Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 LAccepted-AOC | ₹1.2 L Quoted ₹1.3 L | L1 | Accepted-AOC Being L1, Work has been awarded to M/s- Awasthi Elect and Cons Co. |
| Sl No | Description | Qty | Unit | Awasthi Electric and Cont. Co. L1 |
|---|---|---|---|---|
| 1.01 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (a) Group A | 8 | Pt | 5,600 ₹6,608 Lowest |
| 1.02 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 30 | Mtr | 8,700 ₹10,266 Lowest |
| 1.03 | (b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 35 | Mtr | 13,650 ₹16,107 Lowest |
| 1.04 | © 4 X 4 sq. mm + 2 X 4 sq. mm earth wire | 30 | Mtr | 17,700 ₹20,886 Lowest |
| 1.05 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. | 4 | Nos | 2,400 ₹2,832 Lowest |
| 1.06 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. (a) 12 Module (200mmX150mm) | 2 | Nos | 1,300 ₹1,534 Lowest |
| 1.07 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (a) 5/6 amps switch | 20 | Nos | 2,300 ₹2,714 Lowest |
| 1.08 | (b) 3 pin 5/6 amp socket outlet | 10 | Nos | 1,300 ₹1,534 Lowest |
| 1.09 | SITC of 4'-20 watt LED fitiing complete directly on ceiling/wall i/c connection with 1.5 sq. mm copper conductor single core cable etc. as reqd. | 6 | Nos | 3,450 ₹4,071 Lowest |
| 1.10 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required. | 2 | Nos | 2,200 ₹2,596 Lowest |
Tender Value
₹1.2 L
EMD Value
₹2,401
Closing Date
25 Sept 2024, 4:00 pmClosed
Executive Engineer (Electrical)
O/o Executive Engineer (Electrical) BSNL Electrical Division 1ST Floor, Bhopal House, Lalbagh Lucknow
Pdg Electrical work and Shifting and Reinstallation of 2 x 1.5 TR split AC unit from old TE Sec G to CSC at RTTC Compound Lucknow
2024_BSNL_208543_1
41/TEDL/BSNL/LKO/2024-25, Dated 03/09/2024
Open Tender
Electrical Works
Item Rate
15 days
LUCKNOW
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
ACCOUNTS OFFICER, (Cash), BSNL O/o PGMTD, LUCKNOW
₹2,401
6 Aug 2026
17 Sept 2024
26 Sept 2024
17 Sept 2024
25 Sept 2024
17 Sept 2024
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (a) Group A
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
(b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
© 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. (a) 12 Module (200mmX150mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (a) 5/6 amps switch
(b) 3 pin 5/6 amp socket outlet
SITC of 4'-20 watt LED fitiing complete directly on ceiling/wall i/c connection with 1.5 sq. mm copper conductor single core cable etc. as reqd.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Servicing & ITC of existing of ceiling fan / wall mounted fan i/c oiling,greasing , connection & testing etc as required.
S/Fixing of 4feet ,40W Lenear Hanging LED fitting ,hanging from ceiling i/c making connection etc complete as reqd (M/s Havells,philips,Bajaj or SS make)
Supplying and fixing of 400mm sweep oscilating type wall fan suitable for operation on 230 volts 50 Hz AC supply complete etc. as required.(M/s,Havells/ Crompton or SS make)
Dismantling of existing SAC unit from old TE Sec-G , along with indoor & outdoor unit,copper piping, cable stand etc as reqd.
Transportation of split AC unit with complete accessories i/c loading & unloading from TE Sec-G to CSC at RTTC Bldg Lucknow.
I.T.C. of 1.5 TR split AC unit i/c fixing of copper tubes covered with foam insulation in PVC flexible pipe, bending, brazing and leakage testing, laying/fixing of exisitng copper conductor cable, drain piping laying work etc. complete as required.
Supplying and fixing of copper refrigerant pipe with foam insulation of following size etc complete as required. (a) 1/4"
Supplying and fixing of prefabricated stand base frame made out of 14 swg MS sheet suitable for wall/floor mounting of condenser unit i/c cutting, welding, grouting with dash fastner, enamel painting, cutting the floor/wall and making good the same etc complete as required.
S/charging of refrigerant gas for in the refrigerant circuit of existing SAC unit, vacumising and leak testing etc as reqd
S/F of 3x2.5 sqmm cu conductor multy core cable direct on wall surface i/c connection, testing etc as reqd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].