Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.9 LAccepted-AOC HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹43.4 L+₹42,792 (0.99%)Rejected-Finance MANEGAON DIWAN BADA KHAMARIA JABALPUR M P PIN 482005 | JABALPUR | MADHYA PRADESH | 482005 | L2 | Rejected-Finance Highest amount quoted | |
| 3 | Rejected-Technical 950 1 GF DEVRAJ BUILDING NAPIER TOWN NAVEEN VIDHYABHAWAN ROAD DAYANAND SARASWATI WARD JABALPUR M P 482001 | JABALPUR | MADHYA PRADESH | 482001 | - | Rejected-Technical Rejected due to non enlistment in required category |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
9 Jun 2022, 6:00 pmClosed
Shri Dhiraj Kumar, IDSE, EE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
As per BOQ
2022_MES_522981_1
8414/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer (East) Jabalpur
D a(i) and b (i)
7 documents required · 7 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹84,000
Yes
6 Jul 2022
11 May 2022
11 Jun 2022
11 May 2022
9 Jun 2022
26 May 2022
11 May 2022 - 17 May 2022
Amount
S&F rolled mild steel in framing for cladding glazing framing work or similar work including necessary cutting drilling welding etc fixed with angle cleatsand connecting plates confirmimg to FE 290 (GDE E-165) Complete all as specified.
S&F weldedsteel wire fabric and fixed complete to steel members weights not exceeding 4 kg/Sqm Complete all as specified.
Mild steel screw bolts (machine made) 5 mm to 10 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long.
M&L plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone agg) as in filling under undulation of roof top/chajja/beam incl necessary formwork complete all as specified and directed.
S&F Butt hinges 75 mm size, medium weight, cold rolled mild steel.
S&F M S handles 100mm size, cast type, anodised.
S&F M S barrel tower bolts 150mm long of extruded section.
Cutting hole by drilling for fixing of bolts of fix the cage plate 4 nos hole for cage by of the monkey cage and filling with epoxy grouting as per complete and matching with exiting surface all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately under relevant items here-in-before.
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc.
M&L Preparation of new steel sufaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved shade over one coat of red oxide primer not otherwise described including rubbing out and cleaning rust on new steel surfaces Complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 25 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 40 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
S&F 20 mm bore GI tubes, 'medium grade' galvanised, with all fitting and fixed complete including cutting, chaising, pinning and making good to walls and ceiling or laid in floors.
Refixing old 20 mm dia steel tubing including cleaing and connections with all fitting in new or old position (wall, ceilling, floor etc).
S&F 25 mm boreGI tubes, 'medium grade' galvanised, with all fitting and fixed complete including cutting, chaising, pinning and making good to walls and ceiling or laid in floors.
Refixing old 25 mm dia steel tubing incl cleaing and connections with all fitting in new or old position (wall, ceilling, floor etc).
S&F 40 mm boreGI tubes, 'medium grade' galvanised, with all fitting and fixed complete tincl cutting chaising pinning and making good to walls and ceiling or laid in floors.
Refixing old 40 mm dia steel tubing incl cleaing and connections with all fitting in new or old position (wall, ceilling, floor etc).
S&F Ball valves 20mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe & fixed. (minimum weight 20mm-210 gms).
S&F 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
S&F 25 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
S&F 40 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core Make:- Havells or Finolex or Gloster or Plaza or Universal as approved by GE.
Supply and laying cable XLPE insulated screened PVC bedded, galvanised steel strip or wire, armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor 95 Sqmm 3.5 core. Make:- Havells or Finolex or Gloster or Plaza or Universal as approved by GE.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core Make:- Havells or Finolex or Gloster or Plaza or Universal as approved by GE.
Supply and laying cable XLPE insulated screened PVC bedded, galvanised steel strip or wire, armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor 50 Sqmm 3.5 core. Make:- Havells or Finolex or Gloster or Plaza or Universal as approved by GE.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 50 to 70 sqmm, Indoor/Outdoor type. Make:- Denson, M,seal,Raychem.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 95 to 120 sqmm, Indoor/Outdoor type. Make:- Denson, M,seal,Raychem.
Excavation in trenches in soft loose soil including cutting road surfaces n.exc 1.5 mtr wide and n.exc. 1.5 mtr in depth for poles, stay, cable, pipe etc getting out all as specified.
Returning filling including spreading and well ramming in layers each n.exc 25 cm thick in soft loose soil all as specified.
Removal of surplus/spoil on a distance n.exc 25 cm thick in soft loose soil all as specified.
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm laid in trenches for under ground cable all as specified.
M&L for Sand cushioning trenches using fine sand to under ground cable, laid in two layers 15 cm before laying the cable & 8cm after laying the cable complete all as specified.
M&L for cable protection GI tubing light grade fixed long the pole/under road/along the wall of size 80 mm bore with necessary clamps all as directed.
M&L for Earthing complete with galvanized steel earth plate electrods of size 60cm x 60cm x 6mm thick burried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.50 mtr below normal ground level connected to galvanised iron strip 32 x 6 mm as earthing lead by means of bolts nuts check nuts and GI washers of Galvanised iron protected by steel pipe 15mm (light grade) all as shown in elecrrical plate No. 3 of SSR Part-I and connecting to earthing test point (earth test point to be provided at 5 mtr distance from earth pit) and testing on completion including necessary excavation and earth work. The rate also include charcoal dust and comman salt in alternate layers 25 mm dia light grade GI pipe, funnel, wire mesh. concrete 1:3:6 type C-1 for pit and RCC pit cover. PCC pit shall be provided 50 cm away from earth pit and not on the earth pit itself. The extra cost of the watering pipe, bends, elbows shall be included in the unit rate. Note : RCC pit cover shall be precast of RCC 1:2:4 type B-1 80mm thick reinforced with XPM weighing not less than 4 Kg/Sqm.
Schedule of credit amount of Rs. 8,550.00 to be deducted during AOC.
M/S BHATIA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .