Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAdmitted-Finance | ₹1.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.9 Cr+₹2.0 L (1.01%)Admitted-Finance | ₹1.9 Cr+₹2.0 L (1.01%) | L2 | Admitted-Finance |
| 3 | L3₹2.0 Cr+₹5.2 L (2.69%)Admitted-Finance | ₹2.0 Cr+₹5.2 L (2.69%) | L3 | Admitted-Finance |
| 4 | L4₹2.7 Cr+₹76.1 L (39.4%)Admitted-Finance | ₹2.7 Cr+₹76.1 L (39.4%) | L4 | Admitted-Finance |
| 5 | L5₹2.9 Cr+₹1.0 Cr (52.6%)Admitted-Finance | ₹2.9 Cr+₹1.0 Cr (52.6%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Shantha Electricals and Engineers Pvt Ltd L4 | SHRI VAARI ELECTRICALS PVT LTD L1 | Micron Engineering Services Inc L3 | Sequent Electricals L2 | Arken Solutions Pvt. Ltd L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00Supply and Installation of Heat Tracer Panels: Supply ,Installation, Testing & Commissioning of 415 V, 50Hz, 15 Zone Heat Tracer Panels.Panels shall contain 15 Zones; each of 3kW,230V AC Rated heater circuits, with Temperature indication controller,input MCB, ELCB, Power contactor,SSR and ON /OFF indicating Lamps and circuit acessories as per Technical specifications and drawings attached. | ||||||||
| 1.01 | Supply Part | 7 | Nos | 11,20,000 ₹78,40,000 | 5,03,477 ₹35,24,339 | 4,48,400 ₹31,38,800 | 2,18,382 ₹15,28,674 Lowest | 11,39,980 ₹79,79,860 |
| 1.02 | Installation,testing and commissioning part. | 7 | Nos | 12,000 ₹84,000 | 10,000 ₹70,000 | 5,000 ₹35,000 Lowest | 11,682 ₹81,774 | 17,700 ₹1,23,900 |
| 2.00Supply and Installation of Heater Control Panels : Supply, Installation , Testing & Commissioning of Heater Control Panels. Heater control panels shall contain 6 Zones each of 3 phase, 415V, 6 kW rated with SCR controller module based with temperature indication controller as per Technical specs and drawings attached. | ||||||||
| 2.01 | Supply Part | 3 | Nos | 6,78,000 ₹20,34,000 | 4,79,591 ₹14,38,773 Lowest | 12,65,786 ₹37,97,358 | 5,11,908 ₹15,35,724 | 5,25,820 ₹15,77,460 |
| 2.02 | Installation,testing and commissioning part. | 3 | Nos | 12,000 ₹36,000 | 10,000 ₹30,000 | 5,000 ₹15,000 Lowest | 32,450 ₹97,350 | 11,800 ₹35,400 |
| 3.00Supply and Installation of MCC Panel P1: Design, manufacture,shop testing at works, supply ,installation, testing & commissionig of floor mounted, front operated, front accessed MCC panel totally enclosed with IP-54 protection .MCC panel feeders should be as per the technical specs and drawings attached. | ||||||||
| 3.01 | Supply part | 1 | Nos | 4,95,000 ₹4,95,000 | 3,81,132 ₹3,81,132 | 4,89,700 ₹4,89,700 | 3,28,748 ₹3,28,748 Lowest | 4,65,560 ₹4,65,560 |
| 3.02 | Installation,testing and commissioning part. | 1 | Nos | 12,000 ₹12,000 | 10,000 ₹10,000 | 5,000 ₹5,000 Lowest | 15,576 ₹15,576 | 11,800 ₹11,800 |
| 4.00Supply and Installation of MCC Panel P2: Design, manufacture,shop testing at works, supply ,installation, testing & commissionig of floor mounted, front operated, front accessed MCC panel totally enclosed with IP-54 protection .MCC panel feeders should be as per the technical specs and drawing attached. | ||||||||
Tender Value
₹2 Cr
EMD Value
₹4 L
Closing Date
15 Jul 2022, 3:30 pmClosed
CHIEF ENGINEER
BARC MYSURU
Internal Electric Power Distribution Works at BARC Mysore.
2022_BARC_690917_1
BARC /MYS /DCI /ELEC /WT-01 /2021-22
Open Tender
Electrical Works
Item Rate
365 days
BARC MYSURU
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹4 L
Yes
12 Oct 2022
25 May 2022
26 Jul 2022
27 May 2022
15 Jul 2022
27 Jun 2022
14 Jun 2022 - 19 Jun 2022
Amount
Supply and Installation of Heat Tracer Panels: Supply ,Installation, Testing & Commissioning of 415 V, 50Hz, 15 Zone Heat Tracer Panels.Panels shall contain 15 Zones; each of 3kW,230V AC Rated heater circuits, with Temperature indication controller,input MCB, ELCB, Power contactor,SSR and ON /OFF indicating Lamps and circuit acessories as per Technical specifications and drawings attached.
Supply Part
Installation,testing and commissioning part.
Supply and Installation of Heater Control Panels : Supply, Installation , Testing & Commissioning of Heater Control Panels. Heater control panels shall contain 6 Zones each of 3 phase, 415V, 6 kW rated with SCR controller module based with temperature indication controller as per Technical specs and drawings attached.
Supply Part
Installation,testing and commissioning part.
Supply and Installation of MCC Panel P1: Design, manufacture,shop testing at works, supply ,installation, testing & commissionig of floor mounted, front operated, front accessed MCC panel totally enclosed with IP-54 protection .MCC panel feeders should be as per the technical specs and drawings attached.
Supply part
Installation,testing and commissioning part.
Supply and Installation of MCC Panel P2: Design, manufacture,shop testing at works, supply ,installation, testing & commissionig of floor mounted, front operated, front accessed MCC panel totally enclosed with IP-54 protection .MCC panel feeders should be as per the technical specs and drawing attached.
Supply part
Installation,testing and commissioning part.
Supply and Installation of MCC Panel P3: Design, manufacture,shop testing at works, supply ,installation, testing & commissionig of floor mounted, front operated, front accessed MCC panel totally enclosed with IP-54 protection .MCC panel feeders should be as per the technical specs and drawing attached.
Supply part
Installation,testing and commissioning part.
Supply and Installation of MCC Panel P4: Design, manufacture,shop testing at works, supply ,installation, testing & commissionig of floor mounted, front operated, front accessed MCC panel totally enclosed with IP-54 protection .MCC panel feeders should be as per the technical specs and drawing attached.
Supply part
Installation,testing and commissioning part.
Supply and Installation of AC Switching panels :Design, manufacture,shop testing at works, supply ,installation, testing and commissiong of AC switching panels of floor mounted, front operated, front accessed, totally enclosed with IP-54 protection .AC switching panels should be as per the specs and drawing attached.
Supply Part
Installation,testing and commissioning part.
Supply and Installation of DC Switching Panel : Design, manufacture,shop testing at works, supply ,installation, testing and commissiong of DC switching panel (containing DC change over swicth) of floor mounted, front operated, front accessed, totally enclosed with IP-54 protection .DC switching panel should be as per the specs and drawing attached.
Supply Part
Installation,testing and commissioning part.
Installation of 100V/300A ,30kW DC power supply panel : Only Installation of 100V/300A, 30kW DC power supply panel of size 2x1x1.5 Mts of aprox. Weight of 100kgs at II floor.Panel will be supplied by department as free issue material.
Supply and Laying of LT Power cables : Supply & laying of 1.1 KV grade aluminium/Copper stranded circular/ sector shape core conductor with XLPE insulation, extruded PVC (ST-2) inner sheathed, G.I flat strip/wire armoured, extruded FRLS grade antirodent & anti termite PVC (ST-2) outer sheathed cable conforming to IS : 1554 Part I / IS 7098 Part-I with latest amendments, Recommended Make: Finolex/Universal/Polycab/ RRKable
3.5Cx185Sq.mm Al.Conductor cable
Supply Part
Laying part.
2Cx70Sq.mm Al.Conductor cable
Supply Part
Laying part.
3.5Cx70Sq.mm Al.Conductor cable
Supply Part
Laying part.
4Cx35Sq.mm Al.Conductor cable
Supply Part
Laying part.
3Cx 4Sq.mm Cu. Conductor cable
Supply Part
Laying part.
2Cx2.5Sq.mm Cu. Conductor cable
Supply Part
Laying part.
LT Cable Termination: End jointing of following sizes of cable (For all phases including neutral) by crimping with supply of all jointing materials like tinned Cu/Al lugs,double compression brass cable glands,gland earthing, insulation tape, duplicate interconnection between gland earthing strip & to the nearest earthing bus terminals as per the specifications and as per the instructions of the Engineer-in-charge. Aluminium Glands for Aluminium conductor & Copper glands for copper conductors. Recommended make: Commet/Dowels/HMI/3D
3.5Cx185Sq.mm Al.Conductor cable
Supply Part
Installation,testing and commissioning part.
2Cx70Sq.mm Al.Conductor cable
Supply Part
Installation,testing and commissioning part.
3.5Cx70Sq.mm Al.Conductor cable
Supply Part
Installation,testing and commissioning part.
4Cx35Sq.mm Al.Conductor cable
Supply Part
Installation,testing and commissioning part.
3Cx 4Sq.mm Cu. Conductor cable
Supply Part
Installation,testing and commissioning part.
2Cx2.5Sq.mm Cu. Conductor cable
Supply Part
Installation,testing and commissioning part.
Cable trays and cable management system: Supplying and erection of following sizes of perforated GI cable trays, hot dipped galvanised between 60 and 80 microns of zinc ,including horizontal and vertical bends, reducers, tees, cross members and other accessories as required, wall mounting brackets etc.
300mm width x 100 mm depth
Supply Part
Installation,testing and commissioning part.
100mm width x 50 mm depth
Supply Part
Installation,testing and commissioning part.
Supply and Fabrication of MS structures:
Supply of supports using MS channel/angle / flat/ MS rod hangers (65x65x6 & 30x30x5 etc..) etc.including painting with two coats of primer and two coats of epoxy paint of approved shade as per instructions of EIC. Recommended Make : SAIL/TATA
Fabrication and installation of supports using MS channel/angle / flat/ MS rod hangers (65x65x6 & 30x30x5 etc..) etc.including painting with two coats of primer and two coats of epoxy paint of approved shade as per instructions of EIC. Recommended Make : SAIL/TATA
Supply and Installation of Copper bus bars: Supply ,installation and laying of Copper bus bars of following sizes and length, as per the specifications attached and as per engineer-in-charge instructions.
200mm x10 mm
Supply Part(Approximate length=170mts)
Installation,testing and commissioning part.(Approximate length=170mts)
80mm x12mm
Supply Part(Approximate length=50mts)
Installation,testing and commissioning part.(Approximate length=50mts)
50mm x10mm
Supply Part(Approximate length=50mts)
Installation,testing and commissioning part.(Approximate length=50mts)
60mm x12 mm
Supply Part(Approximate length=50mts)
Installation,testing and commissioning part.(Approximate length=50mts)
Supply and installation of FRP/Hylum bus bar supports:
Supply of FRP/Hylum bus bar supports of minimum 20mm thickness , as per the specifications attached.
Fabrication and erection of FRP/Hylum bus bar supports of minimum 20mm thickness to suitable size cut outs for holding copper bus bars,finishing edges and securing supports to MS angle Frame work with fasteners.
Supply of Copper Flexible bus bars: Supply of Copper flexible bus bars of continuous current rating 1600A DC of 1meter each as per the specifications and drawing attached.
Supply and Installation of copper earthing conductors: Supply ,installation and laying of earthing copper conductors of following sizes as per specs instructed by the Engineer-in-charge.
25mmx3mm copper strip
Supply Part
Installation,testing and commissioning part.
8 SWG copper wire
Supply Part
Installation,testing and commissioning part.
14 SWG copper wire
Supply Part
Installation,testing and commissioning part.
Earth Excavation: Under ground cable laying consisting of Excavation,laying of bricks ,M-sand and refilling (manual) of all types of soil including hard murrahm upto a depth of 1.5meters at plant site.
Sequent Electricals
Micron Engineering Services Inc
Shantha Electricals and Engineers Pvt Ltd
Arken Solutions Pvt. Ltd
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Part1Vol1Sec2.pdf
Tender Documents • 0.63 MB
Part1Vol1Sec3.pdf
Tender Documents • 0.43 MB
Part1Vol3.pdf
Tender Documents • 1.54 MB
Part1Vol1Sec4.pdf
Tender Documents • 0.95 MB
Part1Vol1Sec5.pdf
Tender Documents • 0.48 MB
Part1Vol2.pdf
Tender Documents • 1.57 MB
BOQ_727049.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .