Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹33.3 LAccepted-AOC | L 1 | Accepted-AOC BEING L1 BID
AND EAS
ACCEPTED BY
TC | |
| 2 | L 2₹35.9 L+₹1.9 L (5.64%)Rejected-Finance | L 2 | Rejected-Finance Being other
than L1 | |
| 3 | L 3₹37.5 L+₹3.5 L (10.4%)Rejected-Finance 145 SAINIK NAGAR RAIBARELLI ROAD TELIBAGH LUCKNOW | L 3 | Rejected-Finance Being other
than L1 | |
| 4 | L 4₹38.2 L+₹4.2 L (12.4%)Rejected-Finance | L 4 | Rejected-Finance Being other
than L1 |
Tender Value
₹48.0 L
EMD Value
₹96,020
Closing Date
27 Mar 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (EAST) LUCKNOW
GE (EAST) LUCKNOW PIN 226002
SPL REPAIR TO BLDG NO P27 URINAL BLOCK ADM BN AND SPL REPAIR TO BLDG NO T51 T52 AND T53 OF OTC AMC C AND C AND OTHER MINOR WORK UNDER GE EAST LUCKNOW
2025_MES_699290_1
GE/E/LKO/T-69 OF 2024-25
Open Tender
Civil Works
Item Rate
270 days
GE (EAST) LUCKNOW
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE (EAST) LUCKNOW
₹96,020
Yes
15 Jul 2025
27 Feb 2025
3 Apr 2025
27 Feb 2025
27 Mar 2025
13 Mar 2025
Amount
Demolition of cement concrete (unreinforced ) in floors and pavings n. exc 15cm thickness (above or below GL) complete all as specified and directed
Dismantling floor, hearth or wall tiles, including cement mortar, removing serviceable tiles from site & rubbish off the premises, complete all as specified and directed.
Taking down cement or cement lime plaster or stone / brick wall, ceiling including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
Taking down chowkhat or frames with shutter (without taking off shutter from the frame ) area n. exc 1.5 Sqm each complete with hold fasts etc complete all as specified and directed.
Taking down chowkhat or frames with shutter (without taking off shutter from the frame ) area exc 1.5 Sqm but n. exc 4.0 Sqm each complete with hold fasts etc complete all as specified and directed.
M&L for brick work with flyash old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed.
M&L for 10mm thick rendering in cement mortar in CM (1:4) on ceiling finished even and smooth without using extra cement, complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:4) mixed with water proofing compound @ 3 % by weight of cement on other than fair faces of brick / stone masonary surfaces, finished even and smooth without using extra cement, complete all as specified and directed (WPC measured and paid separately)
M&L for rendering in cement mortar (1:6), 15mm thick on other than fair faces of brick work / stone masonary surfaces finished even and smooth without using extra cement, complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.11 Sqm but not exc 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bedding in cement mortar 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 7 to 8mm thick in vertcial surfaces of size exceeding 0.11 Sqm but not excceding 0.18 Sqm set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick screed plaster in cement mortar 1:4 complete all as specified and directed.
S&F pressed steel frames of size 105 x 60mm for doors with one or more rabtes including necessary fixing lugs, hinges, lock strike plate, etc ocmplete all as specified and directed.
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commerical type on both sides complete all as specified and directed.
S&F 3mm thick glass, ordinary quality, 3mm thick fixed with oil putty size of glass not exc 0.50 sqm in each pane, complete all as specified and directed.
S&F MS butt hinges, medium weight, cold rolled, ISI marked of size 100mm, complete all as specified and directed.
S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F 140mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and directed.
S&F 300mm long alumimium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolt of extruded section or cast aluminium alloy complete all as specified and directed.
M&L for cutting holes in brick walls (N exc half brick) for inserting hold fasts and making good dismantled portion in PCC 1:2:4 (20mm aggregate) and cement mortar 1:3 complete all as specified and directed.
S&F mild steel work such as hold fasts, hooks, clamps etc and similar work conforming to Fe 290 , Gde -165 complete all as specified and directed.
Taking down old unserviceable 15mm GI tubing, fittings and connections and removing from site or keeping aside for refixing complete all as specified and directed.
Taking down old unserviceable 20mm GI tubing, fittings and connections and removing from site or keeping aside for refixing complete all as specified and directed.
S&F 15mm GI water tubing( Concealed type), medium grade, galvanised with all fittings ( and fixed to walls, ceiling or laid in floors/ trenches complete all as specified and directed.
S&F 20mm GI water tubing, medium grade, galvanised with all fittings ( and fixed to walls, ceiling or laid in floors/ trenches complete all as specified and directed.
Refixing old 15mm GI tubing (Concealed type) galvanised with new fittings and fixed to walls, ceiling or laid in floors, trenches including necessary cleaning, cutting, screwing complete all as specified and directed.
Refixing old 20mm GI tubing galvanised with new fittings and fixed to walls, ceiling or laid in floors, trenches including necessary cleaning, cutting, screwing complete all as specified and directed.
S&F in repair tubular towel rail, chromium plated brass 20mm dia 'D" type 60cm long between flanges complete all as specified and directed.
S&F in repair PVC connection, heavy duty 15mm bore, 45cm long with 2 Nos PTMT nuts of approved quality complete all as specified and directed.
S&F in repair angle valves 15mm bore , cast copper alloy chromium plated with long sunk and cap (Concealed type), screwed down high pressure screwed both ends for iron pipe or for unions and fixed etc complete all as specified and directed.
Supply only liquid water proofing compound of approved quality and make confirming to IS complete all as specified and directed.
Taking down 100mm / 75mm dia AC rain water pipe (any size or pattern ) including all fitting, heads, shoes, bends and removing from sites complete all as specified and directed. (Measured over all as fixed along the centre line over the fittings and accessories)
S&F 110mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall or laid in floors / trenches with & including existing / new PVC clamps complete all as specified and directed.
S&F 75mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall or laid in floors / trenches with & including existing / new PVC clamps complete all as specified and directed.
S&F 110mm PVC (SWR) junction single, (Single T) equal or unequal with access door with cement joint complete all as specified and directed.
S&F 75mm PVC (SWR) junction single, (Single T) equal or unequal with access door with cement joint complete all as specified and directed.
S&F 110mm bore PVC (SWR) bend / shoe of any radius with access door, complete all as specified and directed.
S&F 75mm bore PVC (SWR) bend / shoe of any radius with access door, complete all as specified and directed.
S&F in repairs PVC (SWR) floor trap 75mm, plain with grating including jointing with solvent cement complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate, 50mm thick as in plinth protection finished fair & even laid in alternative bays n. exc 2M in length and joints filled with bitumen mastic 1:3 complete all as specified and directed.
S&F in repair new rigid PVC waste pipe of approved quality 32mm bore, 75mm long with one end socketed fixed to waste coupling including one PVC reducer 32mm complete all as specified and directed.
M&L for preparation of new steel and iron surfaces of any description over 10CM width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of new or previously untreated wood and wood based surfaces of any description not otherwise descriped over 10cm width girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L for three coats of white wash on walls including preparation of newly/ old plastered surfaces complete all as specified and directed.
M & L for three coats of white wash on ceiling including preparation of newly/ old plastered surfaces complete all as specified and directed.
M&L for preparation of old/ newly plastered surfaces and applying two coats of weather proof acrylic emulsion paint over a coat of 1mm thcik wall care putty & including a coat of emulsion wall primer all as per manufacture's instructions & as directed by Engr-in-Charge.
S&F in repair soap dish, any type fixed to plugs with chromium plated brass screws completed all as specified and directed.
S&F for steel windows with side hung shutters including projection type hinges with steel handle, ans steel peg stay complete with glazing bars, dovetailed and welded,complete all as specified and directed.
S&F for steel windows with side hung shutters including projection type hinges with steel handle, and steel peg stay complete without glazing bars, dovetailed and welded, complete all as specified and directed.
M&L for 16 to 18mm thick granite ( of any type ) work (table rubbed and polished ) in steps, jambs, pillars, window -cills, cooking platforms and like pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including rounding of edge laid over 15mm thick screed bed in CM (1:6) including rounding of edge of stone slabs one edge complete all as specified and directed.
Dismantling / taking down existing unserviceable RCC/PVC and S&F 1000 Ltr capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
S&F ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe of 20mm dia and fixed (minimum weight 210 gms).complete all as specified and directed.
S&F in repairs Vitreous China urinals, half stall type (flat back), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including spreader, 60mm long brass screws, pointing around urinal back in cement; fixing with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed.
S&F in repair 20mm bore Gun Metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe fixed complete all as specified and directed.
Taking down existing treatment any type/any thickness on roof including taking down/removing the backing bed concrete if any and dispose off at a distance exc 100m as directed etc complete all as specified and directed.
M&L for brushing neat cement slurry with 3.0 Kg./Sqm over roof slab complete all as specified and directed.
M&L for PCC 1:2:4, type B1 using 20 mm graded stone aggregate as in roof padding/ roof kerbs / benching / coved fillets etc rounded or chamfered on edges, complete all as specified and directed.
M/L for roof/sunkn treatment with polymeric water proofing mem breane with certain specification given below as under complete all as specified & directed (a) M&L plastering 10mm in CM 1:4 using 100% course sand on roof including WPC @ 3% by weight of cement. (b) Applying a coat of bitumenous primer @ 0.50 LTRs /Sqm and allow to dry (c) Applying a coat of hot blown bitumen grade 85/25 @ 1.20 Kg/Sqm. (d) Supply and laying APP based polymeric water proofing membrane, weight not less than 3.00 kg/sqm and and minimum 3 mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) sealed the side laps with spread temper (e) applying a tack coat of hot blown bitumen grade 85/25 @ 1.20 Kg/Sqm.
S&F in repair wash hand basins vitreous china, coloured flat back size 550 x 400mm fixed including bracket complete all as specified and directed.
S&F in repairs 15mm bore pillars taps fency type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe fixed complete all as specified and directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of apertature 1.40mm and fixed with tinned tacks or stainless steel wire staples complete all as specified and directed.
Taking down shutters of any description exc 1.00 sqm but not exc 2.00 Sqm each complete all as specified and directed.
Taking down shutters of any description exc 1.00 Sqm but n. exc 2.00 Sqm and easing, ajusting and also refixing builders hardware as required and renewal of unserviceable screws and refixing in the same opening complete all as specified and directed.
Dismantling plain asbestos cement (corrugated, semicorrugated etc ) sheets in roof coverings complete all as specified and directed.
Demolition of brick work or stone masonary built in cement mortar etc complete all as specified and directed.
S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20mm graded stone for embedding of hold fast etc complete all as specified and directed.
S&F hold fasts; supports or stays for rainwater, knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe 290 or Fe 310-0 complete all as specified and directed.
Dismantling of old ceiling boards any type and any thickness including cover fillets/ aluminum snap grid complete all as specified and directed.
M&L for false ceiling with 4 mm thick E-board white prelaminated set embossed reinforced designer ceiling board of approved texure fixed with GI imposed grid frame work of size not more than 600 x 600 mm having 24 mm wide T- section, runner made of 0.33 mm GI sheet and angle made of 0.45 mm GI sheet, suspended with 2 mm dia GI wire including complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in floors complete all as specified and directed.
M&L for 30 mm thick with one side decorative laminated flush shutters, solid core construction, with block board 3 core and plywood face panels, commercial type on both sides complete all as specified and directed. by Engr -in-Charge.
S&F 35 mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
M & L for brick work with fly ash bricks, straight or curved on plan exc 6M mean radius, old size brick built in cement mortar 1:6 complete all as specified and as directed.
S & F powder coated aluminum Window sliding type three track with glazed and gauzed shutter (incl stainless steel wire cloth 0.36 mm nominal dia and 1.40 mm apreture and 3.8 mm thick plain glass) on wheel consisting frame of size 100 x 44 (sliding shutter consist of suitable size of section as specified and directed) with locking arrangement as approved fixed with rubber gas ket and aluminum beading etc including necessary cutting hole in wall fixed complete all as specified and directed..(Note-glazed shutters glass thickness not less than 3.8 MM and wiremess shutter with SS wiremesh as approved by GE is also included. No payment will be made separately)
S&F aluminum Anodised grills of aperature 75 mm and fixed in frame of window and ventilator including necessary fixing arrangement etc complete all as specified and directed.
M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. fixed with L- type or J- type or cranked hook bolts complete all as specified and directed.
M&L for Asbestos cement one piece plain angular ridge 6mm thick fixed with L- type or J- type or cranked hook bolts complete all as specified and directed.
M&L for machine cut kota sotne slab, 20-25mm thick over and including 15mm thick screed bedding in cement mortar 1:6 as in floors, laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for machine cut kota sotne slab in skirting / steps / risers of reqd size, 20 to 25mm thick & including 15mm thick screed bedding in cement mortar 1:4 as in floors, laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
S&F 150mm floor door stopper of brass body and tongue, with hard drawn steel spring complete all as specified and directed.
M&L for preparation of old / newly plastered surface of wall and apply two coats of oil bound distemper over a coat of 1mm thick wall putty, complete all as specified and directed.
S&F in repair drapery rods, coloured, standrad quality, PVC coated not less than 25mm dia with heads at both ends and middle support/brackets, rings etc. complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 Cum, getting out, and removing surplus soil to a distance n exc 50m and making good surface in soft/loose soil, complete all as specified and directed.
M&L for cement concrete type C-2 1:3:6 using 40 mm graded stone aggregate in filling foundation and mass concrete, complete all as specified and directed.
Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and as directed.
S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F mild steel angles/flat iron as in fencing post and struts including embeeded in concrete and screwing etc including securing bolts, cutting tops to shape as directed, drilling holes notching for wire, etc complete all as spficied Fe 290 Gde E-165, complete all as specified and directed.
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete all as specified and directed.
Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box ( Mesurement of Seprate items of terminal box) and making good to the disturbed surfaces to match the existing complete all as specified and directed.
All as per serial item No 92 here-in-before but one 3 pin, 06 Amp socket outlet point on independent board controlled by one, one way switch 06 Amp.complete all as specified and directed.
All as per serial item No 92 here-in-before but one 3 pin, 06 Amp socket outlet point on same board controlled by one, one way switch 06 Amp.complete all as specified and directed.
All as per Serial Item No 92 here-in-before but point wiring with 2.5 Sq mm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 16 Amp socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
S&F in replacement Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed
S&F in replacement Switch Modular 16A single pole, one way, 1 module complete all as specified and as directed
S&F in replacement Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed
S&F in replacement Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed
S&F in replacement Modular White cover plate with frame,8 module complete all as specified and as directed
S&F in replacement Modular White cover plate with frame,6 module complete all as specified and as directed
S&F in replacement Modular White cover plate with frame,4 module complete all as specified and as directed
S&F in replacement Modular White cover plate with frame,3 module complete all as specified and as directed
S&F in replacement Modular White cover plate with frame,2 module complete all as specified and as directed
S&F in replacement Modular Metal flush box 8 module complete all as specified and as directed
S&F in replacement Modular Metal flush box 6 module complete all as specified and as directed
S&F in replacement Modular Metal flush box 4 module complete all as specified and as directed
S&F in replacement Modular Metal flush box 3 module complete all as specified and as directed
Supply and fix fan step regulator, 120W 2 module complete all as specified and as directed
S&F in replacement Modular Metal flush box 2 module complete all as specified and as directed
Supply and fix LED tube light fittings 1200 mm,20 W higher energy saving decorative ultra slim square profile LED lighting fixture with extruded aluminum housing enviromental friendly, energy efficient complete all as specified and directed.
Supply and fix ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified & directed.
Material and labour in replacement for sub main wiring with 6 Sq mm nominal cross sectional area,2 run single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 6 Sq mm nominal cross sectional area, single core r runs ( neutral and earth colour code wire), 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.Note : 2 runs of 06 sqmm, 1 run of 6 sqmm earth and nutral conductor and 1 run of PVC conduit shall be measured as one unit length for
Material and labour in replacement for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.Note : 2 runs of 4 sqmm, 1 run of 4 sqmm earth and nutral conductor and 1 run of PVC conduit shall be measured as one unit length for
Supply and fix in replacement of AC modular box with modular 20 Amp MCB SPN suitable for Geyser and AC complete with and including MCB, SP, AC, 240 volt of 20 Amp, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply and fix in replacement of sheet metal enclosure distribution board, double door, single pole and neutral, AC, 240 volt, 12 way, with 200 Amp rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply and fix in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN),double door, AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed and comprising of the following:- (a) MCCB, 125 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. (b) MCB, SP, AC, 240 volt of 06 to 32 Amp, "C" curve, 10 KA breaking capacity - 12 Nos.
Supply and fix in replacement of MCB, SP, AC, 240 volt of 06 to 40 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supply and fix in replacement of MCB, DP, AC, 240 volt of 32 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed.
Taking down carefully ceiling fan of any sweep complete with all accessories, dismantling blades and deposit in safe custody of AGE E/M Yard-II for BER procedure complete all as specified & directed.
Supply and fixing of stationery storage type electric BEE 5 star rated Hot Water Geyser of capacity 25 Ltr to operate on 230 volt AC, vertical type, working pressure min 0.8 Mpa with ,multi function safety valve and PUF insulation including 4 nos full threaded fastner of size 100 x 10 mm with 2 Nos washer, water connection complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) with remote oprated complete all as specified and directed. by Engr-in-Charge
S&F exhaust fans, plastic body, ac, single phase, 230/240 v of size 250 mm sweep with louver and making connection with twisted copper flexible wire 23/0.076mm complete all as specified and directed.
Supply and fixing in replacement LED Bldg security light fitting LED 45 watt with SPD, PF not less or equal 0.9,epoxy coated cover sheet aluminium housing with heat resistant toughtened glass & IP 66 incl with bracket, clamps, nuts, bolts protection complete all as specified and directed.
Cutting walls any type, making holes for fixing of exhaust fan of any size or sweep and making good surface with fine plastering, finishing and colouring with existing colour matching complete all as specified and directed
Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core including taking out old cable complete all as specified and directed.
Excavation in trenches soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of pipes/cables etc getting out and bottom surface to required gradient complete all as directed & specified
M & L Returning filling in including spreading leveling watering and well ramming in layers each not exceeding 25 cm thickness complete all as specified and as directed
M & L Removal of surplus spoil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed
Supplying, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cable for under ground cable complete all as specified & directed. i.e 18 cm punned down thick shall be considerd for mesurement) complete all as specified and directed.
M & L for Old size sub class 'B' bricks,laid flat in trenches over the cable with length of brick perpendicular to the direction of the cable , adjacent/abutting each other complete all as specified and directed.
Supply and fix in replacement rectangle wall light LED integrated fittings MS wit polycarbonate diffuser Chrome colour dimension size 300x65x130 mm, 1000 lmn ,10 watt wall mounted higher energy saving decorative ultra enviromental friendly, energy efficient complete all as specified and directed.
Supply and fix in replacement of MCB, SPN, AC, 240 volt of 40 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supply and fixing in replacement LED Bldg security light fitting LED 35 watt with SPD, PF not less or equal 0.9,epoxy coated cover sheet aluminium housing with heat resistant toughtened glass & IP 66 incl with bracket, clamps, nuts, bolts protection complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4.0 core including taking out old cable complete all as specified and directed.
Supply and fix GI pipe 80 MM medium grade in wall incl cutting complete and making good surface complete all as specified and directed.
ANIL CONSTRUCTION (BID ID -3267323)
M/S KAUSHIK CONSTRUCTION (BID ID -3267054)
m/s raghubar dayal (BID ID -3267368)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .