| Sl No | Description | Qty | Unit | VATANUCOOL ENGINEERS L2 | PANWAR ELECTRICALS L1 |
|---|---|---|---|---|---|
| 1.00 | Periodical servicing/maintenance of floor mounted Air Handling Unit (AHU) of capacity 8338 CFM by carrying following works :-
(i) Removal of air filters (primary & secondary) from filter section, removal of dirt/dust partical by compressed air blower followed by washing under running tap water and refixing at site after complete dry .
(ii) Removal of dirt/dust particals from aluminium fins of cooling coil by soft brushing followed by air blowing and cleaning of cooling coil by forced spray chemically (such as veni clean solution) all as directed by Engineer-in-Charge.
(iii) Cleaning & removing of complete scale from bottom tray and drain pipe of AHUs as directed at site by the Engineer-in-Charge.
(iv) Cleaning of drain pipe from AHUs tray to out side plant room manually as well as any de-scaling solution for draining.
(v) Checking serviceability/tightening of fan motor V-belt, pulley block, fan blades assembly.
(vi) Checking serviceability/tightening of AHU door lache and greasing/oiling. | 3 | Each Job | 1,500 ₹1,500 Lowest | 15,000 ₹15,000 |
| 2.00 | All as per Item No. 1.00 here-in-before but for floor mounted AHU of capacity 8342 CFM. | 3 | Each Job | 1,500 ₹1,500 Lowest | 15,000 ₹15,000 |
| 3.00 | All as per Item No. 1.00 here-in-before but for floor mounted AHU of capacity 6043 CFM. | 3 | Each Job | 1,500 ₹1,500 Lowest | 15,000 ₹15,000 |
| 4.00 | All as per Item No. 1.00 here-in-before but for floor mounted AHU of capacity 4738 CFM. | 3 | Each Job | 1,500 ₹1,500 Lowest | 15,000 ₹15,000 |
| 5.00 | All as per item srl no. 1 here in before but for celing suspended AHU of capacity 4200 CFM | 3 | Each Job | 1,500 ₹1,500 Lowest | 15,000 ₹15,000 |
| 6.00 | Material and labour for leakage detection in refrigeration line circuit of scroll chiller, plugging the same, nitrogen pressure testing, vacummizing and testing and commissioning complete all as specified and directed by Engineer -in 0- charge | 12 | Each Ckt | 12,000 ₹12,000 Lowest | 60,000 ₹60,000 |
| 7.00 | Material and labour for leakage detection in refrigeration line circuit of s package type AC plant of capacity 16.5 TR chiller, plugging the same, nitrogen pressure testing, vacummizing and testing and commissioning complete all as specified and directed by Engineer -in-charge. | 2 | Each Job | 2,000 ₹2,000 Lowest | 10,000 ₹10,000 |
| 8.00 | Material and labour for leakage detection in refrigeration line circuit of s package type AC plant of capacity 9 TR chiller, plugging the same, nitrogen pressure testing, vacummizing and testing and commissioning complete all as specified and directed by Engineer -in-charge. | 2 | Each Job | 2,000 ₹2,000 Lowest | 10,000 ₹10,000 |
| 9.00 | Material and labour for leakage detection in refrigeration line circuit of s package type AC plant of capacity 7 TR chiller, plugging the same, nitrogen pressure testing, vacummizing and testing and commissioning complete all as specified and directed by Engineer -in-charge. | 6 | Each Job | 6,000 ₹6,000 Lowest | 30,000 ₹30,000 |
| 10.00 | Material and labour for De-Scaling of 13 TR condenser cells & tubes unit by chemical circulation, rodding with wire brush to remove deposited scale in condenser including replacement of end plate gasket complete all as specified and directed by Engineer -in-charge. | 12 | Each Ckt | 60,000 ₹60,000 Lowest | 96,000 ₹96,000 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
26 Aug 2026, 6:00 pmClosed
CWE (AF) Ambala
HQ CWE (AF) Ambala Ambala Cantt-133001
CWE/AF AMB/SAR-T02/2026-27 REPAIR MAINT OF AIR CONDITIONING AND REFRIGERATION SYSTEM AC PLANT AT AF STN SARSAWA UNDER GE AF SARSAWA
2026_MES_781565_1
CWE/AF AMB/SAR-T02/2026-27
Open Tender
Civil Works
Item Rate
180 days
Sarsawa
For MES enlisted contractor Class D Category c i and for un-enlisted contractor refer NIT
8 documents required · 8 mandatory
₹500
GE (AF) Sarsawa
₹60,000
Yes
9 Sept 2026
29 Jul 2026
28 Aug 2026
29 Jul 2026
26 Aug 2026
13 Aug 2026
29 Jul 2026 - 11 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Periodical servicing/maintenance of floor mounted Air Handling Unit (AHU) of capacity 8338 CFM by carrying following works :-
(i) Removal of air filters (primary & secondary) from filter section, removal of dirt/dust partical by compressed air blower followed by washing under running tap water and refixing at site after complete dry .
(ii) Removal of dirt/dust particals from aluminium fins of cooling coil by soft brushing followed by air blowing and cleaning of cooling coil by forced spray chemically (such as veni clean solution) all as directed by Engineer-in-Charge.
(iii) Cleaning & removing of complete scale from bottom tray and drain pipe of AHUs as directed at site by the Engineer-in-Charge.
(iv) Cleaning of drain pipe from AHUs tray to out side plant room manually as well as any de-scaling solution for draining.
(v) Checking serviceability/tightening of fan motor V-belt, pulley block, fan blades assembly.
(vi) Checking serviceability/tightening of AHU door lache and greasing/oiling. | 3 | Each Job | - | - |
| 2 | All as per Item No. 1.00 here-in-before but for floor mounted AHU of capacity 8342 CFM. | 3 | Each Job | - | - |
| 3 | All as per Item No. 1.00 here-in-before but for floor mounted AHU of capacity 6043 CFM. | 3 | Each Job | - | - |
| 4 | All as per Item No. 1.00 here-in-before but for floor mounted AHU of capacity 4738 CFM. | 3 | Each Job | - | - |
| 5 | All as per item srl no. 1 here in before but for celing suspended AHU of capacity 4200 CFM | 3 | Each Job | - | - |
| 6 | Material and labour for leakage detection in refrigeration line circuit of scroll chiller, plugging the same, nitrogen pressure testing, vacummizing and testing and commissioning complete all as specified and directed by Engineer -in 0- charge | 12 | Each Ckt | - | - |
| 7 | Material and labour for leakage detection in refrigeration line circuit of s package type AC plant of capacity 16.5 TR chiller, plugging the same, nitrogen pressure testing, vacummizing and testing and commissioning complete all as specified and directed by Engineer -in-charge. | 2 | Each Job | - | - |
| 8 | Material and labour for leakage detection in refrigeration line circuit of s package type AC plant of capacity 9 TR chiller, plugging the same, nitrogen pressure testing, vacummizing and testing and commissioning complete all as specified and directed by Engineer -in-charge. | 2 | Each Job | - | - |
| 9 | Material and labour for leakage detection in refrigeration line circuit of s package type AC plant of capacity 7 TR chiller, plugging the same, nitrogen pressure testing, vacummizing and testing and commissioning complete all as specified and directed by Engineer -in-charge. | 6 | Each Job | - | - |
| 10 | Material and labour for De-Scaling of 13 TR condenser cells & tubes unit by chemical circulation, rodding with wire brush to remove deposited scale in condenser including replacement of end plate gasket complete all as specified and directed by Engineer -in-charge. | 12 | Each Ckt | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tender02T.pdf
Tender Documents • 0.50 MB
BOQ_875546.xls
BOQ • 0.64 MB
Revisedpagest02.pdf
PDF • 0.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .