| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹44.1 L+₹6.0 L (15.8%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹45.6 L+₹7.5 L (19.8%)Rejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹46.6 L+₹8.6 L (22.5%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹48.1 L+₹10.1 L (26.5%)Rejected-Finance H NO 309 REHARI COLONY JAMMU DISTT JAMMU J K 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
10 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (UTILITIES) UDHAMPUR
GE (UTILITIES) UDHAMPUR, PO-GARHI,PIN-182121
Repair/replacement of LT Infrastructure spares at certain different locations of CPH and MPH area under GE (Utilities) Udhampur.
2022_MES_537810_1
GE/U-29/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (UTILITIES) UDHAMPUR
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (UTILITIES) UDHAMPUR
₹97,000
Yes
28 Sept 2022
13 Jul 2022
12 Aug 2022
13 Jul 2022
10 Aug 2022
27 Jul 2022
Amount
Taking down the old/vintage LT feeder pillar box from the circuit system and supply & fix new LT feeder pillar box of following nomenclature as illustrated below:- Type:- System integrator switchgear/Channel Partner. Switchgear Make:- L&T/ABB/Schnieder/ Simens/Havells. Panel Sheet thickness:- 3.15 mm CRCA. Voltage:- 415V,3 Phase, 50 HZ. Bus Bar:- Aluminium bus bar shall be 1.5 times of incomer MCCB. Type:- Outdoor Panel. Base:- Angle iron 50x50x6 mm. Accessories:- Indication lamps (R,Y,B) CTs (required incomer size), Voltmeter,Ammeter,Cable glands whereever required. Wiring:- Wiring shall be 2.5 sqmm for acc.(Copper) Size of Panel:- Size as per switchgear accomodation,double door system, hinges to be provided, powder coated to complete panel. Foundation:- PCC foundation, M-15,Type C-1 according to panel including PCC coping, M-15. Incoming:- MCCB 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No.
All as per serial item No-01 here-in-above but with following accessories:- Incoming:- (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 400 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No. Outgoing:- (a) MCCB 4 pole , Ics=100%Icu- 25/26 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -04 Nos. (b) MCB TPN 63 Amps - 02 Nos.
All as per serial item No-01 here-in-above but with following accessories:- Incoming:- (a) MCCB 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No. (b) MCB SPN 63A- 10 Nos.
All as per serial item No-01 here-in-above but fwith following accessories:- Incoming:- (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 250 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No. Outgoing:- (a) MCCB 4 pole , Ics=100%Icu- 16 KA, 415 Volts, 125 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -03 Nos.
All as per serial item No-01 here-in-above but following capacity:- Incoming:- (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 300/320 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No. Outgoing:- (a) MCCB 4 pole , Ics=100%Icu- 25/26 KA, 415 Volts, 160 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos. (b) MCCB 4 pole , Ics=100%Icu- 25/26 KA, 415 Volts, 63 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 No.
All as per serial item No-01 here-in-above but following capacity:- Incoming:- (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 400 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No. Outgoing:- (a) MCCB 4 pole , Ics=100%Icu- 35/36KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos. (b) MCCB 4 pole , Ics=100%Icu- 25/26 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos.
All as per serial item No-01 here-in-above but with following accessories:- Incoming:- (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 300/320 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No. Outgoing:- (a) MCCB 4 pole , Ics=100%Icu- 25/26KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -03 Nos.
All as per serial item No-01 here-in-above butwith following accessories:- Incoming:- (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 500 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No. Outgoing:- (a) MCCB 4 pole , Ics=100%Icu- 25/26KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -03 Nos. (b) MCCB 4 pole , Ics=100%Icu- 18 KA, 415 Volts, 63 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 No.
All as per serial item No-01 here-in-above but with following accessories:- Incoming:- (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 320 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No. Outgoing:- (a) MCCB 4 pole , Ics=100%Icu- 25/26KA, 415 Volts, 160 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos. (b) MCCB 4 pole , Ics=100%Icu- 25/26 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos.
Supply, installation, testing and commissioning of out door type, weather proof, cubical panel board made out of 3.15 mm thick MS/CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle, embedded in PCC 1:2:4 type B-1 bLocks of size 15x15x20 cm, front and back openable, double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gasket etc for natural air flow of capacity suitable for 3 phase 4 wire 415 volts 50 Hz, factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof, IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel. Copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete, suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equipments: - (a) Aluminium bus bar of capacity duly covered with colour coaded shrinkable sleeves not less than1200 amps for phases and neutral - 01 set.
Supply, installation, testing and commissioning of out door type, weather proof, cubical panel board made out of 3.15 mm thick MS/CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle, embedded in PCC 1:2:4 type B-1 blocks of size 15x15x20 cm, front and back openable, double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gasket etc for natural air flow of capacity suitable for 3 phase 4 wire 415 volts 50 Hz, factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof, IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel. Copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete, suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equipments: - (a) Aluminium bus bar of capacity duly covered with colour coaded shrinkable sleeves not less than 800 amps for phases and neutral - 01 set.
Supply, installation, testing and commissioning of out door type, weather proof, cubical panel board made out of 3.15 mm thick MS/CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle, embedded in PCC 1:2:4 type B-1 blocks of size 15x15x20 cm, front and back openable, double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gasket etc for natural air flow of capacity suitable for 3 phase 4 wire 415 volts 50 Hz, factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof, IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel. Copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete, suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equipments: - (a) Aluminium bus bar of capacity duly covered with colour coaded shrinkable sleeves not less than 600 amps for phases and neutral - 01 set.
Supply, installation, testing and commissioning of out door type, weather proof, cubical panel board made out of 3.15 mm thick MS/CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle, embedded in PCC 1:2:4 type B-1 blocks of size 15x15x20 cm, front and back openable, double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gasket etc for natural air flow of capacity suitable for 3 phase 4 wire 415 volts 50 Hz, factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof, IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel. Copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete, suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equipments: - (a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 400 amps for phases and neutral - 01 set.
Supply, installation, testing and commissioning of out door type, weather proof, cubical panel board made out of 3.15 mm thick MS/CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle, embedded in PCC 1:2:4 type B-1 blocks of size 15x15x20 cm, front and back openable, double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gasket etc for natural air flow of capacity suitable for 3 phase 4 wire 415 volts 50 Hz, factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof, IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel. Copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete, suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equipments: - (a) Aluminium bus bar of capacity duly covered with colour coaded shrinkable sleeves not less than 800 amps for phases and neutral - 01 set.
Supply, installation, testing and commissioning of out door type, weather proof, cubical panel board made out of 3.15 mm thick MS/CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle, embedded in PCC 1:2:4 type B-1 blocks of size 15x15x20 cm, front and back openable, double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gasket etc for natural air flow of capacity suitable for 3 phase 4 wire 415 volts 50 Hz, factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof, IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel. Copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete, suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equipments: - (a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 500 amps for phases and neutral - 01 set.
Supply, installation, testing and commissioning of out door type, weather proof, cubical panel board made out of 3.15 mm thick MS/CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle, embedded in PCC 1:2:4 type B-1 blocks of size 15x15x20 cm, front and back openable, double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gasket etc for natural air flow of capacity suitable for 3 phase 4 wire 415 volts 50 Hz, factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof, IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel. Copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete, suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equipments: - (a) Aluminium bus bar of capacity duly covered with colour coaded shrinkable sleeves not less than 800 amps for phases and neutral - 01 set.
Supply, installation, testing and commissioning of out door type, weather proof, cubical panel board made out of 3.15 mm thick MS/CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle, embedded in PCC 1:2:4 type B-1 blocks of size 15x15x20 cm, front and back openable, double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gasket etc for natural air flow of capacity suitable for 3 phase 4 wire 415 volts 50 Hz, factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof, IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel. Copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete, suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equipments: - (a) Aluminium bus bar of capacity duly covered with colour coaded shrinkable sleeves not less than 600 amps for phases and neutral - 01 set.
Supply, installation, testing and commissioning of out door type, weather proof, cubical panel board made out of 3.15 mm thick MS/CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle, embedded in PCC 1:2:4 type B-1 blocks of size 15x15x20 cm, front and back openable, double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gasket etc for natural air flow of capacity suitable for 3 phase 4 wire 415 volts 50 Hz, factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof, IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel. Copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete, suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equipments: - (a) Aluminium bus bar of capacity duly covered with colour coaded shrinkable sleeves not less than 500 amps for phases and neutral - 01 set.
Note for serial item No 10 to 18: - (i) Rates quoted by the contractor shall deemed to be included for:- (a) Connection of incoming & outgoing cables using suitable size of aluminum lugs, nuts and bolts. (b) Necessary PCC and earth work required as per the existing panel for the grouting of panel legs complete all as directed by Engineer-in-Charge. (c) Drawing for LT panel board shall be submitted to department for approval before procurement.
Taking down the U/S panel mounted in ACB of 800 Amps capacity, S&F LT ACB with metal sheet enclosed pedestal type to house ACB 800 Amps 4 pole, manual draw out megnatic release breaker of capacity 50 KA complete all as specified and directed by Engr-in-Charge. Make-: Havells/Schnieder/Legrand
Earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 25 x 4 mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR1996 part 1 ,including necessary excavation and earth work in any strata of soil,common salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc complete all as specified and directed by Engr-in-Charge. Note:- (i) All the joints shall be made with welding to get proper conductivity. (ii) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-Charge
Supplying, laying, jointing and testing LT underground cable, heavy duty, XLPE insulated heavy duty electric cables with aluminium conductor 1100 volts grade, of size 10 sqmm 2 core laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts complete all as specified and directed by Engr-in-Charge. Make- Havells/Grandley/Polycab /Gloster
Supplying, laying, jointing and testing LT underground cable, heavy duty, XLPE insulated heavy duty electric cables with aluminium conductor 1100 volts grade,of size 16 sqmm 4 Core laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts complete all as specified and directed by Engr-in-charge. Make:- Havells/Grandley/Polycab/ Gloster
Supplying, laying, jointing and testing LT underground cable, heavy duty, XLPE insulated heavy duty electric cables with aluminium conductor 1100 volts grade of size 120 sqmm 3.5 core laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts complete all as specified and directed by Engr-in-charge. Make- Havells/Grandley/Polycab/ Gloster
Supplying, laying, jointing and testing LT underground cable, heavy duty, XLPE insulated heavy duty electric cables with aluminium conductor 1100 volts grade of size 150 sqmm 3.5 core laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts complete all as specified and directed by Engr-in-Charge. Make- Havells/Grandley/Polycab/ Gloster
Supplying, laying, jointing and testing LT underground cable, heavy duty, XLPE insulated heavy duty electric cables with aluminium conductor 1100 volts grade of size 185 sqmm 3.5 core laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts complete all as specified and directed by Engr-in-Charge. Make- Havells/Grandley/Polycab/ Gloster
Supplying, laying, jointing and testing LT underground cable, heavy duty, XLPE insulated heavy duty electric cables with aluminium conductor 1100 volts grade of size 240 sqmm 3.5 core laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts complete all as specified and directed by Engr-in-Charge. Make- Havells/Grandley/Polycab
Supplying, laying, jointing and testing LT underground cable, heavy duty, XLPE insulated heavy duty electric cables with aluminium conductor 1100 volts grade, of size 300 sqmm 3.5 core laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts complete all as specified and directed by Engr-in-Charge. Make- Havells/Grandley/Polycab/ Gloster
Supplying, laying, jointing and testing LT underground cable, heavy duty, XLPE insulated heavy duty electric cables with aluminium conductor 1100 volts grade, of size 95 sqmm 3.5 core laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts complete all as specified and directed by Engr-in-Charge. Make- Havells/Grandley/Polycab/ Gloster
1100 Volts grade heavy duty cable (in Replacement) PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed in service connections one twin core 10 sqmm cable flat or round complete all as specified and directed by Engr-in-Charge.
Excavation in trenches n exc 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of under ground cable and getting out in soft/ loose soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
DWC (Double wall corruguated) pipe 180 x 152 mm conforming to IS: 14930/ IS 16205 for protection of LT Cable of size 300sq.mm complete all as specified and directed by Engineer-in-Charge .
DWC (Double wall corruguated) pipe 120 x 103 mm conforming to IS: 14930/ IS 16205 for protection of LT Cable of size 240,185, 150 & 120sq.mm complete all as specified and directed byEengineer-in-Charge.
DWC (Double wall corruguated) pipe 40 x 32 mm conforming to IS: 14930/ IS 16205 for protection of LT Cable of size 10 and16 sq.mm complete all as specified and directed by Engr-in-Charge.
DWC (Double wall corruguated) pipe 90 x 76 mm conforming to IS: 14930/ IS 16205 for protection of LT Cable of size 95 sq.mm complete all as specified and directed by Engr-in-Charge.
Composite type PVC Spacer suitable for LT Conductor 3 phase, 50 Hz, 440 Volts suitable for temperature -5 degree to 50 degree, humidity should be 0 to 100%, wind pressure upto 150kg/M2. Sufficent strength shall be made for spacers at the points where grooves are made for holding the conductors. Color should be grey/White complete all as specified and directed by Engr-in-Charge. Make-:Pactil/Atlas/Raychem (RPG)/Jaipuria
LT change over switch Off load type, 200 Amps, 4 pole, 50 HZ, conforming to including taking down U/S change over switches complete all as specified and directed by Engr-in-Charge. Make:- Legrand/ L&T/Havells ,C&S,ABB
LT change over switch Off load type, 100 Amps, 4 pole, 50 HZ, conforming to including taking down U/S change over switches complete all as specified and directed by Engr-in-Charge. Make:- Legrand/ L&T/Havells ,C&S,ABB
D P ASSOCIATES
vijay kumar gupta and co
MOHAN LAL AND SONS
M/S A K ENGINEERS & CO.
proach associates
M/S RAJINDER GOODS TRANSPORT CARRIER
slathia construction works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .