Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.6 LAccepted-AOC | ₹44.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹45.8 L+₹1.2 L (2.66%)Rejected-Finance | ₹45.8 L+₹1.2 L (2.66%) | L2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | MULTI TECH CORPORATION L1 | S.ANBU L2 |
|---|---|---|---|---|---|
| 1.00Providing Networking Arrangements at 2D Floor in Panagal Building, Saidapet Estimate Amount Rs.45.05 Lakh | |||||
| 2.00Equipment's | |||||
| 3.00 | 1.0 TR Inverter Split Air conditioner With 3 Star Rating R32 Gas and Cordless Remote Controller-ATKL35 | 1 | No | 37,800 ₹37,800 Lowest | 37,810 ₹37,810 |
| 4.00 | 1.5 TR Inverter Split Air conditioner With 3 Star Rating R32 Gas and Cordless Remote Controller-ATKL50U/DTKL50U/FTKL50U | 1 | No | 44,800 ₹44,800 Lowest | 44,810 ₹44,810 |
| 5.00 | 1.5 TR Inverter Cassette Air conditioner With 3 Star Rating R32 Gas and Cordless Remote Controller- FCVFQ50AV16 / RZVFQ50AV16 | 5 | Nos | 72,380 ₹3,61,900 Lowest | 72,390 ₹3,61,950 |
| 6.00 | 2.5 TR Inverter Cassette Air conditioner With 3 Star Rating R32 Gas and Cordless Remote Controller- FCVFQ90AV16 / RZVFQ90AV16 | 4 | Nos | 1,14,142 ₹4,56,568 Lowest | 1,14,152 ₹4,56,608 |
| 7.00 | 3.0 TR Inverter Cassette Air conditioner With 3 Star Rating R32 Gas and Cordless Remote Controller- FCVFQ100AV16 / RZVFQ100AV16 | 1 | No | 1,16,613 ₹1,16,613 Lowest | 1,16,623 ₹1,16,623 |
| 8.00Ancillary Works | |||||
| 9.00 | Suction Line & Liquid Line - Cassette & split | 104 | Rmt | 1,820 ₹1,89,280 Lowest | 1,830 ₹1,90,320 |
| 10.00 | Protective tape covering the refrigerant pipes running between the indoor | 104 | Rmt | 126 ₹13,104 Lowest | 136 ₹14,144 |
Tender Value
₹45.0 L
EMD Value
₹46,000
Closing Date
25 Feb 2026, 3:00 pmClosed
The Project Director, DRDA, Kancheepuram
O/o The Project Director, DRDA, Kancheepuram
Providing Networking Arrangements at 2D Floor in Panagal Building, Saidapet
2026_RDTN_660325_1
DIPR/1155/Tender/2026, Dt.18.02.2026
Open Tender
Civil Works - Buildings
Item Wise
60 days
DRDA, Kancheepuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹46,000
Yes
7 Mar 2026
18 Feb 2026
25 Feb 2026
18 Feb 2026
25 Feb 2026
18 Feb 2026
Providing Networking Arrangements at 2D Floor in Panagal Building, Saidapet Estimate Amount Rs.45.05 Lakh
Equipment's
1.0 TR Inverter Split Air conditioner With 3 Star Rating R32 Gas and Cordless Remote Controller-ATKL35
1.5 TR Inverter Split Air conditioner With 3 Star Rating R32 Gas and Cordless Remote Controller-ATKL50U/DTKL50U/FTKL50U
1.5 TR Inverter Cassette Air conditioner With 3 Star Rating R32 Gas and Cordless Remote Controller- FCVFQ50AV16 / RZVFQ50AV16
2.5 TR Inverter Cassette Air conditioner With 3 Star Rating R32 Gas and Cordless Remote Controller- FCVFQ90AV16 / RZVFQ90AV16
3.0 TR Inverter Cassette Air conditioner With 3 Star Rating R32 Gas and Cordless Remote Controller- FCVFQ100AV16 / RZVFQ100AV16
Ancillary Works
Suction Line & Liquid Line - Cassette & split
Protective tape covering the refrigerant pipes running between the indoor
Electrical Cabling 4 core 2.5 sq.mm Electrical Cabling between indoor and outdoor
3/4" Electrical Conduit
Power cable 4 core 2.5sqmm
Drain Pipe PVC Drain Pipes - 1" 6kg Per Cm2
Nitrile rubber Insulation for PVC Drain piping - 6mm thick
Supports Hi tech supports for the refrigerant pipes and drain pipes
Anti-Vibration Mountings Pads
Readymade stand - ODU Units
Readymade stand - ODU Units Heavy
G.I Perforated Tray 200*75 mm
M.S Channel works- ODU units
Labour Charges Cassette Installation
Hiwall installation
Pressure Testing, Gas Charging and commissioning of the unit and refrigerant pipes
Copper laying charges
Cable Tray laying charges
Night Work Activities
NETWORKING Supply I/O - Cat 6 UTP Jack with Strain relief and bend limiting boot - data
Supply I/O - Cat 6 UTP Jack with Strain relief and bend limiting boot - voice
Supply Faceplate - 2-port British Style Shuttered faceplate
Supply Faceplate - 4-port British Style Shuttered faceplate
Supply Cables - 4-pair, Cat6 UTP Cable, roll of 305m box data
Supply Cables - 4-pair, Cat6 UTP Cable, roll of 305m box voice
Supply Rack - 15U rack, casters and 6 socket 5/15 amps
Supply of Power Strip.
Supply Jack panel - Cat6 24-port loaded, Straight Jack Panel, 1U- (data)
Supply Jack panel - Cat6 24-port loaded, Straight Jack Panel, 1U- (voice)
Supply Cat6 SL Series Patch Cords - 7 Feet-Yellow
Supply Cat6 SL Series Patch Cords - 7 Feet-Yellow
Supply of PVC 32mm channel.
Supply of PVC 25mm channel.
Supply of CABLE Tie 250mm
Supply of CABLE Tie 200mm
Supply of CABLE Tie 100mm
Installation of Labels & Ferrules - Cables, Panels, Face plates, Patch cord & Rack Old Cable Removing Relaying
Supply 350mm x 350mm wide x 50mm ht
Supply 250mm x 250mm wide x 50mm ht
Supply 150mm x 150mm wide x 50mm ht
Supply 24-port Gigabit switch DGS 1210-28 D Link
Supply TPLINK EAP245 with mount kit
Supply TL SG2210MP PEO switch
Supply 100 Pair rackmount MDF with Modules
Supply 50Pair indoor raiser cable.
Supply of Jack Panel for voice cable termination (RJ11)-(50- Port)
Supply Cat6 SL Series Patch Cords - 7 Feet-Yellow
Supply 100Single pair Jumper cable.
EARTHING Supply & Installation of Maintenance free chemical Earth with 40mm dia hot dipped Copper 2.6 mm thk, 3.0 mtrs deep, complete with all accessories such as chemical compound, earthing link, chamber etc. The earth resistance shall be not more than 2.0 Ohms.
Supply & Laying of 8SWG copper wire
Supply, Laying & Termination of PVC insulated 2Runs of Single core 10sqmm Green colour copper cable with suitable size PVC conduit for dedicated earthing with all fixing accessories.
Supply, Installation, Testing, Commissioning of Earth Bus of following sizes inside powder coated MS fabricated box to be mounted on insulator as follows:
25mmx3mm x 250 mm Long Copper Bus
25mmx6mm x 250 mm Long Copper Bus
MISCELLENOUS Supply & Installation of 1.0 KVA Invertor, 1Phase input & 1 Phase output with overload, short circuit protection and 30.0 Minutes SMF Battery back up with MS battery rack and all accessories as required.
TEMPORARY POWER - FOR CONSTRUCTION Arranging temporary Lighting & Power for all agencies to work including suitable protection through MCBs/ELCBs/MCCBs & wiring /cabling. power shall be provided to all agencies during execution with required no. of light fixtures as per the site condition & required Industrial Socket outlets as per the site condition till commissioning stage.
REMOVING OF EXISTING WORK Existing of all electricals pipe & switch socket , wiring and existing DB'S Metal box and others
UPS Supply and installation of APC Make 10KVA UPS with Open metal Rack
Supply and installation of 12V-65AH EXIDE make SMF Batteries will provide 1hr backup
WIRING FOR POWER OUTLETS Supply & Laying flexible FRLS Copper Cable for UPS Power /Raw Power sockets through suitable size PVC conduit laid in Surface/concealed/in side partition as per the site condition (White colour cable for UPS and Black colour cable for Raw power)
3 C/R x 2.5Sqmm Copper cable ( For 5A Sockets UPS )
3 C/R x 4.0Sqmm Copper cable (For 15A Sockets)
3 C/R x 6 Sqmm Copper cable
GST Amount for providing Service to Government Contract Works for the above Construction Work. { GST Amount is the Total GST Amount for overall quoted amount Construction above this row in column "BB" for all works in this package} (Refer Clause 13.2 & 13.3 of Section 2 of Instruction to Bidders (ITB) of SBD)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.09 MB
Technical04.pdf
Tender Documents • 0.84 MB
BOQ_792257.xls
BOQ • 0.43 MB
Price04.pdf
Additional Documents • 0.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .