| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹19.0 L+₹50,485 (2.73%)Rejected-Finance | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹21.2 L+₹2.7 L (14.7%)Rejected-Finance FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹22.5 L+₹4.0 L (21.6%)Rejected-Finance H NO 767 NEAR OLD POST OFFICE NEW VADDEM VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹24.8 L+₹6.3 L (34.3%)Rejected-Finance SALGAONKAR HOUSE DRIVERS HILL VASCO DA GAMA GOA 403802 | SOUTH GOA | GOA | 403802 | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹20.8 L
EMD Value
₹41,600
Closing Date
15 Feb 2020, 6:00 pmClosed
SH M V SANKAR SE CWE
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIR TO KARDEX BLDG NO P3 AT MO GOA UNDER GE GOMANTAK VASCO
2020_MES_314420_1
85218/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE GOMANTAK VASCO
₹41,600
Yes
19 Mar 2020
13 Jan 2020
18 Feb 2020
13 Jan 2020
15 Feb 2020
1 Feb 2020
Amount
Schedule 'A' -Part I (B & R Works)
Demolition of un reinforced cement concrete in ground floors n.exc 15cm thick above or below ground level all as specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets all as specified and as directed.
Dismantling of structural steel work including doors, gates but excluding framed truss etc all as specified and as directed.
Dismantling asbestos cement (corrugated, semi corrugated) sheets including ridges as in roof covering all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.
S&F Aluminium powder coated window/ventilators shutter including frame, any type sliding or openable with frame, & other similar work etc. fabricated by using the JINDAL/HINDAL CO standard section including necessary arrangements to receive 4mm thick glass or wire mesh with aluminium channel beading & stainless steel screws including the cost of rubber gasket/rubber beading etc. complete including necessary handles, roller wheels, hinges etc complete all as specified and as directed. Note :- Weight of aluminium section shall be measured exclusive of all fittings fixtures, hinges, handle, bolts, rubber gasket/rubber beading and locking arrangements.
S & F Mild steel 4 levers mortice lock type, size 100mm all as specified and as directed.
S&F Anodised aluminium snap grid frame work size of the false ceiling, and size of angle 25 mmx25 mm and thick size of grid 605x605 mm fixed with hangers 6mm dia, G.I. (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out G.I. flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia, 40 mm long complete all as specified and as directed.
S&F Gypsum board of 12 mm thick for false ceiling 60 cm x 60 cm with staples on snap grid all as specified and as directed.
Taking down cement plaster from brick or stone walls including racking out joints hacking for key, scrubbing down with water etc all as specified and as directed.
M&L for rendering 15 mm thick cement plaster with cement mortar 1:4 on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement with using water proofing compound all as specified and as directed. Note: WPC shall be measured and paid separately.
M&L for rendering 15mm thick cement plaster with cement mortar 1:6 on other than fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement all as specified and as directed.
M&L for rendering 5mm thick cement plaster with cement mortar 1:3 on concrete surface as in ceiling finished even and smooth without using extra cement all as specified and as directed.
Supply only Integral waterproofing compound.
M&L for plain cement concrete type B-2,1:2:4 using 40mm graded stone aggregate 100 mm thick as in of floorings. finished even and smooth and laid in bays of 1500 x 1500 mm all as specified and as directed.
M&L for glass dividing strips,3mm thick and width of strip in 38mm flooring of slab work etc all as specified and as directed.
Taking down chowkhat or frames of door/ window / ventilators with shutter(Without taking off shutter from the frame) not exceeding 1.50 m each all as specified and as directed.
Taking down chowkhat or frames of door/ window with shutters , without taking off shutter from the frame exceeding 1.50 m and not exceeding 4.00 Sq m each all as specified and as directed.
S&F Aluminium anodised barrel tower bolt 200 mm, extruded section all as specified and as directed.
S& F Aluminium anodised sliding door bolts with hasp and staple extruded section or cast aluminium alloy 300 mm long all as specified and as directed.
S&F 100 mm butt hinges, medium weight cold rolled mild steel all as specified and as directed.
S&F Aluminium anodised handle cast type 150 mm long all as specified and as directed.
S&F Glazing with 4 mm thick sheet glass ordinary type including rubber beddings/gasket around glass panes all as specified and as directed..
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surroundings, glazed with putty or fixed with beads all as specified and as directed..
S&F in repairs aluminium anodised wire mesh of size 1.5 mm x 3 mm mesh 20 Gauge thick all as specified and as directed. Make: M/S Kiran Netting or equivalent as approved by GE.
M&L for providing cement concrete type C-1, 1:3:6 using 20mm graded stone aggregate, 50 mm thick , 75 cm wide as in plinth protection laid in bays not exceeding 2 Sq m each and finishing even and fair on top without using extra cement with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand ( all by weight) all as specified and as directed..
M&L for PCC type C1 1:3:6 ,using 20 mm graded stone aggregate for filling the holes of the hold fasts all as specified and as directed..
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises all as specified and as directed..
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.06 Sq m but not exceeding 0.11 sq m, in floors etc. Set and jointed in neat cement slurry and pointed in coloured cement to match including 15 mm thick screed bed in cement and sand mortar 1:4 all as specified and as directed..
M&L for glazed ceramic tile 300 x 200 x 06-7mm thick (coloured) on vertical surfaces such as dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick screed bed in cement and sand mortar 1:4 all as specified and as directed..
M & L for screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in cement mortar 1:4 all as specified and as directed..
M&L for vitrified ceramic tiles l0mm thick 600mmx 600mm (square/rectangular) polished ,area of each tiles repairs in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match light shade all as specified and as directed..
M&L for preparation of new plastered surfaces and applying three coats of white wash on walls all as specified and as directed..
M&L for preparation of new plastered surfaces and applying three coats of white wash on ceiling all as specified and as directed..
M&L for preparation of old plastered surfaces and applying one coat of white wash on wall all as specified and as directed.
M&L for preparation of old plastered surfaces and applying one coat of white wash on ceiling all as specified and as directed.
M&L for preparation of new plastered surfaces and apply two coats of cement base paint on wall all as specified and as directed.
M&L for preparation of old plastered surfaces and applying one coat of cement base paint on wall all as specified and as directed.
M&L for preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide premier all as specified and as directed.
M&L for one coat of synthetic enamel paint to old steel surface over 10 cm width or girth including preparation of surfaces all as specified and as directed.
S&F in repairs 1.25 mm thickness of laths steel rolling shutters, without ball bearing gear operated type with bevel gear box and crank handle as specified including top cover, anchoring rod, hasp and one shop coat of primer, erected in position as indicated all as specified and as directed.
S&F Glazing with figured glass(Frosted), pin head type, 3mm thick, and glazing with oil putty and glazing pins in squares not exceeding 0.5 Sqm in each pane all as specified and as directed.
Taking up or down steel water tubing and connections of following sizes :-
(a) 15 mm bore
(b) 20 mm bore
S&F Mild steel galvanized steel tubing medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete of following sizes :-
(a) 15 mm bore
(b) 20 mm bore
All as per Item No.45 here in before but for re-fixing old steel tubing of following sizes including new fittings :-
(a) 15 mm bore
(b) 20 mm bore
S&F in repairs 15 mm dia CP bib tap cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe all as specified and as directed.
S&F in repairs 15 mm dia stop valves cast copper alloy screwed down high pressure , 15 dia bore all as specified and as directed.
S&F in repairs 20 mm dia stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle all as specified and as directed.
S&F in repairs 20 mm dia Ball valve high pressure PTMT with epoxy coated aluminium rod & high density plastic ball all as specified and as directed.
S&F in repairs PVC connection 15 mm size with PTMT nuts 450 mm long all as specified and as directed.
S&F in repairs PVC (Plastic polymer Cistern) valve less, Symphonic action type, flushing cistern of capacity 10 liters, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete all as specified and as directed. Make :- SLIMLINE ( ECONOMY) with front knob of Parryware or equivalent in Hindustan Sanitary ware
S&F in repairs vitreous china squatting pan "Orissa Pattern" size 580 x 440 mm in any coloured with integral foot rest including lime motor, 'S' trap and including taking down all as specified and as directed.
M&L for PCC 1: 2 : 4 type B-1 , using 20mm graded crushed stone aggregate 40mm thick as in floor finishing surfaces of concrete topping even and smooth without using extra cement all as specified and as directed.
S&F in repairs CI soil waste pipe in any length with or without ears with cement joints fixed in walls 100 mm dia including taking down old one all as specified and as directed.
All as per Item No. 55 here in before but for 75mm dia including taking down old one all as specified and as directed.
S&F in repairs CI Nahani traps 100 mm dia with grating including jointing to waste pipe fixed and gully traps fitted cement concrete type B1, 1:2:4 using 20 mm graded stone aggregate all as specified and as directed.
S&F in repairs rotational moulded polyethylene water storage tanks ISI Marked of 500 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top and bottom rails. M.S frame shall be covered with heat channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as a gap insert for top rail and bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S frame welded / sealed to the stiles and nails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at side all as specified and as directed.
Solid S&F Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube, supplying and fixing in opening all as specified and as directed.
S&F in repairs vitreous china wash hand basin white flat back, size 550x400mm including waster pipe , chromium plated waste coupling 32mm dia , bracket etc complete all as specified and as directed.
S&F in repairs 15 mm bore pillar tap, cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ wih long screwed shanks and fly nuts, screwed for iron pipe all as specified and as directed.
Schedule 'A' -Part II ( Internal Electrfication )
Taking down carefully copper/aluminium point wiring any type (light, fan socket or power) complete (fittings such as switches, ceiling roses pendants, regulators, sockets etc to be measured separately) removing materials at site and making good disturbed surfaces of walls floors etc all as specified and as directed
M&L for one light point or fan point controlled by one switch with cables 1.5 Sq mm copper cable FRLS multi stranded unsheathed drawn through & including PVC concealed conduit and 1.5 sq mm conductor cable for earth wire including making connection with common earth and earth dolly complete all as specified and as directed .
M&L for point wiring for 5 amp independent point with 1.5 sq mm copper wire & 1.5 sq mm copper wire as earth lead drawn through & including PVC concealed conduit of suitable size all as specified and as directed .
M&L for point wiring for 15 amp independent point with 4 Sq mm copper wire & 4 Sq mm copper wire as earth lead drawn through & including PVC concealed conduit of suitable size all as specified and as directed .
S&F Switch piano flush type single pole, one way 5 Amp all as specified and as directed .
S&F Switch socket combination 2 in 1, 5 pin, 5 Amp flush type universal all as specified and as directed .
S&F Switch socket combination 2 in 1, 5 pin, 15 Amp flush type universal all as specified and as directed .
S & F in Ceiling rose, 3 phase/ PVC / polycarbonate, isolated body complete all as specified and as directed.
S&F in repair MCB 6 to 32 Amps, Single Pole, braking capacity 10KA, B curve (ISI Marked) all as specified and as directed .
S&F in repair MCCB 100 Amps, 4 pole, braking capacity 16 KA complete all as specified and as directed.
S&F Sheet metal enclosure (DB) for incomer MCCB, vertical type, 8 way, triple pole and neutral, 415 volts, double door with 250 Amps rated bus bar complete all as specified and as directed.
S&F Sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 20 Amps all as specified and as directed .
S&F LED tube light fitting surface mounted integrated type with 20 watts LED having minimum 100 lumens/watt complete including taking down old fittings all as specified and as directed.
S&F LED light fitting Recess/Surface mounting LED flat panel 2'x2' with high efficient LEDs & glare free opal diffuser of 36 watts LED including taking down old fittings all as specified and as directed.
S&F Fan regulator electronic step type 120 watt 280 volt including removal of old one complete all as specified and as directed .
S&F in repairs ceiling fan 1200mm sweep (ISI marked), 230 volts, with connecting rod of length up to 2 m complete all as specified and as directed .
S&F in repairs Exhaust fan 300mm sweep, heavy duty, 230 volts all as specified and as directed . Note for Item Nos 78 and 79 : Old unserviceable fans shall be deposited in MES store
S&F Submain wiring with 2.5 sq mm three runs of single core multi stranded FRLS unsheathed PVC copper conductor cable 1100 Volts as per colour code drawn in casing capping including all accessories as required and connecting to Existing main switch board/DB & testing on completion including taking down old unserviceable sub main wiring complete all as specified and as directed .
S&F Submain wiring with 4 sq mm three runs of single core multi stranded FRLS unsheathed PVC copper conductor cable 1100 Volts as per colour code drawn in casing capping including all accessories as required and connecting to Existing main switch board/DB & testing on completion including taking down old unserviceable sub main wiring complete all as specified and as directed .
M&L earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to GI wire 4mm dia by means of bolts, nuts, check nuts & washers of GI or steel, and earth lead connected to main DB panel/meter box panel including necessary earth work and excavation of in any type of strata, chamber in PCC 1:2:4 type B-2 with PCC cover, GI tubing 15mm dia light grade for protection of GI wire, GI tubing 20mm dia for watering etc all as per electrical plate No 3 of SSR part-I including provision of earthing test point & connecting to electrical equipments and testing on completion all as specified and as directed .
Schedule 'A' -Part III ( External Electrfication )
Supply and Laying under ground cable XLPE insulated armoured heavy duty 1100 volts grade conforming to IS 7098 Part-1 1988 with aluminium conductor multi standarded including centre gland, lugs, jointing materials etc laid in trenches or fixed it to wall including taking down of existing cable of 50 Sq mm 3.5 core and PCC cable cover all as specified and as directed.
Excavation in trenches not exceeding 1.5 m width and not exceeding 1.5 m in depth getting out in hard/dense soil all as specified and as directed.
Excavation in trenches not exceeding 1.5 m width and not exceeding 1.5 m in depth getting out in soft disintegrated rock all as specified and as directed.
M & L for sand cushion in trenches for cable protection complete all as directed and as specified.
Supply and lay PCC cable cover class LV type 1 flat size 250mmx150mmx40mm all as specified and as directed.
M&L for Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil all as specified and as directed.
M&L for Removal of surplus soil to a distance not exceeding 50 m and depositing where directed
Supply and laying of High density poly-ethylene pipes (HDPE) 40 mm dia, pressure rating 6 kgf/sqcm laid in trenches all as specified and as directed.
K M Subhanaiah
M/S jvsr constructions
M/S DUBAL CONSTRUCTION
Tara Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .