The DGM (CIVIL)
TCMPF Limited ,Aavin illam,Nandanam-35
Removal of Existing Damaged GI MS powder coated roof shed and reroofing with Puff insulated roof system at SMP ware house Marketing godown Ambattur Dairy
2024_TCMPF_488839_1
13241/Engg.2/2024
Open Tender
Civil Works
Lump-sum
30 days
Ambattur
Refer Tender document
7 documents required · 7 mandatory
₹0
₹40,800
Yes
4 Nov 2024
27 Sept 2024
4 Oct 2024
27 Sept 2024
3 Oct 2024
27 Sept 2024
27 Sept 2024 - 3 Oct 2024
Amount
Removing and cutting fallen trees, small plants and weeds, branches etc., complete and the debris remove from site as directed by the Federation officers
Removing damaged GI powder coated MS roofing sheet complete and the removed powder coated sheet from the site and stacked the places shown by the Federation officers
Removing damaged Glass ventilator (North light) complete and the removed material stacked the places shown by the Federation officers
Supplying and fixing in position of MS angle, tubular hollow section, purlin & rafters etc., including cutting, welding and fixing in proper position of approved quality with scaffolding Charges and Pulley arrangements in all floors etc.,complete as directed by the Federation officers and as per standard specifications.The material should get approval from the Federation Engineers .
Supply & fixing in position with 50mm thick PU (Polyurethane) PUF insulated sandwich panel roofing sheet of 0.40 to 0.50 mm thick prepainted Galvalume corrugated of approved make for roofing, cantilevered canopies. The rate including the laps with necessary hanging soffits and cleats with anchor fasteners, "GI", "J" bolts & nuts, screws, bitumen washers etc., complete as directed by the Federation officers and as per standard specification. The material should get approval from the Federation Engineers .
Supply & fixing in position with wired glass fire proof glass 6 mm thick of approved make of roofing,sky light , cantilever canopies.The rate including the laps with necessary "GI" "J" bolts and nuts , Screws,bitumen washers etc., etc complete as directed by the Federation officers and as per standard specification.The material should get approval from the Federation Engineers .
Supplying, fixing & placing in position with GI roofing MS powder coated metal roofing sheets 0.47 mm thick of approved make for roofing, cantilevered canopies. The rate including the laps with necessary "GI", "J" bolts & nuts, screws, bitumen washers etc., complete as directed by the Federation officers and as per standard specification.(JSW/TATA or Equivalent). The material should get approval from the Federation Engineers .
Painting two coats of over old iron surface works with approved quality synthetic enamel paint of approved colour in all floors. The rate is inclusive of all materials, brushes scrabbing the old iron surfaces and scaffolding charges etc., complete complying with standard specification as per the direction of federation officers.
Dismantling brickwall etc., complete and the debris remove from site and dumped/ spread as places shown by the Federation officers
Dismantling RCC slab/floor/pavement etc., and the debris remove from site and dumped/ spread as places shown by the Federation officers
Plastering with Cement Mortar 1:5 (1 Part cement: 5 Parts P- sand) , 20mm thick in all floors including curing ,Scaffolding etc. complete complying with standard specification and as directed by the departmental officers.
UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from theFederation Engineers before use on work.
GST (Note: The tenderer should quote the amount towards Goods and Service tax (GST) in the appropriate columns in terms of percentage (%). If not quoted, it will be considered that the rate quoted is inclusive of GST.)
PEARL ENGINEERS CONSTRUCTION CO-OPERATIVE SOCIETY (BID ID -1154457)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .