Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 CrAdmitted-Finance | ₹23.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹24.1 CrAdmitted-Finance | ₹24.1 Cr | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MS Anil Kumar Kapahi Contractor L1 | A B ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00 | CIVIL WORKS
EARTH WORKS
Earth work in excavation by mechanical means (Hydraulic excavator) over areas (Exceeding 30cm in depth, 1.5mtr in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.50 m, disposed earth to be levelled and neatly dressed:
Earth work in excavation by mechanical means (hydraulic excavator)
0.0-1.50m | 3,355.21 | Cum | 199 ₹6.7 L | 200 ₹6.7 L |
| 2.00 | Earth work in excavation by mechanical means (hydraulic excavator)
1.50-.3.00m | 3,355.21 | Cum | 99 ₹3.3 L | 200 ₹6.7 L |
| 3.00 | Earth work in excavation by mechanical means (hydraulic excavator)
3.00-.4.50m | 3,355.21 | Cum | 199 ₹6.7 L | 150 ₹5.0 L |
| 4.00 | Earth work in excavation by mechanical means (hydraulic excavator)
4.50-.6.00m | 1,677.2 | Cum | 199 ₹3.3 L | 150 ₹2.5 L |
| 5.00 | Earth work in excavation by mechanical means (hydraulic excavator)
6.00-.7.50m | 78.6 | Cum | 199 ₹15,641.10 | 150 ₹11,789.77 |
| 6.00 | Earth work in excavation by mechanical means
(Hydraulic excavator) in foundation trenches, drains,
pipes and cables etc. (not exceeding 1.5mtr in width or 1 Osqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5mtr including getting out excavated soil and disposal of surplus soil as directed, within a lead of 50 mtr.
All kinds of soil | 438.75 | Cum | 199 ₹87,311.25 | 150 ₹65,812.50 |
| 7.00 | Extra rates for quantities of works, executed :
In or under water and/or liquid mud, including pumping out water as required.
4.50-.6.00m | 1,677.2 | metre depth | 299 ₹5.0 L | 60 ₹1.0 L |
| 8.00 | 6.00-.7.50m | 78.6 | metre depth | 299 ₹23,500.95 | 80 ₹6,287.88 |
| 9.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc, in layers of not exceeding 20 cm in depth, consolidating each deposited layer by rammiing and watering lead upto 50 m and lift upto 1.5 m. | 912.25 | Cum | 199 ₹1.8 L | 90 ₹82,102.11 |
| 10.00 | Carriage of Earth by mechanical transport including loading, unloading and Stacking including royalty & carriage up to 5 KM complete. | 10,909.2 | Cum | 199 ₹21.7 L | 200 ₹21.8 L |
Tender Value
₹24.0 Cr
EMD Value
₹47.9 L
Closing Date
23 Nov 2020, 4:00 pmClosed
SURESH REKHI
Office of the Deputy General Manager, JKPCC Ltd., Unit Leh.
Construction of Multi Level Car Parking at Leh.
2020_PWDJK_108177_1
No 113/e-tendering/DGM/Leh of 2020-21 Dt. 02-11-20
Open Tender
Civil Works
365 days
LEH
Please refer Tender documents.
7 documents required · 7 mandatory
₹5,000
Yes
Financial Controller, JKPCC Ltd.
₹47.9 L
Yes
EXECUTIVE DIRECTOR, JKPCC LTD.
14 Dec 2020
2 Nov 2020
24 Nov 2020
2 Nov 2020
23 Nov 2020
10 Nov 2020
10 Nov 2020
Amount
CIVIL WORKS EARTH WORKS Earth work in excavation by mechanical means (Hydraulic excavator) over areas (Exceeding 30cm in depth, 1.5mtr in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.50 m, disposed earth to be levelled and neatly dressed: Earth work in excavation by mechanical means (hydraulic excavator) 0.0-1.50m
Earth work in excavation by mechanical means (hydraulic excavator) 1.50-.3.00m
Earth work in excavation by mechanical means (hydraulic excavator) 3.00-.4.50m
Earth work in excavation by mechanical means (hydraulic excavator) 4.50-.6.00m
Earth work in excavation by mechanical means (hydraulic excavator) 6.00-.7.50m
Earth work in excavation by mechanical means (Hydraulic excavator) in foundation trenches, drains, pipes and cables etc. (not exceeding 1.5mtr in width or 1 Osqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5mtr including getting out excavated soil and disposal of surplus soil as directed, within a lead of 50 mtr. All kinds of soil
Extra rates for quantities of works, executed : In or under water and/or liquid mud, including pumping out water as required. 4.50-.6.00m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc, in layers of not exceeding 20 cm in depth, consolidating each deposited layer by rammiing and watering lead upto 50 m and lift upto 1.5 m.
Carriage of Earth by mechanical transport including loading, unloading and Stacking including royalty & carriage up to 5 KM complete.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. All kinds of soil
Supplying chemical emulsion in sealed containers including delivery as specified Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Anti termite treatment Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.
CONCRETE WORKS Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) (A) Crushed
Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns
Extra for laying concrete in or under water and/or liquid mud including cum per cost of pumping or bailing out water and removing slush etc. complete.
REINFORCED CEMENT CONCRETE WORK Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete.
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform.
Shelves (Cast in situ)
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts.
Stairs, (excluding landings) except spiral-staircases.
Edges of slabs and breaks in floors and walls Under 20 cm wide
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars.
Extra for laying reinforced cement concrete in or under water and/ or liquid mud, including cost of pumping or bailing out water and removing slush etc., complete.
Providing and laying in position machine· batched, machine mixed and machine vibrated -design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering, finishing and reinforcement, including Admixtures in recommended proportions, (as per IS 91 03) to accelerate, retard setting of concrete improve workability without impairing strength and durability as per direction of Engineer-in-charge-M-20 grade reinforced cement concrete. All works upto plinth level.
All works above plinth level upto floor V level. Walls, columns, pillars, posts and struts.
Beams, plinth beams, girders, bressumers, centilevers, suspended floor lintels roofs and staircases including spiral staircases, shelves etc.
Add or deduct for providing richer or leaner mixes respectively at all floor levels. Providing M-30 grade R.C.C. instead of M-20 grade R.C.C.(cement content considered in M30 is@ 340 kg/cum)
Deduct for using less cement than the quantity as provided in the item of batch mix concrete/RMC as arrived as per mix design
BRICK WORK Providing and fixing upto floor five level precast cement concrete solid blocks including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centring, shuttering and complete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size)(A) Crushed
Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry (with F.P.S. bricks).
MARBLE & GRANITE WORK Providing and fixing gang saw cut mirror polished (pre moulded and pre polished), machine cut for kitchen platform, vanity counters window sills facias and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. Granite of any colour and shape (Area of slab over 0.5 sqm) 18mm thick
Extra for fixing marble / granite stone over and above corresponding basic item, in facia and drops of width upto 150mm with epoxy resin baesd adhesive including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/Stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edge etc. complete.
Providing and fixing stone slab table rubbed and polished of size 75 em x 50 em deep and 1.80 em thick fixed in urinal partitions with cement concrete 1:2:4 (1 ·cement : 2 coarse sand : 4 stone aggregate 6 mm nominal size) and finished smooth. Granite Stone of approved shade
WOOD & PVC WORK Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Second class teak wood
Providing and fixing lSI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial ply veneering with .~ vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including lSI marked M.S. pressed bright finished butt hinges with necessary screws of required size.
Extra for providing lSI marked Stainess Steel butt hinges instead of M.S.pressed butt hinges bright finished of required size with necessary screws, (Shutter area to be measured).
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured)
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 2nd class teak wood 50x12 mm
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 300x10 mm
Providing and fixing aluminium handles of approved make anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessry screws etc. complete. 125 mm
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Single rubber stopper
FD120 Fire rated doors with 30 minutes insulation - Staircase Providing and fixing of Hollow metal Insulated fire rated doors as per IS 3614 part-1, for stability, integrity & insulation. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2 / ISO 834-1 Part 1 / BS476 Part 20 & 22, CBRI / Cerifire or third party certified or equivavelent lab, for maximum rating of 120mins with 30minutes of insulation, in latched /unlatched condition (if used with deadbolts and pull handles). Labled doors with certification shall be with vision glass as a part of complete assembly. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied shall be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Approved manufacturer Shakti Hormann or approved equivalent. Door frame shall be single rebate grooved profile of size 125 x 55mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff.
Door leaf shall be 46mm thick fully flush double skin door, insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be high density insulation material. Intumescent seals 15x2mm to be provided all around the door in addition to the grooved smoke seal. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 6mm clear borosilicate fire rated glass of relavant rating of the door. All doors and frames shall be finished to “PURE POLYSTER POWDER COATING” for minimum 50 microns (on the visible surface of the Shutter and Frame) of approved colour. The door leaf and frame shall have passed minimum 500 hours of salt spray test Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. All hardware cost should be paid seperatelly. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer in charge.
FD-120Mins size 1200x2100mm Fire Rated Singe leaf door with 200x300 vision panel of 6mm thick glass with inclusive of below Hardware Set- 4no ball bearing butt hinges,1no panic bar with external trim,door closer,smoke seal for frame,intumecent seal for shutter-all hardware make Hormann
FD120 Fire rated un insulated doors - Electrical Shaft Providing and fixing of Hollow metal Un-Insulated fire rated doors as per IS 3614 part-1, for stability and integrity. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2 / ISO 834-1 Part 1 / BS476 Part 20 & 22, CBRI / Cerifire or third party certified or equivavelent lab, for maximum rating of 120mins, in latched /unlatched condition (if used with deadbolts and pull handles). Labled doors with certification shall be with vision glass as a part of complete assembly. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied shall be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Approved manufacturer Shakti Hormann or approved equivalent. Door frame shall be single rebate grooved profile of size 125 x 55mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening.
Door leaf shall be 46mm thick fully flush double skin door, Un-insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 6mm clear borosilicate fire rated glass of relavant rating of the door. All doors and frames shall be finished to “PURE POLYSTER POWDER COATING” for minimum 50 microns (on the visible surface of the Shutter and Frame) of approved colour. The door leaf and frame shall have passed minimum 500 hours of salt spray test
Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer. FD1-120Mins size 1500x2100mm Fire Rated Double leaf door with 200x300 vision panel of 6mm thick glass with below Hardware Set- 8no ball bearing butt hinges,mortise dead lock with both side key cylinder,2 pair D type pull handle of 300mm long, smoke seal for frame,2no conceald flush bolt and 1no door closer-all hardware make Hormann
STEEL WORK Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 16.80 sqm in area
Extra for providing rolling shutters manufactured out of 8mm dia.M.S. bar instead of laths as per design approved by Engineer-in-Charge. (area of grill to be measured.)
Providing and fixing hexagonal M.S. sheet ceiling fan box with clamp of internal dia 140mm, 73mm height, 3mm thick rim, top and bottom lid of 1.5mm M.S. sheet. Lid shall be screwed into M.S. box by means of 3mm round headed screws, clamps shall be made of 12mm dia. M.S. bar bent tc shape as per standard drawing with over all length as 80cm.
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
STRUCTURAL STEEL WORK Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Note: Contractor to prepare & submit M.S. Work fabrication drawings for the approval from Consultant before commencement of work at site. Hot finished welded type tubes
Providing and fixing M.S. round holding down bolts, nuts and washer plates complete.
FLOORING WORK Cement concrete flooring 1:2:4 ( 1 cement: 2 coarse sand . : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate. (a) Crushed.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick.
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
Extra for Kota stone/ sand stone in treads of steps not exceeding 30cm in width.
Providing and fixing 1st quality ceramic glazed tiles conforming to IS :·13753 of minimum thickness 5 mm of approved make like NITCO, ORIENT, SOMANY KAJARIA, or equivalent make in all colour, shades except begundy, bottle green, black of any size as approved by Eningeerin- Charge in skirting, risers of steps and dados over 12 mm thick bed of Cement Mortar 1:3 ( 1 cement: 3 coarse sand) and jointing wtih grey cement slurry@ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying/ fixing Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 13755 of NITCO, ORIENT, KAJARIA, SOMANY or equivalent make in colour shades except White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick bed of Cement Mortar 1: 4 (1 cement: 4 coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to lS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of Tile 600x600 mm
Trimix Flooring Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
ROOFING Providing and laying gola 75x75mm in cement concrete M15 grade including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design in 75x75 mm deep chase.
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing on wall face unplasticised Rigid PVC RAIN WATER PIPES conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes. 110 mm diaMeter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Coupler 110 mm
Bend 87.5° 110 mm bend
Shoe (Plain) 110 mm Shoe
Deck Sheet Supplying and laying cold roll formed galvanized rofiled sheet of Tata/JSW/ Smartdek with the following specification: Base metal thickness of decking shall be 0.8 mm thick (11.34 kg/sqm) manufactured using S350 grade of steel with total galvanization of 275 gsm on both sides. The decking is produced in minimum of 60 mm profile depth. The decking is profiled with indentations to achieve adequate bonding with concrete to act as a composite deck complete as per direction of the Engineer-in-charge.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+/- 5 %) total coated thickness(TCT), Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated Jor L hooks, bolts and nuts and GI:Seam bolts, and nuts,GI plain and bitumen washers complete: Ridges plain (500 - 600mm)
FINISHING WORK 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand)
20 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
6mm cement plaster to ceiling of mix 1 : 3 (1 cement: 3 fine sand)
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
White washing with lime to give an even shade. New Work (three or more coats)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water tinnable priming coat with cement primer
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer.
Wall Painting with plastic emulsion paint of approved lj brand and manufacture to give an even shade. Two or more coats on new work
Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 litre/1 Osqm over and including base coat of water proofing cement paint applied@ 2.20kg/1 Osqm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete.
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
GRC Jali Providing and fixing Of UniStone Glass Reinforced Concrete (G.R.C) Screens in approved size, pattern, design, shade and thickness of 50mm on frame and design element in 30mm thick casted with layering technique Power Spray methodology have weight approximately between 3.5 – 4 Kg per Sq. Ft. and color.Make: Unsitone/ Equivalent
Providing and fixing Of UniStone Glass Reinforced Concrete (G.R.C) Moulding in approved pattern, design, shade and thickness. Length: Approx 110 Mtr. Height: 500 MM Depth: 250 mm.Make: Unsitone/ Equivalent
Providing and fixing GI hexagonal chicken wire mesh of size 12mm x22g at the junction of disimilar surfaces of brick masonry wall and R C C column by beams and the like including necessary nails for fixing etc, complete all as per specification and direction of Engineer -in -charge for all floor at all heights.
ROAD WORK Preparation of subgrade by excavating earth to an average of 22.5 em depth, dressing to camber and consolidation with road roller including making good the undulation etc. and disposal of surplus earth upto 50 m~tres.
Supplying and stacking of good earth at site, including carriage.
Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density).
Extra for providing and mixing hardening compound of approved quality as per manufacturer’s specification in cement concrete.
Providing and fixing in position pre-moulded joint filler in expansion joints.
Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade ‘A’ sealing compound.
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
PRIME COAT Surface dressing one coat on new surface with bitumen of specified grade at a rate of 1.95 kg/sqm. of surface area with 1.5 cum. of stone chippings 13.2 mm nominal size per 100 sqm. of road surface including consolidation with road roller of 6 to 8 tonne capacity , etc. complete : Using bitumen emulsion (minimum 50% bitumen content - RS grade conforming to IS : 8887).
TACK COAT Providing and applying tack coat using bitumen emulsion conforming to IS: 8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom. On bituminous surface @ 0.25kg/sqm.
PREMIX CARPETING Providing and laying Bitumen Penetration Macadam with hard stone aggregate of quality, size and grading as specified, with bitumen of suitable penetration grade including required key aggregate as specified, spreading coarse aggregate with the help of self propelled / tipper tail mounted aggregate spreader and applying bitumen by a pressure distributor and then spreading key aggregate with the help of aggregate spreader complete including consolidation with road roller of minimum 8 to 10 tonne capacity to achieve specified values of compaction and surface accuracy : For 50mm compacted thickness using coarse aggregate of size 50-20 mm graded @ 0.60 cum per 10 sqm key aggregate of size 12.5 mm graded @ 0.15 cum per 10 sqm. With paving asphalt grade VG - 10 @ 50 kg/10 sqm. (a) Quarry.
SEAL COAT. Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade VG - 10 and blinding surface with 0.90cum of stone aggregate of 6.7 mm size (Passing 11.2mm sieve and retained on 2.36mm sieve) per 100 sqm of road surface including rolling and finishing with power road roller all complete.
Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete. New work (Two or more coats)
Providing and laying at or near ground level factory made kerb stone of M- 25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge.
Rubber Column Guard : EPDM Rubber Profile , 1) 100 mm x 100 mm with curved corner. 20 mm thick, 1 RMT length with Yellow reflective stickers and screws Code: 40169, 990/ Equivalent
Arpitha Speed Humps : EPDM Rubber, Yellow & Black SIZE : Lenth 500 mm X Width 425 mm X Thickness 70 mm. Code: 4016, 9990/ Equivalent
Acrylic convex safety/Security mirror : 32”dia- durable & shatter resistant out door with Clamp. Code:3926/ Equivalent
DRAINAGE WORK Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 19.19.1 L D- 2.5 H D - 20 Circular shape 560 mm internal diameter
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin- charge.
ALUMINIUM WORK Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed echanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. Glazing and paneling to be paid for separately) :.Note: Contractor to prepare & submit Shop drawings for the approval from Consultant before commencement of work at site. For fixed portion. Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness
Filling the gap in between aluminium frame and adjacent RCC/Brickwork/ Stone Work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge Upto 5mm depth and 5mm width
External Structure Glazing Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels including: (a) Structural analysis, design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and proper fixing of structural glazing system with the RCC/ masonry/structural steel framework of building structure, using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacturer, as per the approved sealant design, within and all around the perimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete.
This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design checked and all the shop drawings vetted by the Principals of the structural glazing system. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge.
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12-6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer high performance heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.1) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.
(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.
WATER PROOFING Providing and laying APP (Atactic Poly Propylene Polymer) modified prefabricated five layer, 3rnm thick water proofing membrance, black finishing reinforced with non-woven polyester mat consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr/sq. mt. by the same membrane manufacture of density at 25*C, 0.87- 0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under.Joint strength in longitudinal and transverse direction at 23*C as 650/450 N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 1'50*C. Cold flexibility shall be upto -2*C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the ~- authorised applicator of the manufacturer of membrane.3 mm thick (for corrugated roof sheets)
Extra for covering top of membrane with Geotextile, 120gsm non woven, 100% polyster of thickness 1 to 1.25mm bonded to the membrane with intermittant touch by heating the membrane by Butance Torch as per manufactures recommendation {for Item No. 25.18 to 25.21}
Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction I expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete. Serrated with central bulb (225 mm wide, 8- 11mm thick)
150mm dia
200mm dia
RCC Beams 65mm dia.
160mm dia
180mm dia
RCC Walls 65mm dia.
160mm dia
180mm dia
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.esilient rubber lined single arch vibration eliminators suitable for raw water Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 70 m Head
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 900 lpm at 35 m Head
PIPES & ACCESSORIES Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 250 mm. dia
200 mm. dia (wall thickness = 6.3 mm)
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 40 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
200mm dia
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 200mm dia
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
200mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 65 mm dia
150 mm dia
200mm dia
250 mm dia
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A l ) as required :
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30m
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun Metal
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 3 way - 150 mm dia M.S. Pipe
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Pendent Sprinkler /pendent
Horizontal side wall sprinkler
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 150 mm dia
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required 150 mm dia
PUMPS ,HYDRANT AND AUTOMATIC SPRINKLER WORKS Supply, fabrication (as per code), installation, testing and commissioning of Pressure vessels 450mm diameter and 1000mm high fabricated from 8-10mm M.S. plate with accessories inside painting with epoxy paint and outside with enamel.
M.S. fire hose cabinet (2100x750x400 mm) made out of 16 gauge M.S. sheet capable of accommodating landing valve, hose pipes, fittings & accessories. The box shall have a front glass door with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) - for external and roof hydrant.
M.S. fire hose cabinet 750x600x250 mm) made out of 16 gauge M.S. sheet capable of accommodating landing valve, hose pipes, fittings & accessories. The box shall have a front glass door with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) - for external and roof hydrant.
Fire Axe as per good peactice .
Providing & fixing 80mm diameter MS Class 'C' diesel pump exhaust pipe includings all fittings, like bends, tees etc. clamps / structural steel supports. The pipe shall be provided with 75mm thick fiberglass insulation & covering the insulation with 500 g polythene sheet giving proper overlaps & sealing the joints with suitable adhesive compound. The pipe shall be provided with 24 gauge aluminium sheet cladding
Extinguisher Providing & Fixing of Fire ExtinguisherCO 2 type with Pressure Gauge , Discharge pipe , Valve Construction as per good parcice with Epoxy Powder coating ms Sheet metal thickness : 1.60MM and complete tested, Warranty 5 Years. Capacity 4.5 kg Fire Extinguisher
22.5 Kg. CO2 Fire Extinguisher
Providing & Fixing of Fire Extinguisher ABC type with Pressure Gauge , Discharge pipe , Valve Construction as per good parcice with Epoxy Powder coating ms Sheet metal thickness : 1.60MM and complete tested, Warranty 5 Years. 5.0 Kg. ABC Fire Extinguisher
5Kg Automatic ceiling mounted Fire Suppression Extinguisher Direct Low Pressure, Dupont™ Clean Agent FE 36 Zero ODP, Stored Pressure Type, fitted with Pressure Gauge, Discharge Time 32 Seconds approx, Applicable on class A, B, C and electrically started fires, With suitable support
Supplying and Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc, with charcoal/ coke and salt as required.
Supplying and laying 25 mm x 5 mm. G.I. strip in 40 mm dia. G.I. Pipe from earth electrode, as required.
Providing & fixing 25mm x 5mm G.I. strip on surface or in recess for connections etc. as required.
Providing and Fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing alongwith existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying, fabricating and installing following size of perforated M.S. cable trays, including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders and including paint 100 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Supplying of all materials and making terminations of 1.1 KV grade aluminium multicore cables of the following sizes. The work includes cable glanding using brass plated double compression glands, sizing the core leads, removing insulation, fixing suitable crimping type copper lugs/ thimbles by using hydraulic crimping tools with correct size of the dies, shaping the leads and neatly connecting the same to the equipment terminals. 3.5 Core 120 sq. mm. Armoured Aluminium cable.
3.5 Core 35 sq. mm. Armoured Aluminium cable.
4 Core 35 sq. mm. Armoured Aluminium cable.
4 Core 16 sq. mm. Armoured Aluminium cable.
4 Core 10 sq. mm. Armoured Aluminium cable.
4 Core 6 sq. mm. Armoured Aluminium cable.
FIRE ELECTRICAL WORKS (NON SCHEDULED ITEMS) Supplying of following sizes of 1.1 KV XLPE insulated, Aluminium conductor, armoured cables conforming to IS 7098 (Part-II) 3.5 x 120 sq. mm
3.5 x 95 sq. mm
4C x 6 sq. mm
3 c x 35 sq. mm
3 c x 25 sq. mm
3c x 16 sq. mm
3C x 10 sq. mm
3C x 6 sq. mm
Control Cabling (PVC insulated and PVC sheathed, armoured, Copper Conductor of 1.1 KV grade on existing cable trays). 5C x 1.5 Sq. mm
PLUMBING WORK SANITARY INSTALLATIONS Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
2 WC CONSODER Providing and fixing white vitreous china European type W.C. pan with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern,with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the wallsand floors wherever required: Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. White Agaria Marble Stone
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge..
Providing and fixing wash basin with C.I. brackets, 15 mm dia C PBrass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm
Providing and fixing PTMT Bottle Trap for Wash basin Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.
Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.(sink & urinal)
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms.
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 15 mm nominal bore
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing soil, waste, vent and rain water pipes Centrifugally cast (spun) iron S&S pipe 100mm dia cast (spun) iron S&S pipe
Providing and fixing MS holder bat clamps of approved design to cast iron (spun) pipe embedded in and Including cement concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. For 100mm dia. Pipe
Providing and fixing cast iron trap of self cleansing design with cast iron screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors. 100 mm inlet and 100 mm outlet centrifugally cast (spun) iron S&S.
Making khurras 45x45cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) over PVC sheet 1m x 1m x 400 micron, finished with 12mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement, rounding the edges, making and finishing the outlet complete
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing plain bend of required degree. 100mm dia
Providing and fixing single equal plain junction of reqd. degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 100x100x100mm Standard cast (spun) iron pipe IS-3989
Providing and fixing collar. 100mm Centrifugally cast (spun) iron pipe S&S
Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead : 100 & 150 mm diameter pipe
Providing and fixing PTMT grating of approved quality and colour Circular type 100 mm nominal dia
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) alround SW including bed concrete as per standard design Note: This work shall be done all-round CI pipe at ground floor's toilet. 100mm diameter
Providing and fixing G.I. Pipes complete with G.I. Fittings and clamps. including cutting and making good the walls etc. required for waste connection from W.B., A.S.P., Sump Rising main etc. Complete. 40mm nominal bore
50 mm nominal bore
Painting G.I. Pipes and fittings with two coats of anticorrosive bitumastic paint of approved quality 40 mm nominal bore
50 mm nominal bore
Supplying and fixing C.I. cover without frame for manholes : 560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg
Providing & fixing on wall face unplasticised -Rigid PVC rain water pipes conforming to IS:13592 Tyape A included jointing with seal ring conforning to IS:5382 leaving 10 mm gap for thermal expansion. (i)Single socketed pipes. 110 mm diameter
Providing, fixing on wall face unplasticised - PVC moulded fittings /accessories for unplasticised - Rigid PVC rain water pipes conforming to IS ; 13592 Type A including jointing with seal ring conforming to IS ; 5382 leaving 10 mm gap for thermal expansion. Coupler -110 mm diameter
Bend -87.5 deg -110 mm diameter
Shoe -110mm shoe
Providing & Laying Ductile Iron Double Socket 22.5°Bends conforming to IS-9523/2000 having dimension as per table 17 of IS-9523/2000 in the nominal diameter/sizes with external bitumen coating and internal cement mortar lining. (laying conforming to IS 12288 : 1987) for ceiling rain water pipe. 150 mm diameter
Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design.
Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. Internal work -Exposed on Wall 25 mm nominal outer dia pipes
32 mm nominal outer dia pipes
Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the wall same including testing of joints complete as per the direction of engineer incharge concealed work including cutting chases and making good the wall etc. 15 mm nominal outer dia pipes
20 mm nominal outer dia pipes
Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. (internal work) exposed on wall. Exposed on wall 32 mm dia, nominal bore
Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality 32 mm dia, nominal bore
Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 25mm dia, nominal bore
32 mm dia, nominal bore
Structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) 32mm nominal bore
SEWERAGE NETWORK Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil up to 1.50 m depth Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Constructing brick masonry manhole with F.P.S. bricks in cement mortar 1 : 4 (1 cement : 4 coarse sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat of neat cement complete as per standard design Inside size 90 x 80 cm & 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimension total wt. of cover & frame to be not less than 38 kg (wt. of cover 23 kg and wt. of frame 15 kg)
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS : 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing square mouth SW gully trap grade ‘A’ complete CI grating brick masonry chamber with bricks of class designation 75 and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. (COVER MIN. 4.5 KG & FRAME MIN.2.7 KG ) 150x100mm size P type With FPS bricks
Providing and laying non-pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. (for storm drainage) 250 mm dia RCC pipe
Providing and laying in position cement concrete of grade excluding the cost of centering and shuttering - all work up to plinth level 1:5:10 (1 cement : 5 coarse sand : 10 graded ston aggregate 40 mm nominal size)
Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:5 (1 cement : 5 fine sand) including 500 x 450 mm (heavy duty) precast RCC horizontal grating with frame complete as per standard design: with FPS bricks
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement cincrete 1:2:4 mix (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar 1:3 (1cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete for pipes 100 to 230mm dia.
SEWERAGE NETWORK RAIN WATER HARVESTING Earth work In excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth. 1.5m in width as per as 10 sq.m on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering , lead up to 50 m and lift up to 1.5m.
Extra for every additional lift of 1.5 m or part there of in: All kinds of soil.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo Mechanically Treated bars.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand)
12 mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand).
Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete: 200 mm diameter
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer –in-charge.
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality L D- 2.5 Rectangular shape 600x450mm internal dimensions
RAIN WATER HARVESTING Providing and fixing horizontal type storage hot water heater within-built pressure relief valve, rated for inlet water pressure upto 6 bar complet in all respects including inlet, oulet connections, fixing bolts etc. and testing complete.
Sump Pumps Supply & Installation, testing and commissioning of centrifugal non clogging submersible sump pumps for plant room drainage. Pump capable capable of handling 25 mm dia soft solids. Motor suitable for 415 + 10% volts, 3 phase, 50 Hz AC Power supply. Pumps shall be suitable for automatic/manual operation (Overall depth of sump – 1.5 M). Submersible sump pump shall be provided with dry running protection. Inclusive of supporting arrangement for stationary type. Two nos. of pump installed in one sump pit 1 working & 1 standby with automatic/manual opration as requireds. Waste Water Drainage Sump Pump Flow rate : 2 LPS Head : 10 Mtrs. Min. Motor HP : 2.0 (Each)
Sewage Sump Pump Flow rate : 2 LPS Head : 10 Mtrs.
HVAC WORKS VENTILATION WORKS Basement Parking Ventilation Fan Sections: Supply,instllation,testing and commissioning of Exhaust air Fan section in double skin (0.8 mm each) construction with sandwiched insulation with pre filters, AMCA certified backward curved DIDW,fan with IE-2 . Motors shall be suitable for 415+10% volts, 50 cycles , 3 phase AC supply and suitable for operating through VFD. Fans shall be activated from fire signal from fire alarm system .The fan shall be equipped with mounting bracket,outlet core required at discharge and vibration isolator for fixing arrangement of the fan.Fan shall also be provided with flexible fire proof flexibel connection at outlet.The fan shall be low RPM (less than 1500 RPM) and capacities based on static pressure mentioned below or to suit the system.Motor with class H insulation, motor shall be high temperature resistant smoken spill. The unit shall be complete with all accessories etc.All the above exhaust air Fan sections/Motor shall be fire rated minimum 300 Degree Celcius for 2 hours).Quote price should be inclsive of Backdraft damper per fan Approved Make: Zeco/Edgetech/VTS/Greenek) 22,000 cfm at 65 mm static
Axial flow Fan for Fresh Air in Basement : Supply, Installation, Testing & Commissioning of GSS long casing (Motor should completely coverd in fan casing) Tube Axial flow type fans complete with dual speed , aluminium alloy blades with aerofoil design, Sound Attenuator & gravity louvers at inlet. Motor shall be of 415 + 10% volts, 50 Hz. Sound level at 3mt distance from fan outlet shall not be more than 80db(A) (Room Condition). Capacity shall be as follows & as per detailed technical specification: Fans should be AMCA certified. RPM Should Not exceed 1450.However lower CFM fans upto 5000 CFM can be provided at 2850 Rotations per minute. Outlet velocity shuld not exceed 15 m/s of below capacities.Quote price should be inclsive of Backdraft damper per fan. 22000 cfm at 35 mm static Approved Make:(Schneider/ABB)
VFD for Exhaust Fan: Supply,instllation,testing and commissioning of VFD compatible with Exhaust fan and Fresh air fan Motor Ramp up and down based on CO level and Fire mode work with Full Speed. 11 KW
Supply and installation of CO SENSOR & DETECTOR UL 2034 /NFPA CO detector to be installed flush mounted hard wired to Panels and with battery back up. Each Sensor shall have Output Terminals: (Screw Type) 1. 24 V AC/DC 2. Power grounding 3. O/P 1 Linear signal CO transmitter 4. O/P 2 Linear signal CO2 transmitter (Built in option) 5. O/P 3 – Gas alarm (NC) 6. Jumpers to choose between open or 10V signal; voltage or current outputs 7. Jumper for configuring the linear output 0% or 20 % start point. 8. UART port Sensor Electrical/Mechanical/Dimensions: Power Input 24 VAC/VDC±20%, 50 Hz (half-wave rectifier input);Power Consumption < 3 Watts average; Wiring Connections max 1.5 mm2 wires for screw terminal (main terminal) and spring loaded terminal; UART connector 5-pin, 2.54 mm pitch & slide connector CO Measurement : Operating Principle Gas sensitive thick film material (MMOS) internally compensated for temperature and humidity variations, with active carbon filter with Automatic Baseline Correction (ABC) 3 Accuracy 4± 10 ppm: Measurement ranges 0 to 200 ppm General Performance : Compliance with EMC directive 89/336/EEC; Operating Temperature Range 78oC to +50°C;Storage Temperature Range -20 to +70 °C; Operating Humidity Range 0 to 95% RH (non-condensing); Warm-up Time ≤ 15 minutes (more when un-powered for a long time); Step response (T1/e) 8 minutes 2; Expected Life Time - 7 to 10 years Self Diagnostics complete function check of the sensor.
Supply,instllation,testing and commissioning of Fresh air Fan section with front discharge in double skin (0.8 mm each) construction with sandwiched insulation with pre filters, AMCA certified bachward curved DIDW,fan with IE-2 . Motors shall be suitable for 415+10% volts, 50 cycles , 3 phase AC supply. Fans shall be activated from fire signal from fire alarm system .The fan shall be equipped with bird screen,mounting bracket,outlet core required at discharge and vibration isolator for fixing arrangement of the fan.Fan shall also be provided with flexible fire proof flexibel connection at outlet.The fan shall be low RPM (less than 1500 RPM) and capacities based on static pressure mentioned below or to suit the system.The unit shall be complete with all accessories etc. 10000 CFM at 35mm (Staircase prussiation)
9500 CFM at 35 mm (Lift Well)
Supply,instllation,testing and commissioning of Star delta starter panel with neccssery accoseries panel should have fire alram input. 7.5 KW
Supply,instllation,testing and commissioning of cabinet type exhaust fan with all accesseries as follow the capacity. 1200 cfm at 25mm
600 cfm at 25mm
SUPPLY OF LT CABLES Supplying of following sizes of 1.1 KV XLPE insulated, Aluminium conductor, armoured cables conforming to IS 7098 (Part-II) 4 x 25 sq. mm
4 x 16 sq. mm
4 x 10 sq. mm
4 x 6 sq. mm
DSR- VENTILATION WORKS Rectangular GSS Ductwork : Supply,installation,balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets,elbows splitter,dampers,vanes,hangers,supports etc.as per approved drawings and specifications of following sheet thickness complete as required. (Approved Make:Ductofab/Aerotech/Rolastar) 24 Gauge (thickness 0.63mm sheet)
22 Guage (thickness 0.80mm sheet)
20 Guage (thickness 1.0mm sheet)
18 Guage (thickness 1.25mm sheet)
Grilles/Diffusers/Louvers/VCDs/FDs : (Approved Make:Caryaire/Green/Air/Coneaire) Supply, installation, testing and commissioning of Aluminium powder coated grilles without dampers For Exhaust as per drawings and specifications.
Supply, installation, testing and commissioning of Aluminum powder coated Exhaust air Louvers with bird screen but without dampers for basement Exhaust
Supply,installation,testing and commissioning of GI Volume Control Dampers with its body,blades and all required accessories as per drawings and specifications
MV CABLE JOINTING & END TERMINATION Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 25 sq. mm
4 Core 16 sq. mm. Armoured Aluminium cable.
4 Core 10 sq. mm. Armoured Aluminium cable.
4 Core 6 sq. mm. Armoured Aluminium cable.
ELECTICAL HIGH SIDE EARTHING Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required.
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required.
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection / termination with GI thimble etc. as required.
Providing and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required.
MV CABLE LAYING Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
HT CABLE LAYING Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm
MV CABLE JOINTING & END TERMINATION Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 120 sq. mm
4 X 25 sq. mm
4 Core 16 sq. mm. Armoured Aluminium cable.
4 Core 10 sq. mm. Armoured Aluminium cable.
4 Core 6 sq. mm. Armoured Aluminium cable.
HV CABLE JOINTING & END TERMINATION 11 KV CABLE JOINTING Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 240 sq. mm
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 240 sq. mm
SUPPLY AND INSTALLATION OF DIESEL GENERATOR SET Supply & Installation, Testing and commisioning loading unloading of sound attenuated weather proof type DG set of Ashok Leyland / Cummins / Kirloskar / make engine and KEC / Leroy Somer alternator suitable for 3-phase, 415 volts, 50 Hz, 1500 RPM, Prime Power rated output, Radiator cooled, with MS, medium class piping, cold start, suitable for remote starting, Diesel Generator Set.The Engine shall include flywheel to suit direct coupling with guard, air cleaner, blower fan, radiator, fuel pump, electronics governor, fuel filter, lub oil filter & pump, battery charger, 12/24 volt, automotive batteries of compatible capacity and instrument panel comprising of switch with key, etc. as required. The alternator shall be brushless,self excited, self regulated,drip proof, and continuously rated at 0.8 pf suitable for 3 phase 415 volts 50 cycles, 4 wire system, class 'H' insulation provided with static excitation unit, Protection, etc as required. The overload capacity shall be not ne less than 110% of rated capacity for 1 hour in every 12 hours. The DG set in sound attenuated enclosure shall be mounted on a fabricated rigid common base frame with resilient anti-vibration mountings including associated foundation/masonary work to provide 90% vibration isolation efficiency. The DG Set shall include all accessories, fittings, instruments etc complete as per specifications and as required. DG set design temp. will be 50 deg C. Fuel tank will be located inside Sound proof Enclosure. Engine with all auxiliaries coupled with Alternator complete with AVR & accessories Starting Battery, Battery cable, engine driven battery charging , alternator, including stand-alone mains powered battery float charger complete with relays, controls and indicators
The extended exhaust piping of 125 mm to collect & expel exhaust gases from engine cylinders, for the DG set, including turbo chargers, flexible connectors, 50 mm thick rock wool lagging with chicken mesh and 24 gauge aluminium cladding, elbows, horizontal / vertical pipe supports, thimble with spray shield / rain cap etc., as per standards / CPCB norms. Acoustic housing suitable for thermal and noise level insulation as per relvevant code of practices. It shall be ensured that dB level as per relevant class shall be 75 dB at a distance of 1m from the equipment. 1 no. AMF controller to start the DG set automatically in case of grid supply outage and disconnect the MCCB as soon as the power supply is restored. The AMF controller shall be of Deep sea electronics or equal. Capacity - 160 Kva
Providing & fixing 100 mm diameter MS Class 'C' diesel pump exhaust pipe includings all fittings, like bends, tees etc. clamps / structural steel supports. The pipe shall be provided with 75mm thick fiberglass insulation & covering the insulation with 500 g polythene sheet giving proper overlaps & sealing the joints with suitable adhesive compound. The pipe shall be provided with 24 gauge aluminium sheet cladding Note : DG sets shall be complete with the following : a. Four pole 250 AMP,MCCB of required rating inside the enclosure.
SUPPLY OF CONTROL CABLES AND SAFETY EQUIPMENT CONTROL CABLES (Tentative cable schedule) 1.1kV grade copper control cables 2C x 4Sq.mm YRY Cu-Conductor armoured cable
16C x 2.5Sq.mm YRY Cu-Conductor armoured cable
4C x 2.5Sq mm Cu Conductor armoured cable
3C x 1.5 Sqmm YRY-Cu Conductor shielded cable
Termination for the above 2C x 4Sq.mm YRY Cu-Conductor armoured cable
16C x 2.5Sq.mm YRY Cu-Conductor armoured cable
4C x 2.5Sq mm Cu Conductor armoured cable
3C x 1.5 Sqmm YRY-Cu Conductor shielded cable
SAFETY ACCESSORIES & MISCELLANEOUS 1.1kV class-1 approved tested quality rubber mat of 6mm thick and 900mm wide and 1800mm long,
A1 size drawing display board with laminated drawings
Shock treatment chart in English and local language duly framed with glass cover
Danger Boards in English and local language
4.5Kg Class CO2 type portable fire extinguisher
First aid box complete with all standard first aid materials
Set of two sand buckets with stand
SUPPLY & INSTALLATION OF PIPES Providing and laying in position the following size of Hume Pipes (NP3 duty) in road crossing and paved area, including collars, joints filled with cement mortar 1:4 (1 cement : 3 coarse sand : 6 crushed stone aggregate 20 mm and down gauge) all round the pipes laid compact and finished smooth complete including sand cushioning at cable entry, etc. 100 mm dia.
Supply and Laying in position the following size of double wall corrugated pipe conforming to IS 14930. The pipes shall be laid under ground at required depth by excavation and then back filling compacted and finished smooth complete including sand cushioning at cable entry, etc. 63/51 mm (OD/ID)
SUPPLY OF LT & HT CABLES Supplying of following sizes of 1.1 KV XLPE insulated, Aluminium conductor, armoured cables conforming to IS 7098 (Part-II) 3.5 x 120 sq. mm
3.5 x 95 sq. mm
3.5 x 70 sq. mm
4 x 25 sq. mm
4 x 16 sq. mm
4 x 10 sq. mm
4 x 6 sq. mm
Supply, receiving, storing, handling, laying, testing and commissioning of the following sizes of 11 KV XLPE (E) Grade aluminium individual core screened extruded inner sheath, flat steel strip armoured PVC sheathed cable in cable trenches or in hume Pipes as per specifications. 11 KV, 3C x 240 Sq. mm XLPE Aluminium cable.
SUPPLY AND INSTALLATION OF LT PANEL MAIN LT PANEL Supply & Installation, Testing and commisioning loading unloading of Main LT PANEL, mounted, indoor cubicle type, IP-42 degree of protection made out of 2.0 mm CRCA sheet, powder coated comprising the following. Meter board shall be provided with window for meter reading. Incomer 1 NO. 250 Amp, 4P Auto Transfer switch 1 No 250 Amp TPN MCCB (25 kA) Phase indicating lamp with backup MCB's. ON / OFF / Trip indicating lamp. 1 No. type 1+ 2 surge Arrester Bus Bar 300 Amp TPN Aluminium bus bar of required length covered with heat shrinkable PVC colour sleeves Outgoings 2 No. 250 Amp 4P MCCB's (25 kA) 8 Nos. 40 Amp 4P MCB's (10 kA) 4 Nos. 63 Amp 4P MCB's (10 kA) 3 Nos. 25 Amp DP MCB's (10 kA) 50 KVAR CAPACITOR PANEL with suitable AFCR 1 No. 125 Amp 4P MCCB's (25 kA) for capacitor panel incomer
2 Nos.12.5 KVAR MPP type capacitors with associated 63 Amp TP MCCB's, AC3 duty contactors with each capacitor bank and 4 step relay for automatic and manual operation of capacitors, necessary indication lamps / toggle switch etc and required inter connections complete 2 Nos.10 KVAR MPP type capacitors with associated 63 Amp TP MCCB's, AC3 duty contactors with each capacitor bank and 4 step relay for automatic and manual operation of capacitors, necessary indication lamps / toggle switch etc and required inter connections complete 1 Nos.5 KVAR MPP type capacitors with associated 63 Amp TP MCCB's, AC3 duty contactors with each capacitor bank and 4 step relay for automatic and manual operation of capacitors, necessary indication lamps / toggle switch etc and required inter connections complete Main Distribution Board (MDB) as described above.
VENTILATION PANEL Supply & Installation, Testing and commisioning loading unloading of ventilation panel, mounted, indoor cubicle type, IP-42 degree of protection made out of 2.0 mm CRCA sheet, powder coated comprising the following. Meter board shall be provided with window for meter reading. Incomer 250 Amp TPN MCCB (25 kA) Phase indicating lamp with backup MCB's. ON / OFF / Trip indicating lamp. Bus Bar 300 Amp TPN Aluminium bus bar of required length covered with heat shrinkable PVC colour sleeves Outgoings 6 No.100 Amp 4P MCCB's (16 kA) Main Distribution Board (MDB) as described above.
ELECTICAL LOW SIDE WIRING IN STEEL AND PVC CONDUIT Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (loop points)
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (loop points)
2 X 4 sq. mm + 1 X 4 sq. mm earth wire (loop points)
2 X 6 sq. mm + 1 X 6 sq. mm earth wire (DB Submain)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc, as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 150mmX150mmX60mm deep
200mmX150mmX75mm deep
200mmX250mmX75mm deep
250mmX300mmX100mm deep
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
TV antenna socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connection etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
MCCB, MCB & DB'S Supplying and fixing following way, single pole neutral, sheet steel MCB distribution board, 240 V, on surface/recess complete with tinned copper bus bar, earth bar din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 12 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Double pole
Supplying and fixing single pole blanking plate in the existing MCB DB comlete etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current upto 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 A
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 V, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 415 V, TPN industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
CABLE TRAYS Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
EARTHING Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
MISC.CIVIL ITEMS Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 meters.
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 150 mm dia
LED TUBELIGHT (Havells REGAL BATTENT 8UPTO 2 x 22WSSBSWH) ( PARKING)
LED TUBELIGHT (Havells REGAL BATTENT 8UPTO1X22WSSBSWH) (ELECT ROOM/LMR)
SURFACE/ RECESSED LIGHT FIXTURE (Havells INTEGRANEOSURFA CEDLS15WLED857S)( STAIR/LIFT LOBBY & TOILET)
LED BULKHEAD (Havells RUGBYNEONFT10WLED860SSYMTOPC) (terrace & lift) (for common area)
1200 mm Sweep Decorative Ceiling Fan.
150 mm-450mm Sweep Exhaust Fan with louvers
35 Watt Arm type LED light fixture
3 Meter GI Pole for fixing of 35Watt Arm type LED light fixture and along with
Entry and Exit light
SUPPLY OF DATA SOCKETS Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Data socket outlet (RJ45
DWC PIPES & MANHOLES Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Providing & making manholes chambers with clear inner dimensions with 230/345 thick first class bricks wall with paster inside/outside with PCC flooring minimum 75 mm thick including heavy duty cover RCC cover with frame etc complete with neat cement 600mmX600mmX800mm
Structural Steel For Cable Tray Support Supply, Laying & fixing of MS supports fabricated from steel flats, angles, bars, channels as required for fixing/hanging cable trays duly painted with one coat of primer and 2 coats of synthetic enamel paint of approved colour etc. complete as required.
INVERTER FOR EMERGENCY LIGHTING Supply, installation, testing and commissioning of 2 KVA SINE WAVE Inverter alongwith lead acid batteries CSB/Exide make giving 90 minutes back up alongwith powder coated cabinet for housing the inverter and batteries, complete as required and as per specif
CCTV SYSTEM Supply, Installation, Testing & Commissioning of Indoor type day/night capability. Camera shall have 2- 4mm mm Fixed lens including providing and fixing of Pendant mounting bracket for camera and all necessary hardwares as required for fixing.
Supply, Installation, Testing & Commissioning of Bullet type day/night capability. Camera shall have 2- 4mm mm Fixed lens including providing and fixing of Pendant mounting bracket for camera and all necessary hardwares as required for fixing.
Supply, Installation, Testing & Commissioning of 16 channel, IP Camera Support, hardware Network Video recorder , having HDD slots with 1 eSata port, each slot 2 TB HARD DISK, redundant SMPS, complete with suitable capacity of HDD to store 30 days back-up data for 16 cameras, including Video Management software enables security related personnel to easily and remotely gather video evidence, monitor live situations, and configure and maintain a video surveillance system over Ethernet consisting of digital video recorders (DVRs), hybrid digital video recorders, network video recorders (NVRs), analog video cameras, and IP video cameras, should support Detachable Viewers, WAN connectivity and should support digital zoom in defined area.
Supply, Installation, Testing & Commissioning of suitable Rack with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and accessories as mentioned in the BOQ above
Supply, Installation, Testing & Commissioning of 24 inch Full HD LED commercial grade monitors.
CABLES & WIRING Supply & laying of CAT 6 cable for communication in suitable size of conduit.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
FIRE DETECTION AND ALARM SYSTEM Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system ( which is part of the scheduleof work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol Bacnet/ Modbus over IP complete as per specifications
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required..
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supplying, installation, testing & commissioning of monitor module complete as required.
17.5 CABLING & WIRING Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supply & laying of 2C X 1.5 sq.mm FRLS PVC insulated wire
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
BOOM BARRIER SYSTEM Supplying, installation, testing & commissioning of Hydraulic operator with 3 meters barriers speed is under 1.4 seconds. With all controler, cabling , supporting, startor, control panel all accessories.
EXTERNAL & INTERNAL SIGNAGES Branding hanging sign with ms frame. Providing and fixing of exterior signage to be fixed with the wall, cesderniers to be made of PURE Acier inoxydable and raising by 4", duly cut by laser machine. the front side glow by 3 mm white acrylic to be laser cut and raising by 3mm clear acrylic . the letters front to be 3M vinyl. The signage shall illuminated with back lit LED GE of 1.5 watt each module, make (certificate to be provided, by the makers of LED), complete in all respects. MULTI LEVEL CAR PARKING; recomended size: 75' x 4'. This signage will be hang from terrace wall with MS frame od 2"x1", all ms will be painted by RAL paint.
Staircase There will be etsaus over pure acier inoxydable, sign 12" x 12” :
Lift No. There will be etsaus over pure acier inoxydable Size 24"x9".
Lift lobby There will be etsaus over pure acier inoxydable. Double sided, Size 24"x9".
Fire exit led sign This Signage will be fixed near stairs. CNC Router cut engraving on 8 mm Acrylic + Led light + Battery backup + MS Box for ceiling Signage will be fix with ceiling.
In case of fire do not uses lifts. There will be etsaus over pure acier inoxydable, Size 18"x18".
Toilet sign for doors There will be etsaus over pure acier inoxydable, sign 15" x 9”:
Floor sign There will be etsaus over pure acier inoxydable, Size 24"x24".
Ceiling Suspended Double Side; DIRECTIONAL SIGN, non lit: This will be digital printing over 3M vinyl, 3M fluoroscent vinyl and pasted over 4mm acrylic. Size 48"x18".
Danger or Caution signage; wall mounted. This will be digital printing over 3M vinyl and pasted over 4mm acrylic. Size 18"x18".
Evacuation Plan in floors; wall mounting This will be digital printing over 3M vinyl and 3M fluoroscent vinyl and pasted over 4mm acrylic. Size 36"x24".
Beam no. for car parking. HERE Laser cut 4mm colored acrylic , wall mounted by screw, non lit sign. Size of each letter 12"x9"
LIFT Supply, installation, testing and commissioning of the following Jhonson / ThyssenKrupp's/Otis Equivalent make elevators as per specifications. Passanger Elevator SUKRANTI/ 15 PASSENGER LIFT/ 1020 Kgs / 6 stops / STAINLESS STEEL (1.5 mm) Car Cabin Jhonson /Thyssenkrupp's/ Equivalent machine room less type with 1.00 m/s speed, 7 stop & 7 opening & 15.00 meter travel height Aprox ,Centre Opening Sliding Door - Stainless Steel (1.5 mm) -Moonrock
A B ENTERPRISES
Bidder Name
A B ENTERPRISES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.05 MB
ARCHITECTURE_ParkingLeh.pdf
Other Document • 8.25 MB
STRUCTURE_ParkingLeh.pdf
Other Document • 11.09 MB
SBDE113MLCP.pdf
Tender Documents • 0.41 MB
ELECTRICAL_ParkingLeh.pdf
Other Document • 6.27 MB
BOQ_206915.xls
BOQ • 0.59 MB
FIREFIGHTING_ParkingLeh.pdf
Other Document • 6.83 MB
HVAC_ParkingLeh.pdf
Other Document • 5.55 MB
Download all tender documents and submit your bid