Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.3 LAccepted-AOC | ₹47.3 L Quoted ₹48.9 L | L1 | Accepted-AOC Being First Lowest |
| 2 | L2₹51.4 L+₹2.5 L (5.14%)Rejected-Finance | ₹51.4 L+₹2.5 L (5.14%) | L2 | Rejected-Finance Other Than First Lowest |
| 3 | L3₹55.3 L+₹6.4 L (13.1%)Rejected-Finance | ₹55.3 L+₹6.4 L (13.1%) | L3 | Rejected-Finance Other Than First Lowest |
| 4 | L4₹59.6 L+₹10.7 L (21.9%)Rejected-Finance RM 01 RIDHISIDHI I SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | ₹59.6 L+₹10.7 L (21.9%) | L4 | Rejected-Finance Other Than First Lowest |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
16 Aug 2021, 6:00 pmClosed
GE Lalgarh Jattan
GE Lalgarh Jattan
SPECIAL REPAIR/RENOVATION OF STAFF QUARTERS OF KV AT LGJ MIL STN
2021_MES_453027_2
8932-09/21-22
Open Tender
Civil Works
Item Rate
180 days
GE Lalgarh Jattan
Class D cat a(i) b(i)
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹96,000
Yes
9 Sept 2021
24 Jul 2021
19 Aug 2021
24 Jul 2021
16 Aug 2021
31 Jul 2021
Amount
Taking down chowkhats or frames with shutters without taking off shutters from the frames, area exc 1.50sqm but n.exe 4.0sqm each and removal to store including cutting holes for removal of hold fast complete all as specified and directed by Engineer-in-Charge
Taking down chowkats or frames with shutters without taking off shutters from the frames, area n.exc 1.50 sqm each and removal to store including cutting holes for removal of hold fast complete all as specified and directed by Engineer-in-Charge
Taking down shutters of exc 1.0 sqm and but n. exc. 2.0 sqm each and removal to store including cutting complete all as specified and directed by Engineer-in-Charge
Taking down Steel/Wood window and ventilator chowkats or frames with shutters without taking off shutters from the frame of any description and any types with grill/without grill, removal to store including cutting holes for removal of hold fast complete all as specified and directed by Engineer-in-Charge
S&F 35 mm thick plain framed paneled shutters (any number of panels) with lock rail and panel of 9mm BWP commercial ply or 12mm thick veneered particle board with commercial veneering on both faces including moldings fixed to chowkats, of 2nd class Hard wood factory made shutter complete all as specified and directed by Engineer-in-Charge
S&F 35 mm thick and 2nd class Hard wood factory made Glazed and skeleton shutters, open rebated and prepared to receive glass/ gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed by Engineer-in-Charge .
S&F Factory made PVC single door frame of size 50x47mm with a wall thickness of 5mm plain colour sheet reinforced with 19mm x 19mm MS square tube having wall thickness 19 gauge complete all as shown in sketch on page 150 of SSR 2004 part-II. The door frame to be fixed to the wall using MS screw 75mm long with PVC fastener complete as per manufacturing, instruction complete all as specified and directed by Engineer-in-Charge
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed by Engineer-in-Charge.
S&F 100mm long butt hinges mild steel medium weight cold rolled ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F continous (piano) hinges 30mm width of flaps (when open) in mm, mild steel, bright finish or electrogalavanised complete all as specified and directed by Engineer-in-Charge.
S&F 125mm long extraded aluminum handles fabricated type anodized, ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F 200mm long aluminum anodized barrel tower bolt of extrude section ISI marked complete all as specified and directed by Engineer-in-Charge .
S&F mild steel 300mm ordinary rat tail rod pattern springs (ISI marked) including roller and roller plate complete all as specified and directed by Engineer-in-Charge
S&F 300mm long mild steel sliding bolts, stove enameled black, with bright bolt not less than 12mm dia complete all as specified and directed by Engineer-in-Charge.
S&F steel windows with side hung shutters incl projecting type hinges with steel handle and peg stay with glazing bars, dovetailed or welded complete all as specified and directed by Engineer-in-Charge.
S&F steel windows with side hung shutters incl projecting type hinges with steel handle and peg stay without glazing bars, dovetailed or welded complete all as specified and directed by Engineer-in-Charge
S&F steel ventilator with top hung shutters incl projecting type hinges with steel handle and peg stay with glazing bars, dovetailed or welded complete all as specified and directed by Engineer-in-Charge
S&F MS work as in grills, grating etc with ends of bars shouldered and riveted framed guard bars, barred iron doors, ladders conforming to FE 410-0 or 310-0 complete all as specified and directed by Engineer-in-Charge
S&F farmed work as in cooler stand, & door chowkhat of angles iron or other section complete , Fe-410-w (Grade E-250) complete all as specified and directed by Engineer-in-Charge.
S&F Aluminium alloy, anodised, 150 mm long of sliding bolt for cup board with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed byEngineer in Charge.
M&L for PCC 1:3:6 type C1 using 20mm graded mechanically crushed stone aggregate as in blocks of hold fasts etc including necessary form work as required complete all as specified and directed by Engineer-in-Charge
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone concrete or bricks surrounds, glazed with putty or fixed with beads and S/F of 4mm thick ness sheet glass, each pane n.exc. 0.5sqm. complete all as specified and directed by Engineer-in-Charge
S&F 4mm thick sheet glass, ordinary quality in square not exc 0.5 sqm in each pane fixed with oil putty or wooden beads & leaving the panes clean on completion complete all as specified and directed by Engineer-in-Charge.
S&F galvanized mild steel wire cloth 1.18mm average width of aperture and 0.56mm nominal dia of wire fixed with tinned tacks or galvanized wire staple complete all as specified and directed by Engineer-in-Charge
S&F as in repairs galvanized mild steel wire cloth 1.18mm average width of aperture and 0.56mm nominal dia of wire fixed with tinned tacks or galvanized wire staple complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick or concrete or stone walls/riser/dado surface including racking out joints, hacking for keys, scrubbing down with water etc complete all as spd and directed complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick plaster in CM 1:4 on brick or concrete wall & shaft external surface of any description finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge
M&L for 10mm thick plaster in CM 1:6 on brick or concrete wall internal surfaces of any description finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for 5mm thick plaster in CM 1:3 on concrete ceiling surfaces of any description finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge
M&L for 20mm thick plaster in CM 1:3 on concrete surfaces in two layers RCC chajjas/ceiling, surfaces of any description finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge
Demolition of cement concrete (un reinforced) in ground floors and paving not exc 15cm thick below or above ground level complete all as specified and directed by Engineer-in-Charge.
M&L for 40mm thick PCC 1:2:4 type B-1 using 20mm graded mechanically crushed stone aggregate as in floor and finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L 20 mm thick granite ( in any type) tiles machine cut bedded in vertical surfaces such as skirting /dados etc laid over 10mm thick rendering/screed bed CM 1:3 and jointed with grey cement slurry and pointed with white or colour cement with admixture of pigment to match the shade of granite stone including cutting and polishing complete all as specified and directed by Engineer-in-Charge.
M&L joint free non-skid ceramic coloured tiles 1st class of size area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm,7 to 8mm thick in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over 15mm thick screed in CM(1:6) complete all as specified and directed by Engineer-in-Charge
Materials & labour for 25mm thick PCC 1:2:4 type B-0 using 12.5mm graded mechanically crushed stone aggregate as in sub floor to receive topping complete all as specified and directed by Engineer-in-Charge.
M&L joint free glazed ceramic coloured tiles 350x 250x 7mm/ 450X 350X 7mm mm thick, on vertical surfaces such as skirting/dado/risers to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over 10mm thick rendering in CM(1:4) complete all as specified and directed by Engineer-in-Charge.
M&L for 20 to 25 mm thick machine cut kota stone slabs of suitable size of kota stone 22x22 inch as in floors bedded in grey jointed, pointed in coloured cement over 20mm thick screed bed CM 1:6 incl rubbing and polishing complete all as specified and directed by Engineer-in-Charge.
M&L for 20 to 25 mm thick machine cut kota stone slabs of suitable size, bedded and jointed in grey cement, pointed in coloured cement, over 10mm thick screed in CM(1:3) incl cutting/rubbing & polishing all as specified as in vertical surfaces/riser/stair steps as in skirting/dado complete all as specified and directed by Engineer-in-Charge
Supply & fixing 3mm thick, 38mm wide glass divided strips and insert in floor to the design as directed by Engineer in Charge (in Item no. 29) complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel water tubing 15mm bore including fittings, fixed in walls or embedded in walls/cement concrete including demolition of concrete etc complete all as specified and directed by Engineer-in-Charge.
,---ditto--- all as per serial item No 40 here-in-before but 20mm bore complete all as specified and directed by Engineer-in-Charge.
Refixing old steel tubing 15mm bore including fittings and connections in new or old position (walls, ceiling, floors etc) complete all as specified and directed by Engineer-in-Charge.
Refixing old steel tubing 20mm bore including fittings and connections in new or old position (walls, ceiling, floors etc) complete all as specified and directed by Engineer-in-Charge.
S&F mild steel water tubing 15mm bore medium grade galvanized, ISI marked with all fittings and fixed to walls ceilings, laid in floors, concealed in wall complete all as specified and directed by Engineer-in-Charge.
,---ditto--- all as per serial item No 44, here-in-before but 20mm bore complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel water tubing 25mm bore including fittings, fixed in walls or embedded in walls/cement concrete including demolition of concrete etc complete all as specified and directed by Engineer-in-Charge.
S&F mild steel water tubing 25mm bore medium grade galvanized, ISI marked with all fittings and fixed to walls ceilings, laid in floors, concealed in wall complete all as specified and directed by Engineer-in-Charge.
S&F in repairs vitreous china white squatting pan, water closet size 580mm with foot rest any pattern and with P or S trap or back inlet and connected to flushing pipe including provision of lime concrete bedding and making good the floor with existing specifications complete all as specified and directed by Engineer-in-Charge
M&L PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate with admixture WPC and sunken portion shall be made to slope 1:20 toward outlet, in manholes/mud stops, rounded or chamfered on edges complete all as specified and directed by Engineer-in-Charge.
M&L sides of sunken portion shall be rendering 10mm thick in cement mortar (1:3) on Sunken portion mixed with water proofing compound @ 3% by weight of cement (WPC shall be measured separately) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 10 liter cpacity PVC valve less, symphonic action type, flushing cistern, low level,white,with inlet, ball valve, float and handle, brackets including two coats of synthetic enamel paint over a coat of red oxide primer on brackets and PVC 32mm bore flush pipe upto WC etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs bib taps (ISI Marked) cast copper alloy with crutch or butter fly handle screed down for iron pipe or for brass ferrule of 15mm bore complete all as specified and directed by Engineer-in-Charge. Note : Min weight of tap should be as per SSR
S&F in repairs15mm stop cock cast copper alloy screwed down high pressure fixed to pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair Vitreous China Wash basin, white, flat back, size 550 X 400mm excluding piller taps,but including brackets and waste pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15 mm pillar tap cast copper alloy CP with capstan head screw down high pressure with or without lettered ‘Hot or Cold” with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repairs brass chromium plated shower rose fancy type 75mm dia with swivel joints complete incl 150 mm long brass chromium plated arms fixed to steel pipe or union complete all as specified and directed by Engineer-in-Charge.
S&F in repairs15 mm dia PVC connection 45 cm long with brass nuts and washers on both sides screwed to iron pipe or brass ferrule complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 75 mm bore pipe cast iron soil and waste and vent pipes in any length with or without ears, with cement joints laid in trenches or in floors including taking down, clamp etc complete all as specified and directed by Engineer-in-Charge.
M&L cast iron floor trap in repair as per IS 3980 - 1980 dia of out let 75 mm with grating jointing in waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed by Engineer-in-Charge.
Dismantling water tanks of any type description of capacity 500 liters but n exc 1000 liter and removing to store complete all as specified and directed by Engineer-in-Charge.
S & F Rotational moulded polyethylene water storage tanks, white, tripple layer, ISI marked, capacity 1000 liters (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed by Engineer-in-Charge.
S&F in repair 20 mm bore ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick PCC 1:3:6 type C-1 using 20mm graded mechanically crushed stone aggregated as in plinth/path with necessary frame work as required and finishing the surfaces even and fair without using extra cemen complete all as specified and directed by Engineer-in-Charge.
Taking down rain water pipes (any size or pattren) incl all fittings complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) Rain water pipes 110 mm bore fixed to wall or laid in floor etc with stack clamps complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC (SWR) bend of 110 mm bore complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work built in cement mortar including all quoins, arches pillars etc complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with fly ash sub-class “B” bricks straight or curved in plan exceeding 6mtr mean radius with old size bricks built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 100mm bore pipe cast iron soil and waste and vent pipes in any length with or without ears, with cement joints laid in trenches or in floors including taking down, clamp etc complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking up drain pipes (SGSW, AC or RCC) of internal dia 150mm, set in cement mortar complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
M &L Concrete bed to drain pipes 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 type D2 using 40mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge.
S & F Reinforced concrete pipes, class NP2, laid and jointed complete with collars, 150mm bore, laid in trenches and jointed etc complete all as specified and directed by Engineer-in-Charge.
Cutting into existing manholes for connecting new drains pipe of 150mm dia, making good to pipe and rendering, cutting out existing benching for and forming branch chennel 1/2 round or 3/4 section in cement concrete 1:2:4 type B1 smooth finish reforming benching as required for 150mm dia pipe complete all as specified and directed by Engineer-in-Charge..
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed by Engineer-in-Charge. .
S & F cast iron branch, single 100mm dia with/without ears providing lead joints in lieu of cement joints for pipes embedded in masonry or concrete complete all as specified and directed by Engineer-in-Charge.
S & F cast iron branch, single 75mm dia with/without ears providing lead joints in lieu of cement joints for pipes embedded in masonry or concretecomplete all as specified and directed by Engineer-in-Charge.
Demolition of roof kerb of PCC any description not other wise specifically provided complete all as specified and directed by Engineer-in-Charge.
Raking out joints/ pointing to roofs, to brick work or brick tiles, laid flat, in floors, surface channels, roofs in CM , etc complete all as specified and directed by Engineer-in-Charge..
Dismantling Bricks tilles or terracing tiles, single layer on roofs complete all as specified and directed by Engineer-in-Charge.
Demolition of mud pushka in roofs, any thickness ,including plastering and leeping (whether full thickness removed or only a part thereof ) complete all as specified and directed by Engineer-in-Charge..
M&L for Roof treatment to RCC roof as follows:- (a) Cleaning the roof surfaces thoroughly using wire brusehes to remove sharp projections, cleaning joints, washing, drying and removing all dirt/dust to receive concrete padding/plaster etc. (b) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:4) with WPC, finished even and smooth without using extra cement. (c) Providing one coat of approved bituminous primer @100 gms per sqm, over dried plastered surface. (d) Laying 3 mm thick APP membrane,(mineral finish) reinforced with non woven polyster fabric, by torch application. The overlapping while torching shall be 75 mm on longitudinal direction and 100 mm on the transverse direction complete all as specified and directed by E-in-Charge.Make : STP Dr Fixit/Pidilite, Texsa India Ltd/Tikitar Dansona/Bengal Bitumen Notes : (i) All joints and change in directions should be covered wih cement mortar (1:3) mixed with SBR latex @ 200 ml/bag of cement/as per site reqmt and cured well before laying membrane by torching. (ii) All angles and abuttments should be sealed well with extra care to ensure full bondage. (iii) Water proofing treatment shall be got carried out by approved authorised applicator of manufacturer only. The name of firm shall be got approved from GE before carrying out the wk. (iv) The independent testing of membrane for technical parameters given in particular specifications shall be carried out from Govt approved labs having fascilities for testing of membrane. (v) The guarnatee of treatment shall be for min 10 yrs reckoned from date of completion of whole wk.
M & L 50mm thick PCC 1:2:4 type B-0 using 12.5mm graded mechanically crushed stone aggregate as roof surfaces with in slope 1:40 complete all as specified and directed by Engineer-in-Charge..
M&L PCC (1:2:4) type B1 using 20mm graded stone aggregate as in benching, roof kerbs, gola or mud stops, rounded or chamfered on edges complete all as specified and directed by Engineer-in-Charge..
Suply only integral water proofing compound complete all as specified and directed by Engineer-in-Charge.
Returning filling in, spreading levelling, watering and Well ramming complete all as specified and directed by Engineer-in-Charge. .
Removal of excavated soil to a distance n.exc. 50m above the starting point complete all as specified and directed by Engineer-in-Charge.
S&F in repair sink with drainage board made of stainless steel 0.80mm thick for kitchen with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or with & including fixing cantilever brackets and connecting union to pipe, overall size 915 x 460 mm bowl size 410 x 330 x160 mm including waste pipe of polythelene of low or high density or PVC 32mm dia & waste fitting brass chromium plated for 32mm bore with long screwed shanks and fly nuts including making holes in stone walls for brackets and fixed in CM 1:3 or PCC 1:2:4 type B0 complete all as specified and directed by Engineer-in-charge.
S & F In repair stainless steel kitchen plate rack made out with 1mm thick sheet of size 24''x 24'' x10'' including taking down existing wooden/steel plate rack complete all as specified and directed by Engineer in Charge. Make: Priyag cat no. -310.
S&F for drapery rods coloured ,standard qulity ,powered coated not less than 25mm dia with heads at both ends and middle supported ringsetc complete all as specified and directe by engineer in charge.
S&F Mild steel cupboard shutter with frame, Godrej Pattern, made out of 22 gauge mild steel sheet including chromium plated MS handle with proper locking arrangement (brass mortice lock, vertical type, size 65mm, 4 Levers with escutcheon plates & two keys) with & including two coats of spray painting with synthetic enamel paint of approved tint over a coat of red oxide primer including fixing with 6 Nos 12mm dia bolt 150 mm long grouted in brick wall/concrete including making good the disturbed surfaces as original complete all as specified and as directed by Engineer-in-Charge
M&LPreparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L for two coats of cement base paint on wall over a coat of primer including preparation of the new plastered wall surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new wooden surfaces of any description not otherwise described exc 10 cm width or girth and applying two coats of synthetic enamels paints over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparing old painted wood or wood base surface of any description over 10cm width or girth and apply one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surface of any description not otherwise described exc 10cm width or girth and applying two coats of synthetic enamels paints over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparing old painted steel and iron surfaces of any description over 10cm width and girth and apply one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L complete removal of existing treatment and applying two coats of cement base paint paint on walls over a coat of primer (Priming plastered and other surfaces with alkaliresistant priming paint) complete all as specified and directed by Engineer-in-charge.
M&L complete removal of existing treatment and applying two coats of Oil bound distemper on walls over a coat of distempering primer complete all as specified and directed by Engineer-in-charge.
M & L complete removal of existing treatment, applying 3mm thick wall care putty on wall complete all as specified and directed by Engineer-in-charge.
M & L complete removal of existing treatment, applying 3mm thick wall care putty on RCC ceiling surfaces complete all as specified and directed by Engineer-in-charge.
M&L preparation of old surfaces (plastered or unplastered) of walls including cornices, pilasters etc including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of colour washing complete all as specified and directed by Engineer-in-charge.
M&L preparation of old surfaces (plastered or unplastered) of ceiling including cornices, plasters etc including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of colour wash complete all as specified and directed by Engineer-in-charge.
Material and labour preparation of new steel surfaces (already applied with coat of primer) of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint on existing primer complete all as specified and directed by Engineer-in-Charge.
E/M Portion Taking down carefully copper/aluminium point wiring (light, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulators, sockets etc to be measured separately), and making good disturbed surfaces of walls, floors etc to match with existing surfaces.
M&L for concealed Point wiring with two single core PVC insulate FRLS, unsheathed multistranded copper conductor cable of size 1.5 sq.mm (FRLS) drawn in and including electrical grade PVC conduit 20 mm dia concealed on wall/ceiling/floor including PVC insulated unsheathed earth wire with multi stranded copper conductor of size 1.5 sq.mm(FRLS) including MS shunk sheet metal box with 3 mm thick hylam sheet top cover of required size for mounting switches, sockets etc for One Light/ fan point controlled by one, one way switch complete all as specified and directed by Engr-in-charge. Note - quoted rate shall include making good to the disturbed surfaces including plastering and painting to match with the existing colour.
,---ditto---all as per serial item No 107 above but for One 3 pin switch socket outlet, 5 Amp on the same board with other switches complete all as specified and directed by Engr-in-charge.
,---ditto---all as per serial item No 107 above but for One 3 pin 5 amps switch socket outlet point on independent board complete all as specified and directed by Engr-in-charge.
,---ditto---all as per serial item No 107 above but for One bell push flush type 6 Amp complete all as specified and directed by Engr-in-charge.
,---ditto---all as per serial item No 107 above but for One switch piano flush button single pole two way 6 Amps complete all as specified and directed by Engr-in-charge.
,---ditto--- All as per serial item No 107 above but wiring with 4 Sqmm multistranded copper wire FRLS and earth wire with copper conductor of size 4 Sqmm for 15 Amps power point complete all as specified and directed by Engineer-in-Charge.
Supply and fix fan regulator electronic solid state with steps suitable for 100/120watt for ceiling fan working on 230 volt AC complete all as specified and directed by Engineer-in-Charge.
Supply and fix Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and directed by Engineer-in-Charge.
Supply & fix switch bell push AC 230 volt single pole complete all as specified and directed by Engineer-in-Charge.
Supply and fix lamp holder insulated body with back plate for angle/batten fitting with LED lamp of 09 watt complete all as specified and directed by Engineer-in-Charge.
Supply and fix piano switch flush button single pole one way 6 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and fix socket outlet 2 in 1, 3 pin 5 amp and 15 amp flush type 240 volts AC complete all as specified and directed by Engineer-in-Charge.
Supply and fix piano switch 15 amp flush type 240 volts AC complete all as specified and directed by Engineer-in-Charge.
S & F LED light fitting 1 x 20 W, 230 V integral sleek polycarbonate LED Channel with white acrylic cover incl making connection complete all as specified and directed by Engineer-in-Charge.
Supply and fix ceiling rose surface bakelite two to three terminals/plate 5 amps complete all as specified and directed by Engineer-in-Charge.
Supply and fix factory made, sheet distribution boards TP & N 4 Ways, double door, protection class IP-42 suitable for mounting MCB/MCCB, confirm to IS-13032, IS-8623, BS-5484 with min 200 Amps, copper bus bar, working on 240 V AC of the under mentioned type of make :- Legrand/ ABB/ Seimens
,---ditto-- all as per serial item No 122 above but SP & N 8 ways complete all as specified and directed by Engineer-in-Charge.
S&F in DBs (catered above) MCBs TP & N 63 Amps, 9 KA confirm to IS-8828 : 1996, IEC- 898 : 1995 rupturing capacity of the undermentioned type and rating of make :- Legrand/ ABB/ Seimens
,---ditto-- all as per serial item No 124 above but SP & N 63 amps complete all as specified and directed by Engineer-in-Charge.
,---ditto-- all as per serial item No 123 above but SP & N 40 amps complete all as specified and directed by Engineer-in-Charge.
,---ditto-- all as per serial item No 124 above but SP 6-32 amps complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Sub Main Wiring including taking down with two run single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in PVC conduit & accessories Suitable size with and including 4 Sqmm copper green colour earth wire all as specified and directed by Engineer-in-Charge. NOTE-two run of 6 sq.mm & One run of 4 sq.mm & One run of PVC conduit with accessories shall be measured as One length.
Supply, laying and testing of Cable XLPE insulated screened PVC bedded, galvanised steel strip armoured, electric power cable with stranded aluminium conductor 1100 Volt grade of size 25 Sqmm 4 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing of Cable XLPE insulated screened PVC bedded, galvanised steel strip armoured, electric power cable with stranded aluminium conductor 1100 Volt grade of size 10 Sqmm 2 core complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Integral LED street light luminaire white light comprising of epoxy powder coated housing, enclosed with glass cover in frame 25 W not less than 100 lumensper watt AC 230 Volt supply (white Glass suitable for 40/50 mm OD entry for direct mounting on pipe bracket with all electrical accessories wired up to the terminal block suitable for mounted on bracket / poles / walls complete all as specified and directed by the Engr-in-Charge. Make : Bajaj /Hevells/Philips.
M&L for Earthing strip with galvanised steel earth plate electrode 600mmx600mmx6 mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level connected to GI strip 32x6 mm dia by means of bolts, nuts, check nuts and washers complete including earthing pit, Chemical compound, Earthing lead 32 x 6 mm dia up to 7.5 m, 20 mm dia medium grade GI watering pipe, G.I. protection pipe 40mm dia earth pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggragate RCC pit cover including earth work complete all as shown electrical plate No-5 of SSR-2009 (Part-I) NOTE:- The unit rate shall include for excavation & earth work in any type of soil/strata, PCC 1:2:4 type B-I for pit & RCC 1:2:4 type B-I for cover with 8mm dia CTD Bar @150mm C/C both way, funnel with watering pipe 20 mm dia medium grade, 15mm dia light grade GI pipe up to 7.5 mtr long, wiremesh complete all as specified and directed.
Supply and fix fresh air fan 225/250 mm sweep 240 volt 50 Hz plastic body complete with louvers complete all as specified and directed by Engineer-in-Charge.
Taking down exhaust fan,dismantling, repairing complete with changing of bearing & bushed, lubricating and repainting, fixing back in position and reconnecting with 1.5 Sqmm 3.0 core wirecomplete all as specified.
M&L brick protection with sub class'B' brick laid flat across the cable complete all as specified and directed by Engineer-in-Charge.
M & L for sand cushioning with locally available sand to under ground cable below & around the cable gently punning after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
M&L for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in foundation bedding for hardstanding etc. complete all as specified and as directed by Engr-in-Charge.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
M/s Karan Builders
ISHAAN CONSTRUCTIONS
KHANNA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .