Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC | ₹30.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹31.7 L+₹1.0 L (3.37%)Rejected-Finance R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | ₹31.7 L+₹1.0 L (3.37%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹33.7 L+₹3.0 L (9.70%)Rejected-Finance | ₹33.7 L+₹3.0 L (9.70%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹34.7 L+₹4.0 L (13.1%)Rejected-Finance | ₹34.7 L+₹4.0 L (13.1%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹36.4 L+₹5.7 L (18.7%)Rejected-Finance | ₹36.4 L+₹5.7 L (18.7%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
26 Mar 2024, 6:00 pmClosed
GE SOUTH AKHNOOR
GE SOUTH AKHNOOR
REPAIR TO PERIMETER LIGHTS, STREET LIGHTS, HIGH MAST LIGHT INCL REPAIR OF DG SETS, PANEL AT RAKHMUTHI DG SETS, PANEL AT RAKHMUTHI UNDER GE (S) AKHNOOR.
2024_MES_645333_1
GES/AKH-58/2023-24
Open Tender
Civil Works
Item Rate
180 days
RAKMUTHI
MES EN-LISTED CONTRACTOR WITH CLASS D AND ABOVE WITH CATEGORY b(i)
9 documents required · 9 mandatory
₹500
GE SOUTH AKHNOOR
₹70,000
18 Jun 2024
6 Mar 2024
3 Apr 2024
6 Mar 2024
26 Mar 2024
20 Mar 2024
Amount
Dismantling and taking down defective high mast light fittings with complete assembly by engaging suitable heavy duty crane/ Hydra machine from pole upto 20 mtr height using electrically operated winch, repairing and refixing after replacing all unserviceable parts including internal wiring complete all as specified and directed by Engineer-in-Charge. Note : (a) Light fittings shall be measured and paid for separately. (b) Spares such as steel wire, winch motor, cable etc shall be measured and paid for separately. (c) The entire work shall be carried out by well experienced professionals who has already carried out the high mast poles dismantling /repair works and similar works. (d) Cost of Minor fittings/fixtures such as screws, bolt/nuts, grease etc shall provided by the contractor without any extra cost to the Govt to make functional lights and nothing shall be admissible on this ground.
Supply only stainless steel rope twisted of size 10 mm dia with necessary connections proper binding on both sides from bottom drum to high mast top connection hook , complete all as specified and directed by Engineer-in-Charge.
Supply only fractional 1.5 HP motor 415 volts suitable for electrically operated high mast light, complete all as specified and directed by Engineer-in-Charge.
Supply only PVC insulated, PVC sheathed multistranded copper conductor cable of size 4.00 sqmm 4 core , complete all as specified and directed by Engineer-in-Charge.
Supply only LED Flood light, powder coated pressure die cast with aluminium housing & frame with heat resistant toughened clear glass fixed with SS screw. / Anti Dust Exposed Lens,sturdiness and embossed brand name/logo name of manufacturer on fixture. The fixture should have a minimum system efficacy of ≥ 125LPW and a minimum system lumen output of 18000 lumens and maximum system wattage of 150 Watts.The fixture shall have a CRI of minimum 70. The fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP66 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK >=07.The fixture driver should have an operating voltage range of 120-277 V, surge protection of internal 4KV and extral surge protection of10KV, PF >0.95 , THD<10%. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Make : Havells Model No Jeta Iris and cat part No . JETAIRISFLS150WLED757P2AV2WBLTG or Crompton Model No PLUTO NEO and cat part No LFLN-150-CDL/60-HPM or Equivalent makes. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
Supply only Integral LED aviation light fittings Integral LED aviation light comprising of aluminium housing with polycarbonate. enclosure Make : Bajaj Cat Part No BGAV 302 LED or equivalent in Crompton/ Havells/Philips
Disconnecting and taking down the existing perimeter light fittings from poles of any type or any make for cleaning by removing the dusts, insects from the inside of compartment, repair/replacement of unsv spares and re- fixing the same complete all on the directed by Engr-in-Charge. Note - Spare parts will be measured and paid for seperately.
Supply only electronic LED driver for LED light fittings, capacity 45/ 50 Watt, 50Hz, complete all as specified and directed by Engineer-In-Charge. Make: Havells/ Crompton Greaves/ Bajaj
Supply only electronic LED driver for LED light fittings, capacity 60/90 Watt, 50Hz, complete all as specified and directed by Engineer-In-Charge. Make: Havells/ Crompton Greaves/ Bajaj
S&F of high-quality integrated LED Street Light with a minimum system lumen of 4950 Lm and system wattage not exceeding 45W with a nominal efficiency 110 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens with Toughned Glass having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK07 to with stand extreme environments with PF > 0.95. Lifetime of 50K hours @L70.The Ingress protection should be minimum IP 66 with an IK rating of 07. The Luminaire should have 4KV internal 10KV external surge protection in the Luminaire.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection including House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified, complete all as specified. Make : Havells model No ENDURA SUNDOWN TG , Cat Part No ENDURASUNDOWNSL45WLED765PASYBOTG or Crompton model No RAPTOR PRO - I , Cat Part No CRP-409-45-57-SL-LM-NSR or Equivalent makes . Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
S&F of high-quality integrated LED Street Light with a minimum system lumen of 6600 Lm and system wattage not exceeding 60W with a nominal efficiency 110 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens with Toughned Glass having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK07 to with stand extreme environments with PF > 0.95. Lifetime of 50K hours @L70.The Ingress protection should be minimum IP 66 with an IK rating of 07. The Luminaire should have 4KV internal 10KV external surge protection in the Luminaire.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection including House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified, complete all as specified. Make : Havells model No ENDURA SUNDOWN TG , Cat Part No ENDURASUNDOWNSL60WLED765PASYBOTG or Crompton model No RAPTOR PRO - I , Cat Part No CRP-409-60-57-SL-GL-NSG or Equivalent makes. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
Supply and fixing in repalcement of bracket made out of GI pipe 1.5 Mtr long, 40 mm dia light grade bent to shape as directed including clamps made out of 40 mm x 6 mm flat for fixing bracket suitable for PCC/steel poles including nuts and bolts, washers and other connected items of required size including painting with one coat of aluminium paint over a coat of red oxide/primer all as specified and as directed.
Disconnecting and taking down the existing unserviceable post top lantern/ gate/ garden light fittings from gates/ poles of any type or any make for cleaning by removing the dusts, insects from the inside of compartment, repair/replacement of unsv spares and re- fixing the same complete all on the directed by Engr-in-Charge. Note - (a) Spare parts will be measured and paid for seperately. (b) Necessary dismantling and new PCC work /touch up work if required to make existing surface as existing etc shall deemed to be included in the quoted rates.
S&F in replacement of IP65 Rated LED Bollard of 10 W with robust design and efficient light distribution including grouting (Foundation) in M-15 Nominal mix PCC type B-1 using 20mm graded crushed stone aggregate 30CMx30CMx30CM and making connetion, complete all as specified and directed by Engineer-In-Charge. Make: Crompton cat part No- LBLTW-10-WW or Equivalent Makes in Philips/Wipro
S&F in replacement of LED Post Top 25W with a system lumen output of 1625 lumens and a minimum system efficacy of 70 lm/W. The luminaire should have a color temperature of 3000K to 5700K and CRI > 70. The luminaire shall meet IP65 & IK07 protection with THD < 10% and PF > 0.95. The luminaire shall have Cast aluminium spigot housing with Opal acrylic diffuser. The total power consumption should not exceed 25W (including driver). Make: Bajaj cat part No BGCTN 25W LED WW or Equivalent Makes in Havells/Crompton. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory
Supply only gate light LED post top 15 watt , new generation, energy saving long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs Ruby clear suitable for mounting on existing Brick pillar gates/ poles on existing pipe of 40/50 mm dia all as directed. Make : Havells Cat No RUBYMINIPT15WLED757PSYMTOPC or equivalent in Bajaj/Crompton
Supply only GI pipe light grade of size 40 mm dia of any height mounted on PCC fdn at existing position all as directed by Engr-in-Charge Note: (PCC measured and paid separately)
Supply only GI pipe light grade of size 50 mm dia of any height mounted on PCC fdn at existing position all as directed by Engr-in-Charge Note: (PCC measured and paid separately)
Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16.0 Sqmm, 4.0-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 6.0 Sqmm, 2.0-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 10.0 Sqmm, 2.0-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge.
Excavation in trenches in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable,erection of poles, stays, pipes etc and not exceeding 10sqm on plan and getting out all as directed.
Excavation in trenches, not exceeding 1.50 mtr wide and exceeding 1.50mtr but not exceeding 3.0mtrs in depth, not exceeding 10 Sqm on plan and getting out, in any type of soil, for laying electric cables or foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm all as specified.
Removal of excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above in starting point.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness shall be measured.
Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed by Engineer-In-Charge.
Replacement of old cracked/ damaged, concrete poles with new pre-stressed concrete pole, 9.0 metres long, cross section 102mmx172mm at top and 102mmx279mm at bottom, class 10, including painting strips in black and white colour, 300mm thick, upto 1.50mtr height, from top of PCC coping with synthetic enamel paint after preparing the surface, complete all as specified and as directed by Engineer-In-Charge. Note: Excavation, earth work and concrete in foundation shall be measured and paid separately under respective items of BOQ.
Taking out existing broken/unserviceable stay assembly and supply and fixing new stay assembly complete with accessories as shown in electrical plate No 1 using GI stay rod 16 mm dia, stay wire 7/4 mm stranded galvanised including mild steel stay plate 230 mm x 230 mm x 6 mm, galvanised steel 14 mm dia 400 mm long stay bow and GI nuts, washers, loop type insulator vitreous porcelain white, brown or green of small size with overall dimensions 65 mm x 90 mm clearance of hole 16 mm complete all as specified and shown in electrical plate No. 1 of SSR part –I. (Note: Excavation and concrete work etc will be measured and paid separately)
Material and labour for Plain cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregates ) as in foundation filling of pole etc complete all specified and directed.
Material and labour for Plain cement concrete (1:3:6 ) type C2 (using 40mm stone aggregate) as in foundation and mass concrete for stay assembly complete all as directed
Material and labour for Plain cement concrete (1:2:4 ) type B-1 (using 20 mm graded stone aggregate) for coping of poles including necessary formwork and finished surfaces complete all as directed
Replacement of PVC junction box of size 140MMx140MMx95MM mounted on GI pipe with MS clamp made out of 40 mm x 6 mm flat for fixing box on pole/wall including terminal point mounted on epoxy insulator for cable connection with 01 No MCB SP 10 amps complete all as directed. Make : Sintex/ L&T/ Legrand/ ABB/ Siemens
Replacement of automatic timer switch astronomical type of capacity 32 amps 230 volts suitable for controlling of light fittings all as directed by Engr-in-Charge. Make : Indoasian cat No TL032ASO or equivalent of Bajaj.
Disconnecting electric connections from alternator and fuel connection for repair and servicing including dismantling diesel filter, fuel filter, air filter, rubber coupling, fan belts, hose pipes all as required at site by opening nuts bolts including repair to wiring of alternator and control panel if required, of DG set capacity 62.5 KVA to 63.00 KVA and replacement of old defective spare parts with new spare parts as mentioned here-in-after, including any type of machine work required at site/ workshop to compete the repair including complete servicing the engine all as required at site, re-assembling the spares in existing position complete and testing on completion all as specified and as directed by Engineer-In-Charge. Make of Engine and Alternator: SM No: Note: (a) New spare parts for engine will be measured and paid separately as supply only under the respective items. (b) Cost of cleaning, welding, minor repair and special tools and plants required for dismantling engine will deemed to be included in quoted rates.
Supply only following new spare parts required for repair of DG Set capacity 62.5 KVA to 63.0 KVA :-
Fuel Filter.
Oil Filter.
Air Filter.
Coupling rubber with assembly.
Fan belt.
Hose pipe set.
Carbon bush of alternator.
Carbon bush holder of alternator.
Ball bearing of alternator.
Slip rings assembly of alternator.
Disconnecting electric connections from alternator and fuel connection for repair and servicing including dismantling diesel filter, fuel filter, air filter, rubber coupling, fan belts, hose pipes all as required at site by opening nuts bolts including repair to wiring of alternator and control panel if required, of DG set capacity 15.0 KVA to 40.00 KVA and replacement of old defective spare parts with new spare parts as mentioned here-in-after, including any type of machine work required at site/ workshop to compete the repair including complete servicing the engine all as required at site, re-assembling the spares in existing position complete and testing on completion all as specified and as directed by Engineer-In-Charge. Make of Engine and Alternator: SM No: Note: (a) New spare parts for engine will be measured and paid separately as supply only under the respective items. (b) Cost of cleaning, welding, minor repair and special tools and plants required for dismantling engine will deemed to be included in quoted rates.
Supply only following new spare parts required for repair of DG Set capacity 30.0 KVA to 40.0 KVA :-
Fuel Filter.
Oil Filter.
Air Filter.
Coupling rubber with assembly.
Fan belt.
Hose pipe set.
Carbon bush of alternator.
Carbon bush holder of alternator.
Ball bearing of alternator.
Slip rings assembly of alternator.
Disconnecting all electric connections from alternator and fuel connection from engine, decoupling of engine and alternator, strip opening of diesel driven diesel generator of capacity 62.5/63 KVA, for repair, and complete for carrying out the overhauling after de-assembling the engine assembly, cleaning/ washing the engine block and other spare parts, replacing defective spare parts with new spare parts as required for smooth functioning of diesel engine and strip opening of alternator for repair by replacement of old defective spare parts including any type of metaling, welding, grinding, lath machine work required at site/ workshop to compete the repair the engine/ alternator, all as required at site, re-assembling the engine in existing position complete and testing on completion all as specified and as directed by Engineer-In-Charge. Note: (a) New spare parts will be measured and paid separately as supply only under the respective items. (b) Cost of cleaning, welding, minor repair and special tools and plants required for dismantling engine will deemed to be included in quoted rate. (c) Transportation cost of diesel engine/ alternator to workshop shall deemed included in quoted rate.
Supply only following new spare parts required for repair of DG Set capacity 62.5/63 KVA :- (i) Piston with piston pin, connecting rod and lock assembly complete.
(ii) Cylinder liner with liner ring assembly complete.
(iii) Piston ring set.
(iii) Piston ring set.
(iv) Major overhauling gasket set with 'O' ring set.
(v) Head valve inlet and exhaust.
(vi) Main Oil seal (Front and Rear).
(vii) Hose pipe with clips and joint set.
(viii) Fuel Filter.
(ix) Oil Filter.
(x) Air Filter.
(xi) Water Pump Assembly.
(xii) Solinoid Switch
(xiii) Servicing of radiator complete
Supply only following new spare parts required for repair of alternator of DG Set of capacity 25 KVA to 40 KVA :- (i) Slip ring assembly Bronze.
(ii) Carbon bush.
(iii) Carbon bush holder.
(iv) Ball bearing, size No- 6312.
(v) AVR (Automatic Voltage Rectifier/ Regulator).
(vi) Alternator and diesel engine coupling set.
Disconnecting all electric connections from alternator and fuel connection from engine, decoupling of engine and alternator, strip opening of diesel driven diesel generator of capacity 30.0/40.0 KVA, for repair, and complete for carrying out the overhauling after de-assembling the engine assembly, cleaning/ washing the engine block and other spare parts, replacing defective spare parts with new spare parts as required for smooth functioning of diesel engine and strip opening of alternator for repair by replacement of old defective spare parts including any type of metaling, welding, grinding, lath machine work required at site/ workshop to compete the repair the engine/ alternator, all as required at site, re-assembling the engine in existing position complete and testing on completion all as specified and as directed by Engineer-In-Charge. Note: (a) New spare parts will be measured and paid separately as supply only under the respective items. (b) Cost of cleaning, welding, minor repair and special tools and plants required for dismantling engine will deemed to be included in quoted rate. (c) Transportation cost of diesel engine/ alternator to workshop shall deemed included in quoted rate.
Supply only following new spare parts required for repair of DG Set capacity 30.0/40.0 KVA :- (i) Piston with piston pin, connecting rod and lock assembly complete.
(ii) Cylinder liner with liner ring assembly complete.
(iii) Piston ring set.
(iv) Major overhauling gasket set with 'O' ring set.
(v) Head valve inlet and exhaust.
(vi) Main Oil seal (Front and Rear).
(vii) Hose pipe with clips and joint set.
(viii) Fuel Filter.
(ix) Oil Filter.
(x) Air Filter.
(xi) Water Pump Assembly.
(xii) Solinoid Switch
(xiii) Servicing of radiator complete
Supply only following new spare parts required for repair of alternator of DG Set of capacity 15 KVA to 20 KVA :- (i) Slip ring assembly Bronze.
(ii) Carbon bush.
(iii) Carbon bush holder.
(iv) Ball bearing, size No- 6312.
(v) AVR (Automatic Voltage Rectifier/ Regulator).
(vi) Alternator and diesel engine coupling set.
Repair, calibration, checking and pressure testing of fuel injector pump assembly of DG set capacity upto 62.5/63.0 KVA including replacement of damaged/ defective parts, cups, barrel plunger and washers including transportation for workshop for repair, testing whole assembly after necessary repair and fixing in engine, complete all as specified and as directed by Engineer-In-Charge. Note: (a) New spare parts will be measured and paid separately as supply only under the respective items. (b) Cost of cleaning, welding, minor repair and special tools and plants required for dismantling and refixing with engine will deemed to be included in quoted rate.
Supply only following new spare parts required for repair of fuel injection pump (FIP) of diesel engine of DG Set capacity 62.5/63 KVA :- (i) Element for fuel injection pump.
(ii) Delivery valve for fuel injection pump.
(iii) Nozzle for fuel injection pump.
(iv) Feed pump for fuel injection pump.
(v) Bearing for fuel injection pump.
(vi) Oil seal for fuel injection pump.
(vii) Diaphram valve for fuel injection pump.
(viii) Repair kit minor for fuel injection pump.
Repair, calibration, checking and pressure testing of fuel injector pump assembly of DG set capacity upto 30/40 KVA including replacement of damaged/ defective parts, cups, barrel plunger and washers including transportation for workshop for repair, testing whole assembly after necessary repair and fixing in engine, complete all as specified and as directed by Engineer-In-Charge. Note: (a) New spare parts will be measured and paid separately as supply only under the respective items. (b) Cost of cleaning, welding, minor repair and special tools and plants required for dismantling and refixing with engine will deemed to be included in quoted rate.
Supply only following new spare parts required for repair of alternator of DG Set capacity 30/40 KVA (i) Element for fuel injection pump.
(ii) Delivery valve for fuel injection pump.
(iii) Nozzle for fuel injection pump.
(iv) Feed pump for fuel injection pump.
(v) Bearing for fuel injection pump.
(vi) Oil seal for fuel injection pump.
(vii) Diaphram valve for fuel injection pump.
(viii) Repair kit minor for fuel injection pump.
Replacement of old damaged/ unserviceable electronic rectifier/ Automatic Voltage Rectifier with new electronic rectifier/ Automatic Voltage Rectifier suitable for DG set capacity 62.5 KVA, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old damaged/ unserviceable electronic rectifier/ Automatic Voltage Rectifier with new electronic rectifier/ Automatic Voltage Rectifier suitable for DG set capacity 30/40 KVA, complete all as specified and as directed by Engineer-In-Charge.
De-assembling of radiator of DG set capacity from 15 KVA to 62.5KVA for cleaning and repair, using ‘K’ oil and radiator cleaning solution hydro-chloric acid by pressure of pump/ caustic soda with wire brush and necessary welding/ brazing of water tubes/ fins, whichever is required for cleaning and repairing, complete all as specified and as directed by Engineer-In-Charge.
Supply only engine oil/ lubricant, 20 W 40 grade, suitable for diesel engine of DG set of any capacity and any make, complete all as specified and as directed by Engineer-In-Charge.
Supply only coolant fluid suitable for radiator of DG sets of any capacity and any make, complete all as specified and as directed by Engineer-In-Charge.
Replacement of Old UNSV / damaged battery with new storage cell lead acid type 12 Volts, 150 AH including lead terminals and copper thimble for making necessary connections, complete all as specified and as directed by Engineer-In-Charge.
Supply only copper lead cable 1.50mtrs long, multi-stranded, with copper thimble for making necessary connections at both ends, suitable for 12/ 24 Volts battery including copper nuts, bolts and washers, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old damaged/ unserviceable coppercable with new cable, flat, PVC insulated and PVC sheathed copper conductor, multi-stranded, 50.0 Sqmm, single, conforming to relevant IS specifications including making connection to both ends i.e. motor side and starter side with jointing materials, complete all as specified and directed by Engineer-In-Charge.
Repair and overhauling of existing self starter, capacity 12 Volts/ 24 Volts of any diesel generator set including transportion to workshop for any repair and installation back to same DG set and replacing defective spare parts with new spare parts such as re-winding of armature, pinion, carbon bushes, field coil, including any type of machine work required at site/ workshop to compete the repair including complete servicing all as required at site, re-assembling in existing position complete and testing on completion all as specified and as directed by Engineer-In-Charge. Note: Cost of spare parts shall be deemed included in quoted rate of item.
Repair and overhauling of existing alternator for baterry charger (Dynamo), capacity 12 Volts/ 24 Volts of any diesel generator set including transportion to workshop for any repair and installation back to same DG set and replacing defective spare parts with new spare parts such as re-winding of armature, pinion, carbon bushes, field coil, including any type of machine work required at site/ workshop to compete the repair including complete servicing all as required at site, re-assembling in existing position complete and testing on completion all as specified and as directed by Engineer-In-Charge. Note: Cost spare parts shall be deemed included in quoted rate of item.
Rewinding of burnt/ damaged winding wire for Alternator of DG set of any capacity, self starter & Dynamo of any capacity with annealed solid copper conductor wire of existing specifications, insulating materials, ISI marked or as per IE specifications and cleaning, preparation of stator for rewinding, complete all as specified and directed by Engineer-In-Charge.
Repair & servicing of LT panel and Alternator terminal of DG set of any capacity, taking out burnt out wiring with minor spares, cleaning the panel with CRC including replacement of old burned wires of existing sizes with copper lugs of any size with nuts & bolts, replacement of casing & caping, fixing of new tags and testing complete all as specified and directed by Engineer-in-Charge Note :- (a) Quoted rates includes wiring, nuts, bolts & washers and cleaning materials (b) Rates of copper thimbles shall be measured & paid as supply only)
Supply only Copper tube terminal heavy duty (thimble) suitable for 16 Amps
Supply only Copper tube terminal heavy duty (thimble) suitable for 25 Amps
Supply only Copper tube terminal heavy duty (thimble) suitable for 50 Amps
Supply only Copper tube terminal heavy duty (thimble) suitable for 70 Amps
Supply only Copper tube terminal heavy duty (thimble) suitable for 120 Amps
Supply only Copper tube terminal heavy duty (thimble) suitable for 185 Amps
Supply only Copper tube terminal heavy duty (thimble) suitable for 240 Amps
Supply only Copper tube terminal heavy duty (thimble) suitable for 300 Amps
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates reduced by (-20)%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
SPECIAL NOTE FOR DG SETS AND VOLTAGE STABLIZER'S REPAIRS/PUMPS: The contractor will submit a scanned copy of Memorandum of under standing from OEMs ( or authorized dealers) to Engr-in-Charge for the respective E/M installations before start of any repair work for the Aprroval of GE. The details of OEMs are as under:- (a) DG Set (i) Kirlosker Green/Cummins (ii) Crompton Greaves (iii) Sudhir (iv) Mahindra (b) Servo Voltage Stablizer (i) Vinitek (ii) Electric field (iii) V-Gurad (c) Submersible and Centrifugal Pumps (i) Kirloskar (ii) KSB (iii) Jyoti
Amount of Schedule of credit of for Rs 1,24,180.00 shall be deducted from quoted amount.
M/S Chib Engineers
sahni construction co
M/S CJ CONSTRUCTIONS
M/S SHARMA ENTERPRISES
M/S ANMOL TRADING CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .