Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.3 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L1 | Accepted-AOC Accepted due to lowest rate quoted | |
| 2 | L2₹33.5 L+₹2.4 L (7.72%)Rejected-Finance | L2 | Rejected-Finance Rejected due to highest rate quoted | |
| 3 | L3₹42.8 L+₹11.7 L (37.5%)Rejected-Finance RZ 50D GALI NO 13 VASHISHT PARK PANKHA ROAD NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Rejected due to highest rate quoted |
| Sl No | Description | Qty | Unit | A B K Enterprises L2 | M/S Anand Enterprises L1 | M/S PARKASH ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.00 | M&L checking the serviceability of different spares / components / parts of security light fittings (HPSV, HPMV, Metal Halide, T-5, LED Lights, Post top, Trafic light fittings etc, any wattage/capacity) of any description and in any position, replacement of un-serviceable/damaged/ broken part(s) other than those mentioned in item No 2 , 17,18 & 19 below either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed. | 250 | Each Job | 100 ₹25,000 | 10 ₹2,500 Lowest | 100 ₹25,000 |
| 1.01Note for item No. 1.00 :- (i) New parts shall be measured and paid separately under relevant item of schedule as 'Supply only'. (ii) Necessary T&P i.e. ladder, tools etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc i.e. in any position at site. (iii) Required screws, insulating tapes, internal wiring wire , gaskets and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above item including rectification of cable fault & over head fault by fault finding/identification. (iv) Contractor shall be paid only one time the labour charges quoted above in Schedule `A' items for a particular fitting repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the fittings and replacement of unserviceable / defective parts in order to maintain the fittings in serviceable/working condition. (v) Contractor shall attend the said job as and when ordered by Engineer-in-Charge and replace the spare parts / fittings immediately witout loosing the time. (vi) Immediately, on acceptance of contract, material shall be brought by the contractor on priority basis after getting approved and attend the complaint on priority basis. (vii) Site of work is scattered in Domestic and Technical area and the contractor shall consider this aspect while quoting the rates. (viii) Contractor's supervisor shall attend the office of AGE E/M at 0900 hrs every day (except holiday) to get the task / location / nature of compaint and in the evening, shall give feed back of compaint. | ||||||
| 2.00 | Supply only 1.5 sqmm twin core PVC insulated and sheathed copper conductor multistrand cable for electric connection from overhead line / junction box to street light complete all as specified. | 500 | RM | 10 ₹5,000 Lowest | 10 ₹5,000 Lowest | 40 ₹20,000 |
| 3.00 | S&F as in repairs street light bracket made of GI Pipe 25 mm dia light grade 1.5 Mtr in length, bent to required shape fixed with 2 Set of MS Clamps made out of flat iron 40x4mm, incl bolts, nuts and washers complete all as specified and directed. | 35 | Each | 120 ₹4,200 | 100 ₹3,500 Lowest | 250 ₹8,750 |
| 4.00 | S&F as in repairs Junction box (Bus bar chamber box) of size 350 x 250x 150 mm made out palstic suitable for 415 Volt, 4 Way TPN aluminium bus bars of capacity 100 amps with 01 No. MCB, SP, 6 Amp, 240 volts, 10 KA for controlling the street light complete fixing arrangement to the pole with nut, bolts and washers including providing the electrical connection for incoming / outgoing cable through proper lugs/thimbles complete all as directed. | 65 | Each | 800 ₹52,000 | 300 ₹19,500 Lowest | 500 ₹32,500 |
| 5.00 | S&F as in repairs Junction box (Bus bar chamber box) of size 250 x 200x 105 mm made out palstic suitable for 415 Volt, 4 Way TPN aluminium bus bars of capacity 100 amps with 01 No. MCB, SP, 6 Amp, 240 volts, 10 KA for controlling the street light complete fixing arrangement to the pole with nut, bolts and washers including providing the electrical connection for incoming / outgoing cable through proper lugs/thimbles complete all as directed. | 250 | Each | 500 ₹1,25,000 | 250 ₹62,500 Lowest | 400 ₹1,00,000 |
| 6.00 | S&F as in repairs GI pipe 40 mm dia, light grade for cable protection fixed along the pole, with suitable size MS Clamps made out of 25x3mm thick flat including nuts bolts and washers complete all as directed by Engineer in charge. | 25 | RM | 180 ₹4,500 | 100 ₹2,500 Lowest | 200 ₹5,000 |
| 7.00 | M & L for prepration of old painted steel tubular pole 9 meter height by scraping with steel wire brush and cleaning the rust of pole and cross arm and applying two coat of Aluminium paint over and including a coat of red oxide primer above 1.5 m height and painting red and white strips ( 30 cm width ) with synthetic enemel paint upto 1.5 m height from bottom point, and writing the exhisting pole number with black paint in yellow circle of dia 150 mm , complete all as specified and as directed . | 200 | Each Job | 200 ₹40,000 Lowest | 200 ₹40,000 Lowest | 200 ₹40,000 Lowest |
| 8.00 | Material and labour for painting with one coats of synthetic enamel paint on RCC pole from 1.5 mtr above the GL and balance 1.5 m from ground level will be painted by synthetic enamel paint in alternatively black and white strap of 30 cm after scraping /removing the existing paint and the preparation on the surface of RCC LT pole. Pole No will be written on pole by black paint in yellow circle of 150 mm dia complete all as specified and directed.. | 50 | Each Job | 50 ₹2,500 Lowest | 200 ₹10,000 | 100 ₹5,000 |
| 9.00 | M&L repair to street panel board indoor / outdoor type of any capacity having Incomer & out going MCBs, timer switch and power contractor by carrying out the following works:-
(i) Cleaning incomer switches, bus bar & out going switches etc thoroughly by mechanichally.
(ii) Replacement of rusted bolts & nuts, screws, thimble etc as per existing.
(iii) Replacement of Incoming / out going switches as per existing make & model.
(iv) Replacement of timer switch and cortractor as per existing make & model.
(v) Replacement of control wiring with suitable size as per existing copper wire
(vi) Making the locking arrangement functional including welding if required
(vii) making proper connections for out going / incoming cable by providing suitable thimble as required.
Note: MCBs, timer switch and contractor shall be measured and paid separatly as 'Supply only' against respective item of this Schedule.. | 4 | Each | 200 ₹800 Lowest | 500 ₹2,000 | 2,000 ₹8,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
29 Oct 2025, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
REPAIR AND MAINTENANCE OF PERIMETER SECURITY LIGHT STREET LIGHT SOLAR LIGHTS DOME LIGHT HIGH MAST LIGHT AND ALLIED WORKS AT AFSSR/ REPAIR TO GEYSER FAN AND ELETRIC METER INTERNAL ELECTRICAL INCLUDING MCB DBS AND MISC ITEMS AT NTS UNDER GE (AF) GURGAO
2025_MES_734283_1
GE/GUR-/NIT-72/2025-26
Open Tender
Civil Works
Item Rate
240 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹90,000
4 Dec 2025
8 Oct 2025
31 Oct 2025
8 Oct 2025
29 Oct 2025
22 Oct 2025
M&L checking the serviceability of different spares / components / parts of security light fittings (HPSV, HPMV, Metal Halide, T-5, LED Lights, Post top, Trafic light fittings etc, any wattage/capacity) of any description and in any position, replacement of un-serviceable/damaged/ broken part(s) other than those mentioned in item No 2 , 17,18 & 19 below either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed.
Note for item No. 1.00 :- (i) New parts shall be measured and paid separately under relevant item of schedule as 'Supply only'. (ii) Necessary T&P i.e. ladder, tools etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc i.e. in any position at site. (iii) Required screws, insulating tapes, internal wiring wire , gaskets and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above item including rectification of cable fault & over head fault by fault finding/identification. (iv) Contractor shall be paid only one time the labour charges quoted above in Schedule `A' items for a particular fitting repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the fittings and replacement of unserviceable / defective parts in order to maintain the fittings in serviceable/working condition. (v) Contractor shall attend the said job as and when ordered by Engineer-in-Charge and replace the spare parts / fittings immediately witout loosing the time. (vi) Immediately, on acceptance of contract, material shall be brought by the contractor on priority basis after getting approved and attend the complaint on priority basis. (vii) Site of work is scattered in Domestic and Technical area and the contractor shall consider this aspect while quoting the rates. (viii) Contractor's supervisor shall attend the office of AGE E/M at 0900 hrs every day (except holiday) to get the task / location / nature of compaint and in the evening, shall give feed back of compaint.
Supply only 1.5 sqmm twin core PVC insulated and sheathed copper conductor multistrand cable for electric connection from overhead line / junction box to street light complete all as specified.
S&F as in repairs street light bracket made of GI Pipe 25 mm dia light grade 1.5 Mtr in length, bent to required shape fixed with 2 Set of MS Clamps made out of flat iron 40x4mm, incl bolts, nuts and washers complete all as specified and directed.
S&F as in repairs Junction box (Bus bar chamber box) of size 350 x 250x 150 mm made out palstic suitable for 415 Volt, 4 Way TPN aluminium bus bars of capacity 100 amps with 01 No. MCB, SP, 6 Amp, 240 volts, 10 KA for controlling the street light complete fixing arrangement to the pole with nut, bolts and washers including providing the electrical connection for incoming / outgoing cable through proper lugs/thimbles complete all as directed.
S&F as in repairs Junction box (Bus bar chamber box) of size 250 x 200x 105 mm made out palstic suitable for 415 Volt, 4 Way TPN aluminium bus bars of capacity 100 amps with 01 No. MCB, SP, 6 Amp, 240 volts, 10 KA for controlling the street light complete fixing arrangement to the pole with nut, bolts and washers including providing the electrical connection for incoming / outgoing cable through proper lugs/thimbles complete all as directed.
S&F as in repairs GI pipe 40 mm dia, light grade for cable protection fixed along the pole, with suitable size MS Clamps made out of 25x3mm thick flat including nuts bolts and washers complete all as directed by Engineer in charge.
M & L for prepration of old painted steel tubular pole 9 meter height by scraping with steel wire brush and cleaning the rust of pole and cross arm and applying two coat of Aluminium paint over and including a coat of red oxide primer above 1.5 m height and painting red and white strips ( 30 cm width ) with synthetic enemel paint upto 1.5 m height from bottom point, and writing the exhisting pole number with black paint in yellow circle of dia 150 mm , complete all as specified and as directed .
Material and labour for painting with one coats of synthetic enamel paint on RCC pole from 1.5 mtr above the GL and balance 1.5 m from ground level will be painted by synthetic enamel paint in alternatively black and white strap of 30 cm after scraping /removing the existing paint and the preparation on the surface of RCC LT pole. Pole No will be written on pole by black paint in yellow circle of 150 mm dia complete all as specified and directed..
M&L repair to street panel board indoor / outdoor type of any capacity having Incomer & out going MCBs, timer switch and power contractor by carrying out the following works:- (i) Cleaning incomer switches, bus bar & out going switches etc thoroughly by mechanichally. (ii) Replacement of rusted bolts & nuts, screws, thimble etc as per existing. (iii) Replacement of Incoming / out going switches as per existing make & model. (iv) Replacement of timer switch and cortractor as per existing make & model. (v) Replacement of control wiring with suitable size as per existing copper wire (vi) Making the locking arrangement functional including welding if required (vii) making proper connections for out going / incoming cable by providing suitable thimble as required. Note: MCBs, timer switch and contractor shall be measured and paid separatly as 'Supply only' against respective item of this Schedule..
Supply only following fixtures / fittings for replacement in LT Panel boards:-
MCB, 10 KA, SP, 32A
MCB, 10 KA, SP, 40A
MCB, 10 KA, TPN 63A
MCB, 10 KA, TPN 32A
Astronomical timer switch 110/240 volts Make : Havells Cat No DHTKW01016 or equivalent make of L&T, Legrand
Power contactor 60 Amp 4 pole 415 V 50 Hz model ML 4 with front mounting auxiliary contacts 2 No+ 2 NC rating Make : L&T Cat no SS90910 or equivalent
Power contactor 40 Amp 4 pole 415 V 50 Hz model ML 3 with front mounting auxiliary contacts 2 No+ 2 NC rating Make : L&T Cat no SS90721 or equivalent
S&F as in repairs LED street light 90 watt 230 volts pressure die cast aluminium housing, heat resistant toughened glass with frame, IP protection IP-66 batter optics for uniform distribution having surge protection 10 KV, sealed driver .Make : Crompton Cat Part No. TRP-411-90-57-SL-GL-NSG or equivalent make in wipro and Philips
S&F as in repairs LED street light 70 watt 230 volts pressure die cast aluminium housing, heat resistant toughened glass with frame, IP protection IP-66 batter optics for uniform distribution having surge protection 10 KV, sealed driver .Make : Crompton Cat Part No. TRP-409-70-57-SL-GL-NSG or equivalent make in wipro and Philips
Supply and fix as in repairs LED street light 60 watt 230 volts pressure die cast aluminium housing, heat resistant toughened glass with frame, IP protection IP.66 batter optics for uniform distribution having surge protection 10 KV, sealed driver in replacement of conventional street light 70/125 watt SV/MV complete all as specified and directed. Make : Crompton Cat Part No. TRP-409-60-57-SL-GL-NSG or equivalent make in wipro and Philips
Supply and fix as in repairs LED street light 45 watt 230 volts pressure die cast aluminium housing, heat resistant toughened glass with frame, IP protection IP.66 batter optics for uniform distribution having surge protection 10 KV, sealed driver in replacement of conventional street light 70/125 watt SV/MV complete all as specified and directed. Make : Crompton Cat Part No. TRP-409-60-57-SL-GL-NSG or equivalent make in wipro and Philips
S&F as in repairs LED 150 W flood light fitting with lense, high luminous efficacy,protected to IP 66, toughened glass efficient high out put emitter LED for better distribution having surge protection 10 KV, sealed driver applicable for area lighting including electrical connection . Make : Crompton Cat Part No. LFLN-150-CDL/60-M or equivalent make in wipro and Philips
Supply only LED constant current driver for 45W light fittings as per existing make complete all as specified and as directed.
Supply only LED constant current driver for 60 W light fittings as per existing make complete all as specified and as directed
Supply only LED constant current driver for 70/72 W light fittings as per existing make complete all as specified and as directed
M&L for cement concrete (1:2:4) type B1 with 20 mm graded aggregate for pole coping above ground level including form work and finishing to all exposed surfaces without using extra cement all as directed.
S&F as in repairs Aviation light 2 x 10 watt fitting complete LED type double with alternate flashing and dusk automatic control housing cast aluminium base with red diffuse lens , complete all as specified and as directed .
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exeeding 1.5 m deep, getting out the excavated earth bottom surface to required gradient complte all as specified and directed. Note:- (i) Serviceable bricks shall be stacked for reuse and Old unservicable bricks shall be sold to contractor under Sch of credit. (ii) Existing sand cushioning shall not be removed. (iii) In case different strata is met with during excavation, contractor shall not claim extra on this account.
Returning filling in, and including spreading and leveling in layers not exceeding 25 cm thick complete all as specified & directed.
M&L Removal of excavated material such as soils n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
Material and labour well burnt old size sub Class ‘B’ bricks, laid flat, in trenches for cable protection complete all as specified and as directed.
Labour only for laying well burnt old size sub Class ‘B’ bricks, laid flat, in trenches for cable protection obtained from srl no 30 above complete all as specified and as directed.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified.
Dismantling, taking out existing LT steel Poles complete with street light carefully for use from its original position and shifting to new location
Erection only of LT steel Poles 9 m long complete with streetlight of any type in truly vertical position with and including PCC for foundation and coping complete all as specified and as directed
Supply, install and errect in true vertical position steel tubular swaged welded poles single 9.0 mtr long complete with MS base plate of 6 mm thick of size 300mm x 300mm, finial taper plug, pole cap, bolts, nuts and washers and screwed, pole made out of ERW MS tubing conforming to IS-2713 ( Part II),1980 type 410-SP-31, L.T pole including pole mounted bracket for fixing of street light 1.2 m long ,drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete, painting with two coats of aluminium paint over a coat of primer complete all as specified and directed . Note : Excavation incl PCC etc in post hole in any type of strata and coping shall be included in the unit qouted rate and nothing extra shall be admissible on this account .
Supply and fix as in repairs LED bollard light 10W pressure die cast powder coated housing with PC diffuser efficient high output LED with IP 65 protection including necessary fixing arrangement with PCC foundation at site complete all as specified and as directed by Engineer-in-charge . Make : Crompton Cat Part No LBLSN-10-CDL or equivalent make in Wipro and Philips
Supply and fix LED post top lamp spherical/Oval shape with polycarbonate diffuser and IP 65 protection 40 W, LED warm white complete all as specified and as directed. Make : Crompton Cat part No-LPTO-40-CDL or equivalent make in wipro and Philips .
M&L in replacement for LED Light 400W of search light all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement with new Gate lights Crown shaped post top lantern in soothing opal finish made up of Polycarbonate, suitable LED lamp B22 base. including taking down old UNSV flood lights all as specifeid and directed. Make:- Havells model No.Upto 1 N x 20 W LED Lamp or equivalent in equivalent in Wipro/CG.
Taking down old UNSV fidder pillar and Supply, fixing, testing and commissioning in replacement of feeder pillar panel single door floor mounted and wall/pole mounted outdoor type, as per IP-55 grade, made out of MS sheet 3.15 mm thick of size 540x525x200mm with aluminium bus bar 250 Amps, 4 strip (3 phase) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, panel should be dust proof, vermin proof, powder coated , locking should be screw type, mechanical type, inter locking with 150 Amps 25 KA MCCB four pole for incomer cable, should have danger notice for 415 volts, AC, mounted on 50x50x6 mm angle iron frame having minimum 2 feet ground c
learance duly embedded in and including PCC block (1:2:4) complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands etc and providing fixing arrangements including earthing lead fixing arrangement, complete all as directed. Note :- Installation, testing, commissioning and connecting of incoming and outgoing cable connection LT feeder pillar panel shall included in rates quoted.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core
M&L for taking down unsv geyser of 25 Ltr capacity from existing position by disconnecting Elect/ water connections, from any position, locations and replacing the following unsv parts complete all as specified as mentioned below: -
(i) S&F in repairs thermostat suitable for 25 ltr storage type Vertical water heater ISI mark as per existing one complete all as specified and as directed.
(ii) S&F in repairs LED indication lamp suitable for Geysers in roud/ rectangular shape complete all as specified and as directed.
(iii) S&F in repairs Geyser assembly suitable to fix thermostat, heating elements as of the existng size suitable for 25 ltr capacity geyser including suitable washers, clamps with bolts & nuts suitable for 06/09 hole complete all as specified and as directed.
(iv) S&F in repairs fusible plug suitable for 25 ltr capacity Geysers as per existing complete all as specified and as directed.
(v) Taking down unsv bottom/ top cover plates (2 half) and S&F with new bottom/ top cover plates with machine coloumns of Geyser 25 ltr capacity complete all as specified and as directed.
(vi) S&F in repairs steel water tank suitable for 25 ltr capacity water heater vertical type as per existing model and size complete all as specified and as directed.
(vii) S&F safety plug suitable for 25 ltr capacity vertical type water heater as per existing model/ make complete all as specified and as directed.
Each Set
(viii) S&F in replacement of M S heavy duty fabricated frame suitable for holding water tank of 25 ltr capacity geyser, as per sample and existng shape and size including suitable hole for mounting the Geyser complete all as specified and as directed. Note: Sample can be taken for the geyser by the contractor from concerned JE E/M sub division before quoting the rate.
(x) S&F glass wool heat insulation superior quality suitable for geyser of Capacity 25/35/50 ltr complete all as specified and as directed.
(xi) S&F outer cover in replacement suitable for 25 ltr capacity vertical water heater as per existing model heavy duty complete all as specified and as directed.
(xii) Supply only nuts, bolts, washers suitable of existing size and model suitable for fixing of Geyser assembly with geyser tank complete all as specified and as directed.
(xiii) S&F PVC connection mesh type for HOT/ cold water supply 2' long heavy duty ISI mark as per sample complete all as specified and as directed.
Supply & fix in replacement of SPN enclosure with two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified and as directed.
S&F submain wiring with unsheathed multi-stranded FRLS Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 6 Sqmm single core HR Grade and one run of 6 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB complete all as specified and as directed.Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete.Note 1: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.
S&F submain wiring with unsheathed multi-stranded FRLS Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 4 Sqmm single core HR Grade and one run of 4 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB complete all as specified and as directed.Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete.Note 1: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.
S&F cable copper flexible 3 Core cicular type 2.5 sqmm heavy duty complete all as specified and as directed.
S&F cable copper flexible 3 Core cicular type 4 sqmm heavy duty complete all as specified and as directed.
Supply and fixing ball bearing suitable for ceiling fan,wall mounted fan, exhaust fan, pedestal fan of same size as that of existing defective one complete all as specified and as directed.
Supply and fixing bush bearing suitable for ceiling fan,wall mounted fan, exhaust fan and pedestal fans complete all as specified and as directed.
M&L for repairing of fan stator sheet as required complete all as specified and as directed.
S&F screws as per sample for fixing of fan blades with fan stator complete all as specified and as directed.
M&L for Cleaning and preparing the surfaces of ceiling fan removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan complete all as specified and as directed.
M&L for Rewinding the stator complete with super enamelled bare copper conductor with the same size and number of turns as that of the old one insulating, varnishing and pre heating complete all as specified and as directed for the following :-
Ceiling fan 1200mm/1400mm sweep.
Exhaust fan 200mm / 300 mm sweep.
Exhaust fan above 450mm sweep.
Supply and fix Cotter Pin/Split Pin Ceiling fan Bush complete all as specified and as directed.
Supply and fix Down Rod of any size as per requermant at side complete all as specified and as directed.
Supply and fix Ceiling fan cycle assembly complete all as specified and as directed.
M&L for Removing the damaged and corroded exhaust fan louvers and replacement with new louvers of following sizes:-
Exhaust fan 200mm upto 300mm sweep.
Exhaust fan above 300mm upto 450mm sweep.
M&L for Removing the damaged , corroded exhaust fan blades and replaced with new blades of size:-
Exhaust fan 150/200mm / 250mm sweep as per sample .
Exhaust fan above 300mm / 450mm sweep.
Material and labour for shifting & fixing of old serviceable exhaust fan and making circular opening by cutting stone wall in any size and shape complete with i PCC (1:2:4) B0 12.5mm graded aggregate and grouting 04 Nos bolts of size not less than 10mm dia and 100mm long with nut & washer and making good to distrubed surface complete all as specified and as directed. (Note:- Neccessary support in high rise building (ground floor to third floor) for working from out side shall be deemed inclusive).
Material and labour for Shifting & fixing ceiling fan with down rod including necessary holes, nuts and bolts, pin complete all as specified and as directed.
Material and labour for fixing fan down rod 15mm dia 2 ft long including necessary holes, nuts and bolts, pin in replacment of old u/s down rod as per site requirement complete all as specified and as directed.
Material and labour for fixing fan canopy in replacment of old broken u/s canopy as per site requirement complete all as specified and as directed.
ceiling fan blades suitable for 1200 mm sweep ceiling fan as per sample in replacment of old broken u/s ceiling fan blade as per site requirement complete all as specified and as directed.
Taking down ceiling fan (C/F of any size/make), cleaning its dust properly oiling and hanging the same back to its original position including connecting the wire to ceiling rose etc complete after completing the wiring complete all as specified and as directed.Note :- (i) The spares like cotter pin, nuts & bolts, rubber bush & hooks etc defective/damage deemed to be replaced and make the ceiling fans functional. The rates quoted for the same deemed to be included for the above job.
Taking down exhaust fan and re-connecting up including provision of cable from ceiling rose to exhaust fan after cleaning all dust complete all as specified and as directed. Note :- (i) The spares like nuts & bolts etc defective/damage deemed to be replaced and make the fans functional. The rates quoted for the same deemed to be included for the above job.
Supply & fix capacitor of 2.5 mfd complete all as specified and as directed.
Supply & fix capacitor of 3.15mfd complete all as specified and as directed.
Supply & fix capacitor of 4.0 mfd complete all as specified and as directed.
Supply & fix capacitor of 0.85/1.00 mfd complete all as specified and as directed.
Suply and fixing and connecting flexible copper twisted twin core of size 23/.00076 complete all as specified and as directed.
S & F heavy duty PVC cable 1100 volts grade , insulated aluminium multi stranded conductor, twin core wire of size 4 sqmm complete all as specified and as directed.
S & F heavy duty PVC cable , 1100 volts grade insulated aluminium multi stranded conductor, twin core wire of size 6 sqmm complete all as specified and as directed.
Supply and fixing rubber shackle complete with bolt, nut, split pin complete all as specified and as directed.
Material and labour for fixing plastic body exhaust fan blades for 250 mm sweep in replacment of old u/s platic body exhaust fan blade as per site requirement complete all as specified and as directed.
Material and labour for fixing fan motor with venitilated plastic cap suitable for plastic body exhaust fan for 250 mm sweep in replacment of old u/s motor of exhaust fan all per site requirement complete all as specified and as directed.
Supply and fix surface mounting frame less panel, square in shape, ABS housing and PC diffuser, inbuilt driver, 12 Watts complete all as specified and as directed. Item code : LD00118018 of Make : Polycab or equivalent model out of makes specified in list of makes.
S&F in replacement plastic frame suitable for 250 mm sweep ventilation fan as per existing make/ model complete all as specified and as directed.
S&F in replacement plastic frame suitable for 200 mm sweep ventilation fan as per existing make/ model complete all as specified and as directed.
S&F ventilation fan motor suitable for 300 mm sweep metal fans having double ball bearing, heavy duty motor suitable for existing make/model complete all as specified and as directed.
S&F ceiling fan 1250mm sweep, aerodyanamic profile blades for silent operation with high twist angles leading to high air delivery, rust free re-inforced ABS blades, dust and mark resistant caoting pearl white complete all as specified and as directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
TenderDocuments72.pdf
Tender Documents • 0.43 MB
BOQ_822197.xls
BOQ • 2.87 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .