floor for passing in or through conduit (ii) Two run of 6.00 sqmm single core (FRLS) PVC insulated copper conductor cable, one run of 6.0 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of suitable size will be measured as a one unit.
all as per item No 91.00 above but for 4.0 sqmm
Material and labour of lamp holder insulated body with 9 Watt LED Bulb, back plate batten/angle type for batten fitting fixed on bakelite sheet 100mmx100mm 230V AC cool day light 6500K having maximum height 1020 mm heavy duty complete all as specified. make:- havells/ssk/cona/indo asian/legrand/anchor
S & F in repairs, installation, commissioning and testing Polycarbonate ASTA CPRI approved OEM made Meter Panel including cutting the wall to make concealed including cement plaster work and color wash to match with existing. The Panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4:Meter Panel (Mini. Size 600 x 600 x 170 ) Wall Mounted type on Mounting Structure RAL 7016. The Meter Panel should be anti-acid, anti corrosive & Fully Transparent Door for meter Vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of his CPRI TEST REPORTS with Short Circuit Test of POLYCARBONATE only , also share panel assemble by OEM, channel partner or sister concerned assembly will not accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane and Enclousers make Hensel/Clipsal. The manufacturer of panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current –
Rated peak, short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits and submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel should passed glow wire test 960oC in accordance with 60695-2-11 [flame retardant and self-extinguishing. One Main Incomer MCCB 100A TP 25KA Thermal /Magnetic Release with spreader link. MCCB/MCB Nob Operated by Flip Cover. Indicator Provided on each phase. Provision of Four Nos Single Phase Sub-Meters in Panel. Provided Output supply by MCB DP 40Amp 4 Nos. Meter Enclosures & Enclosures Accessories as per RAL 7035. Ten Nos Terminal Blocks Provided for output Supply all as specified and as directed. Make- Hensel/Rittal/Emitter/Schneider/ABB. NOTE:- Rates of main incomer MCCB 100 AMP and MCB DP 40 AMP 4 Nos is included in quoted rate and no extra paymentwill be made for it.
Supply and fix exhaust fan, steel body single phase 230V of size 300 mm sweep with blades, frame and louvers all as specified and directed.
Supply and fixing of LED T-8 tube light fitting with sinle side connection LED tube rod 18/20 W, 4 Feet made of CRCA sheet steel box type including bipin holder and connection with PVC insulated twin core 23/0.0076 ywisted copper cable from ceiling rode to light fitting complete all as specified and directed.
Supply & fix LED Street Light Luminaire 25 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens all as specified and as directed.
Supply and fixing of security light mounting bracket made out of GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of pole fitting clamps made out of MS flat of size 40 x 6 mm and nuts and bolts and painting with aluminium paint, all as direced by Engr in Charge
Supply, laying in trenches or wall and testing in replacement of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade ) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PART 1 , with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switche, DBs) complete all as specified & testing on completion.
Excavation in trenches not exceeding 1.5m wide & not exceeding 1.5m in depth and getting out in any type of soil all as specified and as directed.
Returning, filling including spreading, leveling, watering and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of surplus excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
Supply,laying & fixing in replacement double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc.. all as specified and directed by Engr in Charge of size 63mm outer dia and 50 mm inner dia.
Supply and lay on wall/ floor etc GI pipe light grade of dia 32 mm for protection of cable all as specified and directed.
Taking down ceiling fan/geyser/exhaust fan in situ and refixing after servicing, repairing and painting them, scratching old paint and preparation of surface for painting with one coat of white / grey enmeled paint and including cable from ceiling rose to fan complete all as specified and as directed.
Taking down old meter and refixing them in new meter panel and make necessary connection to bus bar and MCB DPs in meter panel all as specified and as directed.
S & F of decorative wall light fixture made up of polycarbonate , suitable for and including 9 W retrofit LED lamp B22 base all as specified and as directed.
S & F in replacement of single pole and neutral sheet metal enclosures with two pin & earth plug and socket complete with one singlr pole MCB of 20 amps complete all as specified and as directed.
trenchless boring under the road with the help of trenchless boring machine without damaging the road horizontally for the road crossing and laying of GI tubing (to be measured and paid seperately) of any size for cable protection complete all as specified and as directed.
Supply and fixing in replacement of bell push 6 amps one way 230 volts AC complete all as specified and as directed.
Supply and fixing in replacement of bell ding dong AC 230 volts complete all as specified and as directed.
Supply and fixing in replacement pvc connection of size 600 mm length 50 mm dia all as specified and as directed
Roop Sons and Co
Mahajan Builder
M/s Vijay Construction Co.
BISHAN DASS
M/s AKG Engineers & Contractors
B.J.CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .