Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC | ₹2.0 Cr Quoted ₹2.1 Cr | L1 | Accepted-AOC winner |
| 2 | L2₹2.1 Cr+₹3.8 L (1.78%)Rejected-AOC VILLAGE KHERLI JEETA HATHIN PALWAL 121103 | HATHIN | PALWAL | HARYANA | 121103 | ₹2.1 Cr+₹3.8 L (1.78%) | L2 | Rejected-AOC 2nd |
Tender Value
₹1.6 Cr
EMD Value
₹3.3 L
Closing Date
16 Jun 2022, 5:00 pmClosed
Executive Engineer
C.C.Palwal
instalaltion of 19 no boreholes
2022_HRY_225401_1
3135-66/25A
Open Tender
Civil Works
Item-rate/Agreement basic
150 days
Palwal
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
Yes
₹3.3 L
Yes
Palwal
27 Dec 2022
11 Jun 2022
17 Jun 2022
11 Jun 2022
16 Jun 2022
11 Jun 2022
13 Jun 2022
Amount
Mobilisation & Demobilisation of Equipment & Concerned Personnel at Site and Within site for atleast 02 Locations of setup as advised by Engineer-in-Charge.
Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part I) , including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools plants & machineries required for the job, all complete as per direction of Engineer-in-Charge, upto 90 metre depth below ground level : 200 mm dia wells for pump out.
Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-Charge, upto 90 metre depth below ground level : 100 mm dia for observatory wells.
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS : 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & ccessories all complete, for all depths, as per direction of Engineer-in-charge 200 mm nominal size dia having minimum wall thickness 5.40 mm.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS : 12818, including required hire and labour charges, fittings & accessories etc, all complete, for all depths, as per direction of Engineer-in-charge : 150 mm nominal size dia.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS : 12818, including required hire and labour charges, fittings & accessories etc, all complete, for all depths,as direction of Engineer-in-charge, 100 mm nominal size dia for observatory wells
Gravel packing in tube well in accordance with IS: 4097, including providing gravel fine/medium/ coarse, in required grading & sizes as per direction of Engineer-in-charge
Developement of tube well in accordance with IS:2800 (part 1) and IS : 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor,running the compressor for required time till well is fullydeveloped, measuring yield of well by "V"notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approval laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc, all as per requirement and direction of Engineer-in-charge.
Providing and fixing M.S. Clamp of required dia to the top of casing/housing pipe of tubewell as per IS : 2800 (part I), including necessary bolts & nuts of required size complete : 150 mm clamp.
Providing and fixing M.S. Clamp of required dia to the top of casing/housing pipe of tubewell as per IS : 2800 (part I), including necessary bolts & nuts of required size complete : 200 mm clamp.
Providing and fixing Bail plug/Bottom plug of required diato the bottom of pipe assembly of tubewell as per IS : 2800 (part I) 150mm dia.
Providing and fixing Bail plug/Bottom plug of required diato the bottom of pipe assembly of tubewell as per IS : 2800 (part I) 200mm dia.
Providing, Installation & Testing of Submersible Pump with all required fittings (Bend & Nipple, Nut - Bolt, Rubber Packing, Supporting Clamp etc.) of 10HP capacity, 4 stage, total head -39mtr, Discharge of 70000LPH at 16mtr head, all complete as desired by Engineer-in-charge.
Providing & fixing Submersible cable-1 x 3 x 4mm with submersible pump.
Control Panel with ammeter voltmeter M.C.B single phase preventer, indicator starter BCH make, 30HP, Star Delta.
Providing and Fixing G.I pipes complete with G.I. Fittings including trenching and refilling etc : 80mm
Making connection of G.I. Distribution branch with G.I. Main of following sizes by providing and fixing tee, including cutting and threading the pipe etc, complete : 50 to 80 mm nominal bore.
Providing and fixing gun metal gate valve with C.I. Wheel of approved quality (screwed end) :80 mm dia Nominal bore.
Providing and Fixing G.I Union in G.I. Pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 80 mm dia nominal bore.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting ,fixing in position and applying a primer all complete.
C.C 1:4:8 for holding of claimps and panal bord (H.S.R item No. 10.39)
RANVIR SINGH
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .