RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC) Chest Press - Outdoor Gym Equipments ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) TYPE Type Chest Press Double Chest Press Single
RequiredChest Press Double SIZE Length 2000 * Width 715 * Height 2200 * CAPACITY Maximum User Weight ( Kg ) 120 100
Required110
Required120 1/6 MATERIAL Governing Specification for GI Pipes BIS specification No IS 1161:2014
Requiredlatest BIS specification No IS 1239 ( Part 1 )- 2004
Requiredlatest
RequiredBIS specification No IS 1161:2014
Requiredlatest All the GI Pipes are ISI marked Yes Yes
RequiredNo Main Central Pipe 100mm Nominal Bore G.I. Pipe 80mm Nominal Bore G.I. Pipe
Required100mm Nominal Bore G.I. Pipe
Required125 mm Nominal Bore G.I. Pipe
Required150mm Nominal Bore G.I. Pipe Main Central Pipe
RequiredClass as per IS 1239 Heavy Medium
RequiredHeavy
RequiredNot applicable for pipe as per IS 1161 Designation of Main Central Pipe ( as per IS 1161 ) 100mm NB * Handle Frame 40mm Nominal bore G.I. pipe 32mm Nominal bore G.I. pipe
Required40mm Nominal bore G.I. pipe Handle Frame Pipe
RequiredClass as per IS 1239 Heavy Medium
RequiredHeavy
RequiredNot applicable for pipe as per IS 1161 Designation of Handle Frame Pipe ( as per IS 1161 ) 40mm NB * Seat Frame 32mm Nominal Bore G.I. Pipe 32mm Nominal Bore G.I. Pipe
Required40mm Nominal Bore G.I. Pipe Seat Frame Pipe
RequiredClass as per IS 1239 Heavy Medium
RequiredHeavy
RequiredNot applicable for pipe as per IS 1161 Designation of Seat Frame Pipe ( as per IS 1161 ) 32mm NB * Connecting Links 32mm Nominal Bore G.I. Pipe 25mm Nominal Bore G.I. Pipe
Required32mm Nominal Bore G.I. Pipe
Required40mm Nominal Bore G.I. Pipe
Required10mm thick MS plates
Required12mm thick MS plates Connecting Links Pipe
RequiredClass as per IS 1239 Heavy Medium
RequiredHeavy
RequiredNot applicable for M.S. Plates and Pipes as per IS 1161 Designation of connecting link Pipe ( as per IS 1161 ) 32mm NB * 2/6 Foot Rest Pipe 32mm Nominal Bore G.I. Pipe 25mm Nominal Bore G.I. Pipe
Required32mm Nominal Bore G.I. Pipe Foot Rest Pipe
RequiredClass as per IS 1239 Heavy Medium
RequiredHeavy
RequiredNot applicable for pipe as per IS 1161 Designation of Foot Rest Pipe ( as per IS 1161 ) 32mm NB * MS Foundation Plate Thickness 12 10
Required12 Foundation Pipes with anchoring 500mm deep GI Pipe
Requiredsupported with M.S. Angle 25 X 25 X 4mm 750mm deep GI Pipe
Requiredsupported with M.S. Angle 25 X 25 X 4mm
Required500mm deep GI Pipe
Requiredsupported with M.S. Angle 25 X 25 X 4mm Nominal Bore of Foundation Pipe 100mm 80mm
Required100mm
Required125mm
Required150mm Foundation Pipe
RequiredClass as per IS 1239 Heavy Medium
RequiredHeavy
RequiredNot applicable for pipe as per IS 1161 Designation of Foundation Pipe ( as per IS 1161 ) 100mm NB * Galvanization of all Pipes Zinc coating on the tubes shall be in accordance with IS 4736 latest. * Seat and Back Rest 3mm thick
RequiredHDPE with uniform bending radius to avoid sharp edges 2mm Thick G.I. Seat with uniform bending radius to avoid sharp edges
Required3mm thick
RequiredHDPE with uniform bending radius to avoid sharp edges
Required6mm thick
RequiredFibre Reinforced plastic with uniform bending radius to avoid sharp edges
Required2.5mm thick
RequiredM.S. Perforated with uniform bending radius to avoid sharp edges
Required3mm thick
RequiredLLDPE with uniform bending radius to avoid sharp edges Hand Grips Rubber * Nuts and Bolts for Assembly G.I. * 3/6 Movement must be supplied with bearings Yes * Bearings Tapered Roller Bearing Ball Bearing
RequiredTapered Roller Bearing Bearings shall be self lubricating and sealed for protection against Rain and dust etc Yes * Closing Caps of open ends of the pipes
Requiredbearings
Requiredbushes and base Nylon * Thickness of closing caps ( min ) 2 * All Plastic Components U V stabilised
Requiredweather resistance * COLOUR Colour As per buyer's requirements * Paint/Finish Powder Coated
RequiredUV resistant * Paint Coating Thickness ( min ) 100 * OTHER REQUIREMENTS Ergonomic Design Yes * Moving Scope should be Limited Yes * There shall be no crushing or searing points for user between moving and/or stationary parts of equipment during use Yes * Equipment shall be free from entrapments and sharp edges Yes * Installation Instructions must be provided Yes * Installation Included Included
RequiredNot Included Safety and quality Requirements European Standard EN 16630: 2015 latest * Instruction Plate Stainless Steel
RequiredSize 150 X 230 X 0.7mm
Requiredwith indelible printing * CERTIFICATION Certfication ( Safety and Quality Requirements ) No As per European Standard EN 16630
RequiredNo Registration No and Validity of Registration 1652300310540793 * 4/6 APPROVAL Drawing depicting detailed dimensions and foundation details shall be got approved from buyer before installation
Requiredif desired by buyer Yes * WARRANTY Warranty ( years ) 3 2
Required3
Required4
Required5 * Bold specifications are the golden parameters.