Karnataka Power Transmission Corporation Limited
Akshata Kale
Tender for Increasing the vertical clearance of existing 66kV Peenya DG plant 3&4 DC line between location No.31& 32 (HTLS conductor and as per revised KPWD SR), opp. to BBMP office, Shettihalli, Jalahalli west, Bangalore by providing intermediate 66kV NBT KPTCL design tower, coming under the jurisdiction of TLM Peenya section,TLM sub-dvn, Rajajinagar, TL&SS Dvn, KPTCL, SRS Peenya, Bengaluru-58 on total turnkey basis
KPTCL/2024-25/EL/WORK_INDENT903
KPTCL/2024-25/EL/WORK_INDENT903
Open
Electrical
Two Tender Document System(Two Cover)
KPTCL SEE Transmission And Mantainance Circle BMAZ North Bengaluru
22 documents required · 21 mandatory · 1 optional
List of Financial Resources with Certificates
Should have carried out erection of all connected equipments of (01)One Transformer Bay/errection of One Transmission line tower/One Terminal Bay of 110/66kV class or above voltage class on Total Turnkey or Partial Turnkey basis, which shall be in satisfactory service for a period of One year prior to date of submission of the Bid. OR Should have carried out erection of all connected equipments of 02(Two) Transformer Bays/two Transmission line towers/ two Terminal Bays of 110/66KV class or above voltage class on Labour Contract or as Sub-Contract to any Turnkey Contractor which shall be in satisfactory service for a period of One year prior to date of submission of the Bid.
EPF certificate
PAN CARD
ESI certificate
GST Certificate
Letter of undertaking
Self declaration of not blacklisting, no litigation, no deviation
Techno commercial sheets
Bidders shall submit audited financial reports for last five years preceding the date of bid submission duly certified by Registered Charted Accountant. Minimum Average Annual Turnover (MAAT) of the bidder for best three years out of last five financial years.
Power of Attorney
The Bidder or his consortium partner should posses valid Super Grade Electrical Contractors License issued by the Government of Karnataka as on the date of Bid Submission.
Certificate is to be uploaded by the Bidder agreeing to source the equipment/material for the work from the approved Vendors who meet the eligibility clauses regarding restrictions on procurement from a country which shares a land border with India as specified in Annexure - XVIII of the tender document.
Self declaration regarding Risk & Cost.
A certificate is required to be uploaded by both Bidder and Consortium Partners separately regarding restriction on procurement from a Bidder/Consortium Partner of a country which shares a land border with India in the format as specified in the clause No.1.5 of Annexure - XVII of the Tender document.
₹1,730
₹69,110
17 Aug 2024
17 Aug 2024
9 Sept 2024
23 Aug 2024
Tender for Increasing the vertical clearance of existing 66kV Peenya DG plant 3&4 DC line between location No.31& 32 (HTLS conductor and as per revised KPWD SR), opp. to BBMP office, Shettihalli, Jalahalli west, Bangalore by providing intermediate 66kV NBT KPTCL design tower, coming under the jurisdiction of TLM Peenya section,TLM sub-dvn, Rajajinagar, TL&SS Dvn, KPTCL, SRS Peenya, Bengaluru-58 on total turnkey basis
Fabrication, galvanising and supply of mild steel tower materilas 66 kV D/C D-type with 3 meters extension Narrow based tower with stubs KPTCL design..KPTCL Common SR 2023-24 [P No 43 Sl.No.18.1]
Supply of galvanised Bolts & Nuts. KPTCL Common SR [P No 18 Sl.No.18.3]
Disc Insulator 90 KN KPTCL Common SR 2023-24 [P No 45 Sl.No.21.2.3]
Single tension fitting with Terminal pad 900A HPC conductor.KPTCL Common SR 2023-24 [P No 66 Sl.No.44.1)
HPC conductor 900A for existing Tower/Supports KPTCL Common SR 2023-24 [P No 44 Sl.No.20.10.3)
7/3.66mm G.I Wire for Ground conductor [P No.44 Sl No.20.8 ]
MSC for HPC 900A conductor.KPTCL Common SR 2023-24 [P No66 Sl No.44.6]
single tension clamp suitable for ground conductor [P No 67 Sl No.40.6.1]
M.S.C Joints for Ground conductor [P No 67 Sl No.40.6.6]
Vibration dampers for HPC 900A conductor.KPTCL Common SR 2023-24 [P No66 Sl No.44.8]
Phase plate [P No 43 Sl.No.19.1]
Number plate [P No 43 Sl.No.19.2]
Danger plate [P No 43 Sl.No.19.3]
Circuit plate [P No 43 Sl.No.19.2]
Earthing bonds 450 mm long [P No 43 Sl.No.19.4]
Sorting of tower parts made of galvanized angle iron [P No 113 Sl.No.1.1.1(a)]
Setting of stub templates and aligning, dismantling & transportation of templates [P No 113 Sl.No.1.1.1(b)]
Assembling & erection of towers including tightening of bolts & nuts including loading,unloading at store and site(Including weight of stubs)[P No.113,Sl No.1.1.1(c ) ]
Welding of bolt & nuts [P No.113,Sl No.1.1.1(e ) ]
Stringing of conductor in special conditions where normal 5 spans between anchor to anchor are not encountered,whereas anchors are provided at single/two/three spans with average span intervals of 275...
Stringing of ground conductor as above anchors are provided at three spans with average span intervals of 640 metres[P No 114 Sl.No.5.b]
Supplying & fixing of GI angle iron 45 x 45 x 5mm(1m length) with cleats, bolt & nuts as per specification and fixing above 0.5m length, each at inner & outer surface of the tower to facilitate runnin...
Supplying & fixing of barbed wire as per specification [P No 77 Sl.No.6(b)]
a) Fixing of Danger boards [P No 113 Sl.No.3(a)]
b) Fixing of Number plates [P No 113 Sl.No.3(b)]
c) Fixing of Phase plates. [P No 113 Sl.No.3(c)]
d) Fixing of Circuit plates [P No 113 Sl.No.3(d)]
Grounding of tower including cost of 40 mm dia 02.5 mm thick 'C' class GI pipe of 3m length as per specification with 50 x 6 mm GI flats 3m length, salt, charcoal including excavation charges. [P No 1...
Watch & ward: Emoluments for watch and ward including pay and DA for 8 Hrs duty [P No 95 Sl.No.38]
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Providing and laying in position Cement Concrete Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggre- gates for levelling course for all works in foundation. The granite/trap/basalt crushed...
Providing and laying in position Cement Concrete M20 Design (1:2:4) Mix Using 20 mm nominal size graded crushed coarse aggregates for all Foundation works. The granite/trap/basalt crushed graded coars...
Steel reinforcement : Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding a...
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by r...
dismantling of existing towers including loading,unloading at store and site[P No.113,Sl No.1.1.1(c ) ]
releasing of conductor in special conditions where normal 5 spans between anchor to anchor are not encountered,whereas anchors are provided at single/two/three spans with average span intervals of 275...
Releasing of ground conductor [P No 114 Sl.No.4(b)] (Rates for dismantling of materials shall be considered same as that of erection)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Tender docs.zip
Tender Document • 0.87 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .