Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
1 Apr 2020, 6:00 pmClosed
GE NW NOFRA
DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI-05
REPAIR REPLACEMENT OF STREET LIGHT POLES AND ITS CONNECTED ITEMS AT CERTAIN LOCATIONS UNDER GE (NW) NOFRA COLABA MUMBAI AND REPAIR REPLACEMENT OF HELIPAD STREET LIGHT AT INS SHIKRA AND LED STREET LIGHT IN NT POOL UNDER GE (NW) NOFRA COLABA MUMBAI
2019_MES_309628_3
8722
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
MUMBAI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NW NOFRA
₹99,000
Yes
8 Apr 2020
12 Mar 2020
6 Apr 2020
12 Mar 2020
1 Apr 2020
12 Mar 2020
Amount
REPAIR/ REPLACEMENT OF STREET LIGHT POLES AND ITS CONNECTED ITEMS AT CERTAIN LOCATIONS UNDER GE (NW) NOFRA, COLABA, MUMBAI
Taking out broken, damaged/ rushted street light poles of any kind/make/ length ( steel tubular/ PCC poles) complete along with street light fitting and pole arms with all accessories including necessary excavation, breaking PCC, returning/ filling and removing surplus soil out of MD land complete all as specified and directed by EIC .
Supply and fixing in repair Steel tubular swaged street light poles complete with pole arms 1.2 m & cast iron base plate ,finial taper plug,bolts,nuts and screws as specified type 410 SP-31 , 9.0 mtr long and painting with two coat of aluminium paint over one coat of primer on exposed surface of pole complete all as specified and directed by Engr-in-Charge. (NOTE- Excavation & PCC will be measured and paid separately) Make of poles:- National Tubing Co./ Bombay Tubing Ltd / India Tube and Co. / Bharat Conduit & Steel Works.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation, filling mass concrete including necessary form work. complete all as specified and directed.
M&L for PCC 1:3:6 type C 1 using 20 mm graded aggregate block masonry with solid block ,exc 10 cm in width and setting in mortar complete for coping of pole including necessary from work and fair finish to the exposed surface area without using extra cement complete all as specified and directed.
Supply and fix FRP type looping box of size 280 x 170 x 130 mm with necessary arrangement to fix the looping box with the suitable size of cable glands with entry, nuts,bolts, washers flat iron including 3 core 2.5 sqmm wire from looping box to light fitting connector etc comprising of the followings:- (a) MCB, 63 Amps TP ( 10 KA) (C series ) - 01 No. (b) MCB, 5 to 30 Amps, SP (10 KA) (C series) - 01 No. (c) Neutral link - 01 No.
Supply and lay 40 mm dia GI tubing light grade for cable protection at road crossing/ hard standing/ plinth protection/ on the pole etc complete all as specified and directed. Make of GI pipes- Tata/ Jindal/Zenith.
Taking down existing unserviceable street light fittings and supply & fixing LED street light fittings 120 watts in aluminium pressure die cast housing with touched glass cover with IP 66 protection including wiring complete all as specified & directed. Make - Jaquar lighting Cat No - LSRT01S120XW or its equivalent make in Philips / Havells.
Taking up old U/S XLPE/PVC insulated armoured and PVC sheathed electric cable 1100 volts grade heavy duty with stranded aluminium cable from trenches/walls/ceiling/ poles etc any size complete all as specified and directed
Supply, laying, commissiong & testing XLPE insulated armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.0 core 10 Sqmm laid in trenches/ through pipe/ ducts or fixed on wall etc complete all as specified and directed. Make of Cables- Polycab/ Finolex / Havells
Supply, laying, commissiong & testing XLPE insulated armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 35 Sqmm laid in trenches/ through pipe/ ducts or fixed on wall etccomplete all as specified and directed. Make- Polycab/ Finolex / Havells
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation, laying of UG Electric cable / staying of steel tubular pole etc. and getting out in soft and loose soil, complete all as specified and as directed .
All as per item No.12.00 above but in hard/dense soil (road/hard standing etc)
Cutting existing road surface or hard standing 0.45 mtr depth (22 cm thick comprising bituminous topping) for laying of pipes/ cables and making good distrubed surface to match with existing complete all as specified and directed .
Removing the excavated material/ soil not exc 50m out of MD land complete all as specified and directed .
Returning & filling in, including spreading, levelling, watering & well ramming in layers not exc 25 cm as in soil complete all as specified & directed .
Supply and Fixing of HDPE pipe of pressure rating 6kgf/cm2 of 40 mm dia including necessary bends , elbows , Tees etc on cable protection complete all as specified and directed . Make of HDPE pipe: Finolex , Dutron ,Prayag.
Supply and Fixing of HDPE pipe of pressure rating 6kgf/cm2 of 25 mm dia including necessary bends , elbows , Tees etc on cable protection complete all as specified and directed . Make of HDPE pipe: Finolex , Dutron ,Prayag.
Taking Down and Material & Labour for Earthing with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, burried directely in ground (earth pit not less than 2.5 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 32 x 6 mm with the help of bolts, nuts, check nuts and washers of galvanised iron or steel, including necessary excavation, PCC 1:3:6 type D2 and PCC cover 1:2:4 type B1 watering arrangement with GI pipe funnel, jali, complete all as specified and shown in electrical plate No.3 including connection to the earthing test point and testing on completion.
Supply and fix of Digital time switch- Astro for switching on/off lights and other electric devices according to the rising / setting of the sun or with combination function for creating switching programs in which the devices are switched according to astronomical time and / or fixed preset times / daily astronomical calculation of the sunrise/sunset times based on the entered location or location coordinates complete all as specified and directed. Make of digital time Switch: Legrand Cat No 4126 54 AlphaRex3 D21 astro or its equivalent make in Havells/ L&T.
Supply and fix of Power contactor 40 Amps 2 No, confrom to IEC/EN 61095 complete all as specified and directed. Make of Power contactor : Legrand Cat No 4125 45 or its equivalent make in Havells/ L&T.
REPAIR/ REPLACEMENT OF HELIPAD STREET LIGHT AT INS SHIKRA & LED STREET LIGHT IN NT POOL UNDER GE (NW) NOFRA, COLABA, MUMBAI
Excavation in trenches not exceeding 1.5 Mtrs. wide and not exceeding 1.5 Mtrs. in depth for foundation, laying of cablesetc and getting out in hard/dense soil complete all as specified and directed.
Removing excavated material (Soil) n.exc 50 m and depositing where directed at a level n. exc 1.5 Mtrs. above the starting point complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc. 25cm depth in soil complete all as specified and directed.
Supply only in Repair of Energy efficent and super saver lamp suitale for rotating beacon sysytem. Make as per Existng Sample or its equivalent as approved by GE.
Supply only in repair of Isolation transformer,series to series 200 w, 5000 volts,current ratio 6.6/6.6 amps suitable for Helipad identification light (CCR) Light fittings complete all as specified and directed by EIC.
S &F LED aviation light luminaires integral LED aviation light comprising of aluminium housing with polycarbonate enclosure,302 nos. LED are provided as per site Required Make of LED aviation light : Bajaj CAT PART NO-BGAV 302 LED or its equivalent in Havells/ Phillips.
S & F in Repair aviation obstruction light yellow painted die cast aluminium alloy housing ,built in 75 VA step up transformer, heat resistant,clear thick glass and accessories complete with neon lamp 75 VA with provision of necessary GI pipe for fixing including taking down from hanger/security post,product no 020075 of type BJAOL. Make : Phillips/ Bajaj / Wipro.
Supply fix/erect in repair wind cone assembly (wind direction indicator) with bottom base plate and steady burning red obstruction light mounted on top,made of water repellent and resistant to rotating and mildew nylon fabric with colour combination red and white complete of size dia is 600 mm, the dia of small end is 300 mm and length is 2.4 mtr. Make shall be of AMA / Mtech system / ctech/ cazonil / schenzhen or any other equivalent make as approved by GE.
Taking down/dismantling voltage stablizer of capacity up to10 KVA,415 Volts carefully from its original position and repair & overhauling carrying with fallowing all as specified and directed by Engr -in -charge.
(a) Draining out oil from Voltage Stablizer and dismantling the core connections from tank and taking out core along with winding from tank carefully.
(b) Cleaning the oil tank of voltage stablizer and removing sludges from tank.
(c) Dismantling the faulty winding from the core and re-winding to same with suitable size of insulated copper wire as per manufacturers specification.
(d) Core shall be assembled with suitable insulated hardware and insulating material varnishing and re-assamling all parts respect to original position etc.
(e) Refilling of new transformer oil and filter to achieve the BDV Values and testing complete all as directed.
(f) Inspecting/overhauling value of spring drive Mechanism by checking mechanism,lever assembly and apply multy grease lubricant to function smoothy.
Supply & fix in repair Industrial highbay integral LED fittings of capacity 120 watt complete and all accessories at top of any height of workshop hanger including proper hanging fixing with angle/rond bar flat iron with clamping as good appearnce complete all as specified and directed by Engr-in-charge. Make- Jaquar lighting Cat No - LHBL090120XW or its equivalent make in Philips / Havells.
Supply & fix in repair 120 watt Energy saving environmental friendly, long life,exclusive innovative die cast aluminium IP65 flood light with high power LEDs as light source,suitable for high lighting architectural façade highmast and general purpose. Make- Jaquar industrial light Cat No - LFLD02S0120XW or its equivalent make in Philips / Havells.
Taking down existing unserviceable street light fittings and supply & fixing LED street light fittings120W with pressure die cast housing with lens touched glass cover with IP 66 protection including wiring complete all as specified & directed. Make - Jaquar street light Cat No - LSRT01S120XC or its equivalent make in Philips / Havells.
S&F cable junction boxes IP 66/67 weather proof for out door installation(with knock outs cable entry junction box size should be 205x255x112 with terminals including complete all accessories specified and directed. Make -Hensel cat part no-KF 2525 G or its equivalent as approved by GE.
M&L for scraping the old Painted surfaces and spray painting of LT Pole of 9/11 Mtrs with two coat of synthetic enamel paint of approved colour complete with all fitting etc all as specified and directed by Engr in charge.
S &F in repair 45 watt LED new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting Source and LENs embedded toughned glass cover with IP66 Protection and impact resistance of IK07. Make Jaquar cat part No. LSRT01S045XW or its equivalent Make in Phillips/Havells.
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 2 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make - Legrand cat No 507791 or its equivalent in siemens / GE. (Note : The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc is included in quated rate)
Repai/replacement of old unserviceable pply and fixing LED post top integral pole mounted decorative LED post top upto 30Watt with IP65 protection suitable for 40mm dia GI tubing including all s specifed and directed. Make- Philips Cart part No BGP161LED2500/NW PSU 220-240V 7043 IN or its equivalent make in Havells/ Jaquar
S & F in replacement of MCB,SPN 40 Amps capacity, B Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as directed. Make-Legrand,siemens,GE
S & F MCCB, 415 volts, 3 pole of cap 100 Amps, 25 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat part no 420005 or its equivalent in siemens/GE
S&F HDPE of Pressure rating 6kgf/cm2 pipe of 40 mm dia including necessary bends,elbows,Tees etc on cable protection complete all as specified and directed.
S & F of MCCB sheet metal enclosure suitable for holding MCCB of 100 amp capacity four pole type including fixing accessories etc complete all as directed. Make - Legrand cat part no -607906 or its equivalent in siemens / GE .
S & F of MCCB sheet metal enclosure suitable for holding MCCB of 160 amp capacity four pole type including fixing accessories etc complete all as specified and directed. Make - Legrand cat part no -607944 or its equivalent in siemens / GE .
S & F in replacement 63 Amps Triple pole and earth encolsure with a three pin and earth plug with socket complete with one single pole MCB. Make -Legrand Cat part no -507864 or its equivalent in siemens / Indo Asian.
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting TPN 4 way, 440 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s etc complete all as specified and directed. Make - Legrand cat part no 607735 or its equivalent in siemens/GE (Note : The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc is to be included in quated rate)
S & F in replacement of MCB 6 to 32 Amps capacity, B Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed. Make- Legrand/ Siemens /Havells
S & F in replacement of MCB, 4 Pole, 63Amps capacity, B Curve type suitable for 415 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed. Make : Legrand Cat Part no-408702 or its equivalent in Siemens / GE
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 2 core. laid in duct / along pole/wall etc including making connection complete all as directed. Note : The cost of Al thimbles/lugs and cable gland etc shall be included in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10sq mm 2 core. laid in duct / along pole/wall etc including making connection complete all as specified and directed. Note : The cost of Al thimbles/lugs and cable gland etc shall be included in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core. laid in duct / along pole/wall etc including making connection complete all as directed. Note : The cost of Al thimbles/lugs and cable gland etc shall be included in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed. Note : The cost of Al thimbles/lugs and cable gland etc shall be included in quoted rate and no extra payment will be made for it.
Routine maintenance of air field Runway light System (AFLS) by attending fault testing of system,regularly basis to ensure serviceability & checking of system etc ,including replacement of unserviceable component including preventive maintenance spares by replacing parts other than mention in Schedule "A" installed at dispersal area INS Shikra with comprising following:-
(a) Mantinance of runway light circuit no1 and 2 Approx consists of 65 runway lights including repairing & cleaning of lighting system complete.
(b) Maintinance of constant current Regulator (CCR) unit and line stablizer 230 volt,50hz,10 kw,single phase.
(c) Maintinance of Remote control unit at ATC.
(d) Maintinance and Repairing,cleaning and replacement of holder/lamp of flood light fittingred/blue light.
(e) Maintenance and Repairing,cleaning of blue and red light.
(f) Maintinanceof obstruction light at any height of building/Hanger etc.
ORIENT ELECTRIC CO
NOEL ENGINEERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .