Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | ₹5.6 L Quoted ₹5.8 L | L1 | Accepted-AOC Being L1 and reasonable |
| 2 | L2₹7.6 L+₹1.8 L (31.3%)Rejected-Finance NO 22 KUNNIJI NAGAR 1ST STREET EAST TAMBARAM CHENNAI 600 059 TAMIL NADU | CHENNAI | CHENNAI | TAMIL NADU | 600059 | ₹7.6 L+₹1.8 L (31.3%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹8.1 L+₹2.3 L (40.0%)Rejected-Finance | ₹8.1 L+₹2.3 L (40.0%) | L3 | Rejected-Finance Being L3 |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
28 Oct 2024, 6:00 pmClosed
AGE (I) NAVY CHENNAI
AGE (I) NAVY CHENNAI MILITARY ENGINEER SERVICE FORT SAINT GEORGE, RAJAJI SALAI, CHENNAI -600009
REPAIRS REPLACEMENT OF CEILING FANS, EXHAUST FANS, PEDESTAL FANS, METERS, WATER HEATERS AND MAINT OF VOLTAGE STABILIZER AT ZONE C (INS PALLAVA AND PTC K) UNDER AGE(I) NAVY CHENNAI
2024_MES_676805_1
8579/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
INS PALLAVA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
AGE (I) NAVY CHENNAI
₹18,000
Yes
24 Mar 2025
26 Sept 2024
29 Oct 2024
26 Sept 2024
28 Oct 2024
10 Oct 2024
Amount
Taking down old unserviceable copper/aluminium point wiring (light, fan, socket or power) including old unserviceable fixture and fittings complete etc removing the materials for taking credit and making good the disturbed surface of wall/floor etc.
Point wiring with 1.5 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single core FRLS drawn into and including non-metallic rigid PVC conduit / PVC Casing Caping suitable size, FRLS wiring, along with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof excluding Modular Metal flush box / PVC Modular Box and white cover plate with frame the switches, sockets, fan regulator etc as required suitable for Modular type fitting /fixture etc which shall be measured and paid separately all as specified and directed for :-
(a) One light point or fan/Exhaust fan point controlled by one regulator / one switch
(b)One 3 pin socket outlet 5 amps socket on independent board with cables 1.5 sq. mm size
Supply and Fix modular socket modular 2/3 pin 6 A flush type 2 module.
Supply and fix Modular switch flush type single pole one way 10 A, 240 Volts complete all as specified and as directed including taking down old unserviceable switches.
Supply and fix in repair ceiling rose 3 ways PVC / Polycarbonate, isolated body complete all as specified and as directed.
Supply and fix in repair Stepped type Modular electronic fan regulator 120W, 2 Module flush type on the existing phenolic laminated sheet etc complete including taking down old unserviceable electronic fan regulator and removing the material for taking credit all as specified and directed.
Fixing only after repair fan regulator supply and connecting
Supply only condenser 2.5 MFD (for Ceiling Fan) complete all as specified and directed. (Make : Usha/Keltran/uptran)
Supply and fix in repair wall mounted fan sweep 400mm,RPM 1300, single phase 220V , Oscilation angle in Degree 90 complete al as specified Engineer in Charge.
Taking down after disconnection of electrical connections etc of the existing wall mounting fan of any size of any make and checking for fault and hanging back after carry out all repair works including connecting up complete all as specified and directed by Engineer in Charge
Rewinding of wall mounting fan of any type and make, stator coil with super enameled copper winding wire of appropriate gauge / quantity of burnt stator coil.
Supply and fix only ball bearing
Supply and fix only capacitor of 4 mfd for wall mounting fan
Supply and fix only condenser holder
Scrubbing / removing the existing paints from the wall mounting fan 400 mm sweep and painting the fan with two coats of synthetic enameled paint over a coat of metal oxide primer.
Supply and fix in repair exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers
Taking down after disconnection of electrical connections etc of the existing Exhaust fan 300mm / 450mm sweep of any make and checking for fault and fixing back in position after carrying out all repair works including connecting up complete all as specified and directed by Engineer in Charge
Rewinding of exhaust fan 250/300mm sweep stator coil with super enameled copper winding wire of appropriate gauge / quantity of burnt stator coil complete all as specified and directed by Engineer in Charge
Rewinding of exhaust fan 450mm sweep stator coil with super enameled copper winding wire of appropriate gauge / quantity of burnt stator coil.
Supply and fix only ball bearing for 250/300/450mm sweep Exhaust fan. .
Supply and fix only suitable capacitor for 250/300/450mm sweep Exhaust fan.
Scrubbing / removing the existing paints from the exhaust fan 300/ 450mm sweep and painting the fan with two coats of synthetic enameled paint over a coat of metal oxide primer.
Supply and fix only new fan blades set for 250/300 mm sweep fan.
Supply and fix only new fan Blades for exhaust fan of 380 to 450mm sweep.
Fixing only exhaust fan after repair and connecting up including provision of cable from ceiling rose/connector to fan.
Removing the damaged and corroded exhaust fan louvers and replace with new louvers of size up to 300mm sweep complete all as specified and directed.
Supply and fixing in repair ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
Taking down after disconnection of electrical connections etc of the existing ceiling fan 1200mm sweep of any make and checking for fault and hanging back after carry out all repair works including connecting up complete all as specified and directed by Engineer in Charge
Rewinding of ceiling fan 1200mm sweep stator coil with super enameled copper winding wire of appropriate gauge / quantity of burnt stator coil.
Supply and fix only ball bearing for ceiling fan 1200mm sweep.
Supply and fix only capacitor of 2.5 mfd for ceiling fan 1200mm sweep.
Supply and fix only condenser holder.
Supply and fix new rubber shackle with bolt nut split pin complete.
Supply and fix Ceiling fan Rod any size
M&L Scrubbing / removing the existing paints from the ceiling fan 1200 mm sweep and painting Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etccomplete all as specified and directed by Engineer in Charge.
Hanging only ceiling fan after repair and connecting up including provision of cable from ceiling rose or connector to fan.
Supply and fix in repair electronic meters temper proof LCD display with polycarbonate cover 3 phase 415 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH
Supply and fix in repair electronic meters temper proof LCD display with polycarbonate cover single phase 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH
Taking out the voltage stabilizer of any make and of capacity 4/5 KVA from site and transporting to servicing centre to detect /identify the nature of defects/repairs and reassembling after repair/servicing and commissioning at site including testing the same to the entire satisfaction of Engineer-in-Charge complete all as specified and directed.
Dismantling the burnt out transformer from the 5 KVA capacity stabilizer of any make and rewinding the same with supper enamelled copper wire including provision of all materials and refixing into the stabilizer and testing to the entire satisfaction of Engineer-in-Charge and testing complete all as specified and directed.
All as per Sl item No 40.00 herein before but capacity 4 KVA.
Supply and fixing relay set of two for voltage stabilizer up to 5 KVA capacity complete all as specified and directed.
All as per Sl item No 42.00 here-in- before but PCB (printed circuit board).
All as per Sl item No 42.00 here-in -before but 3 core flexible card 2.5 Sqmm.
All as per Sl item No 42.00 here-in- before but indicating lamp.
Taking down carefully old unserviceable submain wiring with aluminum conductor cable in PVC conduit complete removing the materials and taken as credit and making good the disturbed surface of wall / floor etc.
Supply and fix repairs Modular switch 1 way 16A, 1 module 240 Volts complete all as specified and as directed.
S & F modular White cover plate with frame,1 module
S&F Metal flush box 1/2 module
S&F for sub main wiring/power wiring with 2 runs of 4 sqmm PVC insulated stranded copper conducotr FRLS cable and one run of 4sqmm copper FRLS cable as earth lead in PVC conduit all as specified.
M&L for sub main wiring with 2 runs of 2.5 sqmm PVC insulated stranded copper conducotr FRLS cable and one run of 2.5 sqmm copper FRLS cable as earth lead in suitanle PVC conduit all as specified.
Supply and fix Sheet metal enclousers with socket plug top and MCB SP 20A, 240 volts, with a two pin and earth plug socket complete with one single MCB 20 Amps, 240 volts (for AC ) including taking down old unserviceable old unserviceable Sheet metal enclousers with socket plug top complete all as specified and directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning
(i) SP 6 To 32 AMP
(ii) SPN 32 AMP
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.
M&L Cable with copper conductor PVC round sheathed (flexible) industrial cable size 4sqmm including taking down old unserviceable.
Taking down defective storage water heater of any capacity from buildings after disconnecting carefully water and electric connection, opening the bottom cover replacing the defective parts fixing the cover and refixing in original position reconnecting both water and electric connection and testing complete all as specified and directed. Notes :- Replacement of spares will be measured and paid for separately under respective items of the schedule here-in-after as supply only.
Supply and Fix only new heating element of capacity 1.5KW/2KW with rubber gasket complete all as specified and directed.
Supply and fix only thermostat suitable for storage type water heater complete all as specified and directed.
Supply and fix only Pressure release valve 15mm dia suitable for geyser complete all as specified and directed.
Supply and only Air release valve 15mm dia suitable for geyser complete all as specified and directed.
Supply and fix only Non return valve 15mm dia suitable for geyser complete all as specified and directed.
Supply and fix only Apparatus plate assembly suitable to fix thermostate, heating elements as of geyser and nuts etc complete all as specified and directed.
Supply and fix only Fusible plug
Supply and fix lamp indicator
Anchor bolt for fixing Heater
Sri Sankar Enterprises (BID ID -3152055)
Vantage System and Sevices (BID ID -3140424)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .