Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.9 LAccepted-AOC 11 97 SADALATLIGUDA CHOWDARIGUDA HYDERABAD TELANGANA 500088 | MEDCHAL MALKAJGIRI | TELANGANA | 500088 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L3₹45.1 L+₹5.8 L (14.9%)Accepted-AOC | L3 | Accepted-AOC NOT BEING LOWEST | |
| 3 | L4₹48.2 L+₹9.0 L (22.8%)Accepted-AOC | L4 | Accepted-AOC NOT BEING LOWEST | |
| 4 | L2₹39.2 L+₹130 (<0.01%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | Deccan Enterprises L1 | sagar construction L4 | M/S P D TUPE L2 | Bharekar Construction L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | B/R PORTION
Taking down cement plaster on kerb stone, brick or stone walls, etc including rakingin out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. | 150 | SQM | 70 ₹10,500 | 42 ₹6,300 | 30 ₹4,500 Lowest | 35 ₹5,250 |
| 2.00 | M&L for rendering 20 mm thick of fair faces of stone work in CM 1:4 with water proofing compound in double coat (15+5mm). Finished sand faces complete all as specified and directed. | 50 | SQM | 350 ₹17,500 Lowest | 560 ₹28,000 | 400 ₹20,000 | 410 ₹20,500 |
| 3.00 | M&L for rendering 10 mm thick on concrete surfaces or surfaces other than fair face of brick work in CM 1:6 finishing surfaces even and smooth without using extra cement complete all as specified and as directed. | 30 | SQM | 250 ₹7,500 Lowest | 490 ₹14,700 | 350 ₹10,500 | 351 ₹10,530 |
| 4.00 | M&L for 10mm thick rendering in CM 1:3 on concrete surface of wall ceiling, finished even and smooth using without extra cement complete all as specified and directed. | 20 | SQM | 250 ₹5,000 Lowest | 490 ₹9,800 | 350 ₹7,000 | 360 ₹7,200 |
| 5.00 | M&L for two coats of external waterproof emulsion paint over a coat of alkali resistant primer on new plastered surfaces of wall including necessary scaffolding required for painting work, safety measures etc complete all as specified & directed. | 300 | SQM | 110 ₹33,000 Lowest | 210 ₹63,000 | 150 ₹45,000 | 160 ₹48,000 |
| 6.00 | M&L for preparation of newly plastered surface of walls over 10 cm width or girth over a coat of approved primer and applying two coat of oil emulsion distemper (tint as approved by GE) over a coat of primer complete all as specified and directed. | 650 | SQM | 90 ₹58,500 | 92.4 ₹60,060 | 66 ₹42,900 Lowest | 70 ₹45,500 |
| 7.00 | M & L for preparation of newly plastered surface of ceiling and applying three coats of white wash complete all as specified and directed. | 20 | SQM | 40 ₹800 | 21 ₹420 | 15 ₹300 Lowest | 20 ₹400 |
| 8.00 | M&L for preparation of surfaces and applying 2 mm thick wall care putty (water proofing) on walls internally or externally complete all as specified and directed. | 100 | SQM | 60 ₹6,000 Lowest | 112 ₹11,200 | 80 ₹8,000 | 100 ₹10,000 |
| 9.00 | M&L for preparation of old distembered wall surfaces and applying two coat of oil bound distemper complete all as specified and directed. | 1,500 | SQM | 70 ₹1,05,000 | 84 ₹1,26,000 | 60 ₹90,000 Lowest | 70 ₹1,05,000 |
| 10.00 | All as per item No 09.00 here in before but one coat of oil emulsion distemper complete all as specified & directed. | 875 | SQM | 50 ₹43,750 | 49 ₹42,875 | 35 ₹30,625 Lowest | 40 ₹35,000 |
Tender Value
₹40.2 L
EMD Value
₹81,000
Closing Date
28 Jul 2025, 6:00 pmClosed
GE I R AND D GIRINAGAR PUNE
GE I R AND D GIRINAGAR PUNE
PROV OF CIVIL WKS FOR INSITE DEVELOPMENT OF CO2 LABORATORY IN ROOM NOS 7 8 OF P 219 INTERNAL EXTERNAL PAINT WK IN BLDG NO P 236 P 237 REPAIR REPAINTING WK OF PERIPHERY WALL NEAR YAMUNA HOSTEL REPAIR REPLACEMENT OF SEWAG PIPE AT DIAT GIRINAGAR PUNE
2025_MES_719192_1
GE I R AND D GNR TOKEN 03 OF 2025-2026
Open Tender
Civil Works
Item Rate
180 days
GE I R AND D GIRINAGAR PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE I R AND D GIRINAGAR PUNE
₹81,000
Yes
9 Sept 2025
8 Jul 2025
30 Jul 2025
8 Jul 2025
28 Jul 2025
14 Jul 2025
8 Jul 2025 - 11 Jul 2025
Amount
B/R PORTION Taking down cement plaster on kerb stone, brick or stone walls, etc including rakingin out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L for rendering 20 mm thick of fair faces of stone work in CM 1:4 with water proofing compound in double coat (15+5mm). Finished sand faces complete all as specified and directed.
M&L for rendering 10 mm thick on concrete surfaces or surfaces other than fair face of brick work in CM 1:6 finishing surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for 10mm thick rendering in CM 1:3 on concrete surface of wall ceiling, finished even and smooth using without extra cement complete all as specified and directed.
M&L for two coats of external waterproof emulsion paint over a coat of alkali resistant primer on new plastered surfaces of wall including necessary scaffolding required for painting work, safety measures etc complete all as specified & directed.
M&L for preparation of newly plastered surface of walls over 10 cm width or girth over a coat of approved primer and applying two coat of oil emulsion distemper (tint as approved by GE) over a coat of primer complete all as specified and directed.
M & L for preparation of newly plastered surface of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of surfaces and applying 2 mm thick wall care putty (water proofing) on walls internally or externally complete all as specified and directed.
M&L for preparation of old distembered wall surfaces and applying two coat of oil bound distemper complete all as specified and directed.
All as per item No 09.00 here in before but one coat of oil emulsion distemper complete all as specified & directed.
M&L for preparing old painted surfaces of wood and wood based surfaces of any description over 10 CM width or girth & applying one coat of synthetic mnamel paint complete all as specified and directed.
M&L for preparation of old painted surfaces of steel & Iron of any description over 10 CM width or girth and applying one coat of synthetic enamel paint (1st quality) complete all as specified and directed.
M&L for complete removal of existing treatment for surfaces of walls/roof projection / chajja including concrete (plastered or un plastered) by brooming down and scraping wherever necessary and apply two coats of external waterproof emulsion paint including necessary scaffolding required for painting work, safety measured etc complete all as specified and directed.
Material and labour for preparation of old painted steel or iron surfaces of any descreption over n exc 10 cm width or girth and applying one coat of synthetic enamel paint of approved tint or shade complete all as specified and directed.
Material and labour for writing letters or figures with synthetic enamel paint (Block, Roman, Italic or Indian) n.exc 30 cm height complete all as specified and directed.
Demolition of brick work or stone masonry / PCC block walling built in cement mortar or cement lime mortar incl arches, pillers etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed.
Dismantling fencing wire mesh, any type complete all as specified and directed.
S&F chain link fencing of mesh size 50mm x 50mm line wires of dia 3mm including standards rails, straining bolts, etc including provision of binding wire complete all as specified and directed.
S&F mild steel round bars 10mm dia and over cut to length bent to shape required including cranking, bending, spirally for hooking ends stiffeners confirming to FE-410-W (Gde E 250) quality-A or Fe 290 (Gde E-165) complete all as specified and directed.
M&L for mild steel flat iron fillets (for securing wire mesh) including all necessary drilling, bolting or riveting etc and similar work conforming to FE-290 Gde E-165 complete all as specified and directed.
M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in mass concrete complete all as specified and directed.
M&L for precast cement concrete block walling exc. 10 cm width with solid block PCC 1:3:6 type C1 (using 20 mm graded stone agg) and setting in cement mortr (1:6) complete all as specified and directed.
M&L fly ash brick work straight or curved on plan exc 6 m mean radius built in cement mortr 1:6 complete all as specified and directed.
M&L for rendering 15 mm thick on other than fair faces of brick or concrete surfaces in CM (1:4), finishing even and fair without using extra cement complete all as specified and directed.
S&F rolled mild steel in joint, channels, angles or tee sections, fixed, post independently without connecting plates, etc, conf to Fe 410-W (Gde-E-250) quality 'B' complete all as specified and directed.
M&L for preparing new steel surface and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Demolition and breaking up 150 mm bore drain pipes (SWG, AC or RCC pipes) set in CM complete all as specified and directed.
Demolition and breaking up 200 mm bore drain pipes (SWG, AC or RCC pipes) set in CM complete all as specified and directed.
Demolition and breaking up 300 mm bore drain pipes (SWG, AC or RCC pipes) set in CM complete all as specified and directed.
M&L for providing plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for provided reinforced cement concrete pipe 150mm bore class NP-2 with collars laid and jointed with cement complete all as specified and directed.
M&L for provided reinforced cement concrete pipe 200mm bore class NP-2 with collars laid and jointed with cement complete all as specified and directed.
M&L for provided reinforced cement concrete pipe 300mm bore class NP-2 with collars laid and jointed with cement complete all as specified and directed.
M&L for provided reinforced cement concrete pipe 600mm bore class NP-2 with collars laid and jointed with cement complete all as specified and directed.
M&L for providing bed to drain pipes 150mm dia in cement concrete (1:3:6) type C2 using 40mm graded stone aggregate including packing under and haunching against the sides of pipe after they are laid & tested complete all as specified and directed.
All as per item No 37.00 herein above but 200mm dia pipes complete all as specified and directed.
All as per item No 37.00 herein above but 300mm dia pipes complete all as specified and directed.
All as per item No 37.00 herein above but 600mm dia pipes complete all as specified and directed.
M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in surface channels and bed of drains complete all as specified and directed.
Cutting into existing manholes for connecting new drains internal dia of pipe 150mm making good to pipe & to or finished and reforming benching as required. 3/4 section in cement concrete (1:2:4) type B-1, smoothcutting out existing benching for forming branch channel (1/2) rendering complete all as specified and directed.
M&L for providing cast iron, soil & waste and vent pipes in any length, with or without ears with cement joints fixed to walls using pipes 75mm bore including dismantling of old existing pipe complete all as specified and directed.
M&L for providing cast iron, soil & waste and vent pipes in any length, with or without ears with cement joints fixed to walls using pipes 100mm bore including dismantling of old existing pipe complete all as specified and directed.
S&F of CI bends (any radius) diminishing pipeces or taper, 100mm bore in repairs complete all as specified and directed.
S&F of CI bends (any radius) diminishing pipeces or taper fitted with oval acces door 100mm bore in repairs complete all as specified and directed.
S&F of CI bends (any radius) diminishing pieces or taper, 75 mm bore in repairs complete all as specified and directed.
S&F fo CI bends (any radius) diminishing pieces or taper fitted with oval ccess doors 75mm dia, in repairs complete all s specified and directed.
S&F of CI branch pieces single (equal or unequal) ordinary or inverted (Spigot or socket type) or with parallel branches 100mm bore complete all as specified and directed.
S&F in repairs for 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to wall or floor etc using synthetic rubber adhesive cement solvent complete all as specified and directed.
S&F in repairs for 100mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to wall or floor etc using synthetic rubber adhesive cement solvent complete all as specified and directed.
S&F in repair for Stack clamps for bore (any dia) of pipe oput of 50 mm by 5 mm flat iron and 16mm dia round iron stays, 100mm including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S&F for 75 mm dia PVC (SWR) bends any radius complete all as specified and directed.
S&F for 75 mm dia PVC (SWR) junction single (single T) complete all as specified and directed.
S&F for 75 mm dia PVC (SWR) branch piee single (single Y) equal for unequal complete all as specified and directed.
S&F for 75 mm dia PVC (SWR) vent cowl complete all as specified and directed.
S&F for 110 mm dia PVC (SWR) bends any radius complete all as specified and directed.
S&F for 110 mm dia PVC (SWR)junction single (single T) complete all as specified and directed.
S&F for 110 mm dia PVC (SWR) vent cowl complete all as specified and directed.
Dismantling floor, hearth or wall tiling/ chequered tile/interlocking the including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premise complete all as specified and directed.
M&L 25 mm thick Cement concrete 1:2:4 type B-0 using (12.5 mm graded stone aggre) as in sub base of floor complete all as specified and directed.
S&F, glazed ceramic tiles coloured (350mm x 250mm/ 450mm x 350mm x 7mm thick) or size as approved thick in wall dado etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match rendering with and over 10mm thick in CM 1:6 on stone masonry surfaces or surfaces other than fair face of brick work/ concrete surfaces complete all as specified and directed.
S&F, Non skid ceramic tiles Coloured 7 to 8 mm (square/rectangular) area of each tile exc 0.11 sqm but nexc 0.18 sqm in floors etc set and jointed in net cement slurry & pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 (using 40 mm graded stone aggregate) type C-2 as in floors, paving, plinth protection, finished even and smooth without using extra cement complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base or simillar works complete all as specified and directed.
S&F for glossy finished chequered cement concrete tiles 30cm x 30cm x 30mm /20 cm x 20 cm x 25 mm (as approved) thick set jointed with grey cement and pigment and pointed in neat cement slurry with and including 15mm thick screed bed of CM (1:6) in floors complete all as specified and as directed.
M&L for cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) complete all as specified and directed.
M&L for plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth complete all as specified and directed.
Demolition of R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.(Demolition of invert slope of chajja)
M&L for rectified Ceremic tiles (Antiskid ) in floor in Size of Tile 400 x 400 mm(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. complete all as specified and directed.
Dismantling doors, windows and clerestory windows (steel, aluminium or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 sqm and below complete all as specified and directed.
Taking out doors, windows and clerestory window shutters (steel, aluminium or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below complete all as specified and directed.
S&F factory made pressed steel frames made out from 1.25mm thick steel sheet for doors of size 125x60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.and including treated with tar or coal tar black paint on steel surfaces in contact / embeded in concrete or masonary work including Filling hollow portion of frame with PCC 1:3:6 type C-1 complete all as specified and directed.
S&F factory made pressed steel frames made out from 1.25mm thick steel sheet for doors of size 105x60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.and including treated with tar or coal tar black paint on steel surfaces in contact / embeded in concrete or masonary work including Filling hollow portion of frame with PCC 1:3:6 type C-1 complete all as specified and directed.
M&L for factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer in-Charge.
M&L for factory made 30 mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mmx 1 mm, painted with primer , all four corners of reinforcement to be welded orsealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5mm PVC sheet as panel. The styles and rails will be mitred cut and joint with the help of PVC solvent cement & self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8 mm complete as per manufacturer's specifications and direction of Engineer-in-charge. Non decorative finish
S&F wire gauge 35 mm thick shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws shutters with ISI marked M.S. pressed butt hinges bright finished of required size Kiln seasoned and chemically treated hollock wood.
S&F 300mm aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete complete all as specified and directed.
S&F 150mm aluminium tower bolts, ISI marked, with necessary screws etc complete complete all as specified and directed.
S&F in repairs 25mm bore stainless steel 304 grade curtain rods with suitable fancy type brackets and fixed in position using stainless steel screws complete all as specified and directed.
Taking down exisiting vitreous wash basin of any size in repairs complete all as specified and directed.
M&L for wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mmwith a pair of 15 mm C.P. brass pillar taps complete all as specified and directed.
Taking down exisiting vitreous china water closet squatting pan (Indian Type) including PVC flush Tank in repairs complete all as specified and directed.
S&F 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete all as specified and directed.
S&F 15mm bore C.P. brass stop cock (concealed) of standard design complete all as specified and directed.
S&F 15mm bore C.P. brass angle valve for basin mixer, flush tank and geyser points complete all as specified and directed.
S&F in repair 15mm Bore Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
S&F uplasticised PVC connection pipe, 15 mm nominal bore, with brass unions :45 cm length complete all as specified and directed.
S&F C.P. brass long body bib cock, 15 mm nominal bore of approved quality conforming to IS standards and weighing not less than 690 gms complete all as specified and directed.
S&F PTMT grating of approved quality and colour of rectangular type with openable circular lid complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections including cleaning for refixing with all fittings complete all as specified and directed.
All as per item No 93.00 here in before but 20 mm bore GI tubing complete all as specified and directed.
S&F Chlorinated Polyvinyl Chloride (CPVC) pipes 15mm bore having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints concealed work, including cutting chases and making good the walls etc. complete all as specified and directed.
S&F Chlorinated Polyvinyl Chloride (CPVC) pipes 20mm bore having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete all as specified and directed.
M&L for 15 mm for cement plaster on rough side of single or half brick wall of mix:1:6 complete all as specified and directed.
M&L for 15 mm for cement plaster on rough side of single or half brick wall of mix:1:4 complete all as specified and directed.
Complete removal of old dry or oil bound distemper, water proofing cement paint, white wash, colour wash and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete all as specified and directed.
M&L for finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) including preparation of surface complete all as specified and directed.
M&L for three coats of white wash on new surfaces with lime to give an even shade complete all as specified and directed.
M&L for float glass panes 3.0 mm thick glass panes (weight not less than 12.50 kg/sqm) complete all as specified and directed.
S&F fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching wood beading complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar 100/75 mm internal dia complete all as specified and directed.
S&F 110mm bore on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes complete all as specified and directed.
S&F 75mm bore on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes complete all as specified and directed.
S&F bright finished brass helical door spring (superior quality) complete all as specified and directed.
S&F C.P. brass shower rose with 15 mm inlet 150 mm diameter complete all as specified and directed.
S&F PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms complete all as specified and directed.
M&L for removing old APP membrane of any thickness and description carefully without damaging the mother slab from roof and disposing off out side MD Land complete all as specified and directed.
M&L for providing, cement concrete type B0 1:2:4 (12.5 mm gde Agg) in leavel course average thickness 40mm of roof/ chajja kerbs and making the surface even and smooth, including proving dummy/ constructions as per requirement at site and filling the joints with Fosroc joint filler as per manufacturer instructions complete all as specified and directed.
M&L for surface preparation and application of Polyurethane (PU) Based Sealant/Waterproofing Membrane treatment to concrete surfaces as under- 1. Surface Preparation: Thorough mechanical cleaning of all existing surfaces to be treated, ensuring complete removal of any and all bituminous residue, dirt, dust, loose materials, oil, grease, paint, or other deleterious substances. This shall involve, but not be limited to, cutting, chipping, grinding, wire brushing, and clearing debris, as necessary to achieve a sound, clean, and dry substrate suitable for primer application. All prepared surfaces shall be inspected and approved by the Engineer-in-charge prior to the commencement of subsequent operations. 2.Primer and Polyurethane (PU) Sealant/Membrane Application: Supply and precise application of a compatible, high-quality PU based primer to the prepared surface, strictly in accordance with the manufacturer's specifications and Engineer's directives. Following the primer, supply and apply a high-performance, single or multi-component PU based sealant/waterproofing membrane system to achieve a uniform dry film thickness of 1.0 mm across the entire treated area. The application shall be executed by trained personnel, adhering to best practices and manufacturer's guidelines to ensure seamless coverage and proper bonding. 3.Technical Specifications for PU Based Chemicals: The PU based chemicals (both primer and sealant/membrane) used shall conform to the following minimum technical specifications: Elasticity: Highly Elastic,UV Resistance: High resistance to Ultraviolet (UV) radiation for long-term durability.Adhesion to Concrete: Strong and durable adhesion to concrete substrates.Tensile Strength (Free Film): Not less than 2.0 N/mm²,Elongation: Not less than 300%,Solid Content (by Weight): Not less than 60%,Air/Water Permeability (as per BSEN 12390 at 5 bar - 72 hours): Nil air permeability and effectively zero water permeability.Waterproofing Membrane Dry Film Thickness (finished): 1.0 mm (one point zero millimeters),Accelerated Weathering (as per ASTM 453): Capable of passing 1000 hours without significant degradation.Reaction to Fire: Completely non-inflammable, as per relevant standards and Engineer's approval. The quoted rate shall be comprehensive, including all necessary materials, labor, tools, plant, equipment, scaffolding, consumables, supervision, testing, and all other incidentals required to complete the work as specified and as directed.
E/M PORTION S&Fix MCB DB VTPN 4 ways,with metal double door ,IP -43 protection suitable for MCCB as incommer and MCB as out going,VTPN DB's 415 volt 3 phase complete with appropriate size copper bus bar and neutral link as required at site and including cutting chases to wall for fixing of DB and making good distrubed wall/surface all as required at site complete all as specified and as directed.
S&F MCB DB SPN 08 ways double door horizontal type, 230 Volts on surface/ recess, complete with tinned suitable capacity bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc complete all as specified and as directed.
S&F MCCB 4 Pole, 415 V,adjustable type, 100A with breaking capacity 36 KA Make Legrand complete all as specified and as directed.
S&F MCB TPN 63 A, 415V 'C' curve with 10kA breaking capacity with ISI marked as per IS/IEC 60898-1 2002 and complete all as specified and as directed.
S & Fix MCB, single pole & Neutral, 240 volts, 6 to 32 Amps, all as specified and as directed.
S & Fix MCB, single pole, 240 volts, 6 to 32 Amps, all as specified and as directed.
M&L For Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified nd indicated testing on completion including fill up the earth pit with soil for best result and removal of excavated material from the site complete all as specified and directed. Note :- Earth protection pipe & earthing lead wireupto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
Supply and fix UPS for 3 hours back up three phase AC input 300 to 450V and out put single phase AC out put Voltage 230 V ± 1% of capacity 30 KVA complete all as specified by Engr-in-charge.
Supplying Installing testing & commissioning diesel engine driven generating set 415 V, 3 Phase, 4 Wire as per BS 5514/IS-10002 complete with Automatic on mains failure (AMF) panel, of capacity continuous rating 30 KVA conforming to CPCB IV+ norms at NTP conditions with acoustic enclosure considering all derating factors and comprising of the following :- (a) ALTERNATOR : Closed type regulated with brushless self excitation 415 V, 3 Phase, 4 Wire, 50 HZ, 0.8 PF 1500 RPM with voltage variation plus or minus 2.5% of rated voltage from no-load to full-load Anti vibration mounted drip proof type with class 'F' insulation, steel ball/roller bearings at both ends of the alternator shaft, with necessary controls as recommended by the manufacturer confirming to BS-5000/IS-4772 capable of supplying unbalanced load, alternator make: as specified in tender documents.(b) Engine : Multi/cylinder compression ignited, heavy duty, turbocharged, compact diesel engine water cooled through radiator with water pump hydraulic governing mechanism, all as per BS-5514/IS-3046, 1500 RPM class A1 governing/control gauges. RPM/Hours meters etc suitable for generating application and capable of giving an output of 30 KVA for coupled altemator under NTP conditions, complete with following :- (i) Flywheel with housing ad mesh protection. (ii) Flexible coupling set dirctly mounted to engine and alternator with coupling guard. (iii) Air-cleaner dry type with vacuum indicator. (iv) Fuel pump FIP/CRDI and fuel piping 15mm MS Pipe with bends, flanges etc. (v) Fuel filter with water separator and filter element. (vi) Lub-oil filter with filter element. (vii) DC heavy duty starter 24 Volts. (viii) Maintenace free DC batteries 180 AH 24 Volts (ix) Engine overspeed stop/trip switch. (x) Radiator with fan, thermostat. (xi) Dynamo/Alternator for battery charging. (xii) Corrosion inhibitor coolant. (xiii) Engine control panel electronic digital display type consisting of battery voltage indicator lub oil temp and pressure gauges, coolant water temp gauge RPM indicator cum hour meter etc. (xiv) Safety controls for alram due to high water temp (HWT) and low luib oil pressure (LLOP). (xv) Any other devices/ accessorsdies recommended/supplied by the manufacturers as standard eqpt. Engine make: as specified in tender documents.
(c) The engine and alternator will be coupled, aligned and mounted on a specially designed common base frame fabricated from MS channels of suitable cross sectional area and length with bottom drilled holes suitable for and including supplying and fixing anti vibration pads, Make Dunlop/Polybond of reqd size and numbers as recommended by the OEM for mounting of 30 KVA DG Set.(d) Indoor Automated mains failure panel fabricated from CRCA Sheet, self supporting of appropriate size suitable for unmanned operation of DG set incl necessary contactors and Bi- passing arrangements, manually operated on-load change over 63 Amps with all type of indicators and remote controlled operation of DG set and incl necessary wiring between DG set and AMF panel inside GI pipe 40 mm dia as specified and directed.(e) Diesel tank of adequate capacity for 24 hrs continous run on full load, with caliberated scale (fuel level indicator ) dip stick, fuel inlet/outlet, Air vent drain plug and intlet arragement for direct filling, incl suitabsle size gate valve in outlet, tank to be fitted at suitable height. (f) Acoustic encloser with canopy cover to be provided as per CPCB norms. (g) PCC/RCC foundation complete as per OEM design. (h) Documents : Three sets of following documents :- Maintenance and operation manuals for engine and alternator, spare parts catelogue, warranty/test certificates, schematic diagrams of control pannels. (j) Misc items : List of tools and two years normal maintenance spares as per OEM recommended lists, duly prices item wise (k) On load Change over switch 63 Amps 415 volts, 4 pole - 01 No. Note:- (i) Contractor shall satisfactorily conduct load tests of DG Set for 12 hrs incl run on 10% overload for 1 hr. (ii) Testing eqpt and man power required shall be arranged by the contractor at his own risk & cost. (iii) Fuel/ lubricats required for 1st load test shall be arranged by by the contractor at his own risk & cost. (iv) All connections with M & L for appropriate approved size XLPE armoured heavy duty 1100 V grade aluminium conductor cable from DG set to AMF and AMF to LT FPB for power and control cables are deemed to be included in quoted rates.
Material & labour for Earthing using GI earth plate electrode of size 60cm X 60cm X 6mm thick burried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron strip of size 32X6 mm by means of bolts, nuts, check nuts and washers made of GI and protected by light grade 40 mm dia galvanised iron pipe and GI pipe medium grade 20 mm bore for watering, including funnel, wire mesh, CI pit cover and PCC chamber pit with PCC 1:2:4 type B-2 (including necessary excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown on plate No 3 of SSR Part-I 2009.
S & F roof trusses (framed) and post , trussed , purlins , rails and fastenings and heavy bracket framing (beam , tee ,angle , channel or flat section) including distance pieces MS screw nut bolts heavy duty with applying two coat of synthetic enamel paint over a coat of redoxide and fastining arrangement/welding etc using FE-410 W ( Grade E-250 quality A) complete all as specified and directed.
S & F pre-painted galvalume aluminium zinc coating GI based trapezoid profile steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall , fixed with self tapping screws complete in all respect as specified and directed.
M&L for cement concrete in foundation , filling mass concrete using type D-2 1:4:8 (using 40 mm nominal size crushed and graded stone aggregate) including excavation and removal of soil at site complete all as specifioed and directed.
M & L for surface excavation n exc 30cm deep and averaging 15 cm deep and getting out loose /soft soil completed all as specified and as directed.
M & L for Removing excavated materials to a distance n exc 50 mt and depositing where directed at a level n exc 1.5 mt above the starting point complete all as specified and as directed.
M & L Hardcore of gauge exc 63mm but nexc 100 mm ,deposited,spreaded and levelled in layer n exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M & L Plain cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate as in surface channels & drains etc complete all as specified and as directed.
M & L for cement concrete type B1 (1:2:4) using 20 mm graded stone aggregate as in cils , steps,seismic,parapet and railing up to 60 cm in height ,coping , kneelers,apex stone,bedplate, kerbs water throughs and like including weathering,slightly rounded and chamfered angle throating and necessary formwork all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of folowing sizes: - (a) 50 sq mm 3.5 core
(b) 35 sqmm 3.5 core cable.
Supply & Laying 40 mm outside dia double wall corrugated pipe (DWC) ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out soft / loose soil for laying cables / pipes / erection of poles etc.
Returning filling in soil including spreading levelling watering well ramming in layers not exceeding 25 cm each.
Supply and fixing GI tubing (ISI Marked) 40 mm bore, light grade for cable protection with all necessary fittings as required, laid in trenches, under road/floors or on electric poles complete all as specified and directed.
M&L for road cutting upto 45 cms width and depth 60 to 75 cm for laying GI pipe light grade/ hume pipe for cable protection including returning filling in and making good the disturbed portion to match with the existing roads by cement/ bitumen as directed.
S&F MCCB TP, 415 V,adjustable type, 63 A with breaking capacity 16 KA
Supply and laying tubes, Galvanised,"medium " grade, with all fittings and fixed to walls, ceiling or laying in floors, all as specified for following size:- (a) 50 mm bore pipe
(b) 40 mm bore
(c) 25 mm bore
(d) 20mm bore
Supply and fixing of Gun metal gate valves with iron wheel head, screwed both ends for iron pipes complete, size of GM gate valve : (a) 50mm bore
(b) 40 mmbore
(c) 25 mmbore
(d) 20 mm bore
Labour for Cutting the existing CI pipe line all as specified and as directed by Engr-in-Charge.
M&L for submain wiring alongwith earth wire with the following size of FRLSH PVC insulated copper conductor single core cable, multistranded concealed in the surface through and including suitable size of PVC conduit on walls/ roofs/ ceiling with its accessories all as specified and directed by Engr-in-charge for the following :- (a) 2x4.0 Sqmm and 1x4 sq mm as earth wire. Note : 2 Runs of 4.0 Sqmm cable, 1 run of 4.00 Sqmm wire & PVC conduit shall be measured and paid as one unit.
(b) 2 x 6.0 sqmm and 1x6 sqmm as earth wire Note : 2 Runs of 6.0 Sqmm cable, 1 run of 6.00 Sqmm wire & PVC conduit shall be measured and paid as one unit.
(c) 2 x 10 sqmm and 1x10 sqmm as earth wire Note : 2 Runs of 10.0 Sqmm cable, 1 run of 10.00 Sqmm wire & PVC conduit shall be measured and paid as one unit.
S&F MCCB 4 pole, 415 V, adjustable type, 63 A with breaking capacityy 25 KA complete all as specified and directed.
S&Fix of MCB single pole and neutral, 240 volts, 63 Ampere, rupturing capacity 16 KA, 'C' series complete all as specified and directed.
S&F of MCB single pole & Neutral, 240 volts, 6 to 40 Ampere, rupturing capacity 10 KA, 'C' series complete all as specified and directed.
Supply and fixing single pole and neutral enclouser with two pin and earth plug and socket complete with one single pole MCB with 240 V 20 AMPs complete all as specified and directed.
M&L for cutting holes into or through cement concrete slabs, chajjas, etc reinforced for making hole for split AC piping including making good the disturbed surfaces and packing complete all as specified and directed.
S&F copper tubing alongwith necessary insulation as per manufacture stndard for 1.5/2.0 TR split AC unit, copper tubing pipe (1/4") or (3/8") and (1/2") or (5/8") as per OEM preferred size with necessary fittings jointing for split type AC including provision of insulation on tubing complete all as specified and directed.
M&L earthging complete with galvanised steel earth plate electrode 60 x 60cm x 06mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm di by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion.
Supply, laying and testing cable XLPE LY UG cable of size 70 sqmm 3.5 core Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complee all as specified and directed.
Supplying and laying of following size DWC pipe of size of bore size 50mm ISI marked alongwith all accessories etc confirming to IS 14930, prt II complete with fitting and cutting, jointing etc in trench/ open, for LT UG cable protection complete all as specified and directed.
M/S P D TUPE (BID ID -3374512)
Bharekar Construction (BID ID -3374695)
sagar construction (BID ID -3373937)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .