Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69.5 LAccepted-AOC NO 4 AC 114 EAST OF NGEF OPP THE KARNATAKA STATE APEX CO OPERATIVE BANK KASTURI NAGAR BANGALORE 560043 | BANGALORE | BANGALORE | KARNATAKA | 560043 | L1 | Accepted-AOC awarded value after deducting schedule of credit being lowest bid | |
| 2 | L2₹69.7 L+₹6,930 (0.10%)Rejected-Finance NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-Finance Being not lowest Bid | |
| 3 | L3₹78.0 L+₹8.4 L (12.1%)Rejected-Finance NO 111 BHARATH NAGAR M S PALYA VIDYARANYAPURA VIDYARANYAPURA BANGALORE KARNATAKA 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L3 | Rejected-Finance Being not lowest Bid | |
| 4 | L4₹78.4 L+₹8.8 L (12.7%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BANGALORE | BANGALORE | KARNATAKA | 560085 | L4 | Rejected-Finance Being not lowest Bid | |
| 5 | L5₹78.7 L+₹9.1 L (13.1%)Rejected-Finance 20 1ST A CROSS SAI NAGAR AREHLLI UTTARHALLI BANGALORE 560 061 | BENGALURU URBAN | KARNATAKA | 560061 | L5 | Rejected-Finance Being not lowest Bid |
Tender Value
₹81.7 L
EMD Value
₹1.5 L
Closing Date
26 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer RnD Secunderabad
Chief Engineer RnD Picket Secunderabad
PROVISION OF SETTING UP OF DEVELOPMENT AND TESTING OF INFORMATIONS SECURITY SOLUTIONA AT CAIR BANGALORE
2022_MES_571002_1
82636
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Bangalore
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE West Bangalore
₹1.5 L
Yes
29 Mar 2023
23 Dec 2022
2 Feb 2023
23 Dec 2022
26 Jan 2023
19 Jan 2023
Amount
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc laid , bedded & pointed in any mortar removing serviceable stone slabs to store and rubbish off the premises all as specified and as directed by the Engineer-in-Charge.
M&L Non skid ceramic colour tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.1 and n.exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in CM(1:6) all as specified and as directed by the Engineer-in-Charge.
Preparation of old decorated plastered / unplastered surfaces of walls, cement pillars etc brooming down with steel/wire brushes, scaping down smoke,soot,moulds moss and effloresenct salts trading, greasy spots etc and apply one coat of oil bound distemper complete all as specified and directed.
S&F aluminium, powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. Complete all as specified.
S&F aluminium powder coated door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. Complete all as specified.
M&L for 9mm thick,Pre-laminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed in cup board shutters,Aluminium partitions.
S&F sheet glass, 4.80mm thick,exc 0.50 sqm in square/rectangular in each pane, ordinary quality fixed to aluminium frame work and glazing with beads/ metal pins complete all as specified and as directed by the Engineer-in-Charge.
Taking down existing old point wiring light/fan/ socket/bell/ power point, surface or concealed type as per site alongwith fittings & fixtures and making good disturbed surfaces of walls and floors complete all as specified and directed by Engineer-in-charge etc.
M & L for Point Wiring complete with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable 1100 volts grade drawn through in and including non metallic rigid PVC medium grade concealed conduit of minimum 25 mm external dia and shall be increase as per actual site requirement in accordance to clause 19.125 of SSR Part-I ,ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends,tees, junction boxes etc fixed concealed in wall or ceiling etc including cutting chase to wall /floor/ beam of suitable depth and size and making good the disturbed surfaces after putting conduits in chases including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable 1100 volts as earth continuity wire and modular type metal flush box of GI with cover plate and frame of required module for mounting Modular type switches, sockets, fan regulators of any modules complete all as specified and directed by Engineer-in-charge etc. for the following :-
(a) one light /celing fan and exhaust fan point controlled by one, one way switch.
(b) one 3/5 pin socket outlet 6 Amps on the same board controlled by one, one way switch.
(c) one 3/5 pin socket outlet 6 Amps on independent board controlled by one, one way switch.
M & L for Point Wiring complete with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable 1100 volts grade drawn through and including non metallic rigid PVC medium grade concealed conduit of minimum 25 mm external dia and shall be increase as per actual site requirement in accordance to clause 19.125 of SSR Part-I ,ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends,tees, junction boxes etc fixed concealed in wall or ceiling etc including cutting chase to wall /floor/ beam of suitable depth and size and making good the disturbed surfaces after putting conduits in chases including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable 1100 volts as earth continuity wire and modular type metal flush box of GI with cover plate and frame of required module for mounting Modular type 16 Amps switches, 16 Amps sockets complete all as specified and directed by Engineer-in-charge
S & F modular type switch single pole one way 6 Amps one module (ISI Marked) complete all as specified and directed by Engineer-in-charge
S & F modular type switch single pole one way 16 Amps one module (ISI Marked) complete all as specified and directed by Engineer-in-charge
Supply and fix modular type socket flush type 5 Pin 6 Amps 2 module 240 volts complete all as specified and directed by Engineer-in-charge
Supply and fix modular type socket flush type 6 Pin 6/16 Amps 2 module 240 volts complete all as specified and directed by Engineer-in-charge
supply and fix Ceiling rose surface bakelite, 65 x 50 mm three terminals 230 volts AC Single phase complete all as specified and directed by Engineer-in-charge
S&F ceiling recessed type as per site conditions LED fitting 36watt of fixture size 2x2 feet with intgrated electronic driver complete with all acc essories internaly prewired and including connecting up twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-charge. Make:Cat no LCTRNE-36-FO-CDL of crompton/ Cat no PLANO 2x2 PLR36 WLED 857 S of Havells/ Cat No BZRSQL 36L LED GXCW of Bajaj or techno equivalent of Philips/Wipro
S&F ceiling surface type type as per site conditions LED fitting 36watt of fixture size 2x2 feet with intgrated electronic driver complete with all acc essories internaly prewired and including connecting up twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-charge. Make:Cat no LCTLSNE-36-FO-CDL of crompton/ Cat no PLANOSURFACE 2x2 PLS36 WLED 857 S of Havells/ Cat No BZSSQL 36L LED WHGH of Bajaj or techno equivalent of Philips/Wipro
Supply & fixing Air circulator wall fans 230 volts single phase oscillating type 450 mm sweep suitable for wall mounting complete all as specified and directed by Engineer-in-charge
Material and labour submain wiring with two runs of 4.0 Sqmm single core multistranded PVC insulated unseathed conductor cable FRLS 1100 Volts grade with copper conductor, drawn through and including concealed rigid PVC conduit medium grade ISI marked 25 mm external dia butshall be increase as per actual site requirement in accordance to clause 19.125 of SSR Part-I ,ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends,tees, junction boxes etc fixed concealed in wall or ceiling etc including cutting chase to wall /floor/ beam of suitable depth and size and making good the disturbed surfaces after putting conduits in chases including 4.0 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable 1100 volts drawn as earth continuity wire and connecting to common earth dolly complete all as specified and directed by Engineer-in-charge etc.
Material and labour submain wiring with two runs of 6.0 Sqmm single core multistranded PVC insulated unseathed conductor cable FRLS 1100 Volts grade with copper conductor, drawn through and including concealed rigid PVC conduit medium grade ISI marked 25 mm external dia but shall be increase as per actual site requirement in accordance to clause 19.125 of SSR Part-I ,ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends,tees, junction boxes etc fixed concealed in wall or ceiling etc including cutting chase to wall /floor/ beam of suitable depth and size and making good the disturbed surfaces after putting conduits in chases including 6.0 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable 1100 volts drawn as earth continuity wire and connecting to common earth dolly complete all as specified and directed by Engineer-in-charge
Material and labour submain wiring with 4 runs of 10 Sqmm single core multistranded PVC insulated unseathed conductor cable FRLS 1100 Volts grade with copper conductor, drawn through and including concealed rigid PVC conduit medium grade ISI marked 25 mm external dia butshall be increase as per actual site requirement in accordance to clause 19.125 of SSR Part-I ,ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends,tees, junction boxes etc fixed concealed in wall or ceiling etc including cutting chase to wall /floor/ beam of suitable depth and size and making good the disturbed surfaces after fixing conduits in chases including 2 x 10 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable 1100 volts drawn as earth continuity wire and connecting to common earth dolly complete all as specified and directed by Engineer-in-charge
S&F MCCB DB wall mounted Double Door VTPN DB 4 Way 440 Volt 3 phase MCCB incomer type with minimum 200 Amps rated Bus Bar including one Nos of MCCB 4 pole 100 Amps, 25 KA as incomer and MCB,s as outgoing including necessary dummy plate complete all as specified and directed by Engineer-in-charge Note: Out going MCB's as applicable shall be measured and paid seperately.
S&F Double Door DB SPN 8 Way 240 Volt with manufactureres rated Bus Bar including necessary dummy plate complete all as specified and directed by Engineer-in-charge
S&F Double Door DB SPN 12 Way 240 Volt with manufactureres rated Bus Bar including necessary dummy plate complete all as specified and directed by Engineer-in-charge
S & F MCB SP 10 to 40 Amps, 'C" curve suitable for 240 Volt 50Hz complete all as specified and directed by Engineer-in-charge
S & F MCB SPN 40 Amps 'C" curve suitable for 240 Volt 50Hz complete all as specified and directed by Engineer-in-charge.
S/F Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal)but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers lock nuts, saddles, pipe hooks etc of not less than 25 mm external dia concealed in walls, ceiling floors etc for LAN / Telephone wiring complete all as specified and directed by Engineer-in-charge Note: The cost of cutting /chasing on wall etc as applicable shall be deemed to be included in the unit rate quoted.
Supply and fix PVC junction boxes ( 1 to 4 ways) suitable of 25 mm conduit complete all as specified and directed by Engineer-in-charge
Supply and fix LAN port RJ 45 Cat 6 with modular box cover plate complete all as specified and directed
Supply and fixing, telephone jack with shutter, RJ 11, including modular box cover plate with frame, complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cmX60cmX6.3 mm thick buried in ground vertically to a depth not less than 2.25 metre below normal ground level, normal with top edge of earth plate not less than 1.5 metre below normal ground level, earth plate connected to a galvanised earth lead wire 4mm dia bymeans of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I (2009) connected to earth test point all as specified or indicated including testing on completion with and including 15 mm bore light grade GI protection pipe 7.5 meters long or upto test point for earth including PCC 1:2:4 pit with pre cast RCC 1:2:4 type B1 cover 40 mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hook made out of 6mm dia MS bars watering arrangement by providing GI pipe 20mm dia medium grade with funnel wire, common salt and charcoal filling, necessary excavation and earth work in any type of soil complete all as specified and directed by Engineer-in-charge
Supply and laying of computer LAN category-6 multi core cable ( 4 pair unshielded twisted pair cable) with high density polyethylene insulation, paired , fire retardant as IS/IEC 11801drawn through concealed non metallic rigid PVC conduit complete all as specified and directed by Engineer-in-charge Note: PVC conduit shall be measured and paid seperately
Supply and lay, telephone cable, 5-pair, with high density polyethelene insulated, solid annealed high conductivity bare copper with dia 0.5 mm, paired, polyester taped and sheathed conforming to ITD Specifications, drawn through concealed non metallic rigid PVC conduit complete all as specified and directed. Note: PVC conduit shall be measured and paid seperately
Supply and Fixing Exhaust fan AC single phase 240 Volt 50 Hz of size 380 mm sweep metallic grade with louvers and necessary electric connection from ceiling rose to exhaust fan complete all as specified and directed by Engineer-in-charge
Material and Labour earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthling etc. as required 4 mm dia galvanised iron or steel wirecomplete all as specified and directed by Engineer-in-charge
Supply, Install, Testing and Commissioning inverter type 5 star rated (of manufacturers year 2023) adjustable type Hi wall split unit with indoor/outdoor units of capacity 2.0 TR complete with cordless remote control unit, with in built filter for better indoor air quality complete all as directed. Note (1) - The quoted rate is deemed to be inclusive for the following items of work:- (a) S&F copper piping of suitable size with best quality insulation, drain out PVC pipe and control cables upto 7 metres. (b) S&F outdoor unit bracket factory made powder coated suitable for 2 Ton AC. Note (2) :- Copper piping control cable and PVC waterdrain pipe beyond 7 metres shall be measured and paid seperately under relevent item.
Supply and fix sheet metal enclosure DP with a two pin and earth plug socket with one double pole MCB 32 Amp, 230 V, 10 KA, C Curve..
S &F Install Testing and Commissioning Votage stabiliser of rating 5 KVA Single phase voltage range 170 V - 250 V, wall mounting type, naturally air cooled, automatic operation with output voltage stabilized at 230 volts with accuracy +/- 2.5%.
Supply laying and testing copper piping 1/4" with best quality insulation material complete.
Supply laying and testing copper piping 5/8" with best quality insulation material complete.
Supply laying and testing copper cable 1.5 sq mm 4 core complete.
Supply laying and testing drain water piping with 25 mm PVC pipe with fittings complete all as directed
Taking down old unserviceable MCB DB's along with MCB of any type after disconnecting electronic connection all as directed.
Taking down old unserviceable sub main wiring of any type complete all as directed
UNIVERSAL ENGINEERING
Meghana and Gowda Enterprises
Lucky Enterprises
K. VENKATESH NAIDU
B5BUILDING SOLUTIONS
M/S KVG CONSTRUCTIONS
Vinayaka Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .