Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR AND MAINTENANCE OF LT DISTRIBUTION SYSTEM, CONTROL SWITCHES GEAR, GARDEN LIGHTS, EXTERNAL ELECTRIFICATION, BR WORKS AND INTERNAL WATER SUPPLY FOR AMC RECORD PAO, 11 GRRC RECORD PAO, PCDA OFFICE, RTC AND VIVEK VIHAR UNDER GE E/M LUCKNOW
2023_MES_623624_1
GE/EM/LKO/EXT(ELECT)/T-52 OF 2023-2024
Open Tender
Civil Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹70,000
Yes
19 Jan 2024
17 Oct 2023
25 Nov 2023
17 Oct 2023
18 Nov 2023
1 Nov 2023
Amount
Demolition of brick work or stone / boulder masonry built in cement mortar or cement lime mortar including all quions, arches, pillars etc but excluding ashlar facings, dressed stone work and pre cast concrete articles all as directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving n. exc 15 cm thickness (below or above ground level).
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for.
M&L for brick work with sub class 'B' Bricks (using old size bricks) straight or curved on plan exc 6m mean radius, built in CM 1:6, complete all as specified and as directed.
M&L for 40 mm thick PCC type B-1, 1:2:4 (20 mm graded stone agg) as in flooring, finished even and smooth with using extra cement all as specified and as directed.
M&L for mild steel TMT bars (Fe-500) 8 mm dia, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binging with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified.
M&L for mild steel TMT bars (Fe-500) 10 mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binging with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified.
M&L for Pre cast RCC 1:2:4 type B1 using 20 mm graded stone aggregates as in cover slab for soakage well / manhole and similar works supported on walls and set in cement mortar 1:4 complete. Note:- Reinforcement steel will be measured & paid separately
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in coping, chajja, facia and the like including weathering, slightly rounded or chamfered angles with & incl necessary use and waste of form work for fair faces of concrete.
Supply only integral water proofing compound powder ISI marked
M&L for Mild steel work Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 as in small articles like angle iron framing work for manhole, rungs/steps in man hole
M&L for treating small articles of steel like MS rungs etc with coal tar black paint including preparation of surface, area tarred not exc 0.1 sqm each
Taking up or down 15 mm bore steel tubing and connections, from walls, floors or ceiling etc complete all as specified and as directed by Engineer-in-Charge.
Taking up or down 20 mm bore steel tubing and connections, from walls, floors or ceiling etc complete all as specified and as directed by Engineer-in-Charge.
Refixing of 15 mm bore old steel tubing and connections in new or old position on walls, ceiling or floors etc after cleaning including provn of new fittings all as directed by Engineer-in-Charge (using old steel tubing retrieved from item hereinbefore).
Refixing of 20 mm bore old steel tubing and connections in new or old position on walls, ceiling or floors etc after cleaning including provn of new fittings all as directed by Engineer-in-Charge (using old steel tubing retrieved from item hereinbefore).
S&F 15 mm bore tubes, 'medium grade', galvanised, with all fitting; (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) and fixed to wall / ceiling with clips, wall hooks, wooden plugs or laid in floors, complete all as specified.
S&F 20 mm bore tubes, 'medium grade', galvanised, with all fitting; (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) and fixed to wall / ceiling with clips, wall hooks, wooden plugs or laid in floors, complete all as specified.
Dismantling water tank capacity exc 250 & n.exc 500 litre and taken as credit
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt I. capacity of tank 500 litres.
Dismantling water tank capacity exc 500 & n.exc 1000 litre and taken as credit
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt I. capacity of tank 1000 litres
S&F 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball, screwed for iron pipe and fixed. .(Minimum weight 20mm-210gms) complete all as specified.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards / slabs / blankets, any thickness, including cover fillets & snap grid.
M & L for PVC Wall panelling / Lining consisting of 5 mm thick Plain / wood colour PVC sheet as approved inclusive of solvent cement and fixing at site on PVC frame complete fixing arrangements on wall complete all as per manufactures specifications.
S&F false ceiling of E-board of size 600 x 600 x 4 mm thick, white prelaminated seif embossed reinforced designer ceiling board tiles of approved texture at all height including snap grid for false ceiling of size 600 mm x 600 mm grid EXPOSED GRID SYSTEM fabricated with galvanised iron powder coated section all as shown on serial page No 185 of SSR part II (2020 print) complete all as specified directed by the Engineer-in-Charge
M&L for seamless ceiling comprising of Gypsum Board 12 mm thick in ceiling fixed with screw or as per manufacturers instructions, with necessary jointing and taping, and applying two coat oil bound distemper over one coat primer fixed over and including Gl frame work comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre, intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx. 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having knurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified & directed.
Taking down chowkhat or frame (wooden/aluminium) n. exc. 1.5 Sqm each with shutters (with out taking off shutters from the frame) and taken as credit all as specified and directed.
Taking down chowkhat or frames (wooden/aluminium) with shutters without taking off shutter from the frames exc. 1.5 but n. exc 4 sqm each all as specified and directed.
Taking down shutters of any description n exc 1 sq.m each complete all as specified.
Taking down shutters of any description exc 1 sq.m and n exc 2 sq.m each complete all as specified.
S&F Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, complete all as shown in drawing of relevant item in MES, schedule Part-II , 2020 as specified and as directed by Engineer-in-Charge.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as shown in drawing of relevant item in MES, schedule Part-II , 2020 as specified and as directed by Engineer-in-Charge.
S&F 250 mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete.
S&F 100 mm long aluminium anodized barrel tower bolts of extruded section complete.
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm fixed to wooden / steel joinery complete all as specified and directed.
S&F in repair galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm in steel window and wooden beading in wooden joinery complete all as specified and directed.
S & F in repair for 150 mm floor door stopper of aluminium alloy body and tonge,anodised with hard drawn steel spring
Hacking out old broken glass, any thickness, size, quality, or description, from frame n.exc 1.5 Sqm in each pane
S&F for 3.0 mm thick sheet glass ordinary quality and glazing with oil putty n.exc 0.5 Sqm each pane
S&F 3.0 mm thick figured glass ordinary quality and glazing with oil putty n.exc 0.5 Sqm each pane
S&F 4.8 mm thick sheet glass ordinary quality and glazing fixed to aluminium joinery with and including neoprene beading area of each pane exc 0.5 Sqm to 1 sqm.
S&F in repairs for 15 mm size bib taps, long body, fancy type, cast copper alloy chromium plated, with capstan head, screwed down, screwed for iron pipe or for brass ferrule and fixed, all as specified.
S&F in repair cast iron floor trap with chromium plated grating including jointing to waste pipe with cement mortar (75 mm bore of pipe).
S&F in repairs Brass chromium plated shower rose without swivel joints , any size, including fixing to steel pipe or union complete all as specified .
S&F in repair 15 mm size stop cock, cast copper alloy, chromium plated, fancy type with capstan head, with long shank and cup (concealed type) screwed down, screwed both end for iron pipes complete.
S&F in repairs for 15 mm size angle cock, chromium plated fancy type, cast copper alloy, screwed down, high pressure, with capstan head, screwed both ends for iron pipe or for unions and fixed, all as specified.
S&F in repairs 15 mm size Pillar taps, fancy type cast copper alloy, chromium plated with capstan heads, screwed down, high pressure, with or without lettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts, screwed for iron pipe.
S&F in repair 15 mm size PTMT( Polytetra Methylene Terephthalate ) Bib taps standard of PTMT any colour screwed, for iron pipe and fixed ( Minimum weight 15 mm-90 gms complete all as specified.
S&F in repairs for 15 mm size angle cock, two way, chromium plated fancy type, cast copper alloy, screwed down, high pressure, with capstan head, screwed both ends for iron pipe or for unions and fixed, all as specified.
S&F in repairs, 75 /100 mm dia stainless steel chromium plated grating, fixed in position with white cement Complete.
S&F in repairs white Vitreous China wash down water closet (pedestal pattern) with fixing bolt, Plastic water closet seat cover, white, closed pattern with flat bottom, and cover with aluminised hinging device, including all connection complete.
Supply and fix in repairs white vitreous China squatting pan ‘ORISSA’ pattern of size 580 mm x 440 mm white with integral foot rests with ‘P’ or ‘S’ trap, front or back inlet including all connection and provision of lime concrete base complete all as specified and as directed..
S&F in repair PVC low level flushing cistern, duel type, valveless, symphonic action type, double push bottom, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 32 mm dia of required length and making connection complete all as specified.
Supply and fix in repairs Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified.
S&F in repair PVC connection 15 mm size, of length 450 mm, with PTMT nuts complete all as specified and as directed by Engineer-in-Charge
S&F in repair vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm, white, with grating and union for discharge pipe (excluding flushing cistern, flush pipe), including waste pipe 32 mm size & 600 mm long flexible pipe with PVC coupling complete all as specified.
Supply and fix in repair white vitreous China wash hand basin (Flat back) of size 550 x 400 mm fixed on and including new brackets complete including, 32 mm size brass chromium plated waste coupling, chain and plug and porcelain stopper, waste pipe 32 mm size & 600 mm long flexible pipe with PVC coupling complete all as specified.
S&F in repairs 32 mm size waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly nuts, flange end and fixed complete all as specified fixed.
S&F in repairs 32 mm dia & 600 mm long, flexible PVC waste pipe fixed to WHB / urinals including PVC coupling complete all as specified.
S & F in repairs 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete.
S & F in repairs 15 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete.
M&L for Repairing of existing aluminium door single / double leaf (area of each leaf exc 1 Sqm but n.exc 2.0 Sqm) by taking down tightening of joint, tightening of top & bottom patch, replacement of cleat, screw, oiling and greasing of floor springs, & refixing in same opening for smooth functioning complete all as specified. Note:- Floor door springs where renewed shall be measured and paid separately under appropriate item of BOQ.
M&L for Repairing of existing toughened glass door single leaf (area of each leaf exc 1 Sqm but n.exc 2.0 Sqm) by taking down tightening of joint, tightening of top & bottom patch, oiling and greasing of floor springs, & refixing in same opening for smooth functioning complete all as specified. Note:- Floor door springs where renewed shall be measured and paid separately under appropriate item of BOQ.
S&F in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty.
S&F in repairs aluminium body (extruded section) body Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters 701 to 850 mm in width and of weight between 36 to 60 Kg and fixed complete.
S&F in repairs Mortise lock vertical type of mild steel 4 levers of size 100 mm with duplicate key all as specified.
Supply fabricate & fix in position aluminium joinery fabricated with Powder coated aluminium section (minimum thickness of powder coating 50 micron) for doors, windows, ventilators and partitions of any description with extruded, standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing in position with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides, Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, EPDM rubber / neoprene gasket etc complete all as directed by Engineer-in-Charge & all as specified. Note:- Hardware fitting, glazing & panelling will be measured & paid separately.
S&F 3 mm thick aluminium composite panel cut to size and fixed to aluminium frame and shutter in door as specified and directed by EIC
S&F 4.8 mm thick sheet glass ordinary quality and glazing fixed to aluminium joinery area of each pane exc 0.5 Sqm to 1 sqm.
S&F in repair aluminium partition fabricated with aluminium powder coated (minimum thickness of powder coating 50 micron) section for side & top rail of size 101 mm x 44 mm x 2.5 mm for middle rail (horizontal / vertical) of size 101 mm x 44 mm x 2.5 mm, partly glazed with 5 mm thick tinted glass and partly panelled with 3 mm thick aluminium campsite panel including glazing clip, rubber bead, fixed in position as standard practice complete all as directed by the Engineer-in-Charge.
S&F anodised aluminium grill weight not less than 3.13 Kg per sqm fixed with frame in existing windows / ventilator all as specified and as directed.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement including taking down old railing.
S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified.
M&L 30 mm thick 2nd class hard wood Glazed and Skelton shutter, open rebated and prepared to receive glass, gauge etc. divided into squares with plain chamfered or rounded, mitred and rebated sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.23(b) complete all as specified.
S&F 100mm size butt hinges medium weight (ISI Marked), rolled mild steel complete.
S&F 75mm size butt hinges medium weight (ISI Marked), rolled mild steel complete.
M&L for 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms, wash basin platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including half round moulding of exposed edge, laid over and including 15 mm thick screed in cement mortar 1:4 and dismantling of old stone slab complete all as specified
M&L for Coloured Glazed ceramic tiles of size 300 mm x 450 mm x 7 mm thick in vertical surface set and jointed in neat cement slurry and pointed in white or colour cement to match with tiles laid over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete.
S&F powder coated anodised Aluminium alloy sections sliding windows shutters with frames comprising Series -C (20mm), 3 track sliding shutters duly fitted with neoprene beading, glazing clips, locking device, heat absorbing glass 4.8 mm nominal thickness in 2 shutters and 0.46mm dia SS wire mesh in one shutter complete all as specified and as directed
S&F anodised Aluminium alloy sections for fixed windows shutters with frames of section weight not less than 0.55 Kg / rm, duly fitted with neoprene beading, glazing clips, locking device, heat absorbing glass 4.8 mm nominal thickness complete all as specified and as directed
Excavating in post holes each not exc. 0.5 cum getting out in soft / loose soil, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exc. 25 cm, watering and removing surplus soil to a distance not exc. 50 m and depositing where directed
M&L for PCC 1:4:8 type D-2 as in foundation and mass concrete using 40 mm graded stone.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
M&L for preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
Dismantling of roof sheet (any descriptions) including ridges in roof covering all as specified and directed.
S&F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified
S&F 2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with L type or J- type or cranked hook bolts and washers in roof, wall etc complete.
M&L for providing cement concrete type B-1, 1:2:4 ( 20 mm graded stone aggregate ) as in roof kerbs / padding or similar work or mud stops rounded or chamfered on edges.
S&F in repairs brass chromium plated Health faucet fixed with spring action and lever along with PVC flexible pipe 1.2 mtr for supply of water fitted in the existing water connection in the toilets, Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs overhead shower of 100 mm dia round shape single flow (ABS Body Chrome Plated with Gray Face Plate) with rubit cleaning system complete all as specified and as directed Make Jaquar cat No OHS-CHR-1989 or equivalent make mention in list of make.
S & F in repairs 15 mm size wall mixer with provision for hand shower, for mixing hot & cold water, cast copper alloy chromium plated with capstan heads, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repairs for 15 mm size bib taps, two way, fancy type, cast copper alloy chromium plated, with capstan head, screwed down, screwed for iron pipe or for brass ferrule and fixed, all as specified.
S&F in repairs single towel rail 600 mm long fixed in position complete. Make Jaquar cat No AKP-35711P or equivalent make mention in list of make.
Material and labour 1st quality vitrified outdoor, parking tiles of approved shade, of size 300 mm x 300 mm x 10 mm thick as in floors / path etc, set & jointed in neat cement slurry & pointed in matching coloured polymer cement based grout to match laid over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed.
M&L for 75 mm thick plain cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as in sub base complete all as specified and directed.
Taking down cement plaster of any description on brick or stone masonry wall , etc including racking out joints, hacking for key, scrubbing down with water etc, all as specified.
M&L for acrylic polymer-modified cementitious high performance coating (two component) with high solid content and can be used for both side waterproofing due to its excellent bonding, good waterproofing and unmatched resistance to hydrostatic pressure which resist up to 5 bars of positive hydrostatic pressure and form highly elastic film which provides elengation up to 100 as per manufactures instructions complete all as directed. Note:- Work shall be carried out by the authorised applicators of manufactures only.
M&L for Rendering 15 mm thick in cement and sand mortar 1:4 on brick work or cement concrete surfaces of walls including finishing the surface even and smooth with using extra cement and mixing only integral water proofing compound as per manufacturer instruction complete all as specified and as directed by Engineer-in-Charge. Note:- WPC will be measured and paid separately.
M&L for Rendering 10 mm thick in cement and sand mortar 1:6 on brick work or cement concrete wall surfaces including finishing the surface even and smooth without using extra cement complete all as specified.
M&L for Rendering 5 mm thick in cement and sand mortar 1:3 on concrete surfaces of ceiling, including finishing the surface even and smooth without using extra cement complete all as specified.
M&L for preparing new plastered surfaces of ceiling and applying three coats white wash all as specified and directed.
M&L for Preparation of newly plastered surfaces of walls and applying two coat of oil bound distemper over one coat of primer including 3 mm thick cement base wall care putty complete.
M&L for preparation of new plastered surface of walls and applying two coats exterior emulsion weather coat paint of make Apex (Asian Paint) / Weather coat (Berger) / Excel Top Guard (Nerolac) over one coat primer complete all as specified and directed.
M&L for Preparation of old painted wood and wood based surfaces of any description, not otherwise described over 10 cm width or girth, including knotting and stopping and applying one coat of synthetic enamel paint all as specified.
M&L for preparation of old decorated surface of wall and applying one coats of plastic emulsion paint interior quality any shade complete all as specified and directed by EIC.
M&L for Preparation of old decorated surfaces of walls by brooming down or steel wire brushing scraping down smoke soot, moulds moss and efflorescent salts, trading oil and greasy spots and applying one coat of white wash all as specified
M&L for Preparation of old decorated surfaces of ceiling by brooming down or steel wire brushing scraping down smoke soot, moulds moss and efflorescent salts, trading oil and greasy spots and applying one coat of white wash all as specified
M&L for Preparation of old decorated surfaces of walls by brooming down or steel wire brushing scraping down smoke soot, moulds moss and efflorescent salts, trading oil and greasy spots and applying one coat of cement base paint of any tint / shade all as specified.
M&L for Preparation of old decorated surfaces of walls by brooming down or steel wire brushing scraping down smoke soot, moulds moss and efflorescent salts, trading oil and greasy spots and applying two coats of cement base paint of any tint / shade all as specified.
M&L for Preparation of old decorated surfaces of walls by brooming down or steel wire brushing scraping down smoke soot, moulds moss and efflorescent salts, trading oil and greasy spots and applying one coat of distemper oil emulsion of any tint / shade all as specified.
M&L for Preparation of old decorated surfaces of walls by brooming down or steel wire brushing scraping down smoke soot, moulds moss and efflorescent salts, trading oil and greasy spots and applying two coats of distemper oil emulsion of any tint / shade all as specified.
M&L for Preparation of old decorated surfaces of ceiling by brooming down or steel wire brushing scraping down smoke soot, moulds moss and efflorescent salts, trading oil and greasy spots and applying two coats of distemper oil emulsion of any tint / shade all as specified.
M&L for Preparation of old painted surfaces of steel of any description, not otherwise described over 10 cm width or girth, and applying one coat of synthetic enamel paint all as specified.
M&L for complete removal of existing treatment of walls and applying two coats of distemper oil emulsion over a coat primer including applying 2 mm thick cement base wall putty complete all as specified and directed.
M&L for preparation of painted brick, stone, concrete, AC or plastered surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed
M&L preparation of old painted surface of walls and applying one coat exterior emulsion weather coat paint of Apex (Asian Paint) / Weather coat (Berger) / Excel Top Guard (Nerolac) complete all as specified and directed.
M&L for Brick work with sub class 'B" (using old size bricks) straight or curved of on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified.
S&F steel work in tubular trusses / posts including special washers etc complete using ERW or induction butt welded tubes conforming to I.S. 1161-1998 grade St-240 complete all as specified & directed.
S&F rolled mild steel section as in main and cross beams, hip and jack rafters; purlin where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe 410-W (Gde-E-250 quality A).
M&L for 75 mm thick PCC type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in plinth protection laid in bays n. exc. 2 sqm each, finishing the surface of concrete topping even & fair, without using extra cement filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight) complete all as specified and as directed by Engineer-in-Charge.
M&L for 18-20 mm thick machine cut Kota stone slab flooring with marble stone strips / slab / tiles as per design approved, over and including cement screed bed 20 mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified.
M&L for 18-20 mm thick machine cut Kota stone slab as in skirting / riser over cement screed bed 10mm thick in CM 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified.
Grinding of old Kota stone flooring up to mirror finish level including polishing etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding and rubbish off the premises complete.
M&L for non skid ceramic tiles of 7-8 mm (square or rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles laid over and including 15 mm thick screed in CM 1:6 (Note : Screed bed will not be measured and paid separately)
M&L for Vitrified ceramic tiles 10 mm thick (square/rectangular) Coloured polished tiles, area of each tile n.exc 0.38 sq m in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement and pigment to match laid over and including 15 mm thick screeding in CM 1:6 (Note : Screed bed will not be measured and paid separately)
Demolition of existing roof treatment of any type
M&L for 15 mm thick screed plaster on RCC slab in CM 1:4 including mixing only water proofing compound complete.( WPC to be measured and paid separately)
M&L for water proofing treatment on roof surfaces in the following manner:- (a) The surfaces shall be painted with hot bitumen grade 30/40 confirming to IS-73 @ 1.20 kg / sqm over a coat of bituminous primer conforming to IS-3384 @ 0.30 litre /sqm. (b) Supply & lay 3 mm thick APP water proofing membrane reinforced with non woven polyester matt laid using butane torch by torch application with a side lap of 10 cm & 15 cm end lap weighing not less than 3.5 kg / sqm. Note: - (i) Work to be carried out through authorised applicators of the manufactures and work will be carried out in complete / in patches in roofs (ii) Contractor shall submit written guarantee of 10 years from date of completion & submit security deposit @ 2.5% of executed amount or Rs 6250.00 which ever is more.
M&L for applying two coats of aluminium paint over APP membrane including preparation of surfaces and primer.
M&L for 40 mm thick brick tiles laid over and including 15 mm thick cement mortar in 1:6 and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement.
Taking down PVC SWR pipes (any sizes) incl all fittings
S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, or fixed to wall
M&L for Chequered cement concrete coloured tiles 30 cm x 30 cm x 20 mm thick with white cement and pigment, set, jointed and pointed in neat cement slurry laid over and including 15 mm thick screed bed in CM 1:6 as in floors complete all as specified.( (Note : Screed bed will not be measured and paid separately)
M&L for French polishing on wooden surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats complete all as specified and directed
M&L for applying two coats of synthetic varnish over old wooden surfaces including preparation of surfaces complete all as specified and directed
S&F corner sheet glass shelf of 4.8 mm thick fixed with Stainless steel clamps and other necessary fittings suitable for holding in wall corner with minimum 200 mm length in front circular shape, complete all as specified and directed by Engineer-in-Charge.
S&F for sheet glass shelf of 4.8 mm thick fixed with Stainless steel clamps and other necessary fittings suitable for holding in wall of minimum size 300 x 150 mm, complete all as specified and directed by Engineer-in-Charge.
S&F False ceiling, with and including GI powder coated frame work and mineral fibre ceiling tiles , suspended with ceiling, complete all as specified and directed by Engineer-in-Charge. Make : Dune Max RH 99 of Arm strong or Everest or any other make as specified in Annexure of Makes.
Temporarily blocking of inlet of septic tanks/manhole with suitable wooden plugs/gunny bags and pumping/bailing out effluent and taking out/removing the accumulated sludge soil sewage/any other foreign/foul materials etc (solid/semisolid) from the septic tanks/manholes. complete and cleaning the septic tank/manholes with water by mechanically/manually including taking out the blocking arrangements of inlet and making the system functional all as specified and directed by E-I-C (NOTE: Depth of manhole/SOAK WELL/SEPTIC TANK exc 0.5 to 1.5M from below GL)
Temporarily blocking of inlet of septic tanks/manhole with suitable wooden plugs/gunny bags and pumping/bailing out effluent and taking out/removing the accumulated sludge soil sewage/any other foreign/foul materials etc (solid/semisolid) from the septic tanks/manholes. complete and cleaning the septic tank/manholes with water by mechanically/manually including taking out the blocking arrangements of inlet and making the system functional all as specified and directed by E-I-C (NOTE: Depth of manhole/SOAK WELL/SEPTIC TANK exc 1.50M to 4.50M from below GL)
Temporarily blocking of 150 mm bore sewage line with suitable wooden plugs/gunny bags and cleaning the same by rod-ding and removing the sludge alongwith brick bats/stones/broken bottles/any other foreign materials etc complete and cleaning the sewage line with water by mannually/mechanilly as directed by EIC, and taking out the blocking arrangements of inlet and making the system functional all as specified and directed
Temporarily blocking of 200 mm bore sewage line with suitable wooden plugs/gunny bags and cleaning the same by rod-ding and removing the sludge alongwith brick bats/stones/broken bottles/any other foreign materials etc complete and cleaning the sewage line with water by mannually/mechanilly as directed by EIC, and taking out the blocking arrangements of inlet and making the system functional all as specified and directed
Temporarily blocking of 250 mm bore sewage line with suitable wooden plugs/gunny bags and cleaning the same by rod-ding and removing the sludge alongwith brick bats/stones/broken bottles/any other foreign materials etc complete and cleaning the sewage line with water by mannually/mechanilly as directed by EIC, and taking out the blocking arrangements of inlet and making the system functional all as specified and directed
M&L for 150 mm bore SGSW drain pipe (Grade-A) laid in trenches and jointed in CM 1:1 and tested complete all as specified and directed.
S & F in repair white vitreous China floor mounted coupled EWC of size 380 mm x 725 mm x 690 mm including UF soft close slim seat cover, hinges, fixing accessories, accessories set and Cistern Fittings complete all as specified and directed. Make of Cistern & EWC: Jaquar model No-ONS-WHT-10853S300UFSM or equivalent cat No of make mention in list of make
M&L for precast cement concrete Type B0,1:2:4 (using 12.5 mm graded stone aggregates) louvres and jallies, 25 mm thick (measured solid), including all mouldings and set in CM 1:4 complete all as specified and directed
S&F chromium plated towel ring of circular / oval / rectangular shape with fixing arrangement complete fixed on walls.
M&L for Pressed steel frames of size 125 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, lock strike plates complete, providing mild steel 6 mm dia thresh old bar, thickness of sheet 1.25 mm and filling hollow of frame with plain cement concrete Type C-0, 1:3:6 (using 12.5 mm graded crushed stone aggregate) complete, all as specified.
M&L for Pressed steel frames of size 105 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, lock strike plates complete, providing mild steel 6 mm dia thresh old bar, thickness of sheet 1.25 mm and filling hollow of frame with plain cement concrete Type C-0, 1:3:6 (using 12.5 mm graded crushed stone aggregate) complete, all as specified.
Taking down old unserviceable concealed conduit point wiring aluminium / copper i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, bell push, ceiling rose, pendants, holders, etc all as required and directed by Engineer-in-Charge.
Material & Labour for concealed point wiring for one light / Fan point / bell point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including surface type caping & casing not less than 25 mm wide, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable of green colour as a earth wire connected to common earth dolly, etc including pressed steel terminal box of suitable size with laminated white top sheet cover of 3.00 mm thick including placeing the conduit in same chases obtained after taking down old wiring and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris / Putti & distemper with same existing colour surfaces all as specified and directed by Engineer-in-Charge.
All as per Item No 157 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch.
All as per Item No 157 above but for one 5 pin 5 Amp socket outlet point on an independent board.
All as per Item No 157 above but for One 3 pin 6 / 5 Amp socket outlet controlled by one switch on independent board but below / side the switch board of light point in same vertical / horzintal plane.
All as per Item No 157 above but for power point wiring with 4.0 Sqmm FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 4.0 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
S&F switch piano flush type, single pole, one way 6 Amp, 240 Volts complete all as specified and as directed.
S&F bell push piano flush type, single pole, one way 6 Amp, 240 Volts complete all as specified and as directed.
S&F switch piano flush type, single pole, one way 15 /16 Amps, 240 Volts complete all as specified and as directed.
S&F socket outlet flush type multipurpose 2 in 1, 5 pin 6 Amp, 230 volts complete as directed.
S&F socket outlet, 2 in 1, 3 / 5 pin, 6 / 16 Amp, piano flush type complete all as specified and as directed
S&F ceiling rose, surface type polycarbonate body, 65mm x 17 mm, three terminals complete all as specified and as directed.
S&F batten angle lamp holder insulated body with back plate suitable for batten fittings complete all as specified and as directed.
S&F in repair Ding dong sound door call bell electric AC 240 volt, 50 Hz including taking down unserviceable complete all as specified and as directed.
Supply & fix step type fan regulator 80 Watt, 240 Volt AC, flush type complete all as specified and directed.
Material & Labour for concealed sub main wiring with 2 run single core multistranded copper conductor cable, of size 4.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke, drawn through and including heavy duty rigid PVC conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire in green colour, fixed on wall / ceiling, including taking down old sub main wiring complete. Note: (i) 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment.
Material & Labour for concealed sub main wiring with 2 run single core multistranded copper conductor cable, of size 6.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke, drawn through and including heavy duty rigid PVC conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire in green colour, fixed on wall / ceiling, including taking down old sub main wiring complete. Note: (i) 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment.
S&F service connection with twin core 6 Sqmm 240 volt heavy duty un armured PVC insulated, solid aluminium conductor cable, served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than one metre apart including 4 mm GI supporting wire of suitable size in replacement of old unseriveable conductor cable complete.
S&F service connection with twin core 10 Sqmm 240 volt heavy duty un armured PVC insulated, solid aluminium conductor cable, served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than one metre apart including 4 mm GI supporting wire of suitable size in replacement of old unseriveable conductor cable complete.
S&F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, fixed flush to wall complete all as specified and directed.
S&F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 12 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, fixed flush to wall complete all as specified and directed.
S&F in repairs VTPN distribution board, 4 way double door suitable for incommer 4 pole MCCB, 415 V & SP / TP MCB as outgoing, 200 Amps rated Busbar, inter connection link, cable ties, earth bar etc incl necessary civil works and electrical connections with suitable lugs / spreader links complete all as specified and directed by Engr-in-charge. Note: MCCB & MCB to be measured and paid separately.
S&F MCCB 125 Amps 415 volts, 4 pole 16 KA breaking capacity, with fixed thermal magnetic release, fixed in DB and connecting complete as directed.
S&F in repairs MCCB 100 Amps 415 volts, 4 pole 16 KA breaking capacity, with fixed thermal magnetic release, fixed in DB and connecting complete as directed.
S&F MCB, single pole 6 to 32 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB, single pole & neutral 6 to 32 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB, triple pole & neutral 63 Amp, 415 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
Supply and fixing four pole Isolator 100 Amps.
S&F in replacement PVC gang box fitted with and including piano type switch 15 A and socket 15 A, 230 Volts complete with pvc gitties and screws all as specified and as directed.
S&F in repair Modular white frame 2 module all as specified and as directed.
S&F in repair Modular white frame 4 module all as specified and as directed.
S&F in repair Modular white frame 6 module all as specified and as directed.
Supply and fix in repair metallic top 15 Amps, 3 pint type for AC
Supply and fix wall / surface mounting luminaires integrated LED Batten (4 feet) 20 W, 6500 K, 230V , system efficiency not les than 100 lumens / watt, with extruded aluminium housing with frosted PMMA / PC diffuser & integrated electronic driver fixed in position and connecting with ceiling rose complete all as per specified and directed by Engr-in-charge.
S&F in repair LED Building security light 35 Watt with high power LED source, system efficency not less than 110 lumen / watt), aluminium die casted housing, built in electronic driver, IP65 and IK 07 with 4 KV inbuilt surge protection including electrical connection with PVC three core copper conductor cable of size 1.5 sqmm, & all necessary fixing accessories, all as specified and directed by Engr-in-charge.
Supply and fix in repair LED lamp 10 watt, CDL, B-22 cap, 230V, PF-0.95 (min) including taking out unsv CFL / LED lamp complete all as per specified and directed by Engr-in-charge.
Supply and fix in repair LED lamp 15 watt, CDL, B-22 cap, 230V, PF-0.95 (min) including taking out unsv CFL / LED lamp complete all as per specified and directed by Engr-in-charge.
Supply and fix in true verticle position steel tubular swaged pole type 410 SP - 31 (9 mtr long) complete with MS base plate of size 300 x 300 x 6 mm thick at bottom, welded at the centre with through hole of 14 mm dia at a height of 300mm above the coping finial cap and painted with two coats of aluminium paint over a coat of red oxide primer with writing pole number including excavation upto required depth, PCC foundation type C-2, 1:3:6 (using 40 mm graded stone aggregate) at bottom and PCC type B-1 1:2:4 ( 20 mm graded stone aggregate) for pole coping (60 x 60 x 30 cm) and rendering of coping with 5 mm thick 1:6 cement mortar, including taking down old pole complete all as specified and directed.
S&F 80 mm dia bore mild steel galvanized iron tubes, 'light grade' with all fitting and laid in trenches or fixed to pole or laid in floors for protection of cable including taking down old pipe complete all as directed
S&F 40 mm dia bore mild steel galvanized iron tubes, 'light grade' with all fitting and laid in trenches or fixed to pole or laid in floors for protection of cable including taking down old pipe complete all as directed
S&F 50 mm dia bore mild steel galvanized iron tubes, 'light grade' with all fitting and laid in trenches or fixed to pole or laid in floors for protection of cable including taking down old pipe complete all as directed
M&L for Preparation of old painted surfaces of LT steel tubular pole 9 / 11 mtrs long and applying one coat aluminium paint from bottom to top including re writing pole numbering in 8 cm height with one coat synthetic enamel paint complete all as specified & directed by Engineer –in-Charge.
Supply and fix in replacement of 60 W LED Street light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant, lens for better distribution and toughened glass fixed to housing with screws, street light should have IP 66 protection and impact resistance of IK 07, system lumen efficiency not less than 110 lumen per watt, power factor >0.95, THD<10% at full load CRI> 70%, street light should have built in potted driver, THD, open circuit protection, over voltage protection, surge voltage protection, 10 KV surge protection divice, and provided with company LOGO ingraved on housing of the Street light including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement .
Supply and fixing in replacement of 90 W LED Street light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing with screws , street light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 110>_ lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted Driver THD, open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD , and provided with company LOGO ingraved on housing of the Street light complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement . .
Supply and fixing in replacement of 45 W LED Street light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing with screws , street light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 110>_ lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted Driver THD, open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD , and provided with company LOGO ingraved on housing of the Street light complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement . .
Supply and fixing in replacement of 120 W LED Street light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing with screws , street light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 110>_ lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted Driver THD, open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD , and provided with company LOGO ingraved on housing of the Street light complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement . .
Supply and fix in repair 10 / 12 LED bollard light fitting 60 cm long, having epoxy powder coated pressure die cast aluminium housing Light optic, high impact polycarbonate diffuser, colour temprature 5700K, CRi>70, THD<10% PF >.90 surge protection 4 KV inbuilt, rated voltage and frequency 240 Volt, 50 Hz, aesthetic innovative design with uniformly lit diffuser at the upper portion acts a beacon of path guidance in a landsscape IP 65 environmental with PCC 1:3:6 as in foundation work nut, bolt and washer etc complete all as specified and directed by Engr in Charge.
S&F in repair 40 watt LED Post top light fitting, energy saving, 240V, 50Hz AC, environmental friendly, aesthetically designed electronic constant current, IK07, having epoxy powder coated pressure die cast aluminium housing top cover spun aluminium sheet powder coated, front cover clear acrylic diffuser with indirect symmetrical light distributio, IP-65 luminaire with high power LED as light source, 5700K, PF >0.9, THD<10% and light efficiency 85> , CRI > 70, Surge protection 5KV, fixed over existing post, all as specified and directed.
Supply and fix security light bracket made out of galvanised steel light grade pipe of 40 mm dia, 1.5 metre long bend to an angle of 120 degree with 02 Nos clamp made out of 50 mm x 5 mm flat iron and 06 sets of nuts, bolts and washers, painting with two coats of synthetic enamel paint over a coat of red oxide primer, including taking down old bracket complete all as specified and directed.
Supply and fixing street light junction box of suitable size for three phase cable connection outdoor type, weather proof, factory made out of SMC 1.8 mm thick with front side hinged opening having locking arrangement with nuts & bolts & arrangement for incoming and out going cable / wire complete comprising with the followings :- (a) Bus bar with four aluminium strips, 100 Amps capacity insulated with insulators, including colour coding strip, including PVC cable of suitable size from bus bar to MCB (b) MCB SPN 5 to 30 Amps - 01 No (c) Clamps made out of 40 mm x 5 mm flat iron duly welded with nuts & bolts, including taking down old and unsv, complete all as specified and directed.
Supply and fix electonic driver constant current, sutable for 45 to 95 watt LED street light / flood light fitting fixed in fitting, connecting & testing including taking out old driver complete all as specified and directed.
Supply and fix electonic driver constant current, sutable for 120 to 150 watt LED street light / flood light fitting fixed in fitting, connecting & testing including taking out old driver complete all as specified and directed.
Supply and fix electonic driver constant current, sutable for 200 watt LED street light / flood light fitting fixed in fitting, connecting & testing including taking out old driver complete all as specified and directed.
S&F in repair PVC insulated, PVC sheathed, twin core 4 Sqmm aluminium stranded conductor cable 1100 volts grade, from junction box to street / security light all as specified and directed.
Supplying and laying or fixing, jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip armoured, ISI-7098, with aluminium conductor multi stranded, heavy duty 1100 Volts grade, cross sectional area 16 Sqmm, 4 core complete all as specified and directed.
Taking down ceiling fan of any size and any sweep & refixing the same after repairing & rectification of deffects complete all as directed by Engineer-in-Charge. Note:- Repairing & rectification of deffect will be measured & paid seperatly.
Taking down exhaust fan / wall fan of any size and any sweep & refixing the same after repairing & rectification of deffects complete all as directed by Engineer-in-Charge. Note:- Repairing & rectification of deffect will be measured & paid seperatly.
M&L for overhauling of ceiling fan of any make and sweep including dismantling, cleaning internally and externally, oiling, greasing, checking of electric connections, replacement of worn out check nuts, split pins, nuts, bolts and washers, rebber real, clamps and minor repairing works and items etc. reassembling and testing on completion all as directed.
M&L for overhauling of exhaust fan / wall fan / fresh air fan of any make and sweep including dismantling, cleaning internally and externally, oiling, greasing, checking of electric connections, replacement of worn out check nuts, split pins, nuts, bolts and washers, rebber real, clamps and minor repairing works and items etc. reassembling and testing on completion all as directed.
M & L for rewinding of ceiling fan 1400 mm sweep of any make by dismantling the ceiling fan, removing the burnt winding, cleaning slot, replacement of defective nut bolts washer etc and rewinding with using appropriate size of super enamelled copper winding wire thermal class-E, including varnishing and reassembling and testing complete all as directed by the Engineer-in-Charge
M & L for rewinding of exhaust fan 300 mm sweep of any make by dismantling the ceiling fan, removing the burnt winding, cleaning slot, replacement of defective nut bolts washer etc and rewinding with using appropriate size of super enamelled copper winding wire thermal class-E, including varnishing and reassembling and testing complete all as directed by the Engineer-in-Charge
M & L for rewinding of exhaust fan 250 mm sweep of any make by dismantling the ceiling fan, removing the burnt winding, cleaning slot, replacement of defective nut bolts washer etc and rewinding with using appropriate size of super enamelled copper winding wire thermal class-E, including varnishing and reassembling and testing complete all as directed by the Engineer-in-Charge
M & L for rewinding of wall fan 300 / 350 mm sweep of any make by dismantling the ceiling fan, removing the burnt winding, cleaning slot, replacement of defective nut bolts washer etc and rewinding with using appropriate size of super enamelled copper winding wire thermal class-E, including varnishing and reassembling and testing complete all as directed by the Engineer-in-Charge
S&F in repair ball bearing of size 6201ZZ fixed to ceiling fan / exhaust fan / of any type all as directed.
S&F in repair ball bearing of size 6202 ZZ fixed to ceiling fan / exhaust fan / of any type all as directed.
S&F in repair ball bearing of size 6203 ZZ fixed to ceiling fan / exhaust fan / of any type all as directed.
S&F in repair condensor 2.5 MFD fixed & connecting to fan any type all as directed.
S&F in repair condensor 4.0 MFD fixed & connecting to fan any type all as directed.
S&F in repair Gun metal bush for ceiling fan or exhaust fan all as directed.
S&F in repair down road 600 mm long suitable for any make of ceiling fans fixed in position all as directed.
M&L for providing dry river sand as in sand cushioning to under ground cable of any descreption including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: for measurement purpose any punned thickness of sand will be considered.)
M&L for well burnt brick sub class B old size laying in trenches perpendicular to axis of the cable complete all as specified and directed.
Deployment of manpowe / tools for Boring / drilling (Horizontly) manually / mechanically under existing road max 10 M in width) suitable for passing tubing 40 to 100 mm bore complete all as specified and directed by Engineer in Charge
Supply, laying jointing and testing LT UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, confirming to IS 7098 marked, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 core, laid in trench / laid under floor or fixed naked with wall / on wall / in ducts / in GI pipes etc. with and includings MS Clamps, nuts, bolts, washers including taking down old cable complete all as specified and directed. Note- Excation, earth works,and sand cushioning, protection bricks / tiles / blocks and pipe will be measured and paid seprately.
-- do-- as per item no. 229 above but LT UG cable of size 35 sqmm 3.5 core.
-- do-- as per item no. 229 above but LT UG cable of size 95 sqmm 3.5 core.
-- do-- as per item no. 229 above but LT UG cable of size 70 sqmm 3.5 core.
-- do-- as per item no. 229 above but LT UG cable of size 16 sqmm 4 core.
-- do-- as per item no. 229 above but LT UG cable of size 10 sqmm 2 core.
Supply and fix street light controll panel three phase for 6 KW load with Astronomical digital timer and MCB of capacity TP 32 Amps (01 No) and SPN 40 Amps (01 No) fixed on wall / pole with clamps nut bolts including taking down old panel complete all as specified and directed by Engr in Charge.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc, n exc 10 Sqm on plan area and getting out in hard / dense soil.
Removing excavated soil to a distance n.exc. 50 m and depositing where directed at a level of n.exc 1.5 m above the starting point complete all as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick using excavated soil complete all as directed.
S&F 15 mm bore mild steel galvanised tubing, medium grade, ISI Marked conforming to IS 1239 Part-I, with and including all fittings such as bends, elbows, tees, short length, socket, union, check nuts, nipples etc. fixed to walls / laid on floor etc, including dismentling taking down old unserviceable tubing complete all as specified and directed.
All as per item serial No. 239 here-in-before but of size 20 mm bore tubing.
S&F 25 mm bore mild steel galvanised tubing, medium grade, ISI Marked conforming to IS 1239 Part-I, with and including all fittings such as bends, elbows, tees, short length, socket, union, check nuts, nipples etc. laid in trenches etc, including dismentling taking down old unserviceable tubing complete all as specified and directed. Note: Exacavation and earhwork shall be measured and paid for separately.
All as per item serial No. 241 here-in-before but of size 40 mm bore tubing
All as per item serial No. 241 here-in-before but of size 50 mm bore tubing
All as per item serial No. 241 here-in-before but of size 80 mm bore tubing
All as per item serial No. 241 here-in-before but of size 100 mm bore, including suitable size MS flanges for pipe line, Joints and jointing materials shall be included under this item.
S&F 15 mm size Bronze gate valve, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778 : 1984, including dismentling taking down old unserviceable valve complete all as specified and directed.
All as per item serial No. 246.00 here-in-before but gate valve of size 20 mm.
All as per item serial No. 246.00 here-in-before but gate valve of size 25 mm.
All as per item serial No. 246.00 here-in-before but gate valve of size 40 mm.
Supply and fix in repair 20 watt LED tube rod, with ultra bright crystal light, 6000 K with high efficiency, internal electronic driver, fixed to existing battens complete all as directed.
Supply and fix in repairs recess type 36 watt LED light fittings of size 600 mm x 600 mm, made of CRCA powder quoted housing, fully covered by PMMA acrylic Lumio Diffuser, LED Used shall be SMD type, fixed in 15 feet hight false ceiling of any pattern / material, including electrical connection all as specified and directed.
M&L for renewal of earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal / coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. Note : Earthing lead / G.I.Earth wire with protection pipe upto 7.5 metre length shall be deemed to be included in quoted unit rate.
Supply and fix storage type water heater 5 star BEE rating, 25 liters capacity vertical wall mounting type made out of CRCA outer body, stainless steel storage tank, titanium enameled heating element, thermostat, thermal cutout, glass wool, including PVC connections 15 mm dia 450 mm long for hot and cold water, 3 core copper cable with plug top 15 Amp AC 230 V, fixing on existing wall with fastners-04 Nos including bolts washers etc and making good disturbed surface. & writing the MES No etc complete as specified and directed by EIC .
S&F ceiling fan 1200 mm sweep, BLDC copper wound motor, AC single phase, 230 volts, white colour complete with fan blade, down rod, canopy and provn of connection with three core flexible copper wire cable of size 1.50 Sqmm from ceiling rose to fan, writing of MES Nos as approved size of letter complete all as specified and directed.
Supply & fix exhaust fan metal body 300 mm sweep, 900 RPM, copper bound motor, AC 230 volts, single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including making hole in the wall, making good disturbed surface, writing of MES Nos as approved size of letter complete all as specified and directed.
S&F Cable jointing kit for straight through joint, heat shrink type joint for 1100 V grade cable complete with jointing material and accessories suitable for 3.5 core 25 to 50 sqmm XLPE armoured aluminium conductor cable.
S&F Cable jointing kit for straight through joint, heat shrink type joint for 1100 V grade cable complete with jointing material and accessories suitable for 3.5 core 70 to 95 sqmm XLPE armoured aluminium conductor cable.
S&F Cable jointing kit for straight through joint, heat shrink type joint for 1100 V grade cable complete with jointing material and accessories suitable for 3.5 core 120 to 150 sqmm XLPE armoured aluminium conductor cable.
S&F Cable jointing kit for straight through joint, heat shrink type joint for 1100 V grade cable complete with jointing material and accessories suitable for 3.5 core 185 to 240 sqmm XLPE armoured aluminium conductor cable.
Disconnecting all existing electric connection from panel taking out unserviceable MCCB and cable from LT panel Board and fixing connecting and testing of new MCCB 63 Amps 3 pole 25 KA, 415 Volt 50 Hz with spreader with suitable size of cable lugs / thimble complete including all electric connection, making good, all as specified and directed by Engr in charge.
Disconnecting all existing electric connection from panel taking out unserviceable MCCB and cable from LT panel Board and fixing connecting and testing of new MCCB 100 Amps 4 pole 25 KA, 415 Volt 50 Hz with spreader with suitable size of cable lugs / thimble complete including all electric connection, making good, all as specified and directed by Engr in charge.
Disconnecting all existing electric connection from panel taking out unserviceable MCCB and cable from LT panel Board and fixing connecting and testing of new MCCB 125 Amps 4 pole 25 KA, 415 Volt 50 Hz with spreader with suitable size of cable lugs / thimble complete including all electric connection, making good, all as specified and directed by Engr in charge.
Disconnecting all existing electric connection from panel taking out unserviceable MCCB and cable from LT panel Board and fixing connecting and testing of new MCCB 250 Amps 4 pole 25 KA, 415 Volt 50 Hz with spreader with suitable size of cable lugs / thimble complete including all electric connection, making good, all as specified and directed by Engr in charge.
Disconnecting all existing electric connection from panel taking out unserviceable MCCB and cable from LT panel Board and fixing connecting and testing of new MCCB 400 Amps 4 pole 25 KA, 415 Volt 50 Hz with spreader with suitable size of cable lugs / thimble complete including all electric connection, making good, all as specified and directed by Engr in charge.
Disconnecting / unscrewing coupling for 7.50 to 10 HP pump set and seperating pump and motor, disconnecting all water connections from pump including suction and discharge pipe line and taking out the pump from base frame, transporting to workshop to carry out the necessary repairs and took back after repairs , installing on existing location making all the connections carefully, commissioning and testing at site to the entire satisfaction of the Engr-in-Charge. Note: All the Spares/ parts/ job repairs required to be replaced shall be measured and paid seperately as under :-
S&F in replacement of coupling set suitable for 7.5 to 10 HP Pump set.
S&F in replacement of gun metal impeller suitable for 7.5 to 10 HP Pump set.
S&F in replacement of gun metal Bush suitable for 7.5 to 10 HP Pump set.
S&F in replacement of Gland Sleeve suitable for 7.5 to 10 HP Pump set.
S&F in replacement of body Neck ring gun metal suitable for 7.5 to 10 HP Pump set.
S&F in replacement of Pump shaft stainless steel suitable for 7.5 to 10 HP Pump set.
S&F in replacement of Counter Plate stainless steel suitable for 7.5 to 10 HP Pump set.
S&F in replacement of Diffuser Packing suitable for 7.5 to 10 HP Pump set.
S&F in replacement of Impeller brazing machining and reboring suitable for 7.5 to 10 HP Pump set.
S&F in replacement of New Key way of impeller disc suitable for 7.5 to 10 HP Pump set.
S&F in replacement of Diffuser outer dia brazing and machining suitable for 7.5 to 10 HP Pump set.
Supply, installing, testing and commissioning of factory made, CPRI approved powder coated LT Panel board, cubical compartmentalized, out door type, double door, plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain / SMC insulator. The panel shall be dust and vermin proof IP-54 class protection and outer shell made of of 3.15 mm CRCA MS sheet, inner shell made of 2.0 mm thick CRCA MS sheet , 50 x 50 x 6 mm size MS angle iron frame work, the cubical have bottom channel of size 75 x 40 mm x 6 mm, duly coated with zink metal coating, front and rear opening type, with apron for cable entry closing locking arrangement and comprising of the following :- (a) Incoming :- ACB 4 pole, 1000 Amp, 50 KA, 415 Volt AC Horizontal draw out type motorized, front operated for adjustable over current, short circuit and earth fault protection - 01 No.
M/S S.B. Singh and Sons
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .