Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC KOIL KOIL PULWAMA PULWAMA JAMMU KASHMIR 192301 | PULWAMA | JAMMU AND KASHMIR | 192301 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹5.0 L+₹1,830.10 (0.37%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹5.0 L
EMD Value
₹10,080
Closing Date
4 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR, 8 FBSU, AF AWANTIPUR
PROVISION OF WORK SERVICES FOR SNS JAMMER AT CCR BUILDING AT 8 FBSU
2022_MES_526347_2
GE (AF) AWA-16/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) AWANTIPUR
₹10,080
Yes
1 Sept 2022
14 Jul 2022
6 Aug 2022
14 Jul 2022
4 Aug 2022
22 Jul 2022
Amount
Demolition of cement concrete (un reinforced) in ground floors and pavings not exc 15cm thickness (below or above ground level) and removing rubbish debris outisde MOD land, complete all as specified and directed.
Taking down chowkhats or frames not exceeding 1.50 sq.m with shutters (without taking off shutters from the frames) and making good disturbed portion), complete all as specified and directed.
Taking down chowkhats or frames exceeding 1.50 sq.m and not exceeding 4.0 Sq.m with shutters (without taking off shutters from the frames) and making good disturbed portion), complete all as specified and directed.
Plain cement concrete, (1:2:4), type B-0 using 12.5mm graded crushed stone aggregate, 25mm thick, surface finished fair to receive top layer of flooring, complete all as specified and directed.
Vitrified ceramic (Light shade) coloured/printed tiles Ist quality 9 to 10mm thick (square/ rectangular), area of each tile not exceeding 0.36sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, including 15mm thick screed bed or bedding layer in cement mortar (1:6), complete all as specified and directed.
Vitrified ceramic (Light shade) coloured/printed tiles Ist quality 9 to 10mm thick (square/ rectangular), area of each tile not exceeding 0.36sqm as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, including 10mm thick rendering on brick/concrete surface in cement mortar (1:4), complete all as specified and directed.
Anodised aluminium frame for doors, windows and ventilator with one or more rebates including joining cleat for fixing etc, complete all as specified and directed.
S&F anodised aluminium door shutters , aluminium section weighing 1.00 Kg/m including supply and fixing in half upper portion of 5 mm thick glass and half aluminium composite panel board 12 mm thick for aluminium doors ,necessary joining cleats , glazing clips , rubber neoprene packing, aluminium handles 02 No's 150 mm long in each door , anodised aluminium snap beading srews etc, complete all as specified and directed.
S&F anodised aluminium window and ventilator shutters, fixed type without sash bars, aluminium section weighing 0.50 Kg/m including supply and fixing of 4 mm thick tinted glass fixed with aluminium beading, silicon lining and gaskets, necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading screws etc., complete all as specified and directed.
Four-lever mortice lock, vertical type,100mm for aluminium door, complete all as specified and directed.
Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed, complete all specified and directed.
Plain cement concrete type B1, (1:2:4), using 20 mm graded crushed stone aggregate as in benching, copping, plateform for antena and other similar nature of work etc. the like including form work and finishing all exposed surface of concrete complete all as specified and directed.
Mild steel base plate, bolts, purpose made, with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers & one hexagonal or square nut, n exc 30cm long and n.exc 12mm dia, complete all as specified and directed.
M & L for Mild steel work in stairs (framed) including stringers,treades, landing,blusters,hand rails etc including cleats , brackets, complete all as specified and directed.
Rendering 15mm thick on brick work or concrete surface in cement mortar (1:4) finished even and smooth without using extra cement, complete all as specified and directed.
Preparation of new plastered or un-plastered surfaces of walls and applying two coats of Acrylic exterior emulsion paint in camouflaging (Disruptive) pattern (Green, Grey and Brown colour) over a coat of acrylic primer, complete all as specified and directed.
Preparation of newly plastered/unplastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer, complete all as specified and directed.
Preparation of new or previously untreated steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chromate primer,complete all as specified and directed.
Preparing old decorated plastered or un-plastered surfaces of walls by scraping the surfaces, brooming down or steel wire brushing down smoke soot, mould, mass and efflorescence salts and trading oil and greasy spots etc and applying two coat of exterior acrylic emulsion paint in camouflaging (disruptive) pattern in three colours (green, grey and brown) on wall surfaces including preparation of surfaces by filling cracks/holes with white cement base putty, complete all as specified and directed.
Point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm in and including PVC casing caping, ISI marked with all connected accessories including one single core multistanded PVC insulated FRLS type, 1.5sqmm copper conductor cable unsheathed as earth continuity cable including concealed pressed steel GI terminal boxes 1.5mm thick with 3mm thick laminated sheet cover for mounting of switches, socket, fan regulators, complete all as specified and directed for the following:-
(a) One light /fan/bell point controlled by one No, one way 5/6 Amps switch.
(b) One 3/5 pin socket outlet, 5/6 Amp controlled by one No, one way switch on same board.
(c) One 3/5 pin socket outlet, 5/6 Amp, independent, controlled by one No. one way switch on independent board.
Description all as per serial item No. 20 here-in-before, but using cable of size 2.50sqmm (for phase & neutral) and 2.5sqmm as continuous earth cable for 15/16 Amps socket outlet independent point on independent board, complete all as specified and directed.
Piano type switch one way, SP, flush type, 5/6 Amps, 230 volts AC, 50 Hz in replacement, complete all as specified and directed.
Piano type bell push switch, one way, SP, flush type, 5/6 Amps, 230 volts AC, 50 Hz in replacement, complete all as specified and directed.
Piano type socket outlet, flush type, 5 pin, 5/6 Amps, 230 volts AC, 50 Hz , multipurpose type, in replacement, complete all as specified and directed
Piano type switch socket combination, flush type, 6 pin, 5/15 Amps, 230 volts AC, 50 Hz, multipurpose type in replacement, complete all as specified and directed.
Electronic type ceiling fan regulator, 230 volts, single phase, flush type in replacement, complete all as specified and directed.
Ceiling rose 3 terminals, PVC/polycarbonate/bakelite, isolated body, 230 volts AC, 50 Hz in replacement, complete all as specified and directed.
Submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 6sqmm complete drawn in and including casing caping ISI marked of suitable size and its accessories along with 1x 6sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and directed. Note :- 2 +1 run of 6Sqmm cable including casing caping of suitable size shall be measured as one running metre.
Sheet metal enclosure IP-43, IK-09 protection DB with new Sheet metal enclosure DB SPN 8 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB DP/SPN as incomer and MCB SP as outgoing, complete all as specified and directed.
Sheet steel plug & socket DB's with new Sheet steel plug & socket DB's SP with metal clad 2 pin & earth plug and socket SPN, 20 Amps, 230 volts AC, concealed type, complete with & including one MCB SPN, 20 Amps, 10 kA, including grouting in wall and making good to disturbed surfaces to match existing, complete all as specified and directed.
MCB SP, 5-32 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type, fixed in repair, complete all as specified and directed.
MCB SPN, 40-63 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type,fixed in repair, complete all as specified and directed.
Supply, fixing and commissioning LED tube light fitting in replacement,20 watts, 220 volts ,1200 mm with aluminium housing and integrated electronic driver with polycarbonate diffuser and threshold more than 10 % including connecting up with three core twisted flexible copper cable from ceiling rose , ccomplete all as specified and directed. MAKE: HAVELLS/ CROMPTON/ PHILIPS/ WIPRO.
Supply,fixing and commissioning LED bulk head light fitting in replacement with new LED bulk head light fittings 07 watt, 230 volts AC made up of pressure die cast housing, IP65 protection, 5700K including making of electrical connection with & including two core flexible copper conductor cable of suitable size with all accessories, complete all as specified and directed. MAKE: HAVELLS/ CROMPTON/ PHILIPS/ WIPRO.
S&F of LED tube light fitting, box type 230 volts AC suitable for & including 9/10 watts LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. MAKE: HAVELLS/ CROMPTON/ PHILIPS/ WIPRO.
Earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI wire 4mm dia bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20mm bore from bottom of earth pit to top of electrode and 20mm GI pipe light grade for earth wire protection complete with earth pit inplain cement concrete (1:2:4), type B0 using 12.5mm graded crushed stone aggregate with 40 mm thick cover of reinforced cement concrete (1:2:4) , type B-I , using 20 mm graded crushed stone aggregate, reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing including testing on completion, complete all as specified and and shown in electrical plate No 3 of MES Schedule 2009 Part-I, and as directed . Note:- Earthing to be done for replacement of existing earthing. The materials retrieved from earthing shall be credited to contractor. AFTER COMPLETION OF EARTHING, IF DESIRED RESISTANCE IS NOT OBTAINED, THE EARTHING WILL BE RE DONE BY CONTRACTOR AT HIS OWN RISK AND COST TO ENTIRE SATISFACTION OF ENGINEER-IN-CHARGE.
Aluminium strip 25x3.15 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing/jointing and nut bolts jointing at all joints, complete all as specified and directed.
Test point terminal block for chemical earthing made of gun metal or phosphorus bronze of size 75x75x25mm drilled and srewed including 3 Nos 8mm dia, 25mm long hex head srew, complete all as specified and as directed.
M&L for laying of insulator ceramic for mounting of earth strip any size on wall, complete all as specified and as directed.
Plate earthing complete with copper plate electrode 60 cm x 60 cm x 3 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including copper earthing strip 20x3 mm bracing/bolted with GI nuts, bolts & check nuts and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm bore GI pipe light grade for earth strip protection completeincluding provision of concrete pit in PCC 1:2:4 type B-I , using 20 mm graded crushed stone aggregate with 40 mm thick cover of RCC (1:2:4, type B-I , using 20 mm graded crushed stone aggregate) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing , complete all as specified and directed.
Copper strip 32 x 6 mm earthing lead laid in trenches/GI pipe for making grid/loop of earthing pit complete all as required at site , complete all as specified and directed.
Supply, testing, laying/fixing of XLPE Insulated cable with wall using fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc alongwith walls/poles etc. ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 4 core, complete all as specified and as directed .
M&L for fixing of surge protection device type 1+2 AC with voltage protection level 1.5kV, high discharge current Imax 50 kA (L to N ) 70 kA (N to E) , complete all as specified and as directed. Make : CrabTree/Havells/Legrand
Supply and fixing air cooled (AC) inverter type split unit air conditioner electric driven, single phase, 230 volts, AC of capacity of 2 TR, BEE 4 star rated cooling and heating function complete with cordless remote control unit and with mounting arrangments, complete all as specified and as directed. Make : Bluestar/LG/Samsung/Hitachi/Godrej
Supply and fixing Voltage stablizer for automatic operation, naturally air cooled indoor type energy efficent and designed for single phase operation of capacity 5 KVA for input variation between 170 to 280 volts with output voltage stablized at 230 vollts with accuracy + 5%, complete all as specified and as directed. Make : V Guard/Vinitec/Sinetrac/Microtek/Powerware
M/S ABBAS M. ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .