Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹21.0 L+₹1.1 L (5.35%)Rejected-Finance | L2 | Rejected-Finance Not L1 bidder | |
| 3 | L3₹21.2 L+₹1.2 L (6.20%)Rejected-Finance | L3 | Rejected-Finance Not L1 bidder | |
| 4 | L4₹21.6 L+₹1.7 L (8.33%)Rejected-Finance | L4 | Rejected-Finance Not L1 bidder | |
| 5 | L5₹22.5 L+₹2.5 L (12.7%)Rejected-Finance | L5 | Rejected-Finance Not L1 bidder |
Tender Value
Refer Docs
EMD Value
₹47,000
Closing Date
24 Jul 2021, 6:00 pmClosed
GARRISON ENGINEER CENTRAL BANGALORE
MILITARY ENGINEER SERVICES GARRISON ENGINEER CENTRAL AGRAM POST BANGALORE 560007
SPECIAL REPAIR TO BUILDING NO ENP 227 OF MT WING, PROVISION OF UG CABLE AND PANEL BOARD AT AEPTA OF ASC CENTRE SOUTH AND PROVISION OF EXHAUST FAN IN BUILDING NO P 76 OF ASC CENTRE AND COLLEGE UNDER GE CENTRAL BANGALORE
2021_MES_454637_1
8141E
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER CENTRAL BANGALORE
₹47,000
Yes
27 Sept 2021
25 Jun 2021
26 Jul 2021
25 Jun 2021
24 Jul 2021
10 Jul 2021
25 Jun 2021 - 9 Jul 2021
Amount
B/R PORTION/WORKS : Dismantling of Asbestos Cement Corrugated or Semi-corrugated sheeting, any gauge, thickness, in roof covering including ridges complete as directed. (measured flat overall)
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing debris outside MD landcomplete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposing serviceable tiles to MES store and the rubbish/debrises out side MD land complete all as specified and directed.
Taking down chowkats or frame, not exceeding 1.5 Sqm in each with shutters (without taking off shutter from the frame) complete all as specified and directed.
Taking down chowkats or frames, exceeding 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm but n. exc 2 Sqm each complete all as specified and directed.
M & L for Plain cement concrete 1:2:4, type B-0, (using 12.50 mm graded stone aggregate) as in filling gap between roof sheet & wall, coping, kneelers, bed plates etc including weathering slightly rounded or chamfered angles including necessary form work complete all as specified and directed.
M & L for Plain cement concrete 1:3:6, type C-1, (using 20 mm graded stone aggregate) as in surface channels and drains including necessary form work complete all as specified and directed.
M & L for extra for forming fair finished to concrete surface of drain 30cm inner girth using grey cement including forms, mould, mitred/stopped etc complete all as specified and as directed.
Cleaning the old concrete floor surfaces by roughening surfaces & by picking, sweeping clean and washing down with water to remove dust, dirt etc and brushing neat cement slurry with 3 kg of cement per sqm on floor complete all as specified and directed.
M&L for precast cement concrete block masonry type C1, 1:3:6 (20 mm graded granite stone aggregate) with solid blocks, exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
M & L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in two layer (10mm + 5mm thick) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with water proofing compound at top 5mm thick layer by weight of cement as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
"Supply only" liquid water proofing compound complete all as specified and directed. (Make : Dr FIXIT/Fosroc/choksey)
M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant priming paint complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M & L for preparing old plastered surfaces of walls by complete removal of existing treatment and applying two coats of white wash complete all as specified and directed.
M & L for preparing old plastered surfaces of walls by complete removal of existing treatment and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
S & F well seasoned 2nd class hard wood plain, solid, straight chowkat and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints including treating the timber libarally brushed at least twice with oil or kerosene based solusion of chlorophyrifos 20EC 1.0 % (by weight) concentration complete all as specified and as directed.
S & F 30 mm thick, second class hardwood glazed and skeleton shutters as in windows/ventilators open rebated and prepared to receive glass, gauge, etc, divided in to squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded complete all as specified and directed in SSR Part I Section 8 clause 8.24 (b).
S&F 30mm thick Flush shutters, solid core construction, with block coard core & plywood face panels commercial type on both side conforming to IS 2202 (Part- I) -1999, including internal liping beading all round fixed as in Door Shutter,Cup board shutter & Kitchen rack all as specified.
S & F box type powder coated steel windows/ventilators double side shutters ie glass and wire mesh shutter, including pressed steel frames made out of CRCA sheet of 80X60X1.25mm thick double rebated, shutters box type made out of CRCA sheet of 40X20X1.0mm thick, 12mm square guard bar/grill welded to steel frame, window shutters side hung, ventilator shutters top hung, box type hinges, aluminium die cast handles for glass shutters, iron flat type handles for mesh shutters, telescopic stays etc complete all as specified in TD drawing No TD/539 dated 09.02.2004 of Chief Engineer Chennai Zone and as directed. NOTE:- (i) Qouted rate under this item shall deemed to be inclusive of steel frame, both side steel shutters, guard bars/grills, handles, stays, beading/fillets for fixing glass/wire mesh including cost elements for fixing of glass & wire mesh and mearurement/ pament shall be considered as one unit by comprising all these elements. (ii) Glass and wire mesh shall be measured and paid as supply only underseparately under respective item.
Supply only 5.5 mm thick, sheet glass, ordinary quality including oil putty/timber beads in square exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply only stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed
S & F 100 mm size, butt hinges, medium weight, cold rolled complete all as specified, and directed.
S & F 200 mm long, Aluminium, barrel tower bolts of extruded section of aluminium alloy, anodised finish not be less than Grade AC 10 of IS 1868:1996 with transparent anodic film complete all as specified and directed.
S & F 150mm size, Aluminium handles, cast type, anodised to a bright natural, mat finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and directed.
S & F aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, length of bolt of 300 mm anodised finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and directed.
S & F aluminium anodised alloy tubular towel rail, 25mm dia complete all as specified and directed.
S&F brass chromium plated curtain rod bracketsincluding stops, rollers etc complete all as specified and directed.
Cutting hole through brick masonry/stone masonry wall of half brick thich wall built in cement mortar and making good the disturbed surfaces using cement mortar 1:4 as required complete all as directed.
M & L for plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etc including necessary form work complete all as specified and directed.
S & F Rolled mild steel work as in trusses, purlins, rafter etc using Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc including cutting, welding complete. Steel section conforming to Fe-410-W (Gde-E-250) quality-B complete all as specified and directed.
S & F band, straps, supports or stays for rainwater pipes, ventilating pipes, including bolts if required hooks (stay), heavy duty, for large gate, hooks and pintle hinges, large hasp and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, wind ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and the similar small articles conforming to Fe-290 Gde- E-165 all as directed.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (Total coated thickness) of any colour, finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with best quality self tapping screws as specified
S & F Pre-Painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutter, fixed with self tapping screws complete all as specified and directed. (Colour of ridge shall be same colour as that of sheet used for roof)
M&L for machine cut kota stone slab as in flooring, self finished, 20 to 25mm thick laid and and jointed in grey neat cement slury and pointed in coloured cement to match with the shade of the stone slab including providing 20mm thick screed bed in CM 1:4 including rubbing, polishing complete all as directed.
M & L for non-skid, ceramic, coloured tiles, Grade B II(a), 8 to 10mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.36 sqm, in floors etc, including 15 mm thick screed bed in cement mortar 1:4 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for glazed ceramic, coloured tiles, Grade B III, 7 to 8 mm thick area of each tiles not less than 0.06 sqm as in skirting/dado/vertical surfaces including 10 mm thick screed bed in cement mortar 1:3 set & jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
M & L for Preparation of old or previously treated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
E/M PORTION/WORKS : Taking down copper/ aluminium point wiring(light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good distrubed surfaces of wall, floors, etc complete.
Point wiring with PVC insulated and unsheathed FRLS cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS-694 1990 drawn in and includinggrey colour PVC rigid non metalic conduit (Medium Grade) on surface conforming to IS-9537 with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3mm thick laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for :- One light/fan point controlled by one 5 Amps switch one way
All as per item No 44 above/here-in-before but for one 3 pin socket point 5 Amp on independent board
All as per item No 44 above/here-in-before but for one 3 pin socket point 5 Amp on same board with other switches.
All as per item No.44 above but with 2.5 sqmm ( Nominal area ) cable with 2.5 Sqmm size copper earth continuity conductor for 3 pin 15 A socket outlet on independent board complete all as specified and directed.
Supply and fix Switch piano, flush button single pole, 5 Amps one way.
Supply and fix Switch sokcet combination flush type 5 Amp 2/3 pin muliti purpose
Supply and fix Switch socket combination flush type 5/15 Amps 3/3 pin universal multipurpose
Supply and fix Fan regulator electronic, step & socket type 230 volt, suitable for 1200/1400mm sweep ceiling fan.
Supply and fix Ceiling rose surface bakelite 65x50mm three terminals including supply and fix PVC blocks.
S&F in replacement LED tube light fitting of 20 watts 6000K , 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Havells Cat No LUMILINEBS20WLED865SPCWH OR equivelant of make Shakti/Crompton Greaves/Bajaj
S&F new generation energy saving environmental friendly long life, with high power LED building street light/security light 1x 15 Watt LED pressure die-cast aluminium, heat resistant, toughened glass diffuser, IP65/66 protection and impact resistant of IK7 prewired with all accessories and connection up with 3 core flexible copper conductor cable 4/20 mm size, 1.5m long and testing on installation all as specified and directed. Make Havells Cat No ENDURAPEARLSL15WLED757SASYTOPCMP or equivelent of Bajaj/phillips/CG
S&F in replacement security light bracket made out of 25 mm bore GI Light grade 1.00 M long to required shape as in bracket for steet light fittings fixed with two pair of MS flate iron clamp of size 50mm X 6 mm thickness of required shape with nuts, bolts and washers suitable for steel tubular pole including painting of mild steel flate iron surface with two coates of synthetic enamel paint over a coat of red oxide primer complete including taking down unserviceable one all as specified and directed.
M & L for Sub main wiring with two runs of 4 sqmm (Nominal area) single core FRLS cable PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through grey colour PVC conduits, medium grade, of suitable size, fixed to wall/ceiling etc with all accessories, fittings, fixures including 4 sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, FRLS copper conductor as earth wire and duly connected to common earth point including PVC conduits/casing-caping of suitable size complete all as specified and as directed by Engineer-in-charge. (Note : PVC Conduits, two run wiring cables and one run of earth wire will be measured as one length.)
Supply and fix in replacement Sheet metal enclosure (ISI marked) distribution board for 240 volts, SPN 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.
Supply and fix in replacement MCB single pole 6 to 32 Amps 240 volts, C series, 10 kA rupturing capacity
Supply and fix in replacement MCB single pole & neutral 40 Amps 240 volts, C series,10 kA rupturing capacity
Taking down ceiling/exhaust fan dismantling and painting of ceiling/exhaust fan complete at site with synthetic enamel paint by spraying incl (fittings with filler) one coat after cleaning all dust etc incl connecting up. Provn of twin core cable of suitable size for ceiling rose to connector connecting of earth wire incl replacement of fan capacitor 2.5/3.15 MFD,canopy, bearing/bush, rubber bushes minor nuts bolts screws washers greassing in fan bearing & refix same complete all as directed
Rewinding of ceiling fan with appropriate size of copper enamelled wire including varnishing ,heating with proper insulation complete and testing all as specified and directed .
Cutting hole/opening through stone masonry wall of 38cm thick by using core cutting machine suitable for provision of 300mm sweep exhaust fan and making good the disturbed surfaces using cement mortar 1:4 or PCC 1:2:4, type B1 as required including toothing and bonding, finished the surfaces to match with existing ie white/colour wash as required complete all as directed.
Supply and Fixing exhaust fan, 300mm sweep metal body, AC single phase 230/240 Volt including bird free louver shutter cut to fit with hole for exhaust fan including providing holes grouting bolts and 3 core flexible copper conductor cable of size 24/0.20 sqmm connecting up from ceiling rose to exhaust fan terminal complete all as directed. Make Havells/Crompton/Orient/Bajaj
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc area not exceeding 10 Sqm on plan and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated material to a distance not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
M & L for Sand cushioning and covering with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed. (Note: Thickness after punning down shall be measured for payment)
Supply and laying well burnt bricks, locally available best quality bricks laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed.
S&F in replacement mild steel galvanized pipe light grade for protection & passing of LT cable fixed to poles/walls/laid under floor/roads complete including fittings/clamps as required at site all as specified for size of 40mm bore dia.
S&F in replacement mild steel galvanized pipe light grade for protection & passing of LT cable fixed to poles/walls/laid under floor/roads complete including fittings/clamps as required at site all as specified for size of 50mm bore dia.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, GI strips armoured cable for working voltage 1100 volts, 2 core, nominal cross sectional area of main conductor 16 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, culverts, under floors, through GI Pipe complete all as specified and as directed.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, GI strips armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 35 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, culverts, under floors, through GI Pipe complete all as specified and as directed.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, GI strips armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 70 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, culverts, under floors, through GI Pipe complete all as specified and as directed.
Fabricate, install and testing in replacement factory made bus bar chamber, outdoor type, weather proof having both side openable hinged door shutters with locking arrangement, size of chamber 80cm x 60cm x 45cm made of 3mm thick CRCA sheet, powder coated paint inside and outside, welded with 4 Nos angle iron legs of size 40 x 40 x 6mm, 80cm long duly painted with two coats of black enamelled paint over a coat of red oxide primer and errected in PCC 1:3:6, type C2 foundation/platform at suitable depth (a) MCCB, 415 Volts , 25 KA 63 Amps with thermal load release relay - 01 No (Incoming) (b) Bus bar chamber shall have 200 Amp rated copper strip Bus Bar with heat shrinkable insulating sleeve, size 30x5mm, 4 Nos of required length supported on FRP insulators, internal wiring for indicators with 10sqmm copper cable single core of required length. (b) Indicator lamps with LED bulbs for R,Y,B with copper cable wiring - 1 set.
Fabricate, install and testing in replacement factory made bus bar chamber, outdoor type, weather proof having both side openable hinged door shutters with locking arrangement, size of chamber 80cm x 60cm x 45cm made of 3mm thick CRCA sheet, powder coated paint inside and outside, welded with 4 Nos angle iron legs of size 40 x 40 x 6mm, 80cm long duly painted with two coats of black enamelled paint over a coat of red oxide primer and errected in PCC 1:3:6, type C2 foundation/platform at suitable depth. (a) MCCB, 415 Volts, 25 KA 63 Amps with thermal load release relay - 01 No (Incoming) (b) Star Delta starter suitable for 7.5 HP to 12.5 HP capacity submersible pump set (c) Bus bar chamber shall have 200 Amp rated copper strip Bus Bar with heat shrinkable insulating sleeve, size 30x5mm, 4 Nos of required length supported on FRP insulators, internal wiring for indicators with 10sqmm copper cable single core of required length. (d) Indicator lamps with LED bulbs for R,Y,B with copper cable wiring - 1 set. Make of Bus Bar Chamber: Havells or equivelent as approved by GE
Provision of trenchless bore using mechanical nuematic drilling equipment for passing electric cables through HDPE pipe of 100mm dia under the existing bituminous/WBM road/PCC hard standings, depth range not less than 1.0 mtr and upto 1.5mtr and making good to the distrubed surfaces of road to match with its existing specifications all as specified and directed by engr-in-charge at site. Note : 1. Quoted rates deems to be inclusing of necessary earth work, transportation charges of Drilling machine, and cost of HDPE pipe and passing pipe through bore complete. 2. Any damage to MES assets caused during trenchless bore shall be recitfied by the contractor at his own cost.
Material and labour in repair for earthing complete with galvanized steel earth plate 60cmx60cmx6mm thick electrode, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth strip of 35X6 mm up to test point by means of nuts, bolts, check nuts and washers of GI including excavation and earth work, PCC 1:3:6 type C-1 pit, 20mm dia GI pipe medium grade, watering pipe and 32 mm bore GI pipe, light grade for protection of earth strip, MS angle iron frame 40x40x3mm , 40 mm thick RCC 1:2:4 type B-1 cover reinforced with 6 mm dia MS bars @ 75 mm C/C both ways and with MS handle made out of 12 mm dia bars, funnel , wire mesh etc complete all as shown in electrical plate No 5 of SSR part-I and connected to earthing test point all as specified or indicated including testing on completion complete. NOTE :- Qouted rate shall deemed to be included 7.50 metre long earth trips.
M&L, Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thick buried directly in ground (earth pit depth not less than 2.25m deep below the ground level) with top edge of earth plate at a depth not less than 1.5m below ground level connected to earth using GI earth wire of 6mm dia by means of of nuts, bolts and washer and check nuts of GI or steel as shown in electrical plate No.3 of MES SSR-2009 (Part-I) and connected to earth test point all as specified or indicated including testing on completion with and including 15mm bore light grade GI protection pipe 7.5 metre long for earth including PCC (1:2:4) pit with RCC (1:2:4) type B-1 cover, 40mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hooks made out of 6mm dia MS bars, watering arrangement with 20mm dia light grade pipe, funnel, wire mesh, common salt chorcoal, necessary excavation and earth work in any type of soil complete all as specified.
R. P. Suppliers and Construction Co.
DHANUSH CONSTRUCTIONS CO.
Harish Constructions
SHANTA DURGA TRADERS
HRML CONSTRUCTIONS
VVM CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .