| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.1 LAccepted-AOC SHOP NO 18 1ST FLOOR NORTH LAND BUILDING SECTOR NO 1 BACK SIDE OF BANK OF MAHARASHTRA INDRAYANI NAGAR BHOSARI PUNE 411039 | PUNE | MAHARASHTRA | 411039 | ₹39.1 L Quoted ₹39.6 L | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER |
| 2 | L2₹40.8 L+₹1.2 L (2.99%)Rejected-Finance | ₹40.8 L+₹1.2 L (2.99%) | L2 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
| 3 | L3₹42.9 L+₹3.3 L (8.26%)Rejected-Finance 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | ₹42.9 L+₹3.3 L (8.26%) | L3 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
| 4 | L4₹44.6 L+₹5.0 L (12.5%)Rejected-Finance | ₹44.6 L+₹5.0 L (12.5%) | L4 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
| 5 | L5₹44.8 L+₹5.1 L (13.0%)Rejected-Finance | ₹44.8 L+₹5.1 L (13.0%) | L5 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
| Sl No | Description | Qty | Unit | V.R.PRAJAPATI AND CO. L2 | UNIQUE ENGINEERS L7 | JP ENTERPRISES L3 | Veekay Enterprises L4 | ShreHari Civil Enginneering and Contractors L1 | SARATH ENTERPRISES L6 | MANIYA CONSTRUCTION CO L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed by engr-in-charge. | 230 | Sqm | 15 ₹3,450 | 25 ₹5,750 | 30 ₹6,900 | 22 ₹5,060 | 5 ₹1,150 Lowest | 6 ₹1,380 | 13 ₹2,990 |
| 2.00 | M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc fixed with L-type or J- type or cranked hook bolts complete all as specified and as directed by engr-in-charge. | 200 | Sqm | 400 ₹80,000 | 425 ₹85,000 | 300 ₹60,000 Lowest | 380 ₹76,000 | 450 ₹90,000 | 405 ₹81,000 | 333 ₹66,600 |
| 3.00 | As per item No 2 above but except AC sheet complete all as specified and as directed by engr-in-charge. | 30 | Sqm | 150 ₹4,500 | 125 ₹3,750 | 150 ₹4,500 | 55 ₹1,650 Lowest | 125 ₹3,750 | 60 ₹1,800 | 166 ₹4,980 |
| 4.00 | M&L for Asbestos cement two- piece adjustable plain wing ridge 6mm thick fixed with L-type or J- type or cranked hook bolts complete all as specified and as directed by engr-in-charge. | 30 | RM | 100 ₹3,000 Lowest | 275 ₹8,250 | 150 ₹4,500 | 377 ₹11,310 | 275 ₹8,250 | 240 ₹7,200 | 270 ₹8,100 |
| 5.00 | Dismantling of Plain or corrugated/galvalume steel sheeting/mild steel sheet in valley gutter, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed by engr-in-charge. | 400 | sqm | 10 ₹4,000 | 25 ₹10,000 | 15 ₹6,000 | 55 ₹22,000 | 3 ₹1,200 Lowest | 6 ₹2,400 | 13 ₹5,200 |
| 6.00 | S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.45mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by engr-in-charge. | 270 | Sqm | 510 ₹1,37,700 | 720 ₹1,94,400 | 600 ₹1,62,000 | 500 ₹1,35,000 Lowest | 650 ₹1,75,500 | 660 ₹1,78,200 | 633 ₹1,70,910 |
| 7.00 | S& F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.45mm thick of any colour having tensile strength of 550 Mpa as in ridge, roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by engr-in-charge. | 20 | Sqm | 500 ₹10,000 Lowest | 700 ₹14,000 | 600 ₹12,000 | 666 ₹13,320 | 650 ₹13,000 | 600 ₹12,000 | 600 ₹12,000 |
| 8.00 | S&F for 0.63 mm plain Galvanised, mild steel sheeting, in ridges, hips, valley Gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275. fixed with self tapping /coach screws complete all as specified and as directed by engr-in-charge. | 10 | Sqm | 620 ₹6,200 | 750 ₹7,500 | 700 ₹7,000 | 677 ₹6,770 | 625 ₹6,250 | 600 ₹6,000 Lowest | 700 ₹7,000 |
| 9.00 | S & F for 0.63 mm Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275. fixed with self tapping /coach screws complete all as specified and as directed by engr-in-charge. | 60 | Sqm | 600 ₹36,000 Lowest | 700 ₹42,000 | 650 ₹39,000 | 689 ₹41,340 | 675 ₹40,500 | 600 ₹36,000 Lowest | 700 ₹42,000 |
| 10.00 | S&F for plain,galvanised mild steel sheeting,in ridges,hips,Valley gutters,drip and straight flashing (length and girth as fixed) by using 1.00 mm thick grade of zinc coating @120Gms/Sqm both sides and welded or soldered joints are provided complete including making shapes to valley gutter complete all as specified and as directed by engr-in-charge.
NOTE:-i)Contractor should work at height upto 10mtr w/o any extra payment.
ii)Necessary Scaffolding required for valley gutter should be arranged by contractor.
iii)Necessary arrangement of safety measure of labour working at height should be procured by the contractor
iv)Rate for scaffolding for working at height and safety measure tools for labour should be included in quoted rate & no extra payment given to contractor. | 100 | Sqm | 1,100 ₹1,10,000 | 825 ₹82,500 | 700 ₹70,000 Lowest | 900 ₹90,000 | 800 ₹80,000 | 1,260 ₹1,26,000 | 900 ₹90,000 |
Tender Value
₹74.8 L
EMD Value
₹1.4 L
Closing Date
11 Aug 2025, 6:00 pmClosed
CWE Khadki Pune
Headquarters CWE Khadki, Military Engineer Services, Range Hills Road, Khadki, Pune-411003
RAPAIR TO RCC ROOF MP TILE ROOF AC PGI CGI GALVALUME SHEETING AND SEEPAGE TREATMENT TO STONE WALL SURFACE IN DEPOT BN TB I AND BEG AND CENTRE KHADKI UNDER GE CENTRAL KHADKI
2025_MES_720281_1
CWE/KKE/TOKEN-134 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
CWE Khadki Pune
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹1,000
GE CENTRAL KHADKI
₹1.4 L
22 Dec 2025
14 Jul 2025
14 Aug 2025
14 Jul 2025
11 Aug 2025
5 Aug 2025
15 Jul 2025 - 21 Jul 2025
Amount
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed by engr-in-charge.
M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc fixed with L-type or J- type or cranked hook bolts complete all as specified and as directed by engr-in-charge.
As per item No 2 above but except AC sheet complete all as specified and as directed by engr-in-charge.
M&L for Asbestos cement two- piece adjustable plain wing ridge 6mm thick fixed with L-type or J- type or cranked hook bolts complete all as specified and as directed by engr-in-charge.
Dismantling of Plain or corrugated/galvalume steel sheeting/mild steel sheet in valley gutter, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed by engr-in-charge.
S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.45mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by engr-in-charge.
S& F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.45mm thick of any colour having tensile strength of 550 Mpa as in ridge, roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by engr-in-charge.
S&F for 0.63 mm plain Galvanised, mild steel sheeting, in ridges, hips, valley Gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275. fixed with self tapping /coach screws complete all as specified and as directed by engr-in-charge.
S & F for 0.63 mm Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275. fixed with self tapping /coach screws complete all as specified and as directed by engr-in-charge.
S&F for plain,galvanised mild steel sheeting,in ridges,hips,Valley gutters,drip and straight flashing (length and girth as fixed) by using 1.00 mm thick grade of zinc coating @120Gms/Sqm both sides and welded or soldered joints are provided complete including making shapes to valley gutter complete all as specified and as directed by engr-in-charge. NOTE:-i)Contractor should work at height upto 10mtr w/o any extra payment. ii)Necessary Scaffolding required for valley gutter should be arranged by contractor. iii)Necessary arrangement of safety measure of labour working at height should be procured by the contractor iv)Rate for scaffolding for working at height and safety measure tools for labour should be included in quoted rate & no extra payment given to contractor.
S&F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410-W(Gde E- 250) quality-A complete all as specified and as directed by engr-in-charge.
S&F steel work in tubular trushes including special shaped washer etc complete using ERW or induction but welded tubes confirming to I.S. 1161-1979 grade St. 240 etc as in purlins complete all as specified and as directed by engr-in-charge.
S & F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe-410 W(Gde E-250) quality B complete all as specified and as directed by engr-in-charge.
M & L preperation of new steel surfaces of any desciption over 10 cm in width or girth not other wise descibed and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and as directed by engr-in-charge.
Removing of old water proofing treatment and cleaning the surface of slab and clearing with wire brushes, removing dust, foreign material, rubbish off the site to a distance n.exc. 100m complete all as specified and as directed by engr-in-charge.
M&L for 10 mm thick rendering in cement mortar 1:3 on RCC roof slabs mixed with water proofing compound @ 3% mixed with by weight of cement finishing even and smooth to receive water proofing treatment complete without using extra cement all as specified and directed by Engineer-in-Charge. Note : WPC shall be measured and paid separately.
M&L for water proofing treatment over RCC slab by applying oil based bituminous primer surface @0.25 Kg/sqm and laying 3mm thik APP modified water proofing polymeric membrane with 100 mm side and end lap having weight not less than 3.50 kg/ sqm , reinforced with with non-woven polyster reinforced matt weighing not less than 160 gms/sqm polyster core having soften point not less than 1500C, longitudinal tensile strength not less than 650 N/5cm, by torching method and applying a coat of solar reflective aluminium paint @ 0.15 Kg/Sqm on membrance surface including 24 hrs ponding test complete all as specified and as directed by the Engr-in Charge.
Supply only integral water proofing compound
Dismantling of single layer Mangalore pattern or similar tiles in roof coverings complete all as specified and as directed by engr-in-charge.
S & F roof tiles, Mangalore pattern, inter locking at side joints laid dry complete all as specified and as directed by engr-in-charge.
All as per ser No 20 above except tiles complete all as specified and as directed by engr-in-charge.
S & F ridge or hip tiles to suit Mangalore pattern of roofing tiles bedded and jointed in CM 1 : 6 complete all as specified and as directed by engr-in-charge.
Dismantling battens for tiles singles etc of any size including tiling fillets spaced exc 15 cm complete all as specified and as directed by engr-in-charge.
S&F second class hard wood clean sawn battens at 30 cm centre to centre and section area exceeding 15 and not exceeding 25 sqcm complete all as specified and as directed by engr-in-charge.
As per item No 24 but except battens complete all as specified and as directed by engr-in-charge.
Dismantling of wall and ceiling boards (fibre,pulp insulation, Ac etc), any thickness including cover fillets complete all as specified and as directed by engr-in-charge.
M&L for GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20mm and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm cetre to centre /intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expension fasteners with and including ceiling section (not exc 1.2m length ) of 0.55 mm thickness having kurled web of 50 mm and flenge of 26 mm each with lips of 10.5 mm foxed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and as directed by engr-in-charge.
M&L for 8-9 mm thick Gypsum board/tiles for insulation and accoustic purposes, 60cmx60cm in size , fixed with nails to timber frame work or with staples on snap grid in ceiling complete all as specified and as directed by engr-in-charge.
M&L for 6-9mm thick Plywood, grade BWP,type BB fixed with screws to timber frame work and fixed in ceiling,flat or sloping complete all as specified and as directed by engr-in-charge.
Dismantling timber framed work scantlings 40 sq.cm and over in section, in any position complete all as specified and as directed by engr-in-charge.
ditto as per ser No 30 above but in fillets, rails, posts, rafters,purlins etc under 40 sq. cm in section complete all as specified and as directed by engr-in-charge.
S&F for 2nd class hard wood timber framed and fixed clean sawn in scantling complete all as specified and as directed by engr-in-charge.
M&L for two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces including all necessary preparation over 10 cms width or girth complete all as specified and as directed by engr-in-charge.
Demolition of reinforcement cement concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed by engr-in-charge.
S&F for Providing precast cement concrete louvres and jallies, 35 mm thick (measured solid), including all mouldings using cement concrete type B0 1:2:4 (12.50 mm graded aggregate) set in cement mortar 1:4 complete all as specified and as directed by engr-in-charge.
Preparing new plastered surfaces on walls /jallies applying three coat of white wash(lime wash) complete all as specified and as directed by engr-in-charge.
Demolition of cement concrete unreinforced in ground floors and pavings n.exc. 15cm thickness below or above ground level complete all as specified and as directed by engr-in-charge.
Demolition of stone slabs/flooring of any description laid bedded and pointed any mortar complete all as specified and as directed by engr-in-charge.
M&L for Kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and as directed by engr-in-charge.
Ditto as per ser No 39 but on step riser skirting over and including 10mm thick rendering in CM (1:4) complete all as specified and as directed by engr-in-charge.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as specified and as directed by engr-in-charge.
Welding in repairs n. exc 5cm in length Thickness of metal to be welded n exc 6mm complete all as specified and as directed by engr-in-charge.
S&F in repair mild steel, Fe 410-W (Gde E- 250 quality-A) Framed work as in doors or gates,roof structure of any size and section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; including all necessary fitting, also fastening and fixing,including dismantling, complete all as specified by Engr-in-Charge
S&F Fibre glass reinforced translucent sheeting as in hideout with side lap fixed with coach screw and washer in roof, wall etc complete all as specified and as directed by engr-in-charge.
S&F in repair Collapsible steel gates, top hung, consisting of channel pickets, pivotedflat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets,including dismantling, complete all as specified and as directed by engr-in-charge.
M&L Cement concrete (1:3:6) type C-2 using 20 mm graded stone aggregate as in floor, plinth protection, 75 mm thick, surfaces finished even and fair without using extra cement as in plinth protection including provision of construction joints complete all as specified and as directed by engr-in-charge.
Demolition of precast concrete block /brick work walling built in cement mortar complete all as specified and as directed by engr-in-charge.
Taking down cement plaster on wall /concrete surface etc including racking out joints hacking for key scrubing down with water etc complete all as specified and as directed by engr-in-charge.
M&L for Precast cement concrete block masonry using type C1 1:3:6 (20 mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in mortar1:6 complete all as specified and as directed by engr-in-charge.
M&L for rendering 15 mm thick on faces of brick/ PCC block masonry wall using cement plaster 1:4 and rendering is to be finished even and smooth (without using extra cement) complete all as specified and as directed by engr-in-charge.
M & L preparation of newly plastered surface and applying two coat of cement base paint on wall etc complete all as specified and directed
M & L for rendering 15mm thick on fair faces brick work /PCC block masonary or concrete surface of wall using cement plaster 1:6 and finished even and smooth (without using extra cement) complete
M & L preparation of newly plastered surface and applying two coat of oil bound Distember over a coat of primer on wall etccomplete all as specified and as directed by engr-in-charge.
Repairing the leaking deteriorated and torn out chajjas and parapet walls by removing all the lose material from the top of the chajja by means of light hammering and chiselling to remove loose concrete cover only and Clean all loose particles by high pressure jet water so that all surfaces should be sound, clean and free of contamination followed by application two coats of polymerised cementitious coat like Pidilite's Pidifin 2k or equivalent, while second coat is wet apply a 10mm dash coat of CM plaster with the waterproofing compound Make : Dr.fixit or equivalent as approved by GE, completing the repair work by final finishing and providing with proper slope of 15 mm thick rendering cement mortar(1:4) including supply and mixing of waterproofing compound as per manufacturers instructions finishing the surfaces even and fair complete all as specified and as directed by engr-in-charge.
Cleaning the surface with wire brush, detecting sources of leakages and removing/taking down unsound treatment/surface and M&L for making holes with drill machine of dia 14mm for carrying out non-destructive waterproofing treatment to sunken portion of slab, floor and walls of bath, WC, WHB and floor traps (combined unit) by using construction chemical method as hydrophobic PU grouting, etc, with first course of injection MDI based PU foam and second course of injection PU plain all as per manufacturers instruction, etc, complete and as directed. The PU foam shall have 100% solids and solvent free, and shall expand 30-40 times its volume at liquid stage in presence of water, the PU plain injection shall have minimum 100 CPS viscosity and shore hardness minimum 50. (Make: PIDILITE or techno commercially equivalent) complete all as specified and directed. and M&L for fixing the metallic packer for hydrophobic PU foam and Sealer complete all as specified and as directed by engr-in-charge.
M&L for the tile joint chemical cleaning and re-grouting carefully by washing the existing tile with heavy duty tile cleaner preferably of M/S Pidilite or equivalent cleaner, again washing with fresh jet water, scratching the joints and filling the same with (white/matching colour) epoxy tile grout of M/s Pidilite, ROFF RTM epoxy or equivalent, curing, cleaning the surface etc, complete all as directed by Engr-in-Charge and as per the sample done at ground level complete all as specified and as directed by engr-in-charge.
S&F 3 layered rotational moulded polyethylene water storage tanks capacity 1000 lit in white colour ( cylindrical vertical with closed top ) hoisted and fixed in position including dismantling and removing of old tank complete all as specified and as directed by engr-in-charge.
S&F 3 layered rotational moulded polyethylene water storage tanks capacity 500 lit in white colour ( cylindrical vertical with closed top ) hoisted and fixed in position including dismantling and removing of old tank complete all as specified and as directed by engr-in-charge.
Dismantling floor hearth or wall tilling including cement mortar bedding (but not backing ) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by engr-in-charge.
M&L for 25 mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in sub base for levelling,etc complete all as specified and as directed by engr-in-charge.
M&L coloured non skid ceramic tiles 300 mm x 300 mm x 6 to 7mm thick,in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed by engr-in-charge.
M&L glazed coloured ceramic tiles size of tiles 300x600/450x350x6 to 7mm thick vertical surface such as in skirting/dado etc over and including 10 mm thick cement plaster in CM 1:4 complete all as specified and as directed by engr-in-charge.
M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick screed bed in cement mortar (1:4) complete all as specified and as directed by engr-in-charge.
M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick rendering in cement mortar (1:3) complete all as specified and as directed by engr-in-charge.
M&L for vitrified tiles 10 mm thick light shade, (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM (1:6) complete all as specified and as directed by engr-in-charge.
All as per item no.65 above but as in skirting over,including 10mm thick plaster in CM(1:4) complete all as specified and as directed by engr-in-charge.
M&L for external stone walls/steps of any height are as follows:- (a)Cleaning of external stone surface of walls/steps at any height with pressure pump with clean water (a) Applying one coat of cleaning solution of Dr Fixit/pidilite or other reputed brand and throughly cleaning the surface, (b)The loose masonary joints to be properly pointed with (1:3) cement sand mortar mixed with WPC complete all as specified and directed. (c)Necessary scafolding shall deemed to be included in the quoted rate.scafolding shall be having ease of access for inspection purpose (d)Second washing of the surface of wall/steps any height (whereever required at site as directed by Engineer-in-charge) with super heated steam to remove grease,moss algaee & bird dropping etc with heavy jet pressure pumps (Torik stone cleaning similiar pumps,Tensid UK LTD or Doff superheated steam cleaning or similiar pumps as approved) complete all as specified and directed. (d) The filling of joints between stones with cement-Asian equivalent paint grout and application of two coats of hydrophobic stone sealer as per manufacturers instructions complete all as specified and as directed by Engr-in-charge.
NOTE:- 1-Quoated rate includes providing necessary scafolding of G+2 stories bldg with safety measure of labour at any height as per site requirement. upto 9 Mtr height. 2-Before quoting the tender contractor should visit the site. 3-Treatment should be carried out with skilled labour and by authorized applicators.
V.R.PRAJAPATI AND CO. (BID ID -3388614)
JP ENTERPRISES (BID ID -3389201)
Veekay Enterprises (BID ID -3390037)
MANIYA CONSTRUCTION CO (BID ID -3390181)
SARATH ENTERPRISES (BID ID -3387694)
UNIQUE ENGINEERS (BID ID -3389059)
Bidder Name
JP ENTERPRISES
V.R.PRAJAPATI AND CO.
UNIQUE ENGINEERS
Veekay Enterprises
SARATH ENTERPRISES
ShreHari Civil Enginneering and Contractors
MANIYA CONSTRUCTION CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .