Supply, intastallation, testing & commissioning of 125 KVA Capacity radiator cooled DG Set with suitable capacity engine directly coupled with alternator for 415 volt, 3 phase, 50 Hz, 4 wire, generation system complete with accessories, fuel oil tank & control panel etc as required and sound proof acquastic enclosure for the DG SET, including supply, fixing of antivibration pads suitable for 125 KVA DG Set as per standards of Engine manufacture, provision of conrol cable from engine to control panel to engine. Provision of pipe fuel pipe line of suitable size fron fuel tank to engine and over flow pipe engine to fuel tank complete gate valve and fitting leader maker etc. Supply , Intallation of starting batteries of suitable AH as recommended by manufacterer Heavy duty complete as required at site complete with stand and battery charger residentials sylencer sutaible for diesel engine exhaust pipe line complete complete flange, bend, flexible pipe all as required and as directed by engineer incharge. DIESEL ENGINE (CPCB-4 NORMS COMPLANT) 4 Stroke, Radiaotr Coolled, Diesel Engine Model Having Following Arrangement :- Flywheel with Starter Ring for Generating Set Air Filter , Lube Oil Cooler Assembly with accessories. Exhaust air manifold Exhaust Bellow Fuel Fiter Lube Oil Filter
Exhaust Gas Turbocharger with after Coller Day tank for fuel with markings ECP Panel mounted on a separate frame. Radiator with Pusher Type Fan, With Fan Guard, Coolant Pump 24V Electrical Starting System with Starter Motor and Battery Charging Alternator Engine Mounting Supports Make Engine:- Cummins, Kirloskar & Volvo ALTERNATOR Rated at 125 KVA, 415 Volts, 3 Phase, 4 Wire, 0.8 P.F (lag), 50HZ, 1500 RPM, IN Accordance with IS 4722 as per following Specification Rating: Suitable for an over-load of 10% for 1 hour in every 12 hours operation. Voltage Regulation: Provided with fast response thyristor type electronic automatic voltage regulator, which holds output voltage within desired limits . (+/- 1%). Excitation: Self excited-self regulated. Alternator Loading: Suitable for taking rated load immediately after machine reaches rated voltage and speed. Vibration: Suitable for direct coupling with Engine and mounted on common M.S. Channel base frame.
Enclosure: Screen protected drip proof enclosure with IP – 23 degree of protection. Cooling: Air Cooled type with radial fan mounted on Rotor. Winding and Insulation: Insulation class H as defined in IS – 4722. Make Alternator:- Kriloskar, Marshall, & Leroy Somer. ACCESSORIES :- MS Base Frame Suitable for Mounting of the Offered Engine and Alternator. Day Fuel Tank of Standard Capacity Complete Fuel Gauge, Inlet/Outlet Connections, Drains Plug, Etc 2 Nos 12 Volts DC Battery of SUITABLE Capacity with Leads 1 Set of AVM Pads Fitted in Base Frame. AMF Panel with standard acessoriesetc as required at site
Construction of PCC Platform for laying of DG set (Complete Job.)
Supplying, installation, testing and commissioning of 1.5 Ton Inverter type Split AC's (copper) Cold type of minimum capacity following Specification as detailed below. 1. Should be of inverter type 2. Cooling capacity (in Tr): 1.5 3. BEE Star rating: 3 4. Maximum local temperature: 52 C 5. Rated cooling capacity (BTU/hr.): 19000 or above 6. Condensing coil: 100% Copper with grooved copper tubes 7. Electrical input, 220 V ± 30/50Hz/Single Phase 8. Noise level (indoor unit): = close to 35 dB 9. Compressor type: rotary or any other suitable technology 10. Refrigerant type: R-32 11. Anti-Corrosive Coating for the outdoor unit: Bule Fin/Gold Fin or equivalent 12. Compressor Warranty: 10 years 13. PCB Warranty: 5 year 14. Total System Warranty: 1 year 15. Minimum noise level of the indoor unit should be around 28 dB (A)
16. Should have air filtering mechanism for removing dust 17. Supplier has to include brochure of the quoted model Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. The job includes Repairs made to wall whereever as required.
Supplying, installation, testing and commissioning of 2.0/2.2 Ton Inverter type Split AC's (copper) Hot/ Cold (all weather) type of minimum capacity following Specification as detailed below. 1. Type:- Split (Indoor Unit & Outdoor Unit) 2. Cooling Capacity:- Not less than 6000 watts 3. Compressor type :- Twin Rotary type Compressor 4. Refrigerant:- Eco-friendly (Green Gas) (R-22/ R-32/ R-290/R-410A/R-600A) 5. Remote Control:- Yes 6. Swing:- Adjustable 7. Air flow adjustment:- Auto 8. Energy Efficiency i) ISEE Rating (Desired):- 05 Star Rating, Inverter type ii) BEE rated Energy Efficiency Ratio (EER):- Not less than 3.8 9. General features:- i) Filters:- Anti Bacteria/Dust filter etc. ii) Air Direction Control:- Air iii) Auto Restart:- Yes iv) Sleep Mode:- Yes
v) Timer:- Yes vi) Sound Level inside (in db):- Not more than 50 db & Sound lel outside (in db):- Not more than 56 db vii) inverter type split AC:- Yes viii) Power Supply/Consumption a) Power Supply (Volt/Phase/Hz.):- 230/Single/50 b) Power consumption (watts) with 100% loading:-Not more than 2000 watt c) Power consumption (watts) with 50% loading:- Not more than 900 watt d) Running Current (Amps):- Max 8.0 to - 9.0 Amps e) Operating Temperature (room) minimum:- 2 º C to 46 º C f) Maximum Outside (Ambient) Temperature:- Should be capable of operating at least upto 50 ºC Ambient Temperature 10. Compressor Warranty: 10 years 11. PCB Warranty: 5 year 12. Total System Warranty: 1 year Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. The job includes Repairs made to wall whereever as required.
Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary. Warrantee.:- 2 Years from the date of installation.
Supplying & fixing of M.S Wall/Floor Stand duly powder coated for outdoor unit of Split AC
Supplying & fixing of drain pipe for indoor unit 1"
Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 1.5 Ton AC
Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 2.0 Ton AC
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25/20 A modular socket outlet and 25/32 A modular SP MCB, "C" curve including connections, painting etc. as required.
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.
2 x 4 sq. mm + 1 x 4 sq. mm earth wire
Supplying and fixing of following rating 240/415 volts "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole and neutral 40 Amp
Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water . The earthing pit should be covered with PVC cover.
Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover.
Providing and fixing of 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supplying, installation, testing & Commissioning of 250 KVA Distribution Substation 11/0.433-0.250KV; 50 Hz Aluminium wound Distribution Transformer of latest energy efficiency level-2 (New), IS 1180 part-I; 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 Mtrs. suitable cable of ratings. (Aluminium upto 200 KVA, copper ratings. (Aluminium wound upto 200 KVA, copper wound for 250 KVA or higher KVA ratings) Gapless surge Arrestor, 9 KV, 10 KA, LA with polymer housing, stn. Type 11 kV Go, AB Switch 3- phase, 3-pole, 200 Amp, vertical type 11 KV Horn Gap fuse set 3 phase 200 A 70 mm²/50 mm² (2Ckt)/185 mm² (2Ckt) cable 1.1Kv Grade, PVC insulated sstranded conductor frls type 9 Mtr. Long pole, ST-410 SP33 Tapping point 11kV polymeric composite Disc insulator 12kV, min failing load 45kN, Lighting Impulse 75kV positive and 80kV Negative, creepage distance 320mm GI Channel/Angle/Flat or size including clamps Galvanized Nuts and Bolts
Earthing of substation- Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as per IS 1239. GI strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement material and earth chamber made of brick mansonary with RCC Slab cover. 11kV polymeric composite pin Insulator 12kV, 5 kN, lighting impulse 75 kV positive and 80 kV Negative, creepage distance 320 mm Galvanised stay set with 50 x 8mm stay clamp, guy insulator (2Nos.) anchor plate (200 x 200 x 6 mm) nut-bolts, 2 nos turn-buckless, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded with wire complete Wedge connectors/PG Clamps Danger Plages with clamps GI barbed wire for anti climbing
CT/PT metering unit
Cement bottoming 1:2:4 mix as per REC standards 5cum/pole
Paint of poles Red oxide
Painting of pols Aluminum paint
Sundry items like aluminium lugs, jumper binding tape
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.07 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.57 MB
BOQ_967666.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .