| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC MEHEM ROAD NEAR TVS BIKE AGENCY GOHANA SONIPAT HARYANA 131301 ON MEHAM ROAD NEAR TVS BIKE AGENCY GOHANA 131301 | SONIPAT | HARYANA | 131301 | ₹1.3 Cr | L1 | Accepted-AOC Ok |
| 2 | L2₹1.3 Cr+₹5.6 L (4.34%)Rejected-Finance RAILWAY ROAD 9 10 KC MARKET 132001 2021R66 | KARNAL | HARYANA | 132001 | ₹1.3 Cr+₹5.6 L (4.34%) | L2 | Rejected-Finance Not responsive |
| 3 | L3₹1.4 Cr+₹14.7 L (11.4%)Rejected-Finance GURUGRAM | GURUGRAM | HARYANA | 122001 | ₹1.4 Cr+₹14.7 L (11.4%) | L3 | Rejected-Finance Not responsive |
| 4 | L4₹1.5 Cr+₹23.3 L (18.1%)Rejected-Finance | ₹1.5 Cr+₹23.3 L (18.1%) | L4 | Rejected-Finance Not responsive |
| 5 | L5₹1.8 Cr+₹54.5 L (42.2%)Rejected-Finance | ₹1.8 Cr+₹54.5 L (42.2%) | L5 | Rejected-Finance Not responsive |
Tender Value
₹1.4 Cr
EMD Value
₹2.7 L
Closing Date
19 Feb 2021, 5:00 pmClosed
Executive Engineer
CCS HAU, Hisar
Providing Undeground 11 KV HT cable line in place of existing overhead 11 KV HT Line at CCS HAU Campus, Hisar
2021_HRY_159016_1
3200
Open Tender
Civil Works
Works
60 days
CCS HAU HISAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹15,000
₹2.7 L
Yes
12 Mar 2021
8 Feb 2021
20 Feb 2021
8 Feb 2021
19 Feb 2021
8 Feb 2021
Amount
Earth work in excavation in foundations, trenches etc. in all kinds of soils, not exceeding 2 meters depth including dressing of bottom and sides of trenches stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 meters.( HSR 6.6 )
Cement Concrete 1:8:16 with stone aggregate 40mm nominal size in foundation and plinth ( HSR 10.28 )
Cement Concrete 1:2:4 with stobe aggregate 20mm nominal size for reinforced concrete work in slabs excluding steel reinforcement but including centring and shuttering laid in position complete in all respect +extra over item no. 10.79+10.94 if 1:1.5:3 mix is used instead of 1:2:4 ( HSR 10.87+10.95 )
Precast cement concrete 1:2:4 with stone aggregate 20mm nominal size in tiles & channels and the like items , finished smooth with 6mm thick cement plaster 1:3 on exposed surface i/c form work placing and fixing in position complete at the ground level or in first storey +extra over item no. 10.79+10.94 if 1:1.5:3 mix is used instead of 1:2:4 (HSR 10.78+10.95)
Steel work, fixed independently without connecting plates, including cutting, hoisting and fixing in position in :-{HSR 18.1 (c)} (c) Tees, angles and channels
Wrought iron and mild steel (using angles, flats, square bars, tees and channels) ladders, grills, grating frames, windows guards, iron doors open-able or fixed stair case or parapet or any other type of railing, gates and tree guards etc. including cost of screws and welding rods or bolts and nuts complete fixed in position. (HSR 18.12)
Supply MS bolts of required sizes with nuts and washers complete. (HSR 18.15)
S/E of PVC copper insulated and sheathed 2 core circular flexible wire. {HSR 31.9 (i) (b)} (b) Size 0.75 sqmm (24/0.20mm)
Moulded case circuit breakers Supply and erection of moulded case circuit breaker on wall or on existing pedestal including bonding to earth and necessary connections:- {HSR 31..12 (c)(ii)} (ii)100 amp. To 220 amp.415V 10 K.A
(iv) 300 amp. To 400 amp. 415 V 35 K.A 3 phase {HSR 31..12 (c)(iv)}
MCB / Isolator :- S/E of MCB / Isolator 240/415 V in the existing distribution board including making necessary connections {HSR 31.17 (ii)} (ii) 6 amp to 32 amp MCBs SP
S/E of PVC pipe of 6 KG pressure, laid 1 meter below ground level complete, including digging refilling of the trench with jointing etc. {HSR 31.21(xxx) (a)} (a) PVC pipe 120 mm dia
Earthing:- (i) Earthing with GI earth pipe 4.5 mtr long and 40 mm dia with masonry enclosures on the top etc. as required. {HSR 31.22(i)}
(ii) Extra for using salt and char coal / coke for pipe earth electrode as required. {HSR 31.22(ii)}
(iv) Earthing with tinned copper earth plate 600 x 600 x 3 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without char coal or coke and salt) etc. complete as required. {HSR 31.22(iv)}
(v) Extra for charcoal or coke and salt for GI plate or copper plate earth electrode. {HSR 31.22(v)}
(x) Pdg. and fixing 25 x 5 mm copper strip in 40 mm dia GI pipe from earth electrode as required. {HSR 31.22(x)}
(xii) Pdg. & laying earth connetions from earth electrode with 4 mm dia Gi wire in 15 mm dia GI pipe from earth electrode as required. {HSR 31.22(xii)}
(xiv) Pdg. & fixing 25 x 5 mm copper strip on surface or in recess for connections etc. as required with all labour and material. {HSR 31.22(xiv)}
S/E of under ground cable 1 mtr below gound level covered with sand and bricks including necessary connections, digging and refilling of trenches, compection watering etc. {HSR 31.25(xxiv)} (xxiv)95 sqmm 3½ core cable (Armoured)
(xxxii)185 sqmm 3½ core cable (Armoured) {HSR 31.25(xxxii)}
(xxxiv) 300 sqmm 3½ core cable (Armoured) {HSR 31.25(xxxiv)}
S/E of under ground cable, loose in existing pipe or trenches, compection watering etc. complete with necessary connections {HSR 31.26(xxix)} (xxix)95 sqmm 3½ core cable (Armoured)
(xxxii)185 sqmm 3½ core cable (Armoured) {HSR 31.26(xxxii)}
(xxxiv) 300 sqmm 3½ core cable (Armoured) {HSR 31.26(xxxiv)}
(xl) 16 sqmm 4 core (Armoured) {HSR 31.26(xl)}
Miscellaneous S/E of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work. {HSR 31.28 (ii)} (ii)16 sqmm
(iv) 70 Sqmm {HSR 31.28 (iv)}
(iv) 95 Sqmm {HSR 31.28 (iv)}
(v)120 Sqmm {HSR 31.28 (v)}
(v) 150 Sqmm {HSR 31.28 (v)}
(v)185 Sqmm {HSR 31.28 (v)}
(vii)300 Sqmm {HSR 31.28 (vii)}
SITC of wall / free standing floor mounting dust and vermin proof comopartmentalized cubical panel made out of 2 mm thick CRCA sheet, required hardware 3 mm thick Bkt sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted etc. (HSR 31.63 )
Supplying and fixing of copper busbar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing to same in existing panel including bending, cutting in required shape and size and insulation with colour coding heat shrinkable PVC insulation complete in all respect. (HSR 31.64)
S/E of mark double walled corrugated (DWC) HDPE pipe laid 1 mtr below ground level including diging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of the work.{HSR 31.67 (i)} (i) HDPE pipe 63/50 mm outer dia / inner dia.
S/E of Hot Dip Galvanized octagonal pole of 3 mm thickness with base plate including cost of nut and bolts and all accessories as supplied by the manufacture including cost of foundation accessories etc. The foundation bolts as per manufacturer design should be hot dipped galvanized pole complete with door locking arrangment. Terminal plate consisting of 2 Nos 100 A, 4 Pole natural links including connection etc. with suitable connecting arrangement for 2 No MCBs / Kitkat including cost of RCC 1:1, 5:3 for foundation of size 0.7 M x 0.7M x 1.8 M with minimum 8 Nos 12 mm dia longitudinal MS reinforcement rods with rings of 8 mm dia not more than 200 mm CC for fixing the pole with all labour & material required to complete the job in all respect Etc.{HSR 31.68 (i)} (i) 7Mtr long pole with top dia 70 mm and bottom dia 130 mm with base plate of size 220 x 220 x 12 mm
S/E of MCCB single pole / 4 pole on wall or on existing pedestal including bounding to earth and making necessary connection required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work.{HSR 31.69 (v)} (v ) MCCB 4 Pole 100 amp 25KA
(vii) MCCB 4 Pole 300 to 400 amp {HSR 31.69 (vii)}
S/E of XLPE (E) 11 KV HT aluminium conductor armoured cable ISI mark laid in 1 meter below ground level with sand & bricks with all labour and material including digging and refilling of trenches, compection watering etc., required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work.{HSR 31.70 (i)} (i) 35 sqmm 3 core XLPE Cable
(ii) 50 sqmm 3 core XLPE Cable {HSR 31.70 (ii)}
(v) 120 sqmm 3 core XLPE Cable {HSR 31.70 (v)}
S/E of XLPE (E) 11 KV HT aluminum conductor armoured cable ISI mark laid in existing pipe / trenches / surface with all labour and material required to complete the job in all respect upto entire satisfaction of the Engineer in charge of the work.{HSR 31.71 (i)} (i) 35 sqmm 3 core XLPE Cable
(ii) 50 sqmm 3 core XLPE Cable {HSR 31.71 (ii)}
(v) 120 sqmm 3 core XLPE Cable {HSR 31.71 (v)}
S/E of heat shrinkage type end termination kit outdoor type of suitable to accommodate 3 core 11 KV XLPE aluminum cable / ABC cable complete with all the kit contents including earth continuing connection along with 3 Nos crimpling type aluminum lugs of suitable capacity including making jointing etc. complete in all respect.{HSR 31.73 (i)} (i) Suitable for 16 to 50 sqmm 3 core XLPE cable
(ii) Suitable for 70 to 120 sqmm 3 core XLPE cable {HSR 31.73 (ii)}
Dismantling of HT line stay set and return to store.(NS)
Dismantling of ABC cable from 11 mtr long PCC pole and return to store.(NS)
Dismantling of ACSR conductor 50 sqmm from 9/11 mtr long PCC pole and return to store.(NS)
Dismantling of 9/11 Mtr PCC pole and return to store.(NS)
S/E of GI pipe 4" dia (B-Class) (NS)
S/E of Trenchless boring of road by HDD machine for laying required size of HDPE Pipe 6" (160mm PN6 Type ) with socket , reducer as per dia of cable at the ende of pipe to closed the end of pipe to avoid entering of sand in pipe and all petty material reuired to complete the job as per entire satisfaction of the Engineer-in-charge.(NS)
Providing & fixing precast RCC (1:1½:3) cable route marker of size 0.75 mtr. Deep/ 0.25 mtr. Width 0.15 mtr. Thick 0.25 mtr below top of side wall and proper embedded in wall. The writing words, H.T. cable on three sides of route markers including arrow on two sides with approved make of enamel paint of red colour including white colour Apex of approved make 6 Nos horizontal stirrups for tor steel bar 8 mm dia and 6 Nos vertical tor steel bar 12 mm dia as instruction and as per entire satisfaction of the Engineer-in-charge. (NS)
Providing & fixing G.I. inerlocking fencing of size 3" x 3" or any other size made of 10 gauge wire fixed with RCC post by means of MS flat & amp; bolts / nuts (Items of MS flat and bolts / nuts shall be paid separately under HSR) including drilling holes in MS flatetc, complete in all respects as per architectural drawing and design. (NS)
S/E of coarse aggregate for concrete or stone ballast from quarried stone of size 53mm to 22.4mm.(NS)
S/E of 3 core straight through joint HVT type suitable for existing 120 sqmm 11 KV (E) screened XLPE cable complete in all respect to the entire satisfaction of Engineer-in-charge.(NS)
S/E of single arm street light bracket of size 1.5 Mtr long made of 32/50 mm dia GI pipe B-Class ISI, with coller pipe (GI) 75 mm dia 300 mm long duly welded, painted with 2 coats of aluminium paint on bracket for fixing on the existing 7 mtr Hot Dip Galvanaized ocatagonal pole complete with all labour and material required to complete the job in all respects etc. (NS)
S/E of LED street light of system voltage ≤ 70 W IP 66 Multiple LED with lens optics and pressure die-cast aluminium housing for effective thermal management. Total system lumen of ≤ 70 watt LED should be 7000 or above in cool day light (5700K), Lumen efficacy > 110 lm/W, Power factor ≥ 0.95, CRI ≥70, Average life ≥50000 hours, complete with all acessories as required with connections on existing street light / PCC poles including 3 year defect liability period and free replacement in case of non functioning of the light fixture.(NS)
Erection of ACSR/Insulated ACSR on existing 11M Pcc Pole including erection of iron structure pin insulators carried from store complete in all respect . (NS)
Erection 11M PCC pole with iron structure , insulators and supporting material & PCC Pole carried from store complete in all respect required to complete the work in all respect.(NS)
S/E of double arm street light bracket of size 1.5 Mtr long made of 32/50 mm dia GI pipe B-Class ISI, with coller pipe (GI) 75 mm dia 300 mm long duly welded, painted with 2 coats of aluminium paint on bracket for fixing on the existing 7 mtr Hot Dip Galvanaized ocatagonal pole complete with all labour and material required to complete the job in all respects etc. (NS)
POMERA AND CO LTD
N D ELECTRICAL
SHREE SAI INTERNATIONAL
RAM JEE POWER ELECTRONIC SYSTEMS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .