Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 LAccepted-AOC | ₹4.2 L | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹5.0 L+₹87,371 (21.0%)Rejected-AOC | ₹5.0 L+₹87,371 (21.0%) | L2 | Rejected-AOC L2 bidder |
| Sl No | Description | Qty | Unit | SMK ENTERPRISES L2 | Selvam Electricals and Plumbing L1 |
|---|---|---|---|---|---|
| 1.00Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The non-return valve located at the top of the pump in the discharge outlet connection is to be designed with minimum friction. The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP, Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP starting and for continuous operation. | |||||
| 1.01 | 150 Duty lpm x 125 m Head | 1 | No | 2,00,000 ₹2,00,000 | 1,17,000 ₹1,17,000 Lowest |
| 1.02 | 200 Duty lpm x 125 m Head | 1 | No | 1,35,000 ₹1,35,000 | 1,32,000 ₹1,32,000 Lowest |
| 2.00Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately). | |||||
| 2.01 | 10 HP WD-M1916 | 1 | No | 26,000 ₹26,000 | 25,600 ₹25,600 Lowest |
| 2.02 | 15 HP WD-M1918 | 1 | No | 26,000 ₹26,000 Lowest | 26,700 ₹26,700 |
| 3.00 | Supply and fixing of 400 A Three phase 500V 4 Pole Change over Switch iron suitable angle iron frame work with MS cable entry boxes with Earth connection only. SD 664 | 1 | No | 34,000 ₹34,000 | 33,800 ₹33,800 Lowest |
| 4.00 | Supply and Laying of 4 x 16 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. SD 667 | 60 | Rm | 400 ₹24,000 | 395 ₹23,700 Lowest |
| 5.00Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. | |||||
| 5.01 | WD-W0873 Above 10.00 HP to 20.00 HP | 2 | Nos | 17,500 ₹35,000 | 17,440 ₹34,880 Lowest |
Tender Value
₹5 L
EMD Value
₹5,000
Closing Date
20 Jul 2026, 3:00 pmClosed
The Commissioner , Tambaram City Municipal Corpora
1, Muthuranga Mudali St, West Tambaram, Tambaram, Chennai, Tamil Nadu 600045
Supply and Delivery and fiixing of 10Hp, 15 HP Submersible Motor including Specials in Uyalliamman Kovil Sump in Ward No.31 TCMC Zone No.01
2026_DMA_683502_1
2515/2026/E1
Open Tender
Civil Works
Item Rate
Thiruneermalai Zone 1 Pammal
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹5,000
18 Sept 2026
2 Jul 2026
20 Jul 2026
2 Jul 2026
20 Jul 2026
2 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The non-return valve located at the top of the pump in the discharge outlet connection is to be designed with minimum friction. The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP, Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP starting and for continuous operation. | |||||
| 1.01 | 150 Duty lpm x 125 m Head | - | No | - | - |
| 1.02 | 200 Duty lpm x 125 m Head | - | No | - | - |
| 2Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately). | |||||
| 2.01 | 10 HP WD-M1916 | - | No | - | - |
| 2.02 | 15 HP WD-M1918 | - | No | - | - |
| 3Supply and fixing of 400 A Three phase 500V 4 Pole Change over Switch iron suitable angle iron frame work with MS cable entry boxes with Earth connection only. SD 664 | |||||
| 4Supply and Laying of 4 x 16 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. SD 667 | |||||
| 5Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. | |||||
| 5.01 | WD-W0873 Above 10.00 HP to 20.00 HP | - | Nos | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_821620.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
BOQ_821620.xls
BOQ • 0.40 MB
DATEEXTENSION.pdf
PDF • 0.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .