Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC 179 143 1 INDA NEAR SHAKTI BHAVAN KHARAGPUR 721305 | MEDINIPUR WEST | WEST BENGAL | 721305 | ₹1.7 Cr | L1 | Accepted-AOC Lowest Bid Value |
| 2 | L2₹2.3 Cr+₹53.8 L (31.4%)Rejected-Finance | ₹2.3 Cr+₹53.8 L (31.4%) | L2 | Rejected-Finance Higher Bid Value |
| 3 | Rejected-Technical VILL PO KOTA VIA PANAGARH BAZAR DIST BURDWAN WB PIN 713148 | BURDWAN | BURDWAN | WEST BENGAL | 713148 | - | - | Rejected-Technical not enlisted in appropriate class |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
20 Apr 2021, 6:55 pmClosed
CWE AF KALAIKUNDA
CWE AF KALAIKUNDA, KALAIAKUNDA AIR FIELD POST, DIST WEST MEDINIPORE,721303
COMPLETION OF INCOMPLETE WORK FOR PROVN OF OTM ACCN FOR SMC
2021_MES_427006_2
8410/R-C/KKD(P)/04/E8
Open Tender
Civil Works
Lump-sum
540 days
AT AF STN SALUA
Class B, Category a(I)
2 documents required · 2 mandatory
₹1,000
Yes
GE AF KALAIKUNDA
₹2.1 L
Yes
31 May 2021
3 Apr 2021
22 Apr 2021
3 Apr 2021
20 Apr 2021
7 Apr 2021
3 Apr 2021 - 5 Apr 2021
Amount
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of single storied HOSPITAL BUILDING permanent specification complete all as specified and shown in drawing.
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of D.G. SET BUILDING with permanent specification complete all as specified and shown in drawing.
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of SUB STATION BUILDING with permanent specification complete all as specified and shown in drawing.
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of GARAGE BUILDING with permanent specification complete all as specified and shown in drawing.
Total amount of Sch 'A' Part-II (Site clearance and earthwork) Prepriced amount B/F from Sl page No. 24
Total amount of Sch 'A' Part-III (Internal Electrification) Prepriced amount B/F from Sl page No. 27
Total amount of Sch 'A' Part-IV (Internal water supply) Prepriced amount B/F from Sl page No. 28
Total amount of Sch 'A' Part-V (Road ) Prepriced amount B/F from Sl page No. 30
Total amount of Sch 'A' Part-VI (Sewage disposal) Prepriced amount B/F from Sl page No. 32
Total amount of Sch 'A' Part-VII (External water supply) Prepriced amount B/F from Sl page No. 33
Total amount of Sch 'A' Part-VIII (External electric supply) Prepriced amount B/F from Sl page No. 34
Total amount of Sch 'A' Part-IX (Area Drainage) Prepriced amount B/F from Sl page No. 35
Total amount of Sch 'A' Part-X (Addn/alten for B/R portion) Prepriced amount B/F from Sl page No. 39
Total amount of Sch 'A' Part-XI (Addn/alten for E/M portion) Prepriced amount B/F from Sl page No. 41
Sch 'A' Part-XII (Misc Items) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.5 signifies this fact only.
Sliding window aluminium anodized 15 micron with two track top & two track bottom with two track outer frame work including roller etc. All section will be 65 x 30 mm and 1.5 mm thick complete with handle, cleat , glazing clips, neoprene dry set, rubber gasket with 5mm thick tinted toughen glass including aluminium guard bar, 50mm long tower bolts etc as required complete all as specified and as directed.
S & F aluminium anodised electro colour ventilator incl frames shutters , 5mm thick tinted glass, pivot hinges, aluminium hard wares, any type of gasket etc. complete all as specified and as directed.
S & F aluminium anodised door with frame with shutter made of aluminium section of required sizes including necessary cleats, glazing cleats, rubber gasket, hinges, aluminium snap beading, aluminium handles, special cylinderical blocks, neoprane dry set, 5.5mm thick glazing, bottom door section with auto hydraulic floor mounted door closer etc complete all as specified and as directed. (Note :- Frame section 63.5 x 38 x 1.65 mm thick, joint angle of door 50 x 50 x 4.7 mm thk, door style 85 x 44.5 x 2mm thk, shutter style, top and bottom rail 95.3 x 44.5 x 2mm thk, lock rail 100 x 45 x 2mm thk and glass clip 31.5 x 17.6 x 1.1 mm thk ). Half portion of the door glazed with 5.5mm thick glass and bottom portion fixed with 5mm thick high pressure laminated sheet provided with power coated aluminium air grill.
M & L for providing bituminous primixed carpet 25mm consolidated thick with 0.34 cum stone chipping mixed with 18.25 kg of binder (using paving bitumen) rolled with power roller exc 08 ton and n exc 12 ton and compacted to reqd camber and gradient complete all as specified and as directed.
Supply and plantation of korean grass including preparation of ground to required depth and filling of sweet earth, cow dung and watering etc. complete all as specified and as directed by Engr in Charge
Supply and plantation of Ashoka plants (height of plant not less than 45 cm above ground level) including preparation of ground upto 60cm deep and filling of sweet earth, cow dung, vermi compost and watering etc complete all as specified and directed by Engr-in-Charge
Supply and plantation of bouganavilia including preparation of ground up to 30 cm deep and filling of sweet earth, cow dung, vermi compost and watering etc complete all as specified and as directed by Engr -in- Charge
Supply and plantation of crotons and hedges, including preparation of ground to required depth and filling of sweet earth, cow dung and watering etc complete all as specified and as directed by Engr -in-charge
S & F GI tubes (medium grade) 25mm dia galvanised with all fittings and fixed to walls and ceilings or laid in floor complete all as specified and as directed by Engr-in-Charge
S & F GI tubes (medium grade) 20mm dia galvanised with all fittings and fixed to walls and ceilings or laid in floor complete all as specified and directed by Engr-in-Charge
S & F 20mm dia (3/4 inches) sprinkle with fittings complete all as specified and as directed by Engr- in- Charge
Maintenance of the plants and grass planted vide serial item No 18 to 21 above by weeding, hosing, saucer melding once in every 15th day, planting, new plant / grass in placed of dead plants / grass of same species and height with out any extra cost to the department and as directed by Engr -in- Charge complete for the period of one year.
S&F water jet spray for EWC complete all as specified and as directet.
Supply installation and comissioning of hi wall split unit indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality of Capacity 2.0 TR single phase driven duly filled by NON CFC and complete with all accessories single phase 240Volts, 50 Hz complete of 05 star rating.
Supply installation and comissioning of hi wall split unit indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality of Capacity 1.5 TR single phase driven duly filled by NON CFC and complete with all accessories single phase 240Volts, 50 Hz complete of 05 star rating.
Supply and fix voltage stabilizer single phase 240 Volts wall mounted 5 KVA copper wound with automatic operation air cooled indoor type for input variation 200 V to 250 V with output voltage stablized 230 V with digital Amps/Voltmeter including electric connection from sources complete all as spd and directed by Engr-in- charge
S & F MCB Single pole and neutral 5 to 32 Amps C curve 10 Ka complete all as specified and as directed.
Dismantling /taking down any type , any capacity , any make Distribution board complete and making good the disturbed surface all as directed by Engineer -in -Charge
M&L for MCB Triple pole and neutral 415Volts 63 A 10 kA C curve complete all as spd and directed by Engr-in- Charge .
S & F MCB Single pole and neutral 6 to 32 Amps C curve 10 Ka complete all as specified and as directed.
S & F MCB Single pole 10 Ka C curve 6-32Amps complete all as specified and as directed.
M & L for servicing of exhaust fan including painting with the existing colour paint , greasing complete all as specified and as directed
M&L for sub main wiring with two single core 6 Sqmm copper conductor cable PVC insulated and unsheathed stranded incl drawing through concealed PVC conduit non metallic 25 mm dia with all accessories like bend,Tee , junction concealed on wall incl 6 Sqmm PVC insulated unsheathed copper conductor cable as earth wire complete all as specified and as directed. Note- Twon run of 6 sq mm ans one run of 6 sq mm PVC insulated coppwer wire and one run of PVC conduit shall be measured as one unit
M&L for sub main wiring with four single core 6 Sqmm copper conductor cable PVC insulated and unsheathed stranded incl drawing through concealed PVC conduit non metallic 25 mm dia with all accessories like bend,Tee , junction concealed on wall incl 2x6 Sqmm PVC insulated unsheathed copper conductor cable as earth wire complete all as specified and as directed. Note- Four run of 6 sq mm and two run of 6 sq mm PVC insulated coppwer wire and one run of PVC conduit shall be measured as one unit
Supply and fix security light LED 45W of luminarie type BRTFG 45W LED WW including fittment accessories complete and GI pipe 50 mm dia medium grade 1.5 Mtr long and bend to shape incl for brackets and 02 Nos M S clamps 25x6 mm flate with 04 Nos fully threaded bolt nuts washers and fixed on wall complete with connection with 3 core copper cord of size 1.5 sq mm all as specified.
Supply installation and comissioning of hi wall split unit indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality of Capacity 1.0 TR single phase driven duly filled by NON CFC and complete with all accessories single phase 240Volts, 50 Hz complete of 05 star rating.
Supply and fix voltage stabilizer single phase 240 Volts wall mounted 4 KVA copper wound with automatic operation air cooled indoor type for input variation 200 V to 250 V with output voltage stablized 230 V with digital Amps/Voltmeter including electric connection from sources complete all as spd and directed by Engr-in- charge
Cutting the road for laying the GI pipe line of 50mm dia and making good to the existing road surface with 20mm aggregate PCC concrete type B1 of ratio 1:2:4 thickness not less then 10 cm to the level of the road.
M & L brick masonry valve chamber of internal size 0.6 M x0.6 M x 0.6 M with 23 cm thick wall in CM 1:6 including excavation, earth work in any strata & PCC 1:4:8 foundation type D-2, 75 mm thick including 20 mm thick PCC 1:2:4 type B1 in & plastering the internal surface with 10 mm thick cement mortar 1:4 providing 3.15 mm MS sheet chamber cover double opening arrangement center lock system with40x40x6mm angle iron frame duly painted with two coat of black bituminous paint over one coat of red oxide primer complete all as directed Engr -in -charge.
Supply laying jointing and testing of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (heavy duty with aluminium conductor, 11000V grade of size 3 core cross sectional area 95 sqmm complete all as specified and as directed.
Supply laying jointing and testing of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (heavy duty with aluminium conductor, 1100 V grade cross sectional area 120 sqmm 3.5 core complete all as specified and as directed.
Supply laying jointing and testing of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (heavy duty with aluminium conductor, 1100 V grade cross sectional area 50 sqmm 3.5 core complete all as specified and as directed.
M & L for brick size fly ash dry laid flat including punned sand cushioning for cable protection complete all as specified and as directed.
M & L for cable jointing kit for 11 KV (E) grade cable for straight through cold shink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as spd and directed by Engr -in -charge.
M & L for cable jointing kit for 11 KV (E) grade cable for in door termination cold shink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 95 sqmm complete all as spd and directed by Engr -in - Charge.
Supplying and laying unreinforced precast concrete cable cover, class HV Type 1 flat size 300x180x40mm complete all as specified and as directed.
Supply install, testing and commissioning of power transformer, capacity 100KVA step down, indoor type floor mounting,double copper wound core type 3 phase 50Hz AC oil immersed with ONAN type cooling with external cooling tubes/radiators having no load voltage ratio 11/0.433KV (corrosponding to principal tapping delta conduct on primary side first (HV incoming) and star conduct on secondary side (secondary out going) in accordance with vector group symbol (DYN-11) conforming to IS 2026 I977 and having of load tap changer in the steps of 2.5% on HV side to take care of voltage from (+-)7.5% (+-)5% to (+-)2.5% to give of output on 433V secondary side and including initial oil filling to appropiate level , control cable and following standard fittings complete. (i) Oil conservator with oil fillinghole cap and drain plug. (ii) 01 No of prismatic oil level guage mounted on conservator wall with first fill of charge upto maximum level. (iii) Silica gel dehydrating breather with oil seal and with first fill of charge. (iv) Pressure release valve with automtic reseting arrangement after release of pressure -01 set (v) Adequate No of thermometer pocket including one thermometer. (vi) Top oil filter valve. (vii) Bottom oil filter cum drain valve. (viii) Rating diagram and terminal marking plate. (ix) Earthing terminal- 02 Nos (x) Liffiting lugs-01 set (xi) Jacking pads -01 set (xii) Under crriage with 4 Nos of plain rollers. NOTE: 1. The transformer shall be tested as type test and routine test as per IS 2026 in persence of GE/his rep. 2. The contractor shll submit QAP (Quality assurence programm) after the 15 days from placement of order for transformer testing to factory. 3. The manufacture/contractor shall furnish original BILL certificate (paid voucher and test certificate ) of the CRGO manufactorer. 4. The manufracture/contractor shall furnish the diameter of LV and HV copper winding and its total resistance. The stray losses shall be specified in percentage terms. The percentage of NO load and full load losses shall be as per IS 2026. 5. The contractor shall get the approval of GE for the make of the tranformer they plan to procure. 6. Prior to manufacturing the general arrangement drawing design details of the transformer shall be got approved by GE. 7. Seprate neutral bushing shall be brought out for earthing.
Supply, install, commissioning and testing of HT 11 KV 3phase, 50Hz totally enclosed metal clad gear panel suitable to accommodate vaccum circuit breaker (VCB) drawn out type with connecting protective device and meter factory made indoor type vertical isolation,horizontal withdrawal metal clad copper termination and connection for incoming and out going cable as required relay operation complete as per IS10/19/2009:3118 and IEC 56 all as specified and comprising of the following accessories:- (a) HT 11 KV 3 Phase 50Hz VCB 350 MVA 630Amp 18.1KA with O/L & E/F protection by microprocessor relay Amp & voltmeter etc 01 No. (b) Supply, install, commissioning and testing DC power source for protective relay control microprocessor based 230volts /110volts DC 30 Amps for 11KV VCB panels and comprising of the following:- (c) Housing circuit breaker carriage with provision of cable termination. (d) Mechanical interlock and automatic saftey shutter gear including pad locking arrangenment. (e) Isolating plugs (f)Bus bar chamber with 3 phase copper bus bar 1000Amp rating insulated -01 set (set of three) (g) Electrical trip coil 110V DC-01 No (h)Electrica;l shunt coil 110V DC -01 No (i) CT Chamber incororating 3 Nos single phase rasin cast current transformer ratio 100/50/5-5 class 1.0 for metering & class 5P10 for protection and burdon 15VA-1 Nos (j) 3 Phase 3 limb draw out type bus connected Epoxy potencial transforer ratio 11KV/√3/110V/√3 AC accuracy 1.0 burden 200VA- 01 No. (k)Digital ammeter 0 to 100 Amp (100% of CT ratio) for 3 phase -01 No. (l) Digital voltmeter rating 0 to 12KV for 3 phase -01 Nos (m) Digital load manager for amps, volts,KW,KVA,KVAR,and PF type QUASER of Enercon/L&T -01 No (n) Three phase over current and earth and earth fault relay digital numerical auxillary supply 20-110V AC/DC OT out put contact 2 No +NC,rating -5,O/C Is= 20-200% in step of 5% E/F Os +5-80% inb step of 5% the features and specification conforming to model No. MI COM P 122 of AREVA or equivalent make of ABB or Seimens. (o) Auxiliary relay with 4N/O & N/C- 1 Nos (p) TNC switch and LR switch -01 Nos (q) Heat control switch -1 Nos (r) RYB, ON/Off,spring chared and discharged and VCB trip indications-01 set (s) Special heater with thermostate- 01 No (t) Operating counter-01 No (u) Rear cable box suitable for 95 sqmm 3 core XLPE cable (v) Spring charging motor with starter 230V AC-1 No
Supply , installation,testing and commissioning of silent diesel engine driven Get Set with acoustic cover to control the noise level as per limit of central pollution control board and including AMF panel 100 KVA capacity 3 Phase 415 Volts 1500 Rpm, 4 wire 50 Hz with following and including two year maintenance spares and ste pf tools as recommended by manufacturer :-(a) PRIME MOVER :- Suitable for driving 125 KVA alternator , water cooled battery start diesel engine of adequate BHP conforming to BSS frame pedestal support with anti vibration pad rated for continuous running capable of taking 10 % over load for one hour in any 12 hours operation with following standard accessories for engine ; (i) Battery 12 Volts 180 AH (25 Plates) including battery box or housing. (ii)Fly wheel and flexible coupling with guard. (iii) Hour meter and RPM meter. (iv)Instrument panel with Lubricate oil temperature and pressure gauge, battery charge indicator meter , high temperature gauge. (v) Fuel tank as per manufacture design. (iv) Exhaust pipe brought out side the room covered with 12 mm dia asbestors rope. (b) ALTERNATOR :-100 KVA Capacity at 0.8 PF brush less self excited, self regulated , 3 Phase, 4 wire ,50 Hz 415 Volts 1500 RPM screen protected drip proof free from stimulation problem continuous rating conforming to BS : 2613 complete with automatic voltage regulator between = /- 5 % or voltage from no load to full load (c) AMF PANEL :- AMF panel for 100 KVA DG Set factory made enclosure of CRCA sheet cubinal type floor mounted complete with internal connection of and accessories including digital type volt meter, ammeter, frequency meter, power factor meter, indicators, set of relay and associated accessories for starting the engine on main feature as well low voltage, over and under voltage relay, auxiliary contractor with timer (on delay). NOTE ;- (i) Any fittings /fixture are deemed to be included above which are required for its proper fuctioning. (ii) Necessary foundation for installation of DG set confirming to CPCB-2 norms shall be provided as per manufacture design and cost deemed inclusive for the item rate.(iii)Make of AMF panel shall be as per the recommendation of manufacturer /OEM of the DG set.
M&L for errection of two pole structure consisting of 02 Nos prestressed concrete pole 11.0 Mtr long 152x152 mm at top and 152x260 mm at bottom class 9 complete with excavation and PCC 1:4:8 with 40 mm graded stone aggregate type D2 for foundation and 1:3:6 type C2 with 40 mm graded stone aggregate for couping and 2.1 Mtr long MC 100 chanel 06 Nos with MS clamps made out of 50x6 mm 02 Nos for each chanel fixed with nut bolt and washer complete . 02 Nos bracing suport made out of ISA 40x40 steel equal angle with nut bolt and washers shall be provided in cross manner in centre of two pole including welding, bending cold or hot, drilling of holes for bolt any type or shape, type as indicating or directed and inclusive of all Ms work one coat primer under one coat of aluminium paints . Anti clmbng device spike type fabricated out of MS bas ( round ) incl nutbolts washers and welding in two halves made to shape to suit the cross section of pole all as sps and directed by Engr-in- Charge .
Supply of Rubber mat of 1 mtr X 2 mtr X 10 mm complete all as specified and as directed.
S& F cast iron cable route indicator in round shape duly marked/engraved :CABLE HT 11KV " fixed on RCC block of size 250mmX250mmX250mm complete all as specified and as directed. by the Engineer in charge.
Cutting the road for laying the XLPE cable 95 sqmm and making good to the existing road surface with 20mm aggregate PCC concrete type B1 of ratio 1:2:4 thickness not less then 10 cm to the level of the road complete all as specified and as directed.
Supply and fix security light fitting LED 45W of luminarie type BRTFG 45W LED WW and fitment accessories complete including necessary clamps and pipes
M & L for earthing with copper plate 60 X60 cm X 3.15 mm thick electrode thick buried directly in ground (Earth plate do not less than 3.0 M in deep below ground level ) with top edge of the plate not less than 1.5 m below normal ground level connected to copper strip 20 x 3 mm by means of bolts, nuts, check nuts and wahers of galvanized iron all as directed by Egnr -in charge and connected to earthing test point all as specified and directed including necessary earth work in any type of strata and PCC 1 : 3 :6 type B1 for chamber and RCC chamber cover 50 mm thick in lieu of CI cover and copper strip protected By 40 mm GI pipe light grade complete Note :- (i) The quoted rate includes the rate of Magnesium sulphate of 40 Kg per earth pit poured with salt and charcoal (to obtained earth resistance value and prepare test sheet of newly constructed earth pit shall be responsibity of constract) (ii) If the desired earth resistanc ie less than 1 ohms is not obtained the earthing shall be re-done by contractor with out any extra cost to Govt complete all as specified and directed.
Supply and fix 1 X 20 watt energy saving, surface mounted LED light fittings with high efficiency PMMA diffuser gives soft glare free light IP 20 protection, electric driver including 1X20 watt LED OEM tube light etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed
Supply and fix 1 X 10 watt energy saving, LED recess mounted of pressure die-cast aluminium luminaire in powder coated white finish on round profile with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed
Supply and fix 1 X 36 watt energy saving, flat panel for armstrong/grid ceilling complete with electronic driver & high brightness SMD LEDs complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.
Supply and fix 1 X 20 watt energy saving,CMRI certified LED flameproof, IP 65 protection complete with electronic driver & high brightness SMD LEDs complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.
Supply and fixing LED light fittings as bldg security light new generation energy saving,environmental friendly long life versatile pressure dire-cast aluminium IP 65 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver accessories suitable for & including 1X25 watts LED lamp coplete and 40 mm dia bore GI pipe mounting bracket not exceeding 1.5 mtrs long consisting with MS clamps made out of 40X6mm MS flat with bolts & nuts of appropriate size including necessary connection with 3X1.5 sqmm PVC of insulated stranded copper cable not exceeding 2 mtr long from ceilling rose complete all as specified and as directed.
M&L LED Lumeno 5 W E27 WW Ball lamp complete all as specified and as directed by Engr-in-charge.
Supply and fix 1 X 10 watt LED mirror light fittings of recess / surface mounted luminaire, Provided with high output diffuser , length of fitting 1ft (30cm) including 1 X10 watt LED OEM Tube light etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.
Supply & fixing TPN vertical DBs 4 way with provision to mount TPN V- Tec 16 KA MCCB upto 100 Amps MCCBs as incomer complete all as specified and as directed.
Supply and fixing ceiling fan 1200 mm sweep, energy saving 240 Volt complete with down rod complete 5 star rating all as specified and directed by Engr-in-Charge
Supply, assembling & fixing exhaust fan with louvers complete of 300mm sweep, 230 volts, single phase, AC supply complete with bolts, nuts, and washers size of the bolts 6 inch long 6mm dia embedded in the wall including provisioning of flexible cord copper of size 23/0.0076 three core from ceiling rose to exhaust fan for giving connection and providing continues earthing connection complete all as specified. Note:- (a) cost to the suitable opening in wall for fixing of exhaust fan is deemed to be included in the cost of building.
Supply and fixing MCB TPN 40 Amps, 415 Volts, 'C' Series 50 Hz rupturing capacity 10 KA complete all as specified and as directed.
Supply and fixing MCB SPN 40 Amps, 240 Volts, 'C' Series 50 Hz rupturing capacity 10 KA complete all as specified and as directed.
Supply and fixing MCCB 4 pole 100 Amps, capacity 16 KA. With fixed thermal magnetic release complete all as specified and as directed.
M&L for telephone point wiring using PVC insulated copper conductor cable with 2 pair of size 0.51 mm dia drawn into 20 mm dia PVC heavy duty right concealed conduit in wall/ceiling with terminal box at one end and other end terminated in telephone junction Box complete all as specified and as directed.
S&F telephone jack switch type with shutter complete all as specified and as directed.
S&F carbonate/thermo plastic telephone junction box of cap 20 pair suitable for terminate two Nos unarmoured 20 pair telephone cable with the outing telephone wires for different outlets in two single pieces "KRONE" type connector with IP 55 Protection and metric knockouts for cable entry complete all as specified and as directed.
S & F MCB DB in sheet metal enclosure Single pole and neutral 8 Way with 200 Amps rated coper bus bar double door protection complete all as specified and as directed.
M&L for submain wiring with PVC insulated unsheathed, stranded copper conductor cable (1100 volts grade)of size 4 x 10.0 + 2x 10 sq mm (conduit dia 25 mm) including PVC insulated cable of stranded copper conductor cable for earth continuity of size mentioned connected to common earth dolly and to be drawn in concealed heavy duty rigid PVC conduit Note : 6 of line conductor and one run of earth continuity conductor shall be measured as unit length
M&L for submain wiring with PVC insulated unsheathed, stranded copper conductor cable (1100 volts grade)of size 2 x 6.0 + 1x 6 sq mm (conduit dia 25 mm) including PVC insulated cable of stranded copper conductor cable for earth continuity of size mentioned connected to common earth dolly and to be drawn in concealed heavy duty rigid PVC conduit Note : 3 of line conductor and one run of earth continuity conductor shall be measured as unit length.
S & F MCB DB in sheet metal enclouser Single pole and neutral 12 Way with 200 Amps rated coper bus bar double door protection complete all as specified and as directed.
M/L for earthing complete with galvanised steel earth plate electrode of size 60 cm x60 cm x 6.0mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge not less than 1.5 m below ground level,connected to galvanised wire 4.0mm dia as earth lead by means of bolts, nuts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR part I, connected to earth test point all as specified or indicated complete with excavation, earth work, PCC 1:3:6 pit with RCC cover 50 mm thick with suitable handle made of 10mm dia MS bar, 20mm bore GI tubing medium grade for watering pipe, 15mm bore medium grade GI pipe for protection of 4.0mm dia GI earth lead, test point, GI funnel with wire mesh all as directed and specified and testing on completion.
BHOWMICK ENTERPRISES INDIA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .