Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 LAccepted-Finance | L1 | Accepted-Finance Lowest amount | |
| 2 | L2₹7.4 L+₹71,765 (10.7%)Rejected-Finance | L2 | Rejected-Finance High amount | |
| 3 | L3₹8.4 L+₹1.6 L (24.5%)Rejected-Finance | L3 | Rejected-Finance High amount |
Tender Value
₹8.6 L
Closing Date
25 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Kommaraju Srinivasarao
No 7, Old Depot Line, Pune - 40
Supply and Installation of ABT meters to avail open access power evacuation for Command Hospital under GE (I) (P) CH Pune.
2022_MES_557181_1
3001/Q07/E3
Open Tender
Job Works
Works
60 days
GE (I) (P) CH Pune
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
Exempted
2 Nov 2022
12 Oct 2022
26 Oct 2022
13 Oct 2022
25 Oct 2022
13 Oct 2022
Supply, install,testing and commissioning of suitable ABT Meter (22 kV) (model CTR--/5 A,PTR11 KV/110V) conforming to IEC 62053 accuracy class 0.2s - 2 Nos (01xMain meter & 01x check Meter) SEM metering capable of measuring four quadrant Imp-Exp energy measurement facility & DIP 15 Min, Suitable for KVAh building and KVAh, KVA MD & PF calculation based on RKVAh (Lag+Lead) basis, 3x63.5V, 50 Hz 3 Phase 4 wire (Neutral solidly grounds) and AMR compatible and integration to control center of MSEDCL including sutable Modem for AMR all as specified and directed by Engr-in-charge. (Make: Secure or equivalent )
Supply, install,testing and commissioning of suitable ABT Meter (22 kV) (model CTR--/1 A,PTR11 KV/110V) conforming to IEC 62053 accuracy class 0.2s 1 nos (Enery audit meter) SEM metering capable of measuring four quadrant Imp-Exp energy measurement facility & DIP 15 Min, Suitable for KVAh building and KVAh, KVA MD & PF calculation based on RKVAh (Lag+Lead) basis, 3x63.5V, 50 Hz 3 Phase 4 wire (Neutral solidly grounds) and AMR compatible and integration to control center of MSEDCL all as specified and directed by Engr-in-charge. (Make:Secure or equivalent)
Supply, install,testing and commissioning of C.T suitable for above ABT meter (22kV) speciecification as below: (Make:Huphen Electromech Pvt Ltd as per existing (a) C.T ratio of Main meter 100/5A, Accuracy Class 0.2s, VA Burden 10 VA - 03 Nos (b) C.T ratio of Check meter 100/5A, Accuracy Class 0.2s, VA Burden 10 VA - 03 Nos
Removing of existing C.T any type - 06 Nos.
Note: (a) Meter and CT should be approved and tested from MSEDCL and contractor shall obtain neccessary approval and certificate from MSEDCL. (b) Contractor authorization & valid license copy of the contractor from MSEDCL (c) The bidder should have executed within preceding 3 years similar works amounting to not less than 05 lakhs. (The bidder should submit experience certificate regarding completion of similar type of works (e.g erection/maint of HT 11 KV, 22 KV, 33 KV, CT/PT, metering cubical)
Krutika Electricals
Takshashila electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .