Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹5 L
Closing Date
12 May 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHIKHA SINGH
Power Grid Corporation of India Limited Northern Region I, Regional Headquarter, SCO Bay No. 5 to 10, Sector 16A, Faridabad 121002
Civil works for Package II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
5002002265/OTHERS/DOM/I00 - NR1 RHQ -1
Open
Civil Works - Buildings
Fixed-rate
SIKAR-II Substation Taluk-Sikar, District-Sikar, Rajasthan.
₹5 L
13 Apr 2022
13 Apr 2022
13 May 2022
13 Apr 2022
12 May 2022
13 Apr 2022
2 May 2022
Name of Package Civil works for Package – II under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
Tender Enquiry Ref No.: N1/C&M/22-23/TBCB/OT/12 dtd. 13.04.2022
N1/C&M/22-23/TBCB/OT/12 dtd. 13.04.2022
1 Fill up only green shaded cells in Sch-2,3,4,5,6 and Bid Form 2nd Envelope.
2 All the cells in Sch-7, Sch-1 and Sch-1 After Discount are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
4 After filling up all the schedues, save the file, take print out of all the schedules and Bid form and sign & stamp and submit them as hard copy of the 2nd envelope (Price part) of the bid. Also ensure to submit the soft copy of the the same file on CD/ DVD.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not drag any cell value to fill down cells to it.
(vii) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Select nos. of the JV Partners other than the Lead Partner from drop down menu.
● In case of JV partners more than 2, enter details of 3rd & more partners along with details of 2nd partner.
● Fill up names and address of the Sole Bidder. Do not leave this cell blank.
● Fill up date in dd-mmm-yyyy format from drop down menu.
● Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Sch-1 to Sch-6 :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
● Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch-7 (Type Test Charges) :
● Fill up the rates & location where type tests are proposed.
● Total of this Sch-7 shall automatically appear in Sch-1.
Bid from 2nd Envelope :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the net price as per Sch-2B After Discount.
● Fill up names & Designation of the representatives of bidder.
● Fill up additional information as required.
Happy Bidding !
Civil works for Package – II under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
N1/C&M/22-23/TBCB/OT/12 dtd. 13.04.2022 Sole Bidder 1
JV (Joint Venture) 2 or More
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] Sole Bidder 0
Address of Bidder
Name of other Partner …….. …….. …….. …….. …….. ……..
Address of other Partner …….. …….. …….. …….. …….. ……..
Name of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
Address of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
N1/C&M/22-23/TBCB/OT/12 dtd. 13.04.2022 Schedule - 2
Civil works for Package – II under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C) As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-2 0.00%
Bidder’s Name and Address To: As per Percent on Sch-2 #REF!
Total Discount #REF!
Name : Contracts & Material
Address : Power Grid Corporation of India Ltd.,
SCO-5-10, Beside PCB Building, Multipackage Discount #REF!
Sector 16A, Faridabad, Haryana- 121002
(Adjacent to Metro Hospital)
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. DSR 2018 Item Ref./NS Item Description Unit Quantity Activity Number SAC Code Whether SAC in column ‘6’ is confirmed. If not indicate applicable the SAC # Rate of GST applicable (in %) Whether rate of GST in column ‘8’ is confirmed. If not indicate applicable rate of GST # (Select suitable GST rate from Dropdown) Unit Charges (Excluding GST) Total Charges (excluding GST) Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges
(I) CIVIL WORKS
A Boundary wall & Security hut 0
1.0 NS Security Hut - Civil Works All civil works as per drawing and specifications complete, including - brickwork, finishing (external and internal), windows etc. However, excavation, PCC, RCC and reinforcement shall be paid separately as per BPS. Sq.m. 18.00 995411 18.00% Included 0.18
2.0 NS SEPTIC TANK & SOAKPIT FOR SECURITY ROOM NO. 1.00 995462 18.00% Included 0.18
3.0 NS Providing and fixing Pre cast RCC Boundary wall as per drawings and specifications, including centring, shuttering, moulding,RCC, reinforcement, casting, curing, hoisting, carriage of precast cols/panels to site,Excavation, PCC, backfilling,MS angles and Concertina coil etc. complete. Grating if any required shall be paid under Misc. structural steel. RM 3,200.00 995454 18.00% Included 0.18
4.0 NS Providing and fixing main entrance gate as per drawings including Excavation, PCC, backfilling, RCC, reinforcement, MS steel, fabrication, painting etc complete LOT 1.00 995455 18.00% Included 0.18
1.0 NS 3.75m wide Bitumen road (including all crossings) complete as per drawing SQ.M. 500.00 995421 18.00% Included 0.18
2.0 NS RCC Culverts and drain crossings including supplying and laying hume pipe 250mm dia grade (NP-3) excluding Concrete as per specification M 20.00 995424 18.00% Included 0.18
3.0 NS Drain including culverts but excluding concrete & reinforcement steel - Section A-A M 250.00 995462 18.00% Included 0.18
4.0 NS Drain including culverts but excluding concrete & reinforcement steel - Section B-B M 50.00 995462 18.00% Included 0.18
C Store Building 0
1.0 NS Pre Engineered building closed Store for AIS spares: Design preparation of shop drawings, supply of all materials, fabrication, erection & commissioning of PEB Store Building. The work includes design and construction of foundations, plinth beams, brickwork, external & internal finishing, floor finishing, doors, windows, rolling shutters etc. complete in all respects as per the approved design, drawings and Technical specifications. However, excavation, PCC, RCC and reinforcement shall be paid under relevant item of BPS. Sq.m. 360.00 995413 18.00% Included 0.18
2.0 NS Pre Engineered building partially closed Store for AIS spares: Design preparation of shop drawings, supply of all materials, fabrication, erection & commissioning of PEB Store Building. The work includes design and construction of foundations, plinth beams, brickwork, external & internal finishing, floor finishing, doors, windows etc. complete in all respects as per the approved design, drawings and Technical specifications. However, excavation, PCC, RCC and reinforcement shall be paid under relevant item of BPS. Note: Opening detail as per TS Cl. 9.3.3 sq.m 360.00 995413 18.00% Included 0.18
D Common Items for A to C (as applicable) 0
1.0 NS Excavation in all types of soil and rock including backfilling disposal etc.for all leads and lifts Cu.Mtr. 1,695.00 998739 18.00% Included 0.18
2.0 NS Providing and laying of Plain Cement Concrete (PCC) (1:4:8) Cu.Mtr. 153.80 995454 18.00% Included 0.18
3.0 NS Providing and laying of Plain Cement Concrete (PCC) (1:2:4) Cu.Mtr. 35.00 995454 18.00% Included 0.18
4.0 NS Providing and laying of Reinforced Cement Concrete M-25 including pre cast, shuttering, Grouting of pockets & underpinning but excluding steel reinforcement Cu.Mtr. 545.00 995421 18.00% Included 0.18
5.0 NS Steel Reinforcement MT 54.50 995454 18.00% Included 0.18
6.0 NS Misc. Structural steel including rails, embedments, edge protection angles, gratings etc. but excluding the reinforcement steel and steel for lattice and pipe structures. MT 1.75 995455 18.00% Included 0.18
(II) ELECTRICAL WORK
1.0 1.10.2 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B Point 34.00 995461 18.00% Included 0.18
2.0 1.12 Wiring for light / power plug with 2X4 Sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Metre 60.00 995461 18.00% Included 0.18
a 1.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Metre 160.00 995461 18.00% Included 0.18
a 1.18.2 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair Metre 200.00 995424 18.00% Included 0.18
5.0 1.19 Supplying and drawing co-axial cable TV RG-6 grade 0.7mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required. Metre 200.00 995424 18.00% Included 0.18
a 1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm Metre 200.00 995461 18.00% Included 0.18
a 1.22.2 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 100 mm X 100 mm X 60 mm deep Each 4.00 995461 18.00% Included 0.18
a 1.24.1 5 amps switch Each 16.00 995461 18.00% Included 0.18
1.24.A 6 amp switch Each 4.00 995461 18.00% Included 0.18
b 1.24.4 3 pin 5/15 amp socket outlet Each 20.00 995461 18.00% Included 0.18
c 1.24.6 Telephone socket outlet Each 4.00 995461 18.00% Included 0.18
d 1.24.7 T.V. antenna socket outlet Each 3.00 995461 18.00% Included 0.18
9.0 1.25 Suplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Each 7.00 995461 18.00% Included 0.18
a 1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75 mm X 75 mm) Each 20.00 995461 18.00% Included 0.18
1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100 mmX75 mm) Each 10.00 995461 18.00% Included 0.18
11.0 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required. Each 4.00 995461 18.00% Included 0.18
12.0 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required. Each 4.00 995461 18.00% Included 0.18
13.0 1.38 Supplying and fixing call bell/ buzzer suitable for D.C./A.C. single phase, 230 volts, complete as required. Each 2.00 995461 18.00% Included 0.18
14.0 1.41 Installation, testing and commissioning of pre-wired, fluorescent fitting/LED/ compact fluorescent fitting of all types, comlete with all accessories and tube etc. directly on celing/ wall, including connection with 1.5 Sq. mm FR PVC insulated, copper conductor, sigle core cable and earthing etc; as required. Each 11.00 995461 18.00% Included 0.18
15.0 1.35 Erection of wall bracket/ceiling fittings of all sizes and shapes containing LED lamps per fitting, complete with all accessories including connection etc. as required. Each 9.00 995461 18.00% Included 0.18
16.0 1.45 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 Sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. Each 4.00 995461 18.00% Included 0.18
a 1.50.1 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Up to 450 mm sweep Each 1.00 995461 18.00% Included 0.18
18.0 1.51 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. Each 1.00 995461 18.00% Included 0.18
19.0 2.4.3 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way SPN Each 2.00 998736 18.00% Included 0.18
20.0 2.10.1 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole Each 16.00 998736 18.00% Included 0.18
21.0 2.13.3 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 amps 4 P Isolator Each 2.00 998736 18.00% Included 0.18
22.0 2.21 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Each 2.00 998736 18.00% Included 0.18
23.0 5.11 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with GI nut, bolt, spring, washer excavation and re-filling etc. as required. Metre 20.00 998739 18.00% Included 0.18
a 14.16.5 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 200 mm dia (OD-200 mm & ID-175 mm nominal) Metre 20.00 995461 18.00% Included 0.18
25.0 CIVIL DSR 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3mm dia, round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing. each 8.00 995476 18.00% Included 0.18
26.0 NS Supply installation, testing and commissioning of Krone type tag block of 10 pair complete with back mount frame, modules, etc in a lockable metal box including connection etc, as required Each 2.00 995476 18.00% Included 0.18
a NS Supplying and fixing 18W LED tube essential on batten (Cat No. TMC 501 P1& T LED 22W P3241 for batten & Cat No. Essential Led tube M/s Philips & Similar. Each 11.00 995476 18.00% Included 0.18
b NS Supplying and fixing 10 Watt LED recess down lighter round ( philips cat No. DN 191B LED 65-4000 PSU WHSI or similar Each 2.00 995476 18.00% Included 0.18
c NS Surface mounted 1x11 Watt CFL mirror Lights fitting Bajaj Cat No. BJC111 WEBI or similar. Each 2.00 995476 18.00% Included 0.18
d NS 33W LED recess square fitting similar to Philips Cat No. RC370B LED 285 6500 Each 2.00 995476 18.00% Included 0.18
NS BL(Surface Mounted Bulk Head) 18W fitting Philips or similar approved 6.00 995476 18.00% Included 0.18
a NS Supplying and fixing FAN - 1200 mm sweep Each 7.00 995476 18.00% Included 0.18
a NS Supplying and fixing 300 mm ventilating Fan Each 2.00 995476 18.00% Included 0.18
30.0 NS Supply and installation of wall bracket fan of 300mm, sweep complete with fan motor, blades etc. with all accessories etc. of approved make as required.(Make : Bajaj / Crompton / Havells) Each 2.00 995476 18.00% Included 0.18
Total Civil + Electrical Portion Charges (excluding GST) 0.00
Total GST Amount for Civil + Electrical Portion 0.00 #REF!
1 Total charges
2 Total Amount including all taxes & duties 0.00
Place : 00-Jan-00 Printed Name :
00-Jan-00 Designation :
N1/C&M/22-23/TBCB/OT/12 dtd. 13.04.2022 Schedule - 3
Civil works for Package – II under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C) As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-2 0.00%
Bidder’s Name and Address To: As per Percent on Sch-2 #REF!
Total Discount #REF!
Name : Contracts & Material
Address : Power Grid Corporation of India Ltd.,
B-9, Qutab Institutional Area, Multipackage Discount #REF!
Katwaria Sarai,
New Delhi-110016
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. DSR Ref Description Unit Quantity SAC Code WhetherHSN in column ‘5’ is confirmed. If not indicate applicable theHSNC # Rate of GST applicable ( in %) Whether rate of GST in column ‘7’ is confirmed. If not indicate applicable rate of GST # (Select suitable GST rate from Dropdown) Unit Charges (Excluding GST) Total Charges (excluding GST) Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges
Sub-head-I 11 KV H.T. Out door items 0
1 13.13 Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 kV overhead lines with rated voltage 9 kV (rms) with a nominal discharge current rating of 5 kA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. set 3.00 998739 18% Included 0.18
2 13.1 Supplying and erection of 11 kV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. each 3.00 998739 18% Included 0.18
Sub-head-II Cable & Pipes 0
3 14.16.1 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required: 63 mm dia (OD-63 mm & ID-51 mm nominal) Mtr 75.00 995424 18% Included 0.18
4 14.16.2 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required: 90 mm dia (OD-90 mm & ID-76 mm nominal) Mtr 20.00 995424 18% Included 0.18
5 14.16.5 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required:200 mm dia (OD-200 mm & ID-175 mm nominal) Mtr 10.00 995424 18% Included 0.18
6 DSR'16 (Civil) 19.7.1.1 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement :4 coarse sand) RCC top slab with 1:2:4 mix ( 1 cement :2 coarse sand:4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement :4 coarse sand:8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : coarse sand :4 graaded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per stnadard design: Inside size 30x30 cm and and 45 cm deep including C.I. cover with frame (light duty) 500 mm internal diameter , total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg): With common burnt clay FPS ( non modular) bricks of class designation 7.5 each 10.00 995424 18% Included 0.18
7 10.1.2 Supplying and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required: 120 sq. mm Each 2.00 998739 18% Included 0.18
8 9.1.25 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required: 2x6 sq. mm Each 156.00 998739 18% Included 0.18
9 9.1.32 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required:4x10 sq. mm Each 2.00 998739 18% Included 0.18
10 9.1.20 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required: 3.5x25 sq.mm (28 mm) Each 8.00 998739 18% Included 0.18
11 9.1.21 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required: 3½ X 35 sq. mm (32 mm) Each 6.00 998739 18% Included 0.18
12 9.1.23 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required:3.5 x 70 sq. mm Each 2.00 998739 18% Included 0.18
13 9.1.33 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required: 4x16 sq. mm Each 2.00 998739 18% Included 0.18
14 7.1.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required: Upto 35 sq. mm Mtr 1847.00 998739 18% Included 0.18
15 7.1.2 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required: Above 35 sq. mm and up to 95 sq. mm Mtr 110.00 998739 18% Included 0.18
16 7.1.4 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required: Above 185 sq. mm and up to 400 sq. mm Mtr 140.00 998739 18% Included 0.18
17 7.2.1 Laying of one number additional PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation inclucing excavation, sand cushioning, protective covering and refilling the trench etc. as required: Up to 35 sq. mm Mtr 173.00 998739 18% Included 0.18
18 7.5.1 Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required: Up to 35 sq. mm Mtr 195.00 998739 18% Included 0.18
19 7.5.2 Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required: Above 35 sq. mm and up to 95 sq. mm Mtr 5.00 998739 18% Included 0.18
20 7.5.4 Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required: Above 185 sq. mm and up to 400 sq. mm Mtr 5.00 998739 18% Included 0.18
21 7.6.1 Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1KV grade of following size in the existing masonry open duct as required: Upto 35 sq. mm Mtr 95.00 998739 18% Included 0.18
22 7.6.2 Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1KV grade of following size in the existing masonry open duct as required: Above 35 sq. mm and up to 95 sq. mm Mtr 5.00 998739 18% Included 0.18
23 7.6.4 Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1KV grade of following size in the existing masonry open duct as required: Above 185 sq. mm and up to 400 sq. mm Mtr 5.00 998739 18% Included 0.18
24 7.7.1 Laying and fixing of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 kV grade of following size on wall surface as requred: Upto 35 Sq. mm (clamped with 1 mm thick saddle) Metre 5.00 998739 18% Included 0.18
25 8.1.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required: Upto 120 sq. mm Mtr 40.00 998739 18% Included 0.18
26 8.3.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required: Upto 120 sq. mm Mtr 10.00 998739 18% Included 0.18
Sub-head-III Earthing 0
27 5.2 Earthing with G.I. pipe 4.5 metre long 40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. Each 7.00 998739 18% Included 0.18
28 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Sets 12.00 998739 18% Included 0.18
29 5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. Set 2.00 998739 18% Included 0.18
30 5.1 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. Mtr 10.00 998739 18% Included 0.18
31 5.11 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required. Mtr 50.00 998739 18% Included 0.18
32 5.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I wire in 15 mm dia G.I pipe FRLSom earth electrode including conneciton with G.I thimble excavation and re-filling as required. Mtr 35.00 998739 18% Included 0.18
33 5.18 Providing and fixing 6 SWG dia G.I wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required. Mtr 3800.00 998739 18% Included 0.18
Non-Scheduled items 0
Sub-head-IV 11 KV H.T. Out door items :- 0
34 NSEC-1 Supply and erection of 152.x152 mm 9 mtr. long H beam steel pole (37.1 kg/meter) in cement concrete foundation 1:3:6 ( 1 cement: 3 coarse sand: graded stone aggregate 40mm nominal size) including excavation aligning, keeping the pole in vertical position, painting with one coat of red oxide (primer), secured with holding clamps nuts and bolts, confirming to relevant ISS etc. as required. each 2 998731 18% Included 0.18
35 NSEC-2 Supply and fixing of following sizes of Angle/channel/flat iron in the pole structure for mounting of lighting arrestors, A.B. switches, D.O. fuse assembles, Disc insulators, pin and post insulators.P.T. & cable end box etc. complete with G.I. Nuts, bolts, washers making of holes and other required materials painting with one coat of red oxide etc. as required. (i)M.S. channel (100 x 50mm); (ii)M.S. angle iron ( 50x50x6mm); (iii) M.S. flat iron (80x6mm) for clamps; (iv) M.S. plate 7mm thick (for mounting of lightning arrestors). [Note: Cost of lightning arrestors AB switches etc. not to be included in this item] kg 400 998731 18% Included 0.18
36 NSEC-3 Painting of one no. 2 pole structure complete with members including clamps, brackets,nuts,bolts and washers with additional one coat of red oxide (primer) and two coats of aluminium paint of approved make etc. as required. job 1 998731 18% Included 0.18
37 NSEC-4 Supply and fixing anti climbing device made of G.I. Barbed wire confirming to ISS 278-1960 having 4 points barbs 12.5 kg/100m size wrapped helically with a pitch of 75mm on the existing poles for height 1.5m commencing from 3.5m from ground with suitable clamps at the end as required. each 2 998731 18% Included 0.18
38 NSEC-5 SOR-SS (July'18) Supplying, spreading and dressing of 40mm nominal size (ungraded single size) conforming to Table 2 of IS:383-1970 with abrasion value < 40%; Impact value < 30%; Flakiness Index < 25% in the existing H.T. yard etc. as required. cum 8 995428 18% Included 0.18
39 NSEC-6 Supplying and erection (one set of three numbers) of 200 Amps.11 KV A.C. supply system H.T. gang operated air break isolating switch assembly (tilting type) with phosphor bronze/tinned copper contacts complete with operating handle of suitable length with square bar handle including pad locking arrangement and other G.I. hardware fittings confirming to relevant I.S. specifications and fixing the same on the existing pole structure on channels and clamps including making connections, testing and commisssioning etc. as required. set 1 998736 18% Included 0.18
40 NSEC-7 Supplying and erection (one set of three Nos.) of 11 KV dropout fuse unit assembly vertical mounting complete with fuse barrel, fuses and other G.I. Hardware fittings confirming to relevant ISS & fixing the same on the existing pole structure including making of connections, testing and commissioning etc. as required. set 1 998736 18% Included 0.18
41 NSEC-8 Supply, installation, testing and commissioning of outdoor type transformer of 400 KVA capacity ONAN type with copper winding having a continuous rating of 11 KV/433 V 3 phase 50 Hz. Vector group Dy N 11 having 3x120 sq. mm 11 KV u.g cable on H.V.side and 1 No. 3.5 core 300 sq.mm underground cable on 433 volts side, with all fittings and accesories off load tap changer for - 7.5% to + 7.5% of 2.5 each complete with filtered oil etc.and outdoor foundation plate form complete confirming to section 3 of CPWD General specifications for electrical works (part IV sub-station) 2013. set 1 998736 18% Included 0.18
42 NSEC-9 Supplying and drawing of ACSR Raccoon conductor of approved make including stringing and making complete with binding at existing insulator jointing jumpering teeing of connections etc. as required. mtr 20 995468 18% Included 0.18
Sub-head-V L.T Panel & Feeder Pillar 0
43 NSEC-10 Supplying, installation, testing and commissioning of cubicle type LT panel suitable for 415 V, 3 Phase, 4 wire 50 HZ AC supply system fabricated in comparmentalized ( preferable) design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick fro gland, plates i/c cleaning and finishing complete with 7 tank process for powder coating in approved shade, having 3000Amp capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC/SMC bus bars of high conductivity, DMC/SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 sec, bottom base channel of MS section not less than 100 mm x 50 mm x5 mm at the rear with 2 nos. earth stud, solid connectons from main bus bar to switch gears with required size of Al. bus bars and control wiring with 2.5 sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plated in two hald, i/c providing following switch gears:- (I) Incoming-2 Nos. four pole MCCB of fault breaking capacity 50 KA (Ics=Icu up to 433V) , fitted with interlocked door,complete with following accessories for each MCCB. (a)800A 4P MCCB- 1 no. for normal supply (b)630A 4P MCCB - 1 no. for DG supply (c)Analog 96 mm square /Digital* type volmeter (0-500V), with selector switch and back up / MCBs- 1 set. (d)Analog 96 mm. square /Digital* type Ammeter (0- 800Amp), with selector switch and one set of 3 nos. CT's of ratio 800 /5A Class I accuracy and 15 VA burden- 1 set . (e)3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker 'ON' indicated light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. (II) Bus Couplers:-1 No. 800 Amps 4 Pole MCCB of fault breaking capacity 50 KA (Ics-Icu up to 433 V) complete. (III)Bus Bars:- TPN aluminium bus bars of minimum of 1000 Amps capacity with heat shrinkabel coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 sec. (IV) Interlocking:-Electrical throuth advance contacts in MCCBs (incomers & bus coupler) and mechanical ( castel key) interloking should be provided to ensure that only one supply is available at a time on each section of bus and to eliminated any possibility of accidentally approaching two supplies at one bus section. (V) Outgoing: (a) 200A 4 P MCCB 35 KA - 5 nos. (b)100 A 4 P MCCB - 25 KA - 5 nos. (c)63A 4P MCCB 25 KA 1 no. set 1.00 998736 18% Included 0.18
Feeder Pillar for compound lights 18% 0.18
44 NSEC-11 Supply, installation, testing and commissioning of cubicle type feeder pillar (out -door type) suitable for 415 V. 3 ph. 4 wire 50 Hz AC Supply system fabricated in compartmentalizer (preferably) design from CRCA sheet steel 2 mm thick for frame work and covers 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade having 200amps capacity extensible type TPN aluminium alloy bus bars, bottom base channel of MS section not less than 100 mm x 50mmx5 mm thick complete with 2 nos. earth stud the control wiring shall be with 2.5 sq. mm PVCinsulated copper conductor s/c cable complete with cable alloys, cable gland plates in two half i/c providing following switch gears. (A) Incomer- (i)63 Amp 4P MCCB 25 KA- 1 no (ii)40 Amps astronomical time switch for automatic switching On & OFF of compound Lights (Auto ON, Auto OFF, Auto modes) with manual over ride facility with 12/24 hrs. display format with suitable battery and indications for relay status i/c programming at site complete as required (B)Outgoing-6-15 Amp DP MCB 10 KA - 15 nos. Set 1.00 998736 18% Included 0.18
Feeder Pillar for Quarters 18% 0.18
45 NSEC-12 Supply, installation, testing and commissioning of cubicle type feeder pillar (out -door type) suitable for 415 V. 3 ph. 4 wire 50 Hz AC Supply system fabricated in compartmentalizer (preferably) design from CRCA sheet steel 2 mm thick for frame work and covers 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade having 400amps capacity extensible type TPN aluminium alloy bus bars, bottom base channel of MS section not less than 100 mm x 50mmx5 mm thick complete with 2 nos. earth stud the control wiring shall be with 2.5 sq. mm PVC insulated copper conductor s/c cable complete with cable alloys, cable gland plates in two half i/c providing following switch gears. (A)Incomer- 200A 4P MCCB 35KA-1 no (B)Outgoing-100A 4P MCCB 25 KA- 2 nos.; 63A 4P MCCB 25KA - 6 nos Set 1.00 18% Included 0.18
AUTOMATIC POWER FACTOR CORRECTION PANEL 0
46 NSEC-13 Design, manufacture, supply, storing, inspection, handling, assembling, installation in correct alignment, position, affecting proper connections, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical type 125 KVAR A P F C Panel APP/Mdxl type consisting of, one no. 50 KVAR 2 nos. 25 KVAR and 2 nos. 12.5 KVAR complete with 1 no 8 step APFC relay etc., in tier formation, housed in an integrated cubicle type automatic switching ON and OFF control panel, floor mounting, dust & virmin proof, front operated construction, enclosure class - IP 52, Painting by one coat of red oxide primer with two coats of approved synthetic enamel paint complete with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2,5 sq. mm. copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 440 Volts, 3 phase 50 Hz, suitable capacitor duty contineous to be used for switching etc., as required. SET 1.00 998736 18% Included 0.18
Sub-Head-VI Cable & Pipes 0
47 NSEC-14 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required: 3.5 x 300 sq. mm Each 2.00 998739 18% Included 0.18
48 NSEC-15 Suppy of 3 core 120 sq.mm standard aluminium conductor 11 KV grade XLPE (E) insulated PVC sheathed galvanised flat steel sheet armoured cable conforming to IS 7098 (Pt-II with latest amendment) Mtr 50.00 998739 18% Included 0.18
49 NSEC-16 Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098 armored secured Sheathed 1100 volts grade as required: 3.5x300 sq. mm Mtr 150.00 998739 18% Included 0.18
50.00 NSEC-17 Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098 armored secured Sheathed 1100 volts grade as required:3.5x70 sq. mm Mtr 120.00 998739 18% Included 0.18
51.00 NSEC-18 Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098 armored secured Sheathed 1100 volts grade as required: 3.5x35 sq. mm Mtr 500.00 998739 18% Included 0.18
52.00 NSEC-19 Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098 armored secured Sheathed 1100 volts grade as required: 3.5x25 sq. mm Mtr 200.00 998739 18% Included 0.18
53.00 NSEC-20 Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098 armored secured Sheathed 1100 volts grade as required: 4x16 sq. mm Mtr 60.00 998739 18% Included 0.18
54.00 NSEC-21 Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098 armored secured Sheathed 1100 volts grade as required: 4x10 sq. mm Mtr 5.00 998739 18% Included 0.18
55 NSEC-22 Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098 armored secured Sheathed 1100 volts grade as required:2x6 sq. mm Mtr 1550.00 998739 18% Included 0.18
Sub-Head-VII Compound Light Fittings 0
56 NSEC-23 Supply, installation, testing and commissioning of 40 watt LED street light fitting IP 66 suitable for installation on 6 mtr high existing pole complete with IP 66 control gear in separate compartment , extruded aluminium painted housing, a toughened glass protector etc., as required (Make-PHILIPS) each 15.00 998739 18% Included 0.18
57 NSEC-24 Supply, installation, testing and commissioning of 150 W LED street light fitting IP 66 suitable for installation street light fitting IP 66 suitable for installation on 6 mtr high existing pole complete with IP 66 control gear in separate compartment , extruded aluminium painted housing, a toughened glass protector etc., as required (Make-PHILIPS) each 4.00 998739 18% Included 0.18
58 NSEC-25 Supply, installation, testing and commissioning of 40W LED Post top luminaire sealed to IP 66 and impact resistance complete with aluminium housing a canopy and high impact polycarbonate protector etc., complete as required (Make-PHILIPS) each 30.00 998739 18% Included 0.18
59 NSEC-26 Supply, installation, testing and commissioning of 14 Watt LED prewired Bollard Lights complete with protector etc., as required to cat No. Bollard LED 14w-NW-Monichromatic. (Make-PHILIPS) each 23.00 998739 18% Included 0.18
60 NSEC-27 Supply, installation, testing and commissioning of base mounted above ground 6 meter long tubular G.I. pole along with single side 500 mm bracket suitable for installing 40/150 watt LED street light fitting. Bottom of the pole shall be 127 mm dia till 1 meter and 76 mm dia for 5 meter along with 16 mm thick base plate of size 300 mm x 300 mm. The column shall also be provided with flush door at the bottom with junction /looping box along with heavy duty connector etc., complete as required to cat No. Brika Pole & bracket of M/s Keselec- Schreder. each 19.00 998739 18% Included 0.18
61 NSEC-28 Supply, installation, testing and commissioning of base mounted above ground 4 meter long tubular G.I. Pole of 114mm dia throughout & baseplate of size 300 mm x300 mm complete with flush door at the bottom with junction /laying box with H.D. connector etc., complete as required to Cat No. Cornaline pole M/s Keselec schreder or similar. each 30.00 998739 18% Included 0.18
62 NSEC-29 40 W HP LED fixture solar street lighting system complete with electrical & electronic accessories and 6.0 mtr light G.I. painted pole complete with 200W solar panel 150 Ah Battery, charging and converter kit and battery box etc/, having back up for more than 10 hrs. as day once fully charged similar to Cat no. Light Master India (LMI)1 Oorja technologies/SU-kam. nos 7.00 998739 18% Included 0.18
Total Charges (Excluding Tax) 0.00
Total GST on Price 0.00 #REF!
1 Total charges
2 Total Amount including all taxes & duties 0.00
Place : 00-Jan-00 Printed Name : 0
Designation : 0
N1/C&M/22-23/TBCB/OT/12 dtd. 13.04.2022 Schedule - 4
Civil works for Package – II under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C) As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-2 0.00%
Bidder’s Name and Address To: As per Percent on Sch-2 #REF!
Total Discount #REF!
Name : Contracts & Material
Address : Power Grid Corporation of India Ltd.,
B-9, Qutab Institutional Area, Multipackage Discount #REF!
Katwaria Sarai,
New Delhi-110016
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. DSR Ref Description Unit Quantity SAC Code WhetherHSN in column ‘5’ is confirmed. If not indicate applicable theHSNC # Rate of GST applicable ( in %) Whether rate of GST in column ‘7’ is confirmed. If not indicate applicable rate of GST # (Select suitable GST rate from Dropdown) Unit Charges (Excluding GST) Total Charges (excluding GST) Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges
1 1.10.1 Wiring for light point / fan point / exhaust fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sq.mm. FRLS PVC insulated copper conductor single core cable etc as required: Group A Point 175 995461 18% Included 0.18
2 1.10.2 Wiring for light point / fan point / exhaust fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sq.mm. FRLS PVC insulated copper conductor single core cable etc as required: Group B Point 476 995461 18% Included 0.18
3 1.12 Wiring for light / power plug with 2X4 Sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Metre 830 995461 18% Included 0.18
4 1.13 Wiring for light/power plug with 4X4 Sq. mm FRLS PVC insulated copper conductor single core cablein surface/ recessed medium class PVC conduit alongwith 2 Nos 4 Sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Metre 626 995461 18% Included 0.18
5 1.14.1 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required: 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Metre 1219 995461 18% Included 0.18
6 1.14.4 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required:2 X 6 sq. mm + 1 X 6 sq. mm earth wire (For MCB Socket) Metre 1012 995461 18% Included 0.18
7 1.14.5 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.: 2 X 10 sq. mm + 1 X 6 sq. mm earth wire Metre 155 995461 18% Included 0.18
8 1.14.6 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required: 2 X 16 sq. mm + 1 X 6 sq. mm earth wire Metre 75 995461 18% Included 0.18
9 1.14.11 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required: 4 X 16 sq. mm + 2 X 6 sq. mm earth wire Metre 5 995461 18% Included 0.18
10 1.18.2 Supplying and drawing following pair, 0.5 Sq. mm FRLS PVC insulated copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required: 2 Pair Metre 620 995461 18% Included 0.18
11 1.19 Supplying and drawing co-axial TV Cable RG-6 grade 0.7mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required. Metre 710 995461 18% Included 0.18
12 1.21 Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same incase of recessed conduit as required for telephone and TV Points: 25mm Metre 1335 995461 18% Included 0.18
13 1.22.2 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated seet cover in front including painting etc as required: 100 mm X 100 mm X 60 mm deep Each 16 995461 18% Included 0.18
14 1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required: 5/6 amps switch Each 45 995461 18% Included 0.18
15 1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required: 3 pin5/6 amp socket outlet Each 45 995461 18% Included 0.18
16 1.24.6 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required:Telephone socket outlet Each 40 995461 18% Included 0.18
17 1.24.7 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required:T.V. antenna socket outlet Each 65 995461 18% Included 0.18
18 1.24.8 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required:Bell Push Each 17 995461 18% Included 0.18
19 1.25 Suplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Each 105 995461 18% Included 0.18
20 1.27.1 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular plate as required (for telephone and T.V. socket): 1 or 2 Module (75 mm X 75 mm) Each 105 995461 18% Included 0.18
21 1.27.2 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular plate as required (for telephone and T.V. socket): 3 Module (100 mmX75 mm) Each 45 995461 18% Included 0.18
22 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required. Each 109 995461 18% Included 0.18
23 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required. Each 70 995461 18% Included 0.18
24 1.38 Supplying and fixing call bell/ buzzer suitable for D.C./A.C. single phase, 230 volts, complete as required. Each 17.00 995461 18% Included 0.18
25 1.41 Installation, testing and commissioning of pre-wired, fluorescent fitting/LED/ compact fluorescent fitting of all types, comlete with all accessories and tube etc. directly on celing/ wall, including connection with 1.5 Sq. mm FR PVC insulated, copper conductor, sigle core cable and earthing etc; as required. Each 92 995461 18% Included 0.18
26 1.35 Erection of wall bracket/ceiling fittings of all sizes and shapes containing LED lamp per fitting, complete with all accessories including connection etc. as required. Each 393 995461 18% Included 0.18
27 1.45 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 Sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. Each 105 995461 18% Included 0.18
28 1.50 Installation of exhaust fan in the existng opening, including making good the damage, connection, testing , commissioning etc. as required: Up to 450 mm sweep Each 54 995461 18% Included 0.18
29 1.51 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. Each 54 995461 18% Included 0.18
30 1.57 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. Each 35 995461 18% Included 0.18
31 2.3.2 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator): 8 way , Double door Each 5 998736 18% Included 0.18
32 2.3.4 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator): 16 way, Double door Each 10 998736 18% Included 0.18
33 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator): 8 way (4+24), Double door Each 1 998736 18% Included 0.18
34 2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240 volts, 'C' series, miniature circuit brealer suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required: Single pole Each 194 998736 18% Included 0.18
35 2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required: 40 amps Each 5 998736 18% Included 0.18
36 2.14.3 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required: 63 amps Each 10 998736 18% Included 0.18
37 2.15.3 Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required: 63 amps Each 1 998736 18% Included 0.18
38 2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts''C'' curve DP MCB complete with connections , testing and commissioning etc. as required. ( For stair Lights) Each 15 998736 18% Included 0.18
39 2.18 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Each 38 998736 18% Included 0.18
40 2.21 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Each 16 998736 18% Included 0.18
41 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal or coke and salt as required. Set 17 998739 18% Included 0.18
42 5.11 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with GI nut, bolt, spring, washer excavation and re-filling etc. as required. Metre 50 998739 18% Included 0.18
43 14.6.5 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required: 200 mm dia (OD-200 mm & ID-175 mm nominal) Metre 35 995424 18% Included 0.18
44 DSR'Civil 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3mm dia, round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing. each 105 995476 18% Included 0.18
Non-Scheduled Items 0
45 NSE-1 Supplying, installation, testing and commissioning of KRONE type tag block of 10pairs complete with back mount frame, modules, etc in a lockable metal box including connection, etc as required. Each 16 995461 18% Included 0.18
46 NSE-2 Supply installation testing and commissioning of cubical type compartmentalized meter board for 4 meters, made of 1.6mm thick sheet steel, duly powder coated, integral loose wire box complete with 1 no 63 Amp 4 Pole 25 KA MCCB, insulated copper bus bars, 200 amps capacity. Each meter having one No. 40 Amp 2 Pole MCB, with single phase 230 Volts10/40 amp energy meter, prewired from bus bar upto connector block (for each quarter) in loose wire box/cable alloy, locking/ceiling arrange ment for each compartment ) bus bar chamber etc., as required. set 15 998736 18% Included 0.18
47 NSE-3 Supply, Installation, Testing & Commissioning of following LED light fixture with high efficiency with Driver , tubes/lamps, reflector, diffuser, body/housing holder etc. complete with all fixing accessories as required: 1 x 18 W LED light fixture (Philips LED 31084/31 Shellline ,6500K PSE OD GR with minimum system lumen 1600 or approved equivalent from list of Makes)(120bw ) each 28 998739 18% Included 0.18
48 NSE-4 Supply, Installation, Testing & Commissioning of following LED light fixture with high efficiency with Driver , tubes/lamps, reflector, diffuser, body/housing holder etc. complete with all fixing accessories as required: 1 x 20 W LED box type light fixture (Philips BN108C LED 20S PSU CDL WH including Mounting Accessories, with minimum system lumen 2100 or approved equivalent from list of Makes )(136b/ 136bw) each 18 998739 18% Included 0.18
49 NSE-5 Supply, Installation, Testing & Commissioning of following LED light fixture with high efficiency with Driver , tubes/lamps, reflector, diffuser, body/housing holder etc. complete with all fixing accessories as required: LED Surface mounted light fixture (Philips SP824P LED 29S-5000 GR OD or Cromptom LCTLS-40-CDL as per requirment with minimum system lumen 3000 or approved equivalent from list of Makes)(236SM01) each 29 998739 18% Included 0.18
50 NSE-6 Supply, Installation, Testing & Commissioning of following LED light fixture with high efficiency with Driver , tubes/lamps, reflector, diffuser, body/housing holder etc. complete with all fixing accessories as required.:- 1 x 10 W wall Bracket (Philips LED-1 x 10 W 45617/17 Vase or approved equivalent from list of Makes)(WB) each 112 998739 18% Included 0.18
51 NSE-7 Supply, Installation, Testing & Commissioning of following LED light fixture with high efficiency with Driver , tubes/lamps, reflector, diffuser, body/housing holder etc. complete with all fixing accessories as required.:- 1 x 10 W Bulk Head light fixture (Philips WT202 W LED 6S CW PSU S1 PC or approved equivalent from list of Makes) (BH) Each 8 998739 18% Included 0.18
52 NSE-8 Supply, Installation, Testing & Commissioning of following LED light fixture with high efficiency with Driver , tubes/lamps, reflector, diffuser, body/housing holder etc. complete with all fixing accessories as required.:- Mirror LED light (Catalogue :Philips 340341486 7.5-Watt LED wall light (silver) Each 153 998739 18% Included 0.18
53 NSE-9 Supply, Installation, Testing & Commissioning of following LED light fixture with high efficiency with Driver , tubes/lamps, reflector, diffuser, body/housing holder etc. complete with all fixing accessories as required.:- Chandeliar- Antique design brass 5 portugese style antique golden chandeliar with 5 lamps (Item shape-Round), Item part no. DFCA 44560) or Equivalent (Base cost of chandeliar= Rs. 3600.00 (Including GST) Each 1 998739 18% Included 0.18
54 NSE-10 Supply, Installation & Testing Commssioning of following ceiling fans (BEE-5 Star rated) complete with double ball bearing, motor, blades, downrod, Canopies, capacitor suitable for operation on 230Volts, 50Hz, 1 Phase AC supply complete as required: 1200 mm sweep (With regulator) Each 64 998731 18% Included 0.18
55 NSE-11 Supply, Installation & Testing Commssioning of following ceiling fans (BEE-5 Star rated) complete with double ball bearing, motor, blades, downrod, Canopies, capacitor suitable for operation on 230Volts, 50Hz, 1 Phase AC supply complete as required: 1400 mm sweep (Without regulator) Each 41 998731 18% Included 0.18
56 NSE-12 Supply, Installation and commissioning of metal type exhaust fans suitable for 220/240 Volts 50 Hz. Ac supply of 900 RPM single Phase AC supply complete with ,shutter etc; as required: 380 mm sweep (Make : Orient/Bajaj / Crompton / Havells or equivalent) Each 54 998731 18% Included 0.18
57 NSE-13 Supply and installation of wall bracket fan of 400mm(fan size) , complete with fan motor, blades etc. with all accessories etc. of approved make as required. (Make : Orient/Bajaj / Crompton / Havells or equivalent) Each 7 998731 18% Included 0.18
Total charges (Excluding Tax) 0.00
1 Total GST on Price 0.00 #REF!
2 Total charges
3 Total Amount including all taxes & duties 0.00
Place : 00-Jan-00 Printed Name : 0
Designation : 0
N1/C&M/22-23/TBCB/OT/12 dtd. 13.04.2022 Schedule - 5
Civil works for Package – II under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C) As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-2 0.00%
To: As per Percent on Sch-2 #REF!
Bidder’s Name and Address Contracts & Material Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : B-9, Qutab Institutional Area,
Katwaria Sarai, Multipackage Discount #REF!
New Delhi-110016
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. DSR Ref Description Unit Quantity Activity Number SAC Code (Service Accounting Codes) Whether SAC in column ‘5’ is confirmed. If not indicate applicable the SAC # Rate of GST applicable ( in %) Whether rate of GST in column ‘7’ is confirmed. If not indicate applicable rate of GST # (Select suitable GST rate from Dropdown) Unit Charges (excluding Tax) Total Installation Charges (excluding Tax) Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges
Sub-head-I EXTERNAL WATER SUPPLY 0
1 18.9.6 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings.This includes jointing of pipes and fittings with one step CPVC solvent cement , trenching, refilling & testing of joints complete as per direction of Engineer in Charge: 50 mm nominal outer dia Pipes Metre 175.00 120002117 995424 18.00% Included 0.18 Included
2 18.9.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings.This includes jointing of pipes and fittings with one step CPVC solvent cement , trenching, refilling & testing of joints complete as per direction of Engineer in Charge: 75 mm nominal outer dia Pipes Metre 50.00 120002119 995424 18.00% Included 0.18 Included
3 18.9.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings.This includes jointing of pipes and fittings with one step CPVC solvent cement , trenching, refilling & testing of joints complete as per direction of Engineer in Charge: 100 mm nominal outer dia Pipes Metre 315.00 120002120 995424 18.00% Included 0.18 Included
4 18.31.1.2 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :100 mm diameter: Class II Each 4.00 120002217 995424 18.00% Included 0.18 Included
5 18.14 Fixing water meter and stop cock in pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). Each 1.00 120002140 995424 18.00% Included 0.18 Included
6 18.17.4 Providing and fixing gun metal gate valve with C.I.wheel of approved quality( Screwed ended): 50 mm nominal bore Each 10.00 120002148 995424 18.00% Included 0.18
7 18.17.6 Providing and fixing gun metal gate valve with C.I.wheel of approved quality( Screwed ended): 80 mm nominal bore Each 5.00 120002150 995424 18.00% Included 0.18
8 18.18.2 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore Each 20.00 120002152 995424 18.00% Included 0.18
9 18.32.1 Constructing masonary Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve with C. I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement:3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 15.00 120002228 995424 18.00% Included 0.18
10 18.59.1 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 50 mm dia Each 10.00 120002306 995424 18.00% Included 0.18
11 18.60.1 Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately): 80 mm dia nominal bore Each 1.00 120002309 995424 18.00% Included 0.18
12 18.16.1 Providing and fixing brass stop cock of approved quality: 15 mm nominal bore Each 1.00 120002143 995424 18.00% Included 0.18
13 18.16.2 Providing and fixing brass stop cock of approved quality: 20 mm nominal bore Each 1.00 120002144 995424 18.00% Included 0.18
14 18.41.6 Providing and filling sand of grading zone V or coarser grade all-round the pipes in external work: 50 mm dia nominal bore Metre 175.00 120002259 995424 18.00% Included 0.18
15 18.41.8 Providing and filling sand of grading zone V or coarser grade all-round the pipes in external work: 80 mm diameter pipe Metre 50.00 120002261 995424 18.00% Included 0.18
16 18.41.9 Providing and filling sand of grading zone V or coarser grade all-round the pipes in external work: 100 mm diameter pipe Metre 315.00 120002262 995424 18.00% Included 0.18
17 18.80.2 Disinfecting C.I. water mains by flushing with water containing bleaching powder @ 0.5 gms per litre of water and cleaning the same with fresh water, operation to be repeated three times including getting the sample of water from the disinfected main tested in the municipal laboratory: 100 mm diameter C.I. pipe Metre 540.00 120002408 995424 18.00% Included 0.18
18 23.3.1 Supply, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS:12818, including required hire and labour charges, fittings and accessories etc. all complte, for all depths, as per direction of Engineer-in-charge: 100 mm nominal size dia metre 60.00 120002906 995458 18.00% Included 0.18
19 23.3.2 Supply, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS:12818, including required hire and labour charges, fittings and accessories etc. all complte, for all depths, as per direction of Engineer-in-charge:150 mm nominal size dia metre 2.00 120002907 995458 18.00% Included 0.18
20 23.4.1 Supply, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (RMS) pipes with ribs, conforming to IS:12818, including required hire and labour charges, fittings and accessories etc. all complte, for all depths, as per direction of Engineer-in-charge: 100 mm nominal size dia metre 2.00 120002909 995458 18.00% Included 0.18
21 23.4.2 Supply, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (RMS) pipes with ribs, conforming to IS:12818, including required hire and labour charges, fittings and accessories etc. all complte, for all depths, as per direction of Engineer-in-charge: 150 mm nominal size dia metre 60.00 120002910 995458 18.00% Included 0.18
22 23.13.1 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of borewell housing/casing pipe, removable as per requirement, all complete for borewell of:100 mm dia Each 1.00 120002924 995458 18.00% Included 0.18
23 23.14.1 Providing and fixing M.S clamp of required dia to the top of casing/housing pipe of tubewell as per IS;2800 (part I), including necessary bolts and nuts of required size complete: 100 mm clamp Each 1.00 120002871 995428 18.00% Included 0.18
24 23.15.1 Providing and fixing Bail plug/Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part-I): 100 mm dia Each 1.00 120002930 995458 18.00% Included 0.18
25 23.8 Gravel packing in tubewell construction in accordance with IS:4097, including providing gravel fine/medium,coarse, in required grading and size as per actual requirement, all complete as per direction of Engineer-in-charge. Cum 1.00 120003112 995428 18.00% Included 0.18
Sub-head-II EXTERNAL SEWAGE SYSTEM 0 0
26 2.10.1.2 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil: Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. Meter 2000.00 120000354 995433 18.00% Included 0.18
27 2.11 Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre). Meter 210.00 120000356 995433 18.00% Included 0.18
28 2.12 Extra for excavating trenches for pipes, cables, etc, in all kinds of soil for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is over corresponding basic item for depth upto 1.5 metre.) Meter 25.00 120000357 995433 18.00% Included 0.18
29 19.1.2 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm diameter Metre 450.00 120002625 995424 18.00% Included 0.18
30 19.1.3 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 200 mm diameter Metre 325.00 120002626 995424 18.00% Included 0.18
31 19.6.2 Providing and laying non pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement :2 fine sand) including testing of joints etc. complete : 150 mm dia R.C.C. pipe Metre 870.00 120002653 995424 18.00% Included 0.18
32 19.6.3 Providing and laying non pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement :2 fine sand) including testing of joints etc. complete : 250 mm dia R.C.C. pipe Metre 520.00 120002654 995424 18.00% Included 0.18
33 19.6.4 Providing and laying non pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement :2 fine sand) including testing of joints etc. complete : 300 mm dia R.C.C. pipe Metre 45.00 120002655 995424 18.00% Included 0.18
34 19.2.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 150 mm diameter S.W. pipe Metre 450.00 120002630 995424 18.00% Included 0.18
35 19.2.3 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 200 mm diameter S.W. pipe Metre 325.00 120002631 995424 18.00% Included 0.18
36 19.3.2 Providing and laying cement concrete 1:5:10 (1 cement :5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of S.W/ RCC. pipes including bed concrete as per standard design : 150 mm diameter R.C.C. pipe Metre 90.00 120002634 995424 18.00% Included 0.18
37 19.3.4 Providing and laying cement concrete 1:5:10 (1 cement :5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of S.W/ RCC. pipes including bed concrete as per standard design : 250 mm diameter R.C.C.. pipe Metre 50.00 120002636 995424 18.00% Included 0.18
38 19.3.5 Providing and laying cement concrete 1:5:10 (1 cement :5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of S.W/ RCC. pipes including bed concrete as per standard design : 300 mm diameterR.C.C. pipe Metre 15.00 120002637 995424 18.00% Included 0.18
39 19.4.1.1 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type: With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 40.00 120002638 995424 18.00% Included 0.18
40 19.7.1.1 Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 60.00 120002665 995424 18.00% Included 0.18
41 19.8.1.1 Extra for depth for manholes: Size 90x80 cm: With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 12.00 120002671 995424 18.00% Included 0.18
42 19.16 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring protections on tail lenght on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification & having manufacture's permanent identification mark to be visible even after fixing, including fixing in manhole with 30x20x15 cm cement concrete block 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. Each 150.00 120002689 995424 18.00% Included 0.18
43 19.21.1 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete: distribution branch with G. I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: For pipes 100 to 250 mm diameter Each 1.00 120002703 995424 18.00% Included 0.18
44 19.21.2 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete: distribution branch with G. I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: For pipes 250 to 300 mm diameter Each 1.00 120002704 995424 18.00% Included 0.18
45 19.27.1 Constructing brick masonary road gully chamber 50x45x60 cm with bricks of class designation 75 in cement morter 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast RCC horizontal grating complete as per standard design: With common burnt clay F.P.S(non modular) bricks of class designation 7.5 Each 80.00 120002722 995424 18.00% Included 0.18
46 19.32.1 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W drain pipe 100 mm diameter, 1.8 m long complete as per standard design: With common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5 Each 2.00 120002731 995424 18.00% Included 0.18
47 2.6.1 Earth work in excavation by mechanical means ( Hydraulic excavator)/ manual means over areas ( Exceeding 30 cm in depth , 1.5 m in width as well as 10 sqm on plan ) including getting out diaposal of excavated earth lead upto 50 m and lift upto 1.5 m , as directed by Engineer-in-charge: All kind of soil Cum 39.564 120000345 995433 18.00% Included 0.18
48 2.7.1 Earth work in excavation by mechanical means ( Hydraulic excavator)/ manual means over areas ( Exceeding 30 cm in depth , 1.5 m in width as well as 10 sqm on plan ) including getting out diaposal of excavated earth lead upto 50 m and lift upto 1.5 m , as directed by Engineer-in-charge: Ordinary rock Cum 9.891 120000346 995433 18.00% Included 0.18 Included
49 2.26.1 Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked materials:All kind of soil Cum 33.91 120000392 995433 18.00% Included 0.18 Included
50 2.26.2 Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked materials:Ordinary rock Cum 8.48 120000393 995433 18.00% Included 0.18 Included
51 23.1.1.1 Boring/drrilling borewell of required dia for casing/strainer pipe, by suitable method prescribed in IS:2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, inlcuding hire & running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre & upto 150 metre depth below ground level: All types of soil: 300 mm dia metre 120.00 120003061 995458 18.00% Included 0.18 Included
52 23.3.1 Supply, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS:12818, including required hire and labour charges, fittings and accessories etc. all complte, for all depths, as per direction of Engineer-in-charge: 100 mm nominal size dia metre 4.00 120002906 995458 18.00% Included 0.18 Included
53 23.3.2 Supply, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS:12818, including required hire and labour charges, fittings and accessories etc. all complte, for all depths, as per direction of Engineer-in-charge:150 mm nominal size dia metre 120.00 120003105 995458 18.00% Included 0.18 Included
54 23.4.1 Supply, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (RMS) pipes with ribs, conforming to IS:12818, including required hire and labour charges, fittings and accessories etc. all complte, for all depths, as per direction of Engineer-in-charge: 100 mm nominal size dia metre 4.00 120002909 995458 18.00% Included 0.18 Included
55 23.4.2 Supply, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (RMS) pipes with ribs, conforming to IS:12818, including required hire and labour charges, fittings and accessories etc. all complte, for all depths, as per direction of Engineer-in-charge:150 mm nominal size dia metre 120.00 120003106 995458 18.00% Included 0.18 Included
56 23.13.1 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of borewell housing/casing pipe, removable as per requirement, all complete for borewell of: 100 mm dia Each 2.00 120002924 995458 18.00% Included 0.18 Included
57 23.14.1 Providing and fixing M.S clamp of required dia to the top of casing/housing pipe of tubewell as per IS;2800 (part I), including necessary bolts and nuts of required size complete:100 mm clamp Each 2.00 120002927 995458 18.00% Included 0.18 Included
58 23.15.1 Providing and fixing Bail plug/Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part-I): 100 mm dia Each 2.00 120002930 995458 18.00% Included 0.18 Included
59 23.5 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Cum 7.07 120002912 995458 18.00% Included 0.18 Included
60 23.6 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Cum 7.07 120002913 995458 18.00% Included 0.18 Included
61 23.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. Cum 7.07 120003107 995458 18.00% Included 0.18 Included
62 23.9 Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. each 2.00 120002916 995458 18.00% Included 0.18 Included
Pumps Included 0 Included
1 NS/MR Supplying, installing, testing and commisioning of SS vertical/ horizontal muli stage centrifugal pump suitable for automatic operation consisting of following Included 0 Included
Horizontally mounted centrifugal end suction pump complete with mechanical seal and including necessary arrangement for testing for pump. (The pump shall have cast iron head, base plate SS Shaft/ Impeller/ Intermediate chamber) Included 0 Included
Squirrel cage induction motor suitable foe 415V, 50Hz, AC supply suitable for the above pump with synchronous speed of 2900RPM TEFC type and conforming to IP:55 and felxible coupling and copuling guard with the pump Included 0 Included
Common bed plate for mounting pump and motor fabricated of suitable MS channel or cast iron type as per manufacturer's recommendations Included 0 Included
Suitable reinforced cement concrete pump foundation including Dunlop antivibration(cushy foot) mounting, foundation bolts, washers as required Included 0 Included
The pump shall have following specifications Included 0 Included
(i) Discharge= 900LPM; (ii0 Head= 30m Included 0 Included
Material of construction Included 0 Included
Impeller- Bronze; Casing-CI; Shaft & Shaft sleeve-SS-410; Bearing-Grease Lubricated; Seal & Make- Mechanical; Type of Pump-End suction Set 2 995424 18.00% Included 0.18 Included
Total External Water Supply, Sewerage and pumps & Equipments charges (Excluding GST) 0.00 0
Total GST on Charges 0.00
Total External Water Supply, Sewerage and pumps & EquipmentsCharges including GST 0.00
Place : 00-Jan-00 Printed Name : 0
Designation : 0
N1/C&M/22-23/TBCB/OT/12 dtd. 13.04.2022 Schedule - 6
Civil works for Package – II under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C) As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-2 0.00%
To: As per Percent on Sch-2 #REF!
Bidder’s Name and Address Contracts & Material Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : B-9, Qutab Institutional Area,
Katwaria Sarai, Multipackage Discount #REF!
New Delhi-110016
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. DSR 2016 Item ref./ MR Description Unit Quantity Activity Number SAC Code (Service Accounting Codes) Whether SAC in column ‘5’ is confirmed. If not indicate applicable the SAC # Rate of GST applicable ( in %) Whether rate of GST in column ‘7’ is confirmed. If not indicate applicable rate of GST # (Select suitable GST rate from Dropdown) Unit Charges (excluding Tax) Total Installation Charges (excluding Tax) Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges
Sub-head-I S.H.-I EARTH WORK
1 1.1.2 Carriage of materials by mechanical transport including loading, unloading and stacking Up to 1 Km.: Earth Cum 232 120000008 995428 18.00% Included 0.18 Included
2 1.1.4 Carriage of materials by mechanical transport including loading, unloading and stacking Up to 1 Km.: Excavated rock Cum 2088 120000024 995428 18.00% Included 0.18 Included
3 2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed: All kinds of soil cum 1920 120000345 995433 18.00% Included 0.18 Included
4 2.7.1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed by Engineer-in-Charge:Ordinary Rock cum 192 120000346 995433 18.00% Included 0.18 Included
5 2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. cum 400 120000349 995433 18.00% Included 0.18 Included
6 2.9.1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: Ordinary rock Cum 360 120000350 995433 18.00% Included 0.18 Included
Sub-head-II CONCRETE WORK 0 Included
7 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). Cum 239.255 120000442 995454 18.00% Included 0.18 Included
Sub-head-III REINFORCED CEMENT CONCRETE 0 Included
8 5.22.6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: Thermo-Mechanically Treated bars of grade Fe500D or more Kg 12000 120000543 995454 18.00% Included 0.18 Included
Sub-head-IV BRICK WORK 0 Included
9 6.1.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) cum 27.6 120000600 995456 18.00% Included 0.18 Included
Sub-head-V FINISHING 0 Included
10 13.7.2 12mm Cement plaster finished with a floating coat of neat cement of mix: 1:4 (1 Cement:4 fine sand) Sq.m. 584 120001412 995472 18.00% Included 0.18 Included
Sub-head-VI DEVELOPMENT WORK 0 Included
11 16.1 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. sqm 1800 120001732 995428 18.00% Included 0.18 Included
12 M16.46.1 Providing and laying in position bitumen hot sealing compound for expansion joints etc: Using grade 'A' sealing compound. (Depth=10Cm, Width= 1.5cm) metre 221.25 100004494 995458 18.00% Included 0.18 Included
13 16.79 Providing, laying, spreading and compacting graded stone aggregate (size range 53mm to 0.075mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in all leads & lifts, laying in umiform layers with mechanical paver finishes in sub-base/ base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-In-Charge cum 540 120001854 995428 18.00% Included 0.18 Included
14 16.68 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong viratory compaction of approved size, design & shape , laid in required coulour and pattern over the including 50mm thick compacted bed of course sand,filling the joints with line sand etc. complete as per the direction of Engineer-in-charge. sqm 600 120001838 995421 18.00% Included 0.18 Included
15 16.69 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement :3 coarse sand), including making joints with or without grooves (thicknes of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge. cum 12 120001839 995421 18.00% Included 0.18 Included
16 16.75 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Note: Cement content considered in this item is @ 330kg/cum. Excess/less cement used as per design mix is payable /recoverable separately). cum 120 170002363 995428 18.00% Included 0.18 Included
17 5.35 Add for using extra cement in the items of design mix over and above the specified cement content thereing quintal 84 120000568 995454 18.00% Included 0.18 Included
18 19.6.1 Providing and laying non Pressure NP2 class (Light Duty) RCC Pipe including collar jointed with stiff mixture of cement mortar 1:2 including testing of joints complete : 100 mm dia RCC Pipe metre 18 120002652 995424 18.00% Included 0.18 Included
19 19.6.2 Providing and laying non Pressure NP2 class (Light Duty) RCC Pipe including collar jointed with stiff mixture of cement mortar 1:2 including testing of joints complete : 150 mm dia RCC Pipe metre 18 120002653 995424 18.00% Included 0.18 Included
20 19.35.1 Providing and laying Non Pressure NP-3 class (Medium duty) RCC pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement :2 fine sand) including testing of joints etc. complete 450 mm dia RCC pipes. Metre 15 120002735 995424 18.00% Included 0.18 Included
21 19.35.2 Providing and laying Non Pressure NP-3 class (Medium duty) RCC pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement :2 fine sand) including testing of joints etc. complete 600 mm dia RCC pipes. Metre 9 120002736 995424 18.00% Included 0.18 Included
22 10.25.2 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel, etc as required : In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works Kg 100 120001153 995476 18.00% Included 0.18 Included
Sub-head-VII Market Rate 0 Included
23 MR Providing and laying of Polythene sheet of 125micron over PCC (1:4:8) for road work complete in all respect at all levels Kg 1100 995428 18.00% Included 0.18 Included
Total Road Work charges (Excluding GST) 0.00 0
Total GST on Road Work Charges 0.00
Total Road Work including GST 0.00
Place : 00-Jan-00 Printed Name : 0
Designation : 0
N1/C&M/22-23/TBCB/OT/12 dtd. 13.04.2022 Schedule - 3
Civil works for Package – II under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(SUMMARY OF TAXES & DUTIES)
Bidder’s Name and Address To:
Contracts & Material
Name : Power Grid Corporation of India Ltd.,
Address : SCO-5-10, Beside PCB Building,
Sector 16A, Faridabad, Haryana- 121002
(Adjacent to Metro Hospital)
Sl. No. Description Total Price (INR)
1 Total GST for Supply of Services between the Contractor and the Employer (identified in Schedule 2) which are not included in the Unit price as per the provision of the Bidding Documents, as applicable. 0.00
Date : -- Printed Name : 0
Place : 00-Jan-00 Designation : 0
N1/C&M/22-23/TBCB/OT/12 dtd. 13.04.2022 Schedule - 7A
Civil works for Package – II under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(GRAND SUMMARY)
Contracts & Material
Name : Power Grid Corporation of India Ltd.,
Address : SCO-5-10, Beside PCB Building,
Sector 16A, Faridabad, Haryana- 121002
(Adjacent to Metro Hospital)
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 2 0.00 0
Total Civil + Electrical Portion Charges (excluding GST)
2 TOTAL SCHEDULE NO. 3 0.00 0
External Electrification Price
3 TOTAL SCHEDULE NO.4 0.00 0
Internal Electrification Price
4 TOTAL SCHEDULE NO. 5 0.00 0
External Water Supply, Sewerage and pumps & Equipments Price
5 TOTAL SCHEDULE NO.6 0.00 0
Road Work for Residential complex price
6 TOTAL SCHEDULE NO. 3 0.00
Total GST Amount for Civil + Electrical Portion
7 GRAND TOTAL[1+2] 0.00
Date : -- Printed Name : 0
Place : 00-Jan-00 Designation : 0
This letter of discount is optional. Bidder may / may not offer any discount.
N1/C&M/22-23/TBCB/OT/12 dtd. 13.04.2022 Letter of Discount
LETTER OF DISCOUNT
Contracts & Material
Power Grid Corporation of India Ltd.,
SCO-5-10, Beside PCB Building,
Sector 16A, Faridabad, Haryana- 121002
(Adjacent to Metro Hospital)
Subject : Civil works for Package – II under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
With reference to the subject tender, we hereby offer unconditional discount on the prices quoted by us as per details given here below : Final Discount Factor
1 Discount on lum-sum basis on total price quoted by us . [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1,2,3] In Rs. #REF! #REF!
1 Discount on percent basis on total price quoted by us [The discount shall be proportionately applicable on all the items of all the Schdules ] In Percent (%) #REF! 0.00%
3 Discount on lum-sum basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Rs.
Schedule-1 : Ex works prices In Rs. 0.00 0.00% Schedule-1 : Ex works prices #REF!
Schedule-1 : Ex works prices (Bought Out Only) In Rs. #REF! #REF! Schedule-1 : (Bought Out Only) #REF!
Schedule-2 : Freight & Insurance In Rs. #REF! #REF! Schedule-2 : Freight & Insurance #REF!
Schedule-3 : Installation Charges In Rs. 0.00 0.00% Schedule-3 : AMC Charges #REF!
Schedule-7 : Type Test Charges In Rs. #REF! Schedule-6 : Type Test Charges #REF!
4 Discount on percent basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Percent (%)
Schedule-1 : Ex works prices In Percent (%) 0.00 0.00%
Schedule-1 : Ex works prices (Bought Out Only) In Percent (%) #REF! 0.00%
Schedule-2 : Freight & Insurance In Percent (%) #REF! 0.00%
Schedule-3 : Installation Charges In Percent (%) 0.00 0.00%
Schedule-7 : Type Test Charges In Percent (%) #REF!
3 Multipackage discount on Total Price on LS Basis quoted without T&D (Applicable on this package only if other package covered under the same bidding Document is also awarded to us, Discount) #REF!
4 Multipackage discount on Total Price on percent Basis quoted without T&D (Applicable on this package only if other package covered under the same bidding Document is also awarded to us, Discount) #REF!
Discount(s) offered at sl. No. 1 to 4 will automatically get displayed and accounted for in the respective items of the Schedules.
5 We hereby offer Multi-package discount as given below:
Multi-Package Discount(s) offered at sl. No. 3 & 4 will not get automatically accounted for in the respective items of the Schedules. The same shall be worked out saparately for evaluation.
Please consider this letter of discount as the integral part of our price bid.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : -- Printed Name : 0
Place : 00-Jan-00 Designation : 0
N1/C&M/22-23/TBCB/OT/12 dtd. 13.04.2022 Schedule - 5A After Discount
Civil works for Package – II under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(GRAND SUMMARY : AFTER DISCOUNT)
Bidder’s Name and Address To:
Contracts & Material
Name : Power Grid Corporation of India Ltd.,
Address : SCO-5-10, Beside PCB Building,
Sector 16A, Faridabad, Haryana- 121002
(Adjacent to Metro Hospital)
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 2 0.00 #REF!
Total Civil + Electrical Portion Charges (excluding GST)
2 TOTAL SCHEDULE NO. 3 0.00
External Electrification Price
3 TOTAL SCHEDULE NO.4 0.00
Internal Electrification Price
4 TOTAL SCHEDULE NO. 5 0.00
External Water Supply, Sewerage and pumps & Equipments Price
5 TOTAL SCHEDULE NO. 6 0.00
Road Work for Residential complex price
6 TOTAL SCHEDULE NO. 3 0.00
Total GST Amount for Civil + Electrical Portion
7 GRAND TOTAL [1+2] 0.00
Date : -- Printed Name : 0
Place : 00-Jan-00 Designation : 0
N1/C&M/22-23/TBCB/OT/12 dtd. 13.04.2022 Bid Form 2nd Envelope (Price Bid) Sole Bidder 1 st 1 January
0 2 nd 2 February
BID FORM (Second Envelope) 3 rd 3 March
Bid Proposal Ref. No. 5 th 5 May
Date : -- 6 th #VALUE! 6 June
7 th #VALUE! 7 July
To: 8 th #VALUE! 8 August
Contracts & Material 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 th 10 October
SCO-5-10, Beside PCB Building, 11 th 11 November
Sector 16A, Faridabad, Haryana- 121002 12 th 12 December
(Adjacent to Metro Hospital) 13 th
Name of Contract : Civil works for Package – II under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C) 15 th
Dear Ladies and/or Gentlemen, 16 th
Schedule 2 Civil & Electrical Works
Schedule 3 External Electrification
Schedule 4 Internal Electrification
Schedule 5 External Water Supply, Sewerage and pumps & Equipments
Schedule 6 Road Work for Residential complex
2.5 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced.
3.0 We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us/our Associate (applicable for Foreign Bidder), our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
3.1 100% of applicable Taxes and Duties i.e GST, which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
3.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
4.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
5.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Date : -- Printed Name : 0
Place : 0 Designation : 0
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 : Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Name of Package : Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
Specification No. : N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022
Completion Period 8 Months
: Attachments : General guidelines for filling up the Attachments Construction of Residential Complex: - :
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
Specification No.: N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022
1 Fill up only green shaded cells in the relevent attachments.
2 Attachments 3(JV), 3(QR), Attach QR, 4, 4(A), 4(B), 5, 6, 7, 9, 10, 11, 12, 13, 14, 15, 16, 17,18, 19 and Bid Form for 1st Envelope are included here.
3 Attachment 1 Bid Security : To be submitted as perproforma provided in the bidding document.
4 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
5 Attachment 8 Manufacturer’s Authorisation Form : To be furnished as per proforma provided in the bidding document, on the letter head of the each Manufactures proposed to supply main items. Not included here.
6 Attachment 14 Integrity Pact : To be submitted as per ITB Clause No. 9.3(n) and as per remarks in the Attach 14-IP.
7 Attachment 18 Safety Pact : To be submitted as per ITB Clause No. 9.3(r) and as per remarks in the Attach 18.
8 Attachment 20: Declaration of Key Managerial Person jointly with Power of Attorney holder
9 Attachment 21: Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order, if applicable
10 Attachment 22: Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order, if applicable
11 Attachment 23: Compliance to the process related to the e-RA Terms & Conditions and the Business Rules governing the e-RA
Note : Enable the Active X Control & Macros. Also ensure to keep option of "Trust acess to VBA project object Model" cheched [√]. Ensure that you work on MS Excel 2007 or higher version.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Sole Bidder 1
Yes JV (Joint Venture) 2 or More
Enter following details of the bidder No
Specify type of Bidder [Select from drop down menu] Sole Bidder Sole Bidder 2 0
Address of Bidder
Whether the bidder is an MSE (Micro & Small Enterprise) Yes Yes 2 2 0
Enter the Name of Registration Authority
Whether the bidder meets Minimum Local Content in line with PPP-MII order, 2017 0 2 2 0
e-mail ID of Bid Signatory
Mobile No. of Bid Signatory
Tel No. of Bid Signatory
Fax No. of Bid Signatory MSE Yes
Name of other Partner Ram Lal
Address of other Partner G5
Name of other Partner - 2 (more, if any)
Address of other Partner - 2 (more, if any)
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-3(JV) Sole Bidder
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Joint Venture Agreement and Power of Attorney for Joint Venture*)
Bidder’s Name and Address To:
Contract & Materials & Ram Lal
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
0 Faridabad-121002
This Attachment is Not Applicable
Name(s) and Addresse(s) of other partner(s)
The Joint Venture Agreement (as per the proforma attached at no. 15 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) and Power of Attorney for Joint Venture (as per the proforma attached at no. 14 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) are enclosed herewith Sole Bidder
Date : -- Printed Name : 0
Place : Designation : 8
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-3(QR)
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Qualifying Requirement Data)
Bidder’s Name and Address (Lead Partner of) : To:
Contract & Materials
Name: 0 Power Grid Corporation of India Ltd.,
Address: 0 Northern Region –I, Regional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
Faridabad-121002
In support of the Qualification Requirements (QR) for bidders, stipulated in Annexure-A (BDS) of the Section - III (BDS), Volume-I & Additional Information required as per ITB clause 9.3(c) of the Bidding Documents, we furnish herewith our QR data/details along with other information, as follows herewith our stipulations have been reproduced in italics for ready reference, however, in case of any discrepancy the QR as given in BDS shall prevail).
* We have submitted bid as individual firm.
* We have submitted bid as joint venture of following firms :
(ii) #REF! 2 or more
(* Strike-off whichever is not applicable)
[For details regarding Qualification Requirements of a Joint Venture, please refer para 4.0 below.]
We are furnishing the following details/document in support of Qualifying requirement for the subject package.
A Attached copies of original documents defining :
a) The constitution or legal status;
b) The principal place of business;
c) The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
B Attached original & copies of the following documents :
a) Written power of attorney of the signatory of the Bid to commit the bidder.
b) Joint Venture Agreement.
GENERAL INFORMATION
Bidder is required to provide general information as per the following format.
[Where the Bidder proposes to use named subcontractor(s) for critical components of the works or for work contents in excess of ten (10) percent of the bid price, the following information should also be supplied for the subcontractor(s)].
S No. Particulars Name of the Bidder
1 Name of the Firm 0
2 Head Office/ Registered Office Address
5 Contact Person
6 Place of Incorporation/ Registration
7 Year of Incorporation/ Registration
8 Date of Commercial production
9 Nationality of
10 Whether the bidder is an MSE (Micro & Small Enterprise). If Yes, attach Documentary Evidence with the Bid.
11 Whether the Bidder is a Start-Ups Company (as defined by DIPP). If Yes, attach Documentary evidence with the Bid.
1.0 TECHNICAL REQUIREMENTS {Reference para 1.0 of Annexure-A (BDS)}
1.1 1.0 Technical Experience: The Bidder should have successfully executed similar works (i.e. Building Works, Boundary wall works etc.) for Govt. or Semi Govt. or reputed private Sector organization within the last seven years from the originally scheduled date of bid opening, as per following. - i. One single work/project of a value of not less than INR 362.17 Lakhs including GST OR ii. Two works/projects, each of a value of not less than INR 226.36 Lakhs including GST OR iii. Three works/projects, each of a value of not less than INR 181.08 Lakhs including GST
1.2 Route-2: The bidder(s) who have established production line and testing facilities in India for 715kV or above class Reactor based on Technological Support of the Collaborator(s) for the equipment(s) can also be considered qualified provided, The bidder must have manufactured in India, type tested 715kV or higher voltage class either One (1) no. 1-phase Reactor of at least 80 MVAR capacity or One (1) no. 1-phase Transformer of at least 166 MVA capacity and the same should have been supplied as on the date of bid opening as mentioned above based on Technological Support of Collaborator(s) provided that:- (a) Collaborator(s) meets the Technical Experience criteria stipulated in Route-1. (b) A legally enforceable undertaking jointly by Bidder and the Collaborator(s) (as per enclosed format in Section-VI of bidding document) is furnished along with the bid, to guarantee quality, timely supply, performance and warranty obligations for five(5) years for entire quantity to be manufactured and supplied from the works in India and a confirmation letter from the Collaborator(s) along with the bid stating that Collaborator(s) shall furnish performance guarantee for an amount of 10% of the cost of such equipment(s). This performance guarantee shall be in addition to contract performance guarantee to be submitted by the bidder.
1.3 Route-3: In case, the bidder is an Indian Entity established as Subsidiary/JVC/Group company by its parent/principal, who have established production line and testing facilities in India for 715kV or above class Reactor based on Technological Support of the parent/principal for the equipment(s) can also be considered qualified provided, The bidder must have manufactured in India, type tested 715kV or higher voltage class either One (1) no. 1-phase Reactor of at least 80 MVAR capacity or One (1) no. 1-phase Transformer of at least 166 MVA capacity and the same should have been supplied as on the date of bid opening as mentioned above based on Technological Support of Parent/ Principal company provided that:- (a) Parent/ Principal company meets the Technical Experience criteria stipulated in Route-1. (b) A legally enforceable undertaking jointly by Bidder and the Parent/ Principal company (as per enclosed format in Section-VI of bidding document) is furnished along with the bid, to guarantee quality, timely supply, performance and warranty obligations for five(5) years for entire quantity to be manufactured and supplied from the works in India and a confirmation letter from the Parent/ Principal company along with the bid stating that Parent/ Principal company shall furnish performance guarantee for an amount of 10% of the cost of such equipment(s). This performance guarantee shall be in addition to contract performance guarantee to be submitted by the bidder.
In case bidder is a holding company, the technical experience referred to in para 1.1 above shall be of that holding company only (i.e. excluding its subsidiary/group companies). In case bidder is a subsidiary of a holding company, the technical experience referred to in para 1.1 above shall be of that subsidiary company only (i.e. excluding its holding company).
Using the following formats, each Bidder is requested to list the experience as detailed above, on the basis of which the Bidder wishes to qualify. The information is to be summarised using following format for each experience of the Bidder
(The bidder shall attach documentary evidence, such as copies of utility certificates for completed contracts and copies of award letters etc. for ongoing contracts in support of his experience as listed in the following proforma for each Contract with the help of "Attach" Buttons provided in table given below).
Format-A: (ROUTE-1)
Format for the Bidder/ Collaborator/ Parent/Principal Company of the bidder who must have designed, manufactured, tested & supplied 715kV or Higher Voltage class Reactor in support of meeting the Technical experience requirement of 1.1 of Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Bidder’s Name : 0 0
Single Firm : 0
1 Name of Contract Undertaken 0
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm
4(a)(i) Voltage Level of Reactors supplied under the Contract (Indicate 715kV or above class only)
No. of Reactor(s) under the contract
(Indicate nos. of 1 phase Reactors with rating not less than 110 MVAR OR no. of Reactors in Banks of 3 single phase units of at least 36.7 MVAR each)
MVAR capacity of the above mentioned three phase/single phase units
Name of the substation or switchyard
(a)(ii) No. of years, the above Reactor(s) are in operation as on the date of bid opening.
Type of cooling in the above Reactor
Scope of work involved under the Contract executed by Bidder
(Tick whichever is/are applicable)
of Reactors of Reactors
of Reactors of Reactors
Details of documents uploaded in support of the above stated experience
4(b)(i) Voltage Level of Transformers supplied under the Contract (Indicate 715kV or above class only)
No. of Transformer(s) under the contract
(Indicate nos. of 1 phase Transformer with rating not less than 500 MVA OR no. of Transformer in Banks of 3 single phase units of at least 166 MVA each)
MVA capacity of the above mentioned three phase/single phase units
Name of the substation or switchyard
Type of cooling in the above Transformer
Scope of work involved under the Contract executed by Bidder
(Tick whichever is/are applicable)
of Transformers of Transformers
of Transformers of Transformers
Details of documents uploaded in support of the above stated experience
4(b)(ii) Voltage Level of Reactors supplied under the Contract (Indicate 345kV or above class only)
No. of Reactor(s) under the contract
(Indicate nos. of 3 phase Reactors with rating not less than 50 MVAR OR no. of Reactor(s) in Banks of 3 single phase units of at least 16.7 MVAR each)
MVAR capacity of the above mentioned three phase/single phase units
Name of the substation or switchyard
Type of cooling in the above Reactor
Scope of work involved under the Contract executed by Bidder
(Tick whichever is/are applicable)
of Reactors of Reactors
of Reactors of Reactors
Details of documents uploaded in support of the above stated experience
4(b)(iii) No. of years, the above transformer(s) and reactor(s) indicated at 4(b)(i) & 4(b)(ii) respctively, are in operation as on the date of bid opening.
Details of documents uploaded in support of the above stated experience
Format-B: (ROUTE-2)
Format for Bidder(s) [who have established production line and testing facilities in India for 715kV or above class Reactor based on Technology Support of Collaborator(s)], in support of meeting the requirement of 1.2 (Route-2), Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents
Name of the Reactor Manufacturer 0 0
1 Name of Contract Undertaken 0
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm
4 Voltage Level of Reactors manufactured under the Contract (Indicate 715kV or above class only)
No. of Reactor(s) under the contract
(Indicate nos. of 1 phase Reactors with rating not less than 80 MVAR)
MVAR capacity of the above mentioned three phase/single phase units
Name of the substation or switchyard
whether the above Reactors are in operation as on the date of bid opening.(Yes/No)
No. of years, the above Reactors are in operation as on the date of bid opening.
Scope of work involved under the Contract
(Tick whichever is/are applicable)
Voltage Level of Transformer supplied under the Contract
No. of Transformer(s) under the contract
(Indicate nos. of 1 phase Transformer with rating not less than 166 MVA)
MVA capacity of the above mentioned three phase/single phase units
Name of the substation or switchyard
Whether the above Transformer are in operation as on the date of bid opening.
No. of years, the above Transformer are in operation as on the date of bid opening.
Scope of work involved under the Contract
(Tick whichever is/are applicable)
Details of documents uploaded in support of the above stated experience
Format-C: (ROUTE-3)
Format for Bidder (Indian entity) established as Subsidiary/ JVC/ Group Company by its Parent/ Principal, who have established production line and testing facilities in India for 715kV or above class Reactor, in support of meeting the requirement of 1.3 (Route-3), Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Bidder 0
Name of the Parent Company/Collaborator/Subsidiary for the 765kV Reactor {The qualifying data for the parent company or collaborator for the equipment is furnished in Format-A above) 0
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the Bidder
4 Voltage Level of Reactor supplied under the Contract (Indicate 715kV or above class only)
No. of Reactor(s) under the contract
(Indicate nos. of 1 phase Reactor with rating not less than 80 MVAR)
MVAR capacity of the above mentioned three phase/single phase units
Name of the substation or switchyard
Date as on which the above mentioned Reactors are supplied based on technological support of parent company / collaborator(s) / subsidiary.
Type of cooling in the above Reactor
Scope of work involved under the Contract executed by bidder
(Tick whichever is/are applicable)
Voltage Level of Transformer supplied under the Contract
No. of Transformer(s) under the contract
(Indicate nos. of 1 phase Transformer with rating not less than 166 MVA)
Name of the substation or switchyard
(b)(ii) Whether the above Transformer are in operation as on the date of bid opening.
No. of years, the above Transformer are in operation as on the date of bid opening.
Scope of work involved under the Contract
(Tick whichever is/are applicable)
5 Whether Parent/Principal company(s) meets the technical experience criteria stipulated at 2.1.1 above, and the details of which is mentioned at Format-A above. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-3 of Annexure-A(BDS))
6 Whether legally enforceable undertaking jointly by Bidder and the Parent/Pricipal company(s) (as per enclosed format in Section-VI: Sample Forms and Procedures of bidding document) is furnished along with the bid. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-3 of Annexure-A(BDS))
7 Confirmation letter from the Parent/Principal Company along with the bid stating that Parent/Principal Company shall furnish performance guarantee, in addition to contract performance guarantee to be submitted by the bidder, for an amount of 10% of the cost of equipment(s) to be manufactured and supplied from the works in India. (Applicable for the Bidder wish/proposes to qualify through Route-3 of Annexure-A(BDS))
8 Details of documents uploaded in support of the above stated experience Annex-XXX Annex-YYY Annex-ZZZ
2.0 FINANCIAL REQUIREMENTS :
Financial Position {Reference para 1.2 of Annexure-A (BDS)} For the purpose of this particular bid, bidders shall meet the following minimum criteria:
a. Minimum Average Annual Turnover @ (MAAT) for best 3 financial years out of last 5 financial years of the bidder shall not be less than INR 679.07 Lakhs @ Annual gross revenue from operation/gross operating income as incorporated in the Profit & Loss account, excluding other income / non-recurring income, i.e. sale of fixed assets. Note: For MSME registered firm, relaxation of 20% on financial aspects i.e MAAT requirement will be considered
b Minimum Average Annual Turnover^ (MAAT) for best three (3) years i.e. 36 months out of last five (5) financial years of the bidder should be Rs. 1233.18 million or equivalent for Reactor Package RT-08 ^ Annual gross revenue from operations/gross operating income as incorporated in the profit & loss account excluding other income.
c Bidder shall have liquid assets (L.A.) or/and evidence of access to or availability of credit facilities of not less than Rs. 205.53 million or equivalent for Reactor Package RT-08
Note: (i) In case bidder is a holding company, the Financial Position criteria referred to in para 2.0 above shall be that of holding company only (i.e. excluding its subsidiary / group companies). In case bidder is a subsidiary of a holding company, the Financial Position criteria referred to in para 2.0 above shall be that of subsidiary company only (i.e. excluding its holding company). (ii) In case bidder has established manufacturing facility in India and yet to complete three (3) financial years, the Net Worth and average of the turnover as per financial statement for completed financial years shall be considered for the purpose of compliance to the specified Net Worth and MAAT requirements. (iii) In case of bidder qualifying through Route-3 but not meeting the Financial Position requirement as per note (i) read along with note (ii) above, the following shall be applicable: In case bidder is yet to complete five (5) years from the date of commercial production of such equipment(s) but no later than seven (7) years from the date of incorporation of the said company as on the originally scheduled date of bid opening as above, the financial position requirement as per para 2.0 (b) & (c) of parent/principal company providing collaboration for technological support shall be considered. However, once he meets the turnover requirement on their own or completes five (5) years from the date of commercial production of such equipment(s) in India but no later than seven (7) years from the date of incorporation as on the originally scheduled date of bid opening as above, the financial position requirements as specified at 2.0 (b) and (c) above shall also be required to be met by such bidder on their own as per note (i) above and not based on their parent/principal company. Further, in case the bidder is yet to complete one (1) financial year, the Net worth requirement as per para 2.0 (a) above of parent/principal shall be considered.
(iv) Relaxation for Start-Ups^/ MSEs Start-Ups^/MSEs, meeting the specified requirements at Para 2 (a) above in Financial Position shall also be considered qualified if they meet Eighty (80) % of the requirement specified at Para 2 (b) & 2 (c) above in Financial Position. ^ Start-Ups as defined by DIPP, applicable as on the originally scheduled date of bid opening.
Note: For MSME registered firm, relaxation of 20% on financial aspects i.e MAAT requirement will be considered
{In support of its ‘Financial Position’, in line with the above, the Bidder (in case of bidding by single firm ) or Company/Constituents must provide the relevant information in support of the same, along with documentary evidence, in the following format}
4.0 Financial Qualification Data for Bidder: 2 or more
Name of the Bidder
Whether the complete Annual Reports together with Audited Financial Statement of accounts/equivalent documents of the company for the FY of immediately preceding the date of submission of bid are available?
Financial year Networth (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
A Turnover details:
Sl No Financial year Turnover (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
5.0 Financial Qualification Data for Parent/Principal Company/Collabrator (If Applicable): 0
Name of Parent/Principal Company/Collabrator
Whether the complete Annual Reports together with Audited Financial Statement of accounts/equivalent documents of the company for the FY of immediately preceding the date of submission of bid are available?
Financial year Networth (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
B Turnover details:
Sl No Financial year Turnover (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
6 The Bidder shall also furnish following documents/details with its bid. {Reference ITB clause 9.3 (c)}
6.1 The complete annual reports together with Audited statement of accounts of the company for last five years of its own (separate) immediately preceding the date of submission of bid.
Note I. In the event the bidder is not able to furnish the information of its own (i.e separate), being a subsidiary company and its accounts are being consolidated with its group/holding/parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/Holding/Parent Company) duly certified by any one of the authority [ (i) Statutory Auditor of the bidder /(ii) Company Secretary of the bidder or (iii) A certified Public Accountant] certifying that such information/documents are based on the audited accounts as the case may be.
II. Similarly, if the bidder happens to be a Group/Holding/Parent Company, the bidder should submit the above documents/information of its own (i.e. exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information/documents are based on the audited accounts, as the case may be.
6.2 Technical Credentials: List of work regarding past experience indicating the execution of similar work successfully, schedule time of completion and actual time of completion, the present status of projects in hand along with presently envisaged completion dates, qualification and experience of key personnel proposed for carrying out the subject work. List of available T & P and Manpower available with the bidder is also to be enclosed. Litigation History: The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder may result in rejection of Bid.
6.3 The Bidder should accordingly also provide the following information/documents
Audited balance sheet and income statements for the last five years as per the following:
A Years preceding to the bid opening Audited Balance Sheet and Income Statements enclosed
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-3(QR)
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Qualifying Requirement Data)
Bidder’s Name and Address (Lead Partner of) : To:
Contract Services
Address: 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
In support of the Qualification Requirements (QR) for bidders, stipulated in Annexure-A (BDS) of the Section - III (BDS), Volume-I & Additional Information required as per ITB clause 9.3(c) of the Bidding Documents, we furnish herewith our QR data/details along with other information, as follows herewith our stipulations have been reproduced in italics for ready reference, however, in case of any discrepancy the QR as given in BDS shall prevail).
* We have submitted bid as individual firm.
* We have submitted bid as joint venture of following firms :
(ii) 0 2 or more
(* Strike-off whichever is not applicable)
[For details regarding Qualification Requirements of a Joint Venture, please refer para 4.0 below.]
We are furnishing the following details/document in support of Qualifying requirement for the subject package.
A Attached copies of original documents defining :
a) The constitution or legal status;
b) The principal place of business;
c) The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
B Attached original & copies of the following documents :
a) Written power of attorney of the signatory of the Bid to commit the bidder.
b) Joint Venture Agreement.
1.0 GENERAL INFORMATION
Bidder is required to provide general information as per the following format.
[Where the Bidder proposes to use named subcontractor(s) for critical components of the works or for work contents in excess of ten (10) percent of the bid price, the following information should also be supplied for the subcontractor(s)].
S No. Particulars Name of the Bidder
1 Name of the Firm
2 Head Office/ Registered Office Address
5 Contact Person
6 Place of Incorporation/ Registration
7 Year of Incorporation/ Registration
8 Nationality of
9 Whether the bidder is an MSE (Micro & Small Enterprise). If Yes, attach Documentary Evidence with the Bid.
10 Whether the Bidder is a Start-Ups Company (as defined by DIPP). If Yes, attach Documentary evidence with the Bid.
2.0 TECHNICAL REQUIREMENTS {Reference para 1.0 of Annexure-A (BDS)}
2.1 TECHNICAL EXPERIENCE
2.1.1 The bidder must have designed, manufactured, tested, supplied, installed and commissioned 345kV or above class 3-phase transformers of at least 200 MVA or at least three (3) nos. 1-phase Transformers each having capacity of at least 66.7 MVA and the same Transformer(s) must have been in satisfactory operation* for atleast two (2) years on the originally scheduled date of bid opening i.e. 19.02.2019.
*Satisfactory operation means certificate issued by the Employer certifying the operation without any adverse remark.
2.1.2 The 345 kV or above class transformer manufacturer(s) who have established production line in India for these equipment(s) based on technological support of a parent company or collaborator for the respective equipment(s) can also be considered provided i) such manufacturer has designed, manufactured, tested, supplied, installed and commissioned 220KV or above class transformers. ii) the parent company (Principals) or collaborator meets qualifying requirements stipulated at para 2.1.1 above; and iii) The 345 kV or above class transformer manufacturer(s) furnishes a) a legally enforceable undertaking (jointly with the parent company or collaborator) to guarantee quality, timely supply, performance and warranty obligations as specified for the equipment(s); and b) a confirmation letter from the parent company or collaborator alongwith the bid stating that parent company or collaborator shall furnish performance guarantee for an amount of 10 % of the cost of such equipment (s). This performance guarantee shall be in addition to Contract Performance Guarantee to be submitted by the Bidder. Note-1: In case bidder is a holding company, the technical experience referred to in clause 2.1.1 and 2.1.2 above as the case may be shall be of that holding company only (i.e. excluding its subsidiary/group companies). In case bidder is a subsidiary of a holding company, the technical experience referred to in clause 2.1.1 and 2.1.2 above as the case may be shall be of that subsidiary company only (i.e. excluding its holding company).
2.1.3 Using the following format, each Bidder (individual firms or partners of a joint venture) is requested to list the experience as detailed above, on the basis of which the Bidder wishes to qualify. The information is to be summarised using following format for each experience of the Bidder
(The bidder shall attach documentary evidence, such as copies of utility certificates for completed contracts and copies of award letters etc. for ongoing contracts in support of his experience as listed in the following proforma for each Contract with the help of "Attach" Buttons provided in table given below).
Format for the Bidder OR Parent Company / Collaborator(s)/ Subsidiary (meeting para 1.1.1, Annexure-A to BDS) in support of meeting the requirement of para 1.1.1, Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Bidder’s Name : 0 0
1 Name of Contract Undertaken (for 345kV or above class Transformers) 0
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm
4 Voltage Level of Transformer erected under the Contract (Indicate 345kV or above class only)
5 No. of Transformer (s) under the contract (Indicate nos. of 345kV or above voltage class Transformer not less than 200MVA or equivalent capacity in banks of 3 single phase units each having capacity of at least 66.7 MVA, during the last Two (2) years)
6 MVA capacity of above mentioned 3-phase/1-phase units
7 Name of the substation or switchyard
8 No. of years, the above Transformer are in operation as on the date of bid opening. (Originally Scheduled)
9 Scope of work involved under the Contract
(Tick whichever is/are applicable)
of Transformer of Transformer of Transformer
10 Details of documents uploaded in support of the above stated experience
Format for the Bidder in support of meeting the requirement of para 1.1.2, Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
a Name of the Bidder
b Whether Bidder/Manufaturer established production line in India for 345kV or above class transformer
c Name of the Parent Company/Collaborator for the 345kV Transformer {The qualifying data for the parent company or collaborator for the equipment is furnished in Format-A above)
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the Bidder
4 Indicate details below in case Contract executed for Transformer
(i) Voltage Level of Transformer erected under the Contract (Indicate 220kV or above class only)
(ii) No. of Transformer (s) under the contract (Indicate nos. of 220kV or above voltage class Transformer only)
(iii) Name of the substation or switchyard
(iv) No. of years, the above Transformer are in operation as on the date of bid opening.
(v) Scope of work involved under the Contract
(Tick whichever is/are applicable)
of Transformer of Transformer of Transformer
5 Whether parent company / collaborator(s) meets the technical experience criteria stipulated at 2.1.1 , and the details of which is mentioned at Format-A above. (Choose whichever is applicable from the drop down menu) Yes
6 Whether legally enforceable undertaking jointly by Bidder and the parent company / collaborator(s) (as per enclosed format in Section-VI: Sample forms and Procedures of the bidding documents) is furnished along with the bid. (Choose whichever is applicable from the drop down menu)
7 Confirmation letter from the Parent Company / Collaborator along with the bid stating that Parent Company / Collaborator shall furnish performance guarantee, in addition to contract performance guarantee to be submitted by the bidder, for an amount of 10% of the cost of equipment(s). (Choose whichever is applicable from the drop down menu)
8 Details of documents uploaded in support of the above stated experience
3.0 FINANCIAL REQUIREMENTS :
Financial Position {Reference para 1.2 of Annexure-A (BDS)} For the purpose of this particular bid, bidders shall meet the following minimum criteria:
a) Net Worth for last 3 financial years should be positive b) Minimum Average Annual Turnover* (MAAT) for best three years i.e. 36 months out of last five financial years of the bidder should be INR 1075.90 million. * Note- “Annual gross revenue from operations/gross operating income as incorporated in the profit & loss account excluding other income”. c) Bidder shall have Liquid Assets (LA) and/or evidence of access to or availability of credit facilities of not less than INR 179.32 million. Note 1:- In case bidder is a holding company, the Financial Position criteria referred to in clause 3.0 above shall be that of holding company only (i.e. excluding its subsidiary / group companies). In case bidder is a subsidiary of a holding company, the Financial Position criteria referred to in clause 3.0 above shall be that of subsidiary company only (i.e. excluding its holding company).
Note 2:- Relaxation for Start-Ups^/ MSEs Start-Ups^/MSEs, meeting the specified requirements at Para 3.0 (a) above in Financial Position shall also be considered qualified if they meet Eighty (80) % of the requirement specified at Para 3.0 (b) & 3.0 (c) above in Financial Position. ^ Start-Ups as defined by DIPP, applicable as on the originally scheduled date of bid opening.
{In support of its ‘Financial Position’, in line with the above, the Bidder (in case of bidding by single firm ) or Company/Constituents must provide the relevant information in support of the same, along with documentary evidence, in the following format}
4.0 Financial Qualification Data: 2 or more
Name of the Bidder 0
Details of documentary evidence submitted in support of Qualification Data
Networth (in Rs. Millions)
Sl No Financial year
For the FY of immediately preceding the date of submission of bid.
B Turnover details:
Details of documentary evidence submitted in support of Qualification Data
Turnover (in Rs. Millions)
Sl No Financial year
For the FY of immediately preceding the date of submission of bid.
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Name of Other Partner-1 of JV 0
Equivalent US$ (in Million) exchange rate* Details of documentary evidence submitted in support of Qualification Data
Networth (in Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
*(Indicate the rate(s) of exchnage against US Dollar at the end of each year, which have been used for arriving the amount at equivalent US Dollar.)
B Turnover details:
Equivalent US$ (in Million) exchange rate* Details of documentary evidence submitted in support of Qualification Data
Turnover (in Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
*(Indicate the rate(s) of exchnage against US Dollar at the end of each year, which have been used for arriving the amount at equivalent US Dollar.)
C Liquid Assets
LA Equivalent US$ (in Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Name of Other Partner-2 of JV 0
Equivalent US$ (in Million) exchange rate* Details of documentary evidence submitted in support of Qualification Data
Networth (in Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
*(Indicate the rate(s) of exchnage against US Dollar at the end of each year, which have been used for arriving the amount at equivalent US Dollar.)
B Turnover details:
Equivalent US$ (in Million) exchange rate* Details of documentary evidence submitted in support of Qualification Data
Turnover (in Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Average Annual Turnover for best Three Years is
*(Indicate the rate(s) of exchnage against US Dollar at the end of each year, which have been used for arriving the amount at equivalent US Dollar.)
C Liquid Assets
LA Equivalent US$ (in Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
4.0 Joint Venture (JV) Firms {Reference para 3.0 of Annexure-A (BDS)}
In case a bid is submitted by a Joint Venture (JV) of two or more firms as partners, all the partners of Joint Venture shall meet collectively requirements stipulated at clauses 3.0 (b) & 3.0 (c) above. The figure of average annual turnover and liquid assets/credit facilities for each of the partners of the JV shall be added together to determine the JV’s compliance with the minimum qualifying criteria set out in Para 3.0 (b) & (c) above.
However, for a JV to be qualified, the partner(s) of JV must also meet the following minimum criteria: i. All the partners of the JV shall meet individually the Financial Position criteria given at 3.0 (a) above. ii. The Lead Partner shall meet, not less than 40% of the minimum criteria given at clause 3.0 (b) & (c) and 100 % of the criteria given above at clause 2.1 iii. The other partner(s) shall meet not less than 25% of the criteria given at clause 3.0 (b) & (c) above and 100 % of the criteria given above at clause 2.1 or 2.2 Failure to comply with this requirement will result in rejection of the joint venture’s bid.
In case of Joint venture, the following conditions shall also apply:
(a) the bid, and in case of successful bid, the specified Form of Agreement shall be signed so as to be legally binding on all partners (as per enclosed format in Section-VI, Vol.-I of bidding document).
(b) one of the partners shall be nominated as Lead Partner, and the Lead Partner shall be authorized to incur liabilities and receive instructions for and on behalf of any and all partners of the Joint Venture, and the entire execution of the Contract shall be done with the Lead Partner and payment under the contract shall be received by the Lead Partner on behalf of the Joint Venture as per power conferred to him in the Power of Attorney. The authorization shall be evidenced by submitting a Power of Attorney signed by legally authorized signatory of all the partners as per Performa in in Section-VI, Vol.-I of bidding documents. The payment under the Contract can also be received by other partner(s) based on authorization of Lead Partner.
(c) All partners of the joint venture shall be liable jointly and severally for the execution of the Contract in accordance with the Contract terms and a statement to this effect shall be included in the authorisation mentioned under (b) above as well as in the Bid Form and in the Contract Form (in case of a successful bid);
(d) Agreement entered into by the Joint Venture partners shall be submitted with the bid.
The bidder shall furnish documentary evidence in support of the qualifying requirement stipulated as above.
4.1 In accordance with the above, in case of JV bidders, it should be ensured that necessary details including those pertaining to each JV partner are furnished and the documents are submitted alongwith the bid. Further, the JV bidders should also ensure that other requirements are complied with. The lists of documents furnished are to be indicated below :
A For Name of the Bidder
B For Name of Other Partner-1 of JV
C For Name of Other Partner-2 of JV
5.0 The Bidder shall also furnish following documents/details with its bid. {Reference ITB clause 9.3 (c)}
5.1 The complete annual reports together with Audited statement of accounts of the company for last five years of its own (separate) immediately preceding the date of submission of bid.
Note I. In the event the bidder is not able to furnish the information of its own (i.e separate), being a subsidiary company and its accounts are being consolidated with its group/holding/parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/Holding/Parent Company) duly certified by any one of the authority [ (i) Statutory Auditor of the bidder /(ii) Company Secretary of the bidder or (iii) A certified Public Accountant] certifying that such information/documents are based on the audited accounts as the case may be.
II. Similarly, if the bidder happens to be a Group/Holding/Parent Company, the bidder should submit the above documents/information of its own (i.e. exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information/documents are based on the audited accounts, as the case may be.
5.2 The Bidder should accordingly also provide the following information/documents
Audited balance sheet and income statements for the last five years as per the following:
A Years preceding to the bid opening Audited Balance Sheet and Income Statements enclosed
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-3(QR)
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Qualifying Requirement Data)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
For our Qualifying Requirements Data, please refer Schedule-QR of this volume.
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-4
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Form of Certificate of Origin and Eligibility)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
We hereby certify that equipment and materials to be supplied are produced in [Name of Countries], eligible source country. Equipments & Materials produced in [Name of countries] Company incorporated & registered in [Name of countries]
We hereby certify that our company is incorporated and registered in [Name of Countries], eligible source country. [Name of Countries] [Name of Countries] [Name of Countries], [Name of Countries],
Date : -- Printed Name :
Place : Designation :
country. country. [Name of Countries], [Name of Countries],
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-4(A)
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
0 Faridabad-121002
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles are included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
S.No. For Equipment Item Description Unit Quantity
Notwithstanding what is stated above, we further confirm that any additional special maintenance tools and tackles, required for the equipment under this package shall be furnished by us at no extra cost to the employer.
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-4(B)
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles which are to be taken back after the completion of the work by us are not included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-5
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Bought-out & Sub-contracted Items)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
We hereby furnish the details of the items/ sub-assemblies, we propose to buy for the purpose of furnishing and installation of the subject Package:
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
We hereby declare that, we would not subcontract the erection portion of the contract without the prior approval of Employer.
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Annexure I to Attachment-5
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Annexure I to Attachment-5
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Details of the proposed sub-contractor/sub-vendor Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-5A
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises)
Bidder's Name and Address: To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 B9, Qutab Institutional Area, Katwaria Sarai
0 New Delhi-110016
1 We hereby furnish the details of the items, components, raw material, services which we propose to buy/avail from Micro and Small Enterprises (MSEs) for the purpose of completion of works under the subject package:
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name Category (Micro or Small)
2 2. The above is a list of items we propose to procure from MSEs. However, based on the situations during the execution of the contract, the above list may undergo changes. We hereby confirm that the details regarding actual procurement from MSEs carried out by us, as per the format provided at Section VI, Forms and Procedures, Volume-I of bidding documents, shall be submitted along with the bills for payment against supplies made/works done during execution of contract.
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-5A
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name Category (Micro or Small)
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-6
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Alternative, Deviations and Exceptions to the Provisions)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
The bidder shall itemize any deviation from the Specifications included in his bid. Each item shall be listed (separate sheets may be used and enclosed with this Attachment) with the following information:
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
The above deviations and variations are exhaustive. We confirm that we shall withdraw the deviations proposed by us at the cost of withdrawal indicated in this attachment, failing which our bid may be rejected and Bid Security forfeited.
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Annexure I toAttachment-6
(Alternative, Deviations and Exceptions to the Provisions)
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-7
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Details of Alternative Bid)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
No Alternative Bid
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-9
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Work Completion Schedule)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 B9, Qutab Institutional Area, Katwaria Sarai
0 New Delhi-110016
We hereby declare that the following Work Completion Schedule shall be followed by us in furnishing and completion of works i.e., Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C) for the period commencing from the effective date of Contract to us :
Sl. No. Description of Work- Activity “Civil works for Package – I under Regional package to be carried out at upcoming Ramgarh-II PS substation (under TBCB route) under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-A.”
Breakup of Completion Schedule in Months (Bidder must fill break-up Schedule)
1 Handing over of site to agency/ Mobilization at site
a Establishment of site office
b Kick off meeting
2 Completing statuory requirement of contract such as labour license, Insurance policies- Workmen Compensation Insurance Policy, Contractor All Risk Insurance Policy, etc
3 Sampling and source approval of construction materials including design mix for RCC concrete or as per BPS
4 Excavation of basement
5 RCC structure work below Plinth level
6 RCC structure work above Plinth level
7 All ancillary Civil works including Brick Work, Plaster, Painting, Doors, Windows, Flooring, Water Proofing, Building. Septic tank/ Soak pit, etc
8 Internal & External electrification
10 Fire Fighting work
11 Plumbing & Sewerage work
12 Road, drain, water harvesting, swimming pool work, etc
13 Development of Horticulture work
14 Balance- Internal, external finishing as per requirement of site
15 Handing/ taking over of facilities including submission of "As BUILT DRAWING" and relevant NOCs (if required)
Date : -- Printed Name :
Place : Designation :
Note : Bidders to enclose a detailed network covering all the activities to be undertaken for completion of the project indicating key dates for various milestones for each phase constituent-wise.
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-10
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Guarantee Declaration)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
Dear Sir, We declare that the ratings, performance figures and availability of the system furnished by us for subject Package covered under this specification are guaranteed by us. We further declare that in the event of any deficiencies in meeting the guarantees in respect of the characteristics mentioned below as established after conducting the factory test, you may at your discretion, reject or accept the equipment after assessing the liquidated damages as specified in the relevant clauses of Bid document. We note that in case we take any deviation regarding the maximum losses, as mentioned above, anywhere in the bid including Attachment-6 (Alternative, Deviations and Exceptions to Provisions), our bid shall be considered non –responsive in line with ITB clause 24.1(b) as modified in Section BDS.
Date -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-11
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Information regarding Ex-employees of POWERGRID in our Organisation)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
We declare that we are aware of and have gone through the “Code of Business Conduct and Ethics for Senior Management Personnel”1 and “Code of Business Conduct and Ethics for Board Members”1 of POWERGRID (hereinafter referred to as the “Code of Conduct”). We further understand that as per the “Code of Conduct”, Senior Management Personnel including Board Members, who have retired/resigned from POWERGRID, shall not accept any appointment or post, as detailed in the referred “Code of Conduct”, within 1 year from the date of cessation of service/directorship unless approved by the Competent Authority. Accordingly, we hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation*
*In case the date of joining in the bidder’s organization of such ex-employee is within 1 year from the date of retirement/resignation from POWERGRID, No Objection Certificate/ approval from the Competent Authority must be furnished along with the bid or subsequent through clarification pursuant to ITB Clause 21.
In case of non-submission of No Objection Certificate/approval of the Competent Authority, as required, We understand that POWERGRID shall deal with such cases as per its Policy and procedures in vogue, which may also result in rejection of our bid. We also confirm that POWERGRID shall be the sole judge in this regard. We further declare that any misrepresentation or submission of false/forged documents/information in this regard shall be dealt with as per the provisions of the Integrity Pact and/or the Bidding Documents and/or POWERGRID’s policy and procedures.
Date : -- Printed Name :
Place : Designation :
Note: 1. “Code of Business Conduct and Ethics for Senior Management Personnel” and “Code of Business Conduct and Ethics for Board Members” are available on POWERGRID’s website https://www.powergridindia.com. 2. The information in similar format should be furnished for each partner of joint venture in case of joint venture bid. 3. In case bidder has furnished no details on ex-employees of POWERGRID or has left blank or has indicated ‘-‘ against the same, it shall be deemed that they have not employed any such person in their organization.
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-11
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract & Materials
Name : Ram Lal Power Grid Corporation of India Ltd.,
Address : G5 Northern Region-I, Reagional Headquarter
Gurgaon SCO Bay No. 5 to 10, Sector- 16 A
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-11
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract & Materials
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region-I, Reagional Headquarter
SCO Bay No. 5 to 10, Sector- 16 A
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 ATTACHMENT-12
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Price Adjustment Data)
Bidder’s Name and Address (Sole Bidder) : To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
0 Faridabad-121002
We hereby furnish the relevant details pertaining to the price adjustment provisions for your specifications and documents . The necessary documentary evidence is enclosed.
Sl. No. Name of Materials/Labour Value of co-efficient Name of the published index Value of index as 30 days prior to date set for opening of bids
In accordance with Clause 2, Appendix-2, Form of Contract Agreement, Section-VI; Forms. Volume-I
PV Price Component
I. Supply and Placement of Reinforcement Steel:
i) A- WPI-HSD 0.10 Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) B-WPI-Baic Metals 0.65 Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
iii) LabourL= 0.05 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
i) A- WPI-HSD 0.20 Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) B-WPI-Cement,Lime and Plaster 0.3 Wholesale Price Index Number for `Manufacture of cement, lime and plaster’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in
C-WPI-Cutting ,Shaping and finishing Stone 0.2 Wholesale Price Index Number for `Cutting, shaping and finishing of stone’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
iii) LabourL= 0.1 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The Bidders are required to estimate and indicate the values of different coefficients for each of the items in the price variation formulae within the specified range such that their summation is as specified in the Bidding Documents. Where no value or ‘-’ or ‘shall be furnished later’ is specified against the coefficient, the same will be deemed to be zero and the fixed component would be suitably adjusted. If the values of all coefficients in price variation formulae indicated by the Bidder are within the specified range but their sum exceeds the summation specified in the Bidding Documents, the values of the coefficients shall be pro-rata adjusted such that the summation remains as per the provisions of the Bidding Documents. If the values of all coefficients indicated by the Bidder are within the specified range but their summation is less than the value specified in the Bidding Documents, the values of the coefficients as indicated by the Bidder shall be considered as such and the fixed component in the price variation formulae would be suitably adjusted. Further, if any of values of the coefficients indicated by the Bidder is out of the range specified in the Bidding Documents, the lower of the values, as indicated by the Bidder vis-à-vis lower value of the range for that coefficient specified in the Bidding Documents, shall be considered and the fixed component would be suitably adjusted.
Prices are firm & Fixed
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-13
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Declaration regarding Social Accountability)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-14
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
Integrity Pact is annexed herewith this Volume.
Date : -- Printed Name :
Place : Designation :
Instruction for printing & submitting Integrity Pact
1. The requisite format of Integrity Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (o).
Power Grid Corporation of India Limited
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai,New Delhi – 110016 hereinafter referred to as
having its Registered Office at
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 1 of 8
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C) Package and Specification Number N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 POWERGRID values full compliance with all relevant laws and regulations, and the principles of economical use of resources, and of fairness and transparency in its relations with its Bidders/ Contractors.
In order to achieve these goals, POWERGRID and the above named Bidder/Contractor enter into this agreement called 'Integrity Pact' which will form a part of the bid.
It is hereby agreed by and between the parties as unde r:
Section I - Commitments of POWERGRID
(1) POWERGRID commits itself to take all measures necessary to prevent corruption and to observe the following principles :
a) No employee of POWERGRID, personally or through family members, will in connection with the tender, or the execution of the contract, demand, take a promise for or accept, for him/herself or third person, any material or other benefit which he/she is not legally entitled to.
b) POWERGRID will, during the tender process treat all Bidder(s) with equity and fairness. POWERGRID will in particular, before and during the tender process, provide to all Bidder(s) the same information and will not provide to any Bidder(s) confidential/ additional information through which the Bidder(s) could obtain an advantage in relation to the tender process or the contract execution.
c) POWERGRID will exclude from evaluation of Bids its such employee(s) who has any personnel interest in the Companies/Agencies participating in the Bidding/Tendering process.
(2) If Chairman and Managing Director obtains information on the conduct of any employee of POWERGRID which is a criminal offence under the relevant Anti-Corruption Laws of India, or if there be a substantive suspicion in this regard, he will inform its Chief Vigilance Officer and in addition can initiate disciplinary actions under its Rules.
Section II - Commitments of the Bidder/Contractor
(1) The Bidder/Contractor commits himself to take all measures necessary to prevent corruption. He commits himself to observe the following principles during his participation in the tender process and during the contract execution :
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 2 of 8
a) The Bidder/Contractor will not, directly or through any other person or firm, offer, promise or give to POWERGRID, or to any of POWERGRID's employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which he/she is not legally entitled to, in order to obtain in exchange an advantage during the tender process or the execution of the contract.
b) The Bidder/Contractor will not enter into any illegal agreement or understanding, whether formal or informal with other Bidders/Contractors. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or actions to restrict competitiveness or to introduce cartelization in the bidding process.
c) The Bidder/Contractor will not commit any criminal offence under the relevant Anti-corruption Laws of India; further, the Bidder/Contractor will not use for illegitimate purposes or for purposes of restrictive competition or personal gain, or pass on to others, any information provided by POWERGRID as part of the business relationship, regarding plans, technical proposals and business details, including information contained or transmitted electronically.
d) The Bidder/Contractor of foreign origin shall disclose the name and address of the Agents/representatives in India, if any, involved directly or indirectly in the Bidding. Similarly, the Bidder/Contractor of Indian Nationality shall furnish the name and address of the foreign principals, if any, involved directly or indirectly in the Bidding.
e) The Bidder/Contractor will, when presenting his bid, disclose any and all payments he has made, or committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract and/or with the execution of the contract.
f) The Bidder/Contractor will not misrepresent facts or furnish false/forged documents/informations in order to influence the bidding process or the execution of the contract to the detriment of POWERGRID.
(2) The Bidder/Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 3 of 8
Section III- Disqualification from tender process and exclusion from future contracts
(1) If the Bidder, before contract award, has committed a serious transgression through a violation of Section II or in any other form such as to put his reliability or credibility as Bidder into question, POWERGRID may disqualify the Bidder from the tender process or terminate the contract, if already signed, for such reason.
(2) If the Bidder/Contractor has committed a serious transgression through a violation of Section II such as to put his reliability or credibility into question, POWERGRID may after following due procedures also exclude the Bidder/Contractor from future contract award processes. The imposition and duration of the exclusion will be determined by the severity of the transgression. The severity will be determined by the circumstances of the case, in particular the number of transgressions, the position of the transgressors within the company hierarchy of the Bidder/Contractor and the amount of the damage. The exclusion will be imposed for a minimum of 12 months and maximum of 3 years.
(3) If the Bidder/Contractor can prove that he has restored/recouped the damage caused by him and has installed a suitable corruption prevention system, POWERGRID may revoke the exclusion prematurely.
Section IV - Liability for violation of Integrity Pact
(1) If POWERGRID has disqualified the Bidder from the tender process prior to the award under Section III, POWERGRID may forfeit the Bid Guarantee under the Bid.
(2) If POWERGRID has terminated the contract under Section III, POWERGRID may forfeit the Contract Performance Guarantee of this contract besides resorting to other remedies under the contract.
Section V- Previous Transgression
(1) The Bidder shall declare in his Bid that no previous transgressions occurred in the last 3 years with any other Public Sector Undertaking or Government Department that could justify his exclusion from the tender process.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 4 of 8
(2) If the Bidder makes incorrect statement on this subject, he can be disqualified from the tender process or the contract, if already awarded, can be terminated for such reason.
Section VI - Equal treatment to all Bidders / Contractors
(1) POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
(2) POWERGRID will disqualify from the tender process any bidder who does not sign this Pact or violate its provisions.
Section VII - Punitive Action against violating Bidders / Contractors
If POWERGRID obtains knowledge of conduct of a Bidder or a Contractor or his subcontractor or of an employee or a representative or an associate of a Bidder or Contractor or his Subcontractor which constitutes corruption, or if POWERGRID has substantive suspicion in this regard, POWERGRID will inform the Chief Vigilance Officer (CVO).
(*)Section VIII - Independent External Monitor/Monitors
(1) POWERGRID has appointed a panel of Independent External Monitors (IEMs) for this Pact with the approval of Central Vigilance Commission (CVC), Government of India, out of which one of the IEMs has been indicated in the NIT/IFB.
(2) The IEM is to review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement. He has right of access to all project documentation. The IEM may examine any complaint received by him and submit a report to Chairman-cum-Managing Director, POWERGRID, at the earliest. He may also submit a report directly to the CVO and the CVC, in case of suspicion of serious irregularities attracting the provisions of the PC Act. However, for ensuring the desired transparency and objectivity in dealing with the complaints arising out of any tendering process, the matter shall be referred to the full panel of IEMs, who would examine the records, conduct the investigations and submit report to Chairman-cum-Managing Director, POWERGRID, giving joint findings.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 5 of 8
(3) The IEM is not subject to instructions by the representatives of the parties and performs his functions neutrally and independently. He reports to the Chairman-cum-Managing Director, POWERGRID.
(4) The Bidder(s)/Contractor(s) accepts that the IEM has the right to access without restriction to all documentation of POWERGRID related to this contract including that provided by the Contractor/Bidder. The Bidder/Contractor will also grant the IEM, upon his request and demonstration of a valid interest, unrestricted and unconditional access to his documentation. The same is applicable to Subcontractors. The IEM is under contractual obligation to treat the information and documents of the Bidder(s)/Contractor(s)/Subcontractor(s) with confidentiality.
(5) POWERGRID will provide to the IEM information as sought by him which could have an impact on the contractual relations between POWERGRID and the Bidder/Contractor related to this contract.
(6) As soon as the IEM notices, or believes to notice, a violation of this agreement, he will so inform the Chairman-cum-Managing Director, POWERGRID and request the Chairman-cum-Managing Director, POWERGRID to discontinue or take corrective action, or to take other relevant action. The IEM can in this regard submit non-binding recommendations. Beyond this, the IEM has no right to demand from the parties that they act in a specific manner, refrain from action or tolerate action. However, the IEM shall give an opportunity to POWERGRID and the Bidder/Contractor, as deemed fit, to present its case before making its recommendations to POWERGRID.
(7) The IEM will submit a written report to the Chairman-cum-Managing Director, POWERGRID within 8 to 10 weeks from the date of reference or intimation to him by POWERGRID and, should the occasion arise, submit proposals for correcting problematic situations.
(8) If the IEM has reported to the Chairman-cum-Managing Director, POWERGRID, a substantiated suspicion of an offence under relevant Anti-Corruption Laws of India, and the Chairman-cum-Managing Director, POWERGRID has not, within the reasonable time taken visible action to proceed against such offence or reported it to the CVO, the Monitor may also transmit this information directly to the CVC, Government of India.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 6 of 8
(9) The word ‘IEM’ would include both singular and plural.
(*) This Section shall be applicable for only those packages wherein the IEMs have been identified in Section – I : Invitation for Bids and/or Clause ITB 9.3 in Section – III: Bid Data Sheets of Conditions of Contract, Volume-I of the Bidding Documents.
Section IX - Pact Duration
This Pact begins when both parties have legally signed it. It expires for the Contractor after the closure of the contract and for all other Bidder's six month after the contract has been awarded.
Section X - Other Provisions
(1) This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under Integrity Pact.
(2) Changes and supplements as well as termination notices need to be made in writing.
(3) If the Contractor is a partnership firm or a consortium or Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venture partners.
(4) Nothing in this agreement shall affect the rights of the parties available under the General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
(5) Views expressed or suggestions/submissions made by the parties and the recommendations of the CVO/IEM# in respect of the violation of this agreement, shall not be relied on or introduced as evidence in the arbitral or judicial proceedings (arising out of the arbitral proceedings) by the parties in connection with the disputes/differences arising out of the subject contract.
# CVO shall be applicable for packages wherein IEM are not identified in Section IFB/BDS of Condition of Contract, Volume-I. IEM shall be applicable for packages wherein IEM are identified in Section IFB/BDS of Condition of Contract, Volume-I.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 7 of 8
(6) Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Witness 2 : Witness 2 :
Designation : Designation :
Integrity Pact Page 8 of 8
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-15
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
I We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1. Name of the Supplier/ Contractor in whose favour payment is to be made 0
2. Address with PIN Code and State
Registered Office:
Correspondence Address:
3. (a) Status – Company/others
[Declaration of Micro/ Small/ Medium Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
3. (b) Are you a MSE owned by SC/ST* entrepreneurs in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidence is to be attached. Please refer remarks at the end of the attachment. Yes
3. (c ) If 3(b) is ‘Yes’ please mention whether you are (Proprietary MSE/ Partnership MSE/ Private Limited Company) owned by SC/ST entrepreneurs
3. (d ) Are you a MSE owned by women in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012, Public Procurement Policy for Micro and Small Enterprises (MSEs) Amendment order 2018 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidence is to be attached.
4. Permanent Account (PAN) No.
5. GSTIN Numbers
I. GSTIN in the Sates/UT from where the supply of goods take place
Name of the States/UT GSTIN number
II. GSTIN in the States/UT where the supply for services take place (states where sites under the subject package is situated)
Name of the States/UT GSTIN number
6 PF Registration No. of the Company
7 PF Regional Office covered (with Address)
8 Name of Contact Person
9 Contact Details
10 Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account:
Type of Account: Current Account
11 9 digit MICR code printed at bottom in middle, next to cheque no.
12 IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
*The definition of MSEs owned by SC/ST is as given under:
a. In case of proprietary MSE, proprietor(s) shall be SC /ST.
b. In case of partnership MSE, the SC/ST partners shall be holding at least 51% shares in the unit.
c. In case of Private Limited companies, at least 51% share shall be held by SC/ST promoters.
Documentary evidence: Please provide scanned copy(ies) of the SC/ST certificate(s) issued by District Authority as applicable for SC/ST MSE category as per (a), (b) or (c) above.
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-16
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Additional Information)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(p)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Bidder (Sole Bidder) 0
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
2.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(p)(ii)]
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 Details regarding previous transgressions of Integrity Pact
The bidder should provide detailed information on any transgression of Integrity Pact that occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country.
3.1 Details regarding previous transgressions of Integrity Pact that occurred in the last 10 years
Year Name of client Details of Transgression of Integrity Pact by the bidder
4.0 OTHER INFORMATION
4.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
4.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
5.0 Details of Provident Fund Code Number of the Bidder [ref. ITB9.3(q)]
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-17
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Declaration for tax exemptions, reductions, allowances or benefits)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 B9, Qutab Institutional Area, Katwaria Sarai
0 New Delhi-110016
1 We confirm that we are solely responsible for obtaining following tax exemptions, reductions, allowances or benefits in respect of supplies under the subject package, in case of award. We further confirm that we have considered the same in our bid thereby passing on the benefit to POWERGRID while quoting our prices. In case of our failure to receive such benefits, partly or fully, for any reason whatsoever, the Employer will not compensate us.
2 We are furnishing the following information required by the Employer for issue of requisite certificate if and as permitted in terms of the applicable Govt. of India policies/procedures (in case of award):
Applicable Act, Notification No. and Clause Ref. No. Sl. No. Description of item on which applicable Country of origin Remarks, if any
(The requirements listed above are as per current Notification of Govt. of India indicated above. These may be modified, if necessary, in terms of the Notifications.)
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-17
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract & Materials
Name : …… ……. …….. …… ……. …….. Power Grid Corporation of India Ltd.,
Address : …… ……. …….. …… ……. …….. B9, Qutab Institutional Area, Katwaria Sarai
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-17
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract & Materials
Name : Power Grid Corporation of India Ltd.,
Address : B9, Qutab Institutional Area, Katwaria Sarai
New Delhi-110016
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-18
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
Safety Pact is attached herewith this Volume
Date : -- Printed Name :
Place : Designation :
Instruction for printing & submitting Safety Pact
1. The requisite format of Safety Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other six pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Safety Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (s).
Between #REF! #REF!
Power Grid Corporation of India Limited #REF! #REF!
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai, New Delhi – 110016 hereinafter referred to as #REF! #REF!
"POWERGRID", #REF! #REF!
0 1 having its Registered Office at ,
having its Registered Office at ,, 1 AND
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C) Specification Number:N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 1 of 6
POWERGRID values full compliance with all relevant laws and regulations and the principles of Safety, Health& Environment in its relations with its Bidders/ Contractors.
In order to achieve these goals, POWERGRID and the above named Bidder / Contractor enter into this agreement called “Safety Pact” which will form part of the Bid.
It is hereby agreed by and between the parties as under:
Section I - Commitments of POWERGRID
POWERGRID commits itself to take all measures necessary to prevent accidents duringConstruction and Operation of the Transmission Assets and to observe the following:
1. POWERGRID recognizes and accepts its statutory responsibilities for ensuring construction, operation and maintenance of equipments and for the provision of safe methods of work and safe working conditions.
2. POWERGRID recognizes and accepts its statutory responsibilities for ensuring safety of not only its employees but also that of the Contracting Agencies as Principal Employer.
3. POWERGRID shall review the accidents in a structured manner and take necessary actions to ensure that the safety criteria are strengthened for safe construction as well as Operation & Maintenance of the Transmission Assets.
4. POWERGRID shall conduct necessary awareness and training programmes to its Employees to augment the various safety requirements to be followed during Construction and Operation & Maintenance of the Transmission Assets from time to time.
5. POWERGRID shall, from time to time, issue necessary guidelines,instructions and deterrents to its employees as well as to the Contracting Agencies, to update them to take necessary preventive measures to avoid repetition of similar accident attributes.
6. POWERGRID shall review and provide necessary guidanceto the Contracting Agencies, as and when, any abnormality / special situations are brought to its notice by the Contracting Agencies during execution of the Transmission Projects being executed by them.
7. POWERGRID shall conduct periodical surveillance site inspections / audits to identify the unsafe conditions and unsafe actions, and bring them to the knowledge of the Contracting Agencies for taking timely corrective actions.
8. POWERGRIDshall investigate all accidents, fatal as well as non-fatal, to identify the lapses, the reason for the accident / incident and suggest measures for prevention of recurrence of such accidents, and fix responsibility for the lapses leading to the accident.
9. POWERGRID shall augment the training to the workers and supervising personnel of the Contracting Agencies, as per schedules, upon nomination by the Contracting Agencies in reasonable time frame.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 2 of 6
10. POWERGRID shall exercise the right to claim and recover compensation from the Contracting Agencies in case of any violation of the safety requirements / provisions during execution of the Transmission Projects, as built in the applicable Laws and contractual specifications / guidelines in vogue / issued by POWERGRID from time to time.
Section II – Commitments of the Bidder / Contractor:
The Bidder / Contractor commits himself to take all measures necessary to prevent / minimise accidents at their construction / erection sites and to observe the following:
1. The Bidder / Contractor recognizes and acceptsthe statutory and comprehensive responsibility for ensuring safe construction and Testing & Commissioning in the Transmission Projects being executed by thembyproviding safe methods of work, working conditions and Tools & Plants for human safety.
2. The Bidder / Contractor recognizes and accepts the responsibilities for ensuring safety of not only their employees but also that of the Sub-contractors, Principal Employer and the general public during execution of the Transmission Projects / works.
3. The Bidder / Contractor shall review the accidents in a structured manner and take necessary actions to ensure that the safety criteria are strengthened for safe construction of the Transmission Assets.
4. The Bidder / Contractor shall endeavour continuous development of safe methods of work to ensure that the effect of risks and perils are minimised to the extent possible and implement the same at their worksites.
5. The Bidder / Contractor shall conduct periodical Training to their Employees as well as to that of theirSub-contractors for safety awareness during construction works being executed by them.
6. The Bidder / Contractor shall provide all requisite Tools & Plants required for the work and ensure their healthiness by periodical inspections / testing as required. Unhealthy and sub-standard Tools & Plants will be immediately removed from site as and when they are identified.
7. The Bidder / Contractor shall,at their cost, provide all necessary Personal Protective Equipments such as Double Lanyard Safety Belts, Appropriate Fall Arrest Systems, Safety Helmets, Foot Wear, Hand Gloves, etc., as required for various activities pertaining to execution of the Projects / works, confirming to relevant Indian Standards.
8. The Bidder / Contractor shall ensure that dedicated qualified Safety Officers are posted in the construction projects being executed by them and ensure that the Safety Officer visits each and every gang periodically and conducts audits / inspections to identify the unsafe conditions and unsafe actions, to be rectified by the site supervising personnel promptly.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 3 of 6
9. The Bidder / Contractor shall conduct appropriate medical checks-up for the workers before deploying them at their construction sites to ensure that only those who are medically fit are deployed in the Projects / works to be executed by them. The copy of the Medical Reports shall be provided by the Bidder / Contractor to POWERGRID, whenever requested by POWERGRID.
10. The Bidder / Contractor shall screen the workers before deploying them at their construction sites to ensure that only those with the skills, experience and competence to work at heightand also medically fitfor work at height are deployed for work at height in the Projects executed by them.
11. The Bidder / Contractor shall ensure daily before starting the work thattheir site Supervising Personnel / Safety Officer briefs the workers about the work for the day and the safety measures / precautions required to be taken by them.
12. The Bidder / Contractor shall investigate all the accidents at their working sites to ascertain the lapses leading to the incident and the precautionary / corrective measures required to be taken to avoid recurrence of such accidents. These accidents will be reviewed at the Board Management level of the Agencies and the findings / recommendations will be put up to POWERGRID Apex Safety Board within the stipulated period.
13. The Bidder / Contractor shall ensure that all accidents, whether fatal or non-fatal in nature, will be informed to POWERGRID, in writing, immediately on the occurrence of the same,and in any case, within not more than 24 hours of occurrence of the same.
14. The Bidder / Contractor shall ensure that in case of any accident, all necessary medical help / supportshall be provided to the victims / injured till they are completely fit to return to work.
15. The Bidder / Contractorshall ensure that in case of fatal accidents, all statutory Authorities, including Police, concerned Labour Dept. Officials, concerned Workmen Compensation Commissioner, etc., will be intimated in writing as required by the statutory Law, and followed up for compliance of all statutory obligations. The Bidder / Contractor shall own full responsibility of timely accident reporting to various authorities, including POWERGRID.
16. The Bidder / Contractor shall ensure that in case of fatality or serious injury leading to permanent disablement of the victims, the compensation amount will be deposited with the concerned authorities, as required by the Laws, and followed up for early disbursement to the beneficiaries of the victims.
17. The Bidder / Contractor assures that they shall co-operate to the fullest extent for carrying out any investigation of the accidents at their work sites by POWERGRID to identify the lapses, the reason for the accident / incident and suggest measures for prevention of recurrence of such accidents. All factual details of the occurrence of the accident will be provided to POWERGRID, as and when required.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 4 of 6
18. The Bidder / Contractor assures that they take full responsibility of meeting the statutory obligations in case of accidents, and in case of any reference by any Statutory Body at a later date also, they shall provide all information to POWERGRID and meet all the statutory obligations, including payment of additional compensation, if any.
19. The Bidder / Contractor assures that in case of any inspection of their work site or Notice by any Statutory Authority, they shall comply promptly and inform POWERGRID Site Officials of the same, and also provide all necessary information and assistance for smooth compliance of the observations / instructions of such Authorities.
20. The Bidder / Contractor accepts the provisions regarding safety, including payment of compensation to POWERGRID, in case of any violation of the safety requirements / provisions during execution of the Transmission Projects, as built in the Contractual Conditions, Safety Planand the Safety Pact, and confirm to abide by the same.
Section III – Equal treatment to all Bidders / Contractors:
1. POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
2. POWERGRID will disqualify, from the tender process, any bidder/ take punitive actions on the bidder, who does not sign this Pact or violate its provisions.
Section IV – Pact Duration:
This Pact begins when both parties have legally signed it. It expires for the successful Bidder / Contractor after closure of the contract and, for all other Bidders, after the contract has been awarded.
Section V – Other Provisions:
1. This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under the Safety Pact.
2. Changes and supplements need to be made in writing, which shall come into force only upon mutual agreement / acceptance.
3. If the Contractor is a partnership firm or consortium of Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venue partners, as applicable as per the Tender Specifications.
4. Nothing in this agreement shall affect the rights of the parties available under General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
5. Should one or several provisions of this agreement turn out to be invalid, the reminder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 5 of 6
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Witness 2 : Witness 2 :
Designation : Designation :
Safety Pact Page 6 of 6
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Attachment-19
Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
Further, we hereby confirm that except as mentioned in the Attachment – 6 (Alternative, Deviations and Exceptions to the Provisions) hereof forming part of our First Envelope :
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/22-23/TBCB/OT/12 dtd.13.04.2022 Bid Form 1st Envelope 1 one 1 st 1 January
2 two 2 nd 2 February
BID FORM (First Envelope) 3 three 3 rd 3 March
4 four 4 th 4 April
Bid Proposal Ref. No. 5 five 5 th 5 May
Date : -- 6 six 6 th #VALUE! 6 June
7 seven 7 th #VALUE! 7 July
To: 8 eight 8 th #VALUE! 8 August
Contract & Materials 9 nine 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 ten 10 th 10 October
Northern Region-I, Reagional Headquarter 11 eleven 11 th 11 November
SCO Bay No. 5 to 10, Sector- 16 A 12 twelve 12 th 12 December
13 thirteen 13 th
14 fourteen 14 th
Name of Contract : Civil works for Package – II (Construction of Boundary wall, Security hut, main gate at entrance, Store, other ancillary civil works like approach roads, drains, etc.) under Regional package to be carried out at upcoming Sikar-II Substation under TBCB route under Transmission system strengthening scheme for evacuation of Power from Solar Energy zones in Rajasthan under Phase-II (Part-C) 15 fifteen 15 th
Dear Ladies and/or Gentlemen, Enter details here. 16 sixteen 16 th
1.0 Having examined the Bidding Documents, including Amendment Nos. ...[Enter the Amendment]… dated …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). ...[Enter the Amendment]… …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). 17 seventeen 17 th
1.1 We meet the eligibility requirements and have no conflict of interest in accordance with ITB Clause 2.
2.0 Attachments to the Bid Form (First Envelope) Bank Draft 18 eighteen 18 th
In line with the requirement of the Bidding Documents, we enclose herewith the following Attachments: Enter details here. Pay Order 19 nineteen 19 th
or documentary evidence in support of exemption of Bid Security, in separate envelope in accordance with clause 21 of ITB, Section-II." Please note that if bid validity is less than 06 (six) months, your bid may be rejected
(b) Attachment 2() : A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. Bank Guarantee (0) 21 st
*Further the requisite deed of Joint Undertaking as per stipulated qualification requirement in Annexure-A (BDS) has also been furnished as per your format.
* Delete if not applicable
(c) Attachment 3() : The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3(c) & (e), the qualification data has been furnished as per your format enclosed with the bidding documents [Attachment – 3(QR)]. 22 th
Further, the required Joint Venture Agreement signed by us and our Partners has also been furnished as per your format Attachment-3(JV). #REF! Applicable 23 th
Further the required deed of Joint Undertaking signed by us and Tower Manufacturer has also been furnished as per your format. 0 #REF! Not Applicable 24 th
(d) Attachment 4() : The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facilities offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 4. A list of Special Tools & Tackles to be used by us for erection, testing & Commissioning and to be handed over to Employer, the cost of which is included is our Bid Price, is also enclosed as per your format as Attachment 4A. A list of Special Tools & Tackles to be brought by the contractor for erection, testing & Commissioning and to be taken back after completion of work, whose cost in not included in our bid price, is enclosed as per your format as Attachment 4B. 25 th
(e) Attachment 5() : The details of all major items of services or supply which we propose subletting in case of award, giving details of the name and nationality of the proposed subcontractor/sub-vendor for each item. 26 th
(f) Attachment 5A() : Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises. 26 th
(g) Attachment 6() : The variation and deviations from the requirements of the Conditions of Contract, Technical Specification and Drawings (excluding critical provisions as mentioned at clause 6.0 below) in your format enclosed with the Bidding Documents, including, inter alia, the cost of withdrawal of the variations and deviations indicated therein. 27 th
(h) Attachment 7() : The details of Alternative Bids made by us indicating the complete Technical Specifications and the deviation to contractual and commercial conditions. (Not Applicable) 28 th
(i) Attachment 8() : Manufacturer’s Authorisation Forms. 29 th
(j) Attachment 9() : Work Completion Schedule. 30 th
(k) Attachment 10() : Guarantee Declaration. 31 st
(l) Attachment 11() : Information regarding ex-employees of Employer in our firm.
(m) Attachment 12() : Filled up information regarding Price Adjustment Data as per the format enclosed in the bidding documents.
(n) Attachment 13() : Declaration regarding Social Accountability.
(o) Attachment 14() : Integrity Pact, in a separate envelope, duly signed on each page by the person signing the bid.
(p) Attachment 15() : Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
(q) Attachment 16() : Additional Information.
(r) Attachment 17() : Declaration for tax exemptions, reductions, allowances or benefits
(s) Attachment 18() : Safety Pact
(t) Attachment 19() : Declaration.
(u) Attachment 20() : Declaration of Key Managerial Person jointly with Power of Attorney holder
(v) Attachment 21() : Self certification regarding Minimum Local Content in line with PPP-MII order and MoP Order December 2018, if applicable
(w) Attachment 22() : Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order, and MoP Order December 2018, if applicable
(x) Attachment 23() : Compliance to the process related to the e-RA
(y) Attachment 24() : Declaration by the bidder regarding events encountered pursuant to ITB Clause 2.1
(z-1) Attachment 26() : Bid securing Declaration
3.0 We are aware that, in line with Clause No. 27.1 (ITB), our Second Envelope (Price Part) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope.
4.0 We confirm that except as otherwise specifically provided our Bid Prices in Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
4.1 100% of applicable Taxes and Duties i.e. GST, which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
4.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
5.0 Construction of the Contract
5.1 We declare that we have studied Clause GCC 2.1 relating to mode of contracting for Domestic Bidders
6.0 We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us:
(a) ITB 13 Bid Security
(b) GCC 2.14 Governing Law
(d) GCC 55 Terms of Payment
(e) GCC 8.3 Performance Security
(f) GCC 6 Taxes and Duties
(g) GCC 38 Liquidated Damages for Delay by Contractor
(h) GCC 40 Defect Liability
(i) GCC 39 Guarantee
(j) GCC 20.5 Patent & Royalties
(k) GCC 61 Limitation of Liability
(l) GCC 57 Settlement of Disputes
(m) GCC 59 Arbitration
(n) Appendix 2 to Form of Contract Agreement Price Adjustment
Further we understand that deviation taken in any of the above clauses by us may make our bid non-responsive as per provision of bidding documents and be rejected by you.
7.0 We undertake, if our bid is accepted, to commence the work immediately upon your Notification of Award to us, and to achieve the delivery of goods and related services within the time stated in the Bidding Documents.
8.0 If our bid is accepted, we undertake to provide a Performance Security in the form and amounts, and within the times specified in the Bidding Documents.
9.0 We agree to abide by this bid for a period of six (06) months from the date fixed for opening of bids as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period.
10.0 Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
11.0 We understand that you are not bound to accept the lowest or any bid you may receive.
12.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions. 2
13.0 We are a Micro and Small Enterprise (MSE) registered with , a designated Authority of GoI under the Public Procurement Policy for MSEs order 2012. 2
14.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of 0
Date : -- Printed Name :
Place : Designation :
In case of bid from a Joint Venture, name & designation of representative of JV partner is to be provided and Bid Form is also to be signed by him
#REF! Printed Name :
#REF! Designation :
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
BOQ for Package (II) - Sikar-II S/s
Sl. No. Item Ref. DSR 2018/NS Item Description Unit Qty GST Rate (in Percent) Rate (Excl. GST) Amount (Excl. GST) Amount (Incl. GST)
(I) CIVIL WORKS
A Boundary wall & Security hut
0.0 NS Security Hut - Civil Works All civil works as per drawing and specifications complete, including - brickwork, finishing (external and internal), windows etc. However, excavation, PCC, RCC and reinforcement shall be paid separately as per BPS. Sq.m. 18 0.18
0.0 NS SEPTIC TANK & SOAKPIT FOR SECURITY ROOM NO. 1 0.18
0.0 NS Providing and fixing Pre cast RCC Boundary wall as per drawings and specifications, including centring, shuttering, moulding,RCC, reinforcement, casting, curing, hoisting, carriage of precast cols/panels to site,Excavation, PCC, backfilling,MS angles and Concertina coil etc. complete. Grating if any required shall be paid under Misc. structural steel. RM 3200 0.18
0.0 NS Providing and fixing main entrance gate as per drawings including Excavation, PCC, backfilling, RCC, reinforcement, MS steel, fabrication, painting etc complete LOT 1 0.18
0.0 NS 3.75m wide Bitumen road (including all crossings) complete as per drawing SQ.M. 500 0.18
0.0 NS RCC Culverts and drain crossings including supplying and laying hume pipe 250mm dia grade (NP-3) excluding Concrete as per specification M 20 0.18
0.0 NS Drain including culverts but excluding concrete & reinforcement steel - Section A-A M 250 0.18
0.0 NS Drain including culverts but excluding concrete & reinforcement steel - Section B-B M 50 0.18
C Store Building
0.0 NS Pre Engineered building closed Store for AIS spares: Design preparation of shop drawings, supply of all materials, fabrication, erection & commissioning of PEB Store Building. The work includes design and construction of foundations, plinth beams, brickwork, external & internal finishing, floor finishing, doors, windows, rolling shutters etc. complete in all respects as per the approved design, drawings and Technical specifications. However, excavation, PCC, RCC and reinforcement shall be paid under relevant item of BPS. Sq.m. 360 0.18
0.0 NS Pre Engineered building partially closed Store for AIS spares: Design preparation of shop drawings, supply of all materials, fabrication, erection & commissioning of PEB Store Building. The work includes design and construction of foundations, plinth beams, brickwork, external & internal finishing, floor finishing, doors, windows etc. complete in all respects as per the approved design, drawings and Technical specifications. However, excavation, PCC, RCC and reinforcement shall be paid under relevant item of BPS. Note: Opening detail as per TS Cl. 9.3.3 sq.m 360 0.18
D Common Items for A to C (as applicable)
0.0 NS Excavation in all types of soil and rock including backfilling disposal etc.for all leads and lifts Cu.Mtr. 1695 0.18
0.0 NS Providing and laying of Plain Cement Concrete (PCC) (1:4:8) Cu.Mtr. 153.8 0.18
0.0 NS Providing and laying of Plain Cement Concrete (PCC) (1:2:4) Cu.Mtr. 35 0.18
0.0 NS Providing and laying of Reinforced Cement Concrete M-25 including pre cast, shuttering, Grouting of pockets & underpinning but excluding steel reinforcement Cu.Mtr. 545 0.18
0.0 NS Steel Reinforcement MT 54.5 0.18
0.0 NS Misc. Structural steel including rails, embedments, edge protection angles, gratings etc. but excluding the reinforcement steel and steel for lattice and pipe structures. MT 1.75 0.18
(II) ELECTRICAL WORK
0.0 1.10.2 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B Point 34 0.18
0.0 1.12 Wiring for light / power plug with 2X4 Sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Metre 60 0.18
a 1.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Metre 160 0.18
a 1.18.2 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair Metre 200 0.18
0.0 1.19 Supplying and drawing co-axial cable TV RG-6 grade 0.7mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required. Metre 200 0.18
a 1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm Metre 200 0.18
a 1.22.2 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 100 mm X 100 mm X 60 mm deep Each 4 0.18
a 1.24.1 5 amps switch Each 16 0.18
1.24.A 6 amp switch Each 4 0.18
b 1.24.4 3 pin 5/15 amp socket outlet Each 20 0.18
c 1.24.6 Telephone socket outlet Each 4 0.18
d 1.24.7 T.V. antenna socket outlet Each 3 0.18
0.0 1.25 Suplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Each 7 0.18
a 1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75 mm X 75 mm) Each 20 0.18
1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100 mmX75 mm) Each 10 0.18
0.0 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required. Each 4 0.18
0.0 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required. Each 4 0.18
0.0 1.38 Supplying and fixing call bell/ buzzer suitable for D.C./A.C. single phase, 230 volts, complete as required. Each 2 0.18
0.0 1.41 Installation, testing and commissioning of pre-wired, fluorescent fitting/LED/ compact fluorescent fitting of all types, comlete with all accessories and tube etc. directly on celing/ wall, including connection with 1.5 Sq. mm FR PVC insulated, copper conductor, sigle core cable and earthing etc; as required. Each 11 0.18
0.0 1.35 Erection of wall bracket/ceiling fittings of all sizes and shapes containing LED lamps per fitting, complete with all accessories including connection etc. as required. Each 9 0.18
0.0 1.45 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 Sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. Each 4 0.18
a 1.50.1 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Up to 450 mm sweep Each 1 0.18
0.0 1.51 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. Each 1 0.18
0.0 2.4.3 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way SPN Each 2 0.18
0.0 2.10.1 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole Each 16 0.18
0.0 2.13.3 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 amps 4 P Isolator Each 2 0.18
0.0 2.21 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Each 2 0.18
0.0 5.11 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with GI nut, bolt, spring, washer excavation and re-filling etc. as required. Metre 20 0.18
a 14.16.5 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 200 mm dia (OD-200 mm & ID-175 mm nominal) Metre 20 0.18
0.0 CIVIL DSR 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3mm dia, round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing. each 8 0.18
0.0 NS Supply installation, testing and commissioning of Krone type tag block of 10 pair complete with back mount frame, modules, etc in a lockable metal box including connection etc, as required Each 2 0.18
a NS Supplying and fixing 18W LED tube essential on batten (Cat No. TMC 501 P1& T LED 22W P3241 for batten & Cat No. Essential Led tube M/s Philips & Similar. Each 11 0.18
b NS Supplying and fixing 10 Watt LED recess down lighter round ( philips cat No. DN 191B LED 65-4000 PSU WHSI or similar Each 2 0.18
c NS Surface mounted 1x11 Watt CFL mirror Lights fitting Bajaj Cat No. BJC111 WEBI or similar. Each 2 0.18
d NS 33W LED recess square fitting similar to Philips Cat No. RC370B LED 285 6500 Each 2 0.18
NS BL(Surface Mounted Bulk Head) 18W fitting Philips or similar approved 6 0.18
a NS Supplying and fixing FAN - 1200 mm sweep Each 7 0.18
a NS Supplying and fixing 300 mm ventilating Fan Each 2 0.18
0.0 NS Supply and installation of wall bracket fan of 300mm, sweep complete with fan motor, blades etc. with all accessories etc. of approved make as required.(Make : Bajaj / Crompton / Havells) Each 2 0.18
Total for CIVIL WORKS
TOTAL for ELECTRICAL WORKS
TOTAL OF CIVIL & ELECTRCALS
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
Price_schedule.xlsx
xlsx • 0.48 MB
01_1st Envelope-attachment.xlsx
xlsx • 1.45 MB
02-Attachment-14-IP.doc
doc • 0.07 MB
03-Attachment-18-SAFETY PACT.docx
docx • 0.05 MB
04_Attachment-20_KMP Declaration-Pkg-A.doc
doc • 0.04 MB
05-Attachment-21- Affidavit for Self Certifictaion.docx
docx • 0.02 MB
06-Attachment-23-Compliance to the process related to the e-RA.docx
docx • 0.02 MB
07-Attachment -24_Declaration regarding events encountered.docx
docx • 0.04 MB
9-Legends.pdf
pdf • 0.03 MB
Thumbs.db
db • 0.02 MB
1 Seurity Hut Main Gate Septic tank and Soak pit.pdf
pdf • 0.79 MB
2 Boundary Wall.pdf
pdf • 4.29 MB
3-1 ROAD.pdf
pdf • 0.10 MB
3-2 Road Culvert.pdf
pdf • 1.50 MB
6 Drain.pdf
pdf • 2.24 MB
PEB store building Drawing.pdf
pdf • 2.09 MB
List of cement make.pdf
pdf • 0.23 MB
List of Indicative Makes for materials.doc
doc • 0.16 MB
SCC for pkg-II works SIKAR-II.doc
doc • 0.10 MB
Sikar-II-GA Rev based on amd-15.10.20.pdf
pdf • 0.17 MB
TS for the Civil Work Package-II.docx
docx • 0.10 MB
TS Pkg-II SIK-II ELECTRICAL.doc
doc • 0.10 MB
BOQ-SIKAR PKG-II.xls
xls • 0.05 MB
Standard Field Quality Plan Civil Works for Site Packages Revision 04.pdf
pdf • 2.19 MB
01-Section - I IFB SSTE Vol-I.docx
docx • 0.04 MB
02 Section - II ITB SSTE civil(Feb 2019).docx
docx • 0.09 MB
03-Section - III_BDS.docx
docx • 0.05 MB
04-Annexure-A (BDS)-QR.doc
doc • 0.07 MB
04-Annexure-B (BDS).docx
docx • 0.02 MB
04-Annexure-D (BDS).docx
docx • 0.03 MB
05-GCC-civil works(Feb 2019).doc
doc • 0.37 MB
06-Section - V_SCC .doc
doc • 0.13 MB
07-Appendix -I to SCC.doc
doc • 0.17 MB
08-Section - VI Forms and Proceedures Vol-I.doc
doc • 0.40 MB
Thumbs_1.db
db • 0.02 MB
~$ Section - II ITB SSTE civil(Feb 2019).docx
docx • 0.00 MB
~$-GCC-civil works(Feb 2019).doc
doc • 0.00 MB
~$-Section - I IFB SSTE Vol-I.docx
docx • 0.00 MB
~$-Section - VI Forms and Proceedures Vol-I.doc
doc • 0.00 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .