Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹39.3 L+₹7.4 L (23.0%)Rejected-Finance | L2 | Rejected-Finance Being other than Lowest bidder | |
| 3 | L3₹40.1 L+₹8.1 L (25.5%)Rejected-Finance DOOR NO 43 2 BESIDES VIZAG DEFENCE ACADEMY 104 AREA KAPPARADA VISAKHAPATNAM 530013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | L3 | Rejected-Finance Being other than Lowest bidder | |
| 4 | L4₹40.5 L+₹8.5 L (26.6%)Rejected-Finance | L4 | Rejected-Finance Being other than Lowest bidder | |
| 5 | L5₹41.6 L+₹9.6 L (30.1%)Rejected-Finance | L5 | Rejected-Finance Being other than Lowest bidder |
| Sl No | Description | Qty | Unit | sandhya enterprises L1 | MS ENTERPRISES L5 | Mavee Syndicate L3 | VS ENTERPRISES L4 | M Shyam Sunder L6 | THE DECAN ENGINEERING AND REFRIGERATION COMPANY L7 | Srinivash Engineers L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down and dismantling old unserviceable damaged, broken / rusted strips including connected items from buildings walls and roofs complete all as directed. | 300 | RM | 8 ₹2,400 | 13 ₹3,900 | 10 ₹3,000 | 8 ₹2,400 | 9 ₹2,700 | 10 ₹3,000 | 5 ₹1,500 Lowest |
| 2.00 | S&F in repairs, aluminium strip 25 x 3.15mm with saddles and fixing screws as roof / down conductors on insulators or fixed in GI pipe complete all as specified and as directed. | 300 | RM | 100 ₹30,000 | 93 ₹27,900 Lowest | 129 ₹38,700 | 112 ₹33,600 | 108 ₹32,400 | 100 ₹30,000 | 122 ₹36,600 |
| 3.00 | S&F in repairs, epoxy insulator with one GI stud bolt with nut and washer with necessary drilling for bolt hole for holding or fixing roof / down conductor of lightning complete all as specified and directed | 600 | Each | 30 ₹18,000 | 23 ₹13,800 | 10 ₹6,000 | 35 ₹21,000 | 27 ₹16,200 | 20 ₹12,000 | 5 ₹3,000 Lowest |
| 4.00 | S&F in repairs, 20mm dia GI light grade pipe with suitable clamps for fixing of air termination rod and earth strip on roof complete all as specified and as directed. | 20 | RM | 125 ₹2,500 | 123 ₹2,460 | 155 ₹3,100 | 120 ₹2,400 | 108 ₹2,160 | 75 ₹1,500 Lowest | 144 ₹2,880 |
| 5.00 | S&F in repairs, air termination single pointed aluminium rod 12mm dia and 300mm long with fixing arrangement complete all as specified and as directed | 20 | Each | 260 ₹5,200 | 393 ₹7,860 | 550 ₹11,000 | 220 ₹4,400 Lowest | 270 ₹5,400 | 900 ₹18,000 | 490 ₹9,800 |
| 6.00 | S&F in repairs, test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm, drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screws including taking down of complete all as specified and directed. | 10 | Each | 770 ₹7,700 | 263 ₹2,630 Lowest | 800 ₹8,000 | 500 ₹5,000 | 540 ₹5,400 | 350 ₹3,500 | 650 ₹6,500 |
| 7.00 | S&F in repairs, Earth continuity conductor with 20x3mm copper strip fixed to wall on batten or recess or chases with necessary porcelain insulators or buried in ground or drawn in conduit/pipe/wall or fixed to poles or any other indicated situation for loop earthing etc., complete all as specified and as directed. | 100 | RM | 420 ₹42,000 | 793 ₹79,300 | 600 ₹60,000 | 340 ₹34,000 Lowest | 387 ₹38,700 | 440 ₹44,000 | 880 ₹88,000 |
| 8.00 | S&F in repairs, Earth continuity conductor with 25x4 GI strip fixed to wall on batten or recess or chases with necessary porcelain insulators or buried in ground or drawn in conduit/pipe/wall or fixed to poles or any other indicated situation for loop earthing etc., complete all as specified and as directed. | 100 | RM | 160 ₹16,000 | 103 ₹10,300 | 100 ₹10,000 Lowest | 144 ₹14,400 | 126 ₹12,600 | 100 ₹10,000 Lowest | 130 ₹13,000 |
| 9.00 | S&F in repairs, 40mm dia GI pipe light grade fixed to walls or laid in trenches etc., for protection of earth strip including sealing ends with hessian cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed on walls complete all as specified and directed. | 60 | RM | 300 ₹18,000 | 133 ₹7,980 Lowest | 300 ₹18,000 | 300 ₹18,000 | 225 ₹13,500 | 250 ₹15,000 | 300 ₹18,000 |
| 10.00 | Cutting of existing bituminous/PCC road or flooring/ plinth protection, for laying of GI pipe in road intersection for passing of LT XLPE cable including excavation in any type of soil, returning and filling in and making good top 30cm of the trench by providing PCC 1:2:4 type B1 using 20mm graded stone aggregate to flush with existing road surface complete all as directed. | 60 | RM | 300 ₹18,000 | 313 ₹18,780 | 300 ₹18,000 | 360 ₹21,600 | 270 ₹16,200 Lowest | 700 ₹42,000 | 300 ₹18,000 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
7 Apr 2025, 6:00 pmClosed
GE (UTILITY) SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
MISC REPAIR / MAINTENANCE OF EARTHING INFRA, AREA LIGHTING CENTRAL AMENITIES IMPROVING OF LIGHTING AT CERTAIN LOCATIONS UNDER AGE E/M I AND REPAIR / REPLACEMENT OF WATER SUPPLY DISTRIBUTION SYSTEM, REPLACEMENT OF CONTROL VALVE, AND CONNECTED ITEMS AT
2025_MES_700701_1
GE (U)/SEC/TOKEN 47 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹99,000
Yes
6 Oct 2025
10 Mar 2025
14 Apr 2025
10 Mar 2025
7 Apr 2025
24 Mar 2025
Amount
Taking down and dismantling old unserviceable damaged, broken / rusted strips including connected items from buildings walls and roofs complete all as directed.
S&F in repairs, aluminium strip 25 x 3.15mm with saddles and fixing screws as roof / down conductors on insulators or fixed in GI pipe complete all as specified and as directed.
S&F in repairs, epoxy insulator with one GI stud bolt with nut and washer with necessary drilling for bolt hole for holding or fixing roof / down conductor of lightning complete all as specified and directed
S&F in repairs, 20mm dia GI light grade pipe with suitable clamps for fixing of air termination rod and earth strip on roof complete all as specified and as directed.
S&F in repairs, air termination single pointed aluminium rod 12mm dia and 300mm long with fixing arrangement complete all as specified and as directed
S&F in repairs, test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm, drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screws including taking down of complete all as specified and directed.
S&F in repairs, Earth continuity conductor with 20x3mm copper strip fixed to wall on batten or recess or chases with necessary porcelain insulators or buried in ground or drawn in conduit/pipe/wall or fixed to poles or any other indicated situation for loop earthing etc., complete all as specified and as directed.
S&F in repairs, Earth continuity conductor with 25x4 GI strip fixed to wall on batten or recess or chases with necessary porcelain insulators or buried in ground or drawn in conduit/pipe/wall or fixed to poles or any other indicated situation for loop earthing etc., complete all as specified and as directed.
S&F in repairs, 40mm dia GI pipe light grade fixed to walls or laid in trenches etc., for protection of earth strip including sealing ends with hessian cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed on walls complete all as specified and directed.
Cutting of existing bituminous/PCC road or flooring/ plinth protection, for laying of GI pipe in road intersection for passing of LT XLPE cable including excavation in any type of soil, returning and filling in and making good top 30cm of the trench by providing PCC 1:2:4 type B1 using 20mm graded stone aggregate to flush with existing road surface complete all as directed.
M&L in repairs, Earthing complete with copper earth plate electrode of size 600 x 600 x 3.15mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5m below normal ground level connected to copper strip 20x3mm as earth lead by means of bolts, nuts, washers and check nuts made out of galvanized iron or steel all as shown on Electrical Plate No. 3 of SSR Part-I including testing on completion complete all as specified and directed by Engr-in-charge.
Notes a) The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, 50mm thick RCC 1:2:4 type B-1 using 20mm graded stone aggregate cover slab reinforced with 6 Nos of 8mm dia TMT bars both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe medium grade 25mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub-heading earthing, specified on Sl Page No. 422 of SSR Part-II. b) Copper earth strip beyond 7.5m will be measured and paid separately.
M&L in repairs, Earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5m below normal ground level connected to GI strip 25x4mm as earth lead by means of bolts, nuts, washers and check nuts made out of galvanized iron or steel all as shown on Electrical Plate No. 3 of SSR Part-I including testing on completion complete all as specified and directed by Eng-in-charge.
Notes a) The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, 50mm thick RCC 1:2:4 type B-1 using 20mm graded stone aggregate cover slab reinforced with 6 Nos of 8mm dia TMT bars both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe medium grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub-heading earthing, specified on Sl Page No. 422 of SSR Part-II. b) GI earth Strip beyond 7.5m will be measured and paid separately.
S&F in repairs, LED Aviation obstruction light, yellow painted, die-cast aluminium housing with red polycarbonate dome for better illumination, IP 65, surge and short circuit protection, wide operating voltage and suitable accessories fixed at any height complete all as specified and directed. Make: BAJAJ CAT No BGAV 302 LED or equivalent in PHILLIPS/CG/HAVELLS/WIPRO as approved by GE
S&F in repairs, 90W LED street light with high quality integrated LED Luminaire with a system lumen of 11000 and system wattage 90w with an efficiency 120 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be separate optical and control gear compartment & bottom opening for easy maintenance and of high quality pressure die cast aluminium with PF > 0.95 and THD < 10% & Operating temperature: -10°C to + 50°C. Input voltage of 100-300V. Lifetime of 50K hours @L70. Product should be suitable for continuous operation (16-18 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 07. The luminaire should have Integrated peanut optics to provide a high quality glare free lighting system. The Driver should be potted & should be a BIS approved driver and not a printed circuit board without casing, mounted inside the luminaire with Phase to Phase protection Over Voltage protection, Surge Voltage protection up to 10 kV & other safety test as per IS 15885 Part-2/Sec 13 . The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. BIS approval for Both Driver and the luminaire needs to be submitted for records before claiming RAR complete all as specified and as directed by Eng-in-charge. MAKE : Havells: ENDURASUNDOWNSL90WLED757PASYBOTGHO Or Equivalent in Philips or Wipro.
S&F in repairs, 60W LED street light with high quality integrated LED Luminaire with a system lumen of 7200 and system wattage 60w with an efficiency 120lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be separate optical and control gear compartment & bottom opening for easy maintenance and of high quality pressure die cast aluminium with PF > 0.95 and THD < 10% & Operating temperature: -10°C to + 50°C. Input voltage of 100-300V. Lifetime of 50K hours @L70. Product should be suitable for continuous operation (16-18 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 07. The luminaire should have Integrated peanut optics to provide a high quality glare free lighting system. The Driver should be potted & should be a BIS approved driver and not a printed circuit board without casing, mounted inside the luminaire with Phase to Phase protection Over Voltage protection, Surge Voltage protection up to 10 kV & other safety test as per IS 15885 Part-2/Sec 13 . The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. BIS approval for Both Driver and the luminaire needs to be submitted for records before claiming RAR complete all as specified and as directed by Eng-in-charge. MAKE : Havells: ENDURASUNDOWNSL60WLED765PASYBOTG Or Equivalent in Philips or Wipro.
S&F in repairs, LED floodlight 150W system lumens 18000lm, luminaire with pressure die cast aluminium (ADC12) housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT > 5700K, IP 66 optical and electrical compartment i.e. Built-in potted driver & impact resistance of complete luminaire > IK07. Power Factor >0.95 with mains, Surge Protection- Min 10KV along with Over voltage/ Overload, short circuit/ miss-wiring protection with other safety test as per IS 15885 Part-2/Sec 13. Universal Voltage driver to operate wide voltage range from 100 V to 270V, 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB . LED Light fixture with 150W System Power consumption. LED Efficiency> 120m/w, nominal CRI >70. Luminaire manufacturer should have in- house facility accredited by NABL certified agency & Design & Development facility certified by ISO 9001:2008. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. BIS approval for Both Driver and the luminaire needs to be submitted for records before claiming RAR complete all as specified and as directed by Eng-in-charge. MAKE : Havells: JETALEGANZAFLS150WLED730P60DTOTG Or Equivalent in Philips or Wipro.
S&F in repairs, LED floodlight 100W system lumens output 12000lm, luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT > 5700K, IP 66 optical and electrical compartment & impact resistance of complete luminaire > IK07. Power Factor >0.95 with mains, Surge Protection- Min 10KV along with Over voltage/ Overload, short circuit/ miss-wiring protection with other safety test as per IS 15885 Part-2/Sec 13. Universal Voltage driver to operate wide voltage range from 100 V to 270V, 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB . LED Light fixture with 100W System Power consumption. LED Efficiency> 120m/w, nominal CRI >70. Luminaire manufacturer should have in- house facility accredited by NABL certified agency & Design & Development facility certified by ISO 9001:2008. BIS approval for Both Driver and the luminaire needs to be submitted for records. MAKE : Havells: JETALEGANZAFLS150WLED730P60DTOTG Equivalent in Philips or Wipro.
S&F in repairs, 25W Decorative Postop, Aesthetically designed LED post Top with aluminium enclosure and die casted heat sink exhibits classic look with symmetrical light distribution and excellent heat dissipation for long life. Family of post top, lantern designed to complement the geometry of the area Die-cast aluminium spigot for mounting LED driver and spun aluminium canopy which is painted white inside. Opening separate driver compartment with IP65 protection and impact resistance of IK07.Operating temperature: -10°C to + 50°C, Operating voltage range: 140-270V, Average life L70B50: 50000 hours, High efficiency long life LED module with SMD , LED package mounted on MCPCB. Lumen, efficacy of LED >140 lm/W, Powered by built-in potted LED driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 415V AC), Over, Voltage protection, Surge Voltage protection up to, 4 kv with SPD & other safety test as per IS 15885 Part-2/Sec 13. THD< 10%, PF>.95, Current= 0.120A, CCT 5700K. Make: Havells Cat Ref: RUBYMINIPT25WLED757PSYMTOPC Or Equivalent / Philips Wipro.
S&F in repairs, LED floodlight 50W system lumens output 4850lm, luminaire with Pure polyester powder coated die-cast aluminium housing in grey finish with aesthetically designed PC reflector for maximum light output. PC lens used for symmetric distribution. Tempered protective toughened glass, thermal shock and impact resistant to the housing with aluminium frame, delivering superior light output Rated life Burning Hrs 35000 hr @ Lumen Maintenance of 70%, CCT > 5700K, IP 66 optical and electrical compartment & impact resistance of complete luminaire > IK07. Power Factor >0.95 with mains, Surge Protection- Min 10KV along with Over voltage/ Overload, short circuit/ miss-wiring protection with other safety test as per IS 15885 Part-2/Sec 13.LED Light fixture with 50W System Power consumption. LED Efficiency> 100m/w, nominal CRI >70. Luminaire manufacturer should have in- house facility accredited by NABL certified agency & Design & Development facility certified by ISO 9001:2008. BIS approval for Both Driver and the luminaire needs to be submitted for records. MAKE : Havells: JETAADORNNXTFLS50WLED757P60DTOTG Or Equivalent / Philips Wipro.
S&F in repairs, connecting and testing decorative LED Bollard light with opal diffuser & aluminium reflector of 8/9/11watt 3 Feet LED including nut, bolts, washers, clamps etc complete all as specified and directed by Engr -in-charge. Make: Havells Cat Part No.BAMBOOBL8WLED857SSYMTOPCM or equivalent in Crompton/Philips/Wipro.
S&F in repair, bracket suitable for street light fitting made out of 40mm dia GI tubing light grade 1.5m long bent to shape, fixed with necessary nuts bolts and clamps of size 32X6mm complete all as Specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor cable of size 3 core 4 sq mm served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sq mm 3 core in service connections complete all as specified and directed.
Supply and fix in repair, electrically operated digital time switch DIN type daily/weekly programmable every 1 minute, with backup of 6 years, 28 memory locations, current capacity 16A, weekly program, with 1 changeover (CO), total 28 programs for street light suitable to operate on 230Volts complete all as specified. Make: Indoasian CAT No TDA43110 or equivalent in Legrand/Siemens/Schneider
Supply & fix in repair, 3 pole contactor AC3 rating of 40 Amps complete all as specified. Make: C&S equivalent in Legrand / Siemens / ABB / Schneider
Supply and fix in repairs, hot pressed moulded SMC junction box of internal size 250x200x100mm, IP 55 with integrated membranes/ metric knocouts for cable entry with terminals and arrangements for incoming and outgoing 3 phase 4 wire system, R,Y,B & N stud and control for incoming and outgoing cables , D clamps made of flat iron 25x3 mm suitable to pole of any size including bolts nuts and washers etc, complete all as specified and as directed. Note: The unit rate quoted shall be deemed to include for incoming & outgoing cables glands & lugs of size up to 25Sqmm 4 core. Make: Sintex or equivalent in Hensal as approved by GE
M&L in repairs, Cleaning the steel tubular poles of 9/11 metres long of any description thoroughly with necessary cleaning agent including scrapping up of old corroded paint dirt/dust/rust carefully and applying two coats of aluminium paint over a coat of red oxide primer and writing of MES No on pole with emulsion black paint complete all as specified and directed.
M&L in repairs, Stickering of any type of street light pole with A1 graded radium strip of 100mm width three colour red, Yellow and green around the pole with 100mm gap in each strip at a distance of 1.1 metre high from the ground level complete including white wash to the coping and marking of pole numbers with emulsion black paint complete all as directed by Engineer-in-Charge.
S&F in repairs universal LED driver suitable for 45 to 90W street light fittings complete all as specified and directed..
S&F in repairs, Aesthetically designed decorative hot dipped galvanised mild steel step 3M pole with grey powder finish, Compatible for post top range. Window - Plasma cut & duly chamfered opening window of 300x110 mm for terminal connections & mounting accessories Window cover is fitted with allen screws to the pole complete all as specified and as directed. Make Havells cat no - DECO POLE 3M TOP 76Ø or equivalent in Bajaj /Philips.
S&F in repairs, 45W Circular LED post-top offering excellent uniform illumination and aesthetics in one go Made up of Pressure Die Cast aluminium body and opal PC cover., IP 66 and IK 07 rating complete all as specified and as directed. Make Havells cat no RINKPT45WLED757PSYMTOPC or equivalent in Bajaj / Philips
Repair/rectification of leakages to water supply distribution lines 15 mm bore to 25 mm bore GI/PPR tubing with provision of necessary excavation, cutting of hard standing, returning and filling in as required, tightening of loose joints of union, elbow, sockets etc, threading if required including replacement of GI unions/sockets/nipples as required at site complete all as specified and directed.
All as per item No 31.00 above but for GI tubing 40 mm bore to 50 mm bore
All as per item No 31.00 here-in-before but for GI tubing 80 mm bore to 100 mm bore.
Attending routine complaints of external water supply including rectification of minor defects by taking down of existing GI/PPR tubing up to 25 mm bore, cutting/threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of jumper valve/ packing sheet of gate valve and including replacement of GI unions/sockets/nipples etc as required at site complete all as specified and directed.
All as per item No 34.00 above but for GI tubing 40 mm bore to 50 mm bore.
Attending complaints of BLOCKAGE OF WATER PIPE LINES / NO WATER SUPPLY AT ANY kind of ACCOMODATION ( MARRIED / OTM/ single / multi story building), IDENTIFY THE FAULTS including rectification by taking down of existing GI/PPR tubing up to 80 mm bore, cutting/threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of valve/ packing sheet of gate valve and including replacement of GI unions/sockets/nipples etc as required at site TO RESTORE WATER SUPPLY complete all as specified and directed.
Notes for Sl item No 31 to 36 :- (a) The contractor will be allotted complaints at MES complaint cell on requirement basis on all working days including Sundays and holidays and sufficient tradesman / resources will be deployed by him/her for completion of day to day complaints within 12 hours from the time of reporting. Any delay beyond above mentioned time limit without intimation of genuine cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log book of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consultation with JE E&M/Engr-in-Charge. (c) The contractor will make suitable arrangement for emergency complaints and will notify authorised representative/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard.
(d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare/fittings utilized as per inventory format given by AGE E/M, Secunderabad and the same shall be submitted to E/M No II store yard on requirement basis. (g) The stationery required for the job work such as complaint slip books, gate pass book, job card and T&P shall be arranged and maintained by the contractor. (h) The cost of excavation / earth work above 1 CUM measured and paid separately under relevant items. j) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution. (k) Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items.
Rectification of leakages in pumping /delivery lines(CI/DI/PPR/MS) of size 80 mm to 100 mm at Military area / Military Roads /civil Roads /PWD Roads /Cantt board roads by taking necessary permission from respective authorities by excavating PCC/RCC/pavement/soft & hard soil/rock of any depth by using necessary T&P(Excavator/hammer drill)as per the requirement, De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/ DI specials such as collars, bends/tail pieces, any type of gasket , welding work etc as required to arrest the leakages completely and making joints, filling the trenches , site clearances and PCC at the top portion as required complete all as specified and as directed. Note:-(i)CI specials, lead Joints, D-Joints, Clamp joints, DI/CI Pipe etc shall be measured and paid under respective items of BOQ. (ii) Excavation and PCC will be measured and paid separately under relevant items.(iii) rate of any kind of gasket and Lead joint, necessary barrication for safety of worker etc as required , deemed to be included in the quoted rate.(iii) rate of any kind of gasket and necessary barrication for safety of worker etc as required , deemed to be included in the quoted rate.(iv) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES department if required.(v) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
Rectification of leakages in pumping /delivery lines(MS/CI/DI/PPR) of size 150 mm to 400 mm at Military area / Military Roads /civil Roads /PWD Roads /Cantt board roads by taking necessary permission from respective authorities by excavating PCC/RCC/pavement/soft & hard soil/rock of any depth by using necessary T&P(Excavator/hammer drill)as per the requirement , De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/ DI specials such as collars, bends/tail pieces, any type of gasket , welding work etc as required to arrest the leakages completely and making joints, filling the trenches , site clearances and PCC at the top portion as required complete all as specified and as directed. Note:- (i)CI specials, lead Joints, D-Joints, Clamp joints, DI/CI Pipe etc shall be measured and paid under respective items of BOQ. (ii) Excavation exceeding 2 CUM and PCC will be measured and paid separately under relevant items. (iii) rate of any kind of gasket and necessary barrication for safety of worker etc as required , deemed to be included in the quoted rate. (iv) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES department if required. (v) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
M&L for attending break down of water supply pipe line at Military area / Military Roads /civil Roads /PWD Roads /Cantt board roads and repair s to CI/DI/PPR/MS water mains of size 80 mm to 400 mm bore at a given notice including necessary excavation in mud, in any type of soil , PCC,RCC, hard rock etc by manual or using special T&P such as JCB etc. De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI specials such as collars, bends/tail pieces etc and making joints complete all as specified and as directed including making good of disturbed surfaces. Note:- (i)CI specials, lead Joints, D-Joints, Clamp joints, DI/CI Pipe etc shall be measured and paid under respective items of BOQ. (ii) Excavation and PCC will be measured and paid separately under relevant items. (iii) Rate of any kind of gasket and necessary barrication for safety of worker etc as required, deemed to be included in the quoted rate. (iv) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES department if required. (v) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution (vi) In case of any kind of breakdown contractor should be intimated over Telephone and contractor should attend the complaints with minimum reaction time .
Excavation in trenches not exceeding 1.5 m width and not exc 1.5 m in depth and getting out in hard/dense soil for removing/laying of pipe line complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning the pipes free from scaling for re-fixing or removal complete with all fittings and connections of the following sizes :-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Refixing of old steel tubing and connection in new or old position including cutting threads if required, fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:- Notes (a) Excavation and Earth work shall be measured and paid separately.
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Refixing of old steel tubing and connection in new or old position including, cutting threads if required, fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
Supply and laying in replacement steel water tubing medium grade, galvanised with all fitting, laid in trenches and testing for leakages complete all as specified and directed for the following sizes:- Notes- (a) Excavation and Earth work shall be measured and paid separately.
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Supply and laying in replacement steel water tubing medium grade, galvanised with all fitting, fixed to wall and ceilings or laid in floor and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
Taking up unserviceable/ defective CI/DI/MS/PPR water mains (including all fitting) with spigot/ socketed / flanged ends including disconnecting pipes and fittings in any position complete all as specified and directed for the following sizes:-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
Refixing of old CI/DI/MS Pipe and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
80 mm dia
100 mm dia
150 mm dia
200 mm dia
S&F in replacement ductile iron pressure pipes, class K7, centrifugally cast with spigot and socket ends as per following conforming to IS 8329/2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on-joint (rubber gasket D jointing) in any length including DI specials as required at site confirming to IS 8329/2000 and all jointing materials and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, cutting the existing CI/DI/MS pipe line of any size up to 400 mm dia for inserting branch connections etc complete all as specified and directed for the following sizes:- Notes:- (a) Quoted rates inclusive of Push on Joints / D-Joints as required (b) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES department if required. (c) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
100 mm Dia
150 mm Dia
200 mm Dia
Cutting existing CI pipe line for insertion of new tees, collars for branch connections complete all as specified and directed for the following sizes:- Note: CI /DI specials, Joints and Earth work shall be measured and paid separately under relevant items of this schedule.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
Supply in replacement GI fittings 15 mm bore, medium grade, ISI marked, smooth finished and make embossed on fittings complete all as specified and directed for the following fittings:-
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
All as per item No 52.00 above but for 20 mm bore.
Union
All equal Tee
Reducer Tee 20 x 20 x 15 mm
Socket
Reducer Socket 20 x 15 mm
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Reducer Elbow 20 x 15 mm
Elbow
All as per item No 52.00 above but for 25 mm bore.
Union
All equal Tee
Socket
Reducer Socket 25 x 20 mm
Reducer Socket 25 x 15 mm
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer Elbow 25 x 20 mm
Reducer Elbow 25 x 15 mm
Reducer tee 25mm x 25 mm x 20mm
Reducer tee 25mm x 25 mm x 15mm
All as per item No 52.00 above but for 40 mm bore.
Union
All equal Tee
Socket
Reducer Socket 40mm x 25 mm
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer elbow 40mm x 25mm
Reducer tee 40mm x 40mm x 25mm
Reducer tee 40mm x 40mm x 20mm
Reducer Socket 40mm x 20 mm
Reducer elbow 40mm x 20mm
All as per item No 52.00 above but for 50 mm bore.
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Reducer Socket 50mm x 40mm.
Reducer Socket 50mm x 25mm.
Elbow
Reducer elbow 50mm x 40mm
Reducer elbow 50mm x 25mm
Reducer tee 50mm x 50 mm x 40mm
Reducer tee 50mm x 50 mm x 25mm
Reducer tee 50mm x 50 mm x 20mm
All as per item No 52.00 above but for 80 mm bore.
Union
All equal Tee
Socket
Reducer Socket 80mm x 50mm.
Reducer Socket 80mm x 40mm.
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer elbow 80mm x 50mm
Reducer elbow 80mm x 40mm
Reducer tee 80mm x 80mm x 50mm
Reducer tee 80mm x 80mm x 40mm
Supply and fix in replacement of unserviceable Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and directed for the following sizes:-
15mm dia bore
20mm dia bore
25mm dia bore
40mm dia bore
50mm dia bore
Supply and fix in replacement of unserviceable ball brass valves, high pressure with polythene float and fly nut alongwith socket/reducer of suitable size, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed for the following sizes:-
20mm dia bore
25mm dia bore
M&L for Arresting leakages of sluice valves by replacing Gland packing, gland bush, gland flange, nut bolts, gasket, packing material as required after dismantling in existing position including testing on completion complete all as specified and directed for the following sizes:- Note: Quoted rates inclusive of the materials mentioned above like Gland packing, gland bush, gland flange, nut bolts, gasket, packing material etc as required to arrest the leakages.
80 mm Dia
100 mm Dia
150 mm Dia
S&F in repairs CI / DI specials such as bends (any type, radius or angle) tapers any type (Straight, bend, increase, decrease or double socket etc) tee pieces, single 'Y' branch, double branch cross (all sockets, socket and spigots, collars, cap plugs etc up to 150 mm bore complete all as specified and directed.
All as per item No 61.00 above but for 200 mm bore to 300 mm bore.
Burning out lead joint in position for following sizes of CI/DI pipe, removing old lead complete all as specified and directed :-
80 mm Dia
100 mm Dia
150 mm Dia
M&L in repairs for run lead joint for CI pipe/DI pipe including spun yarn etc for spigot and socket pipes and fittings complete all as specified and directed for the following bore of pipes:-
80 mm Dia
100 mm Dia
150 mm Dia
S&F in repairs CAST IRON OR DUCTILE IRON MECHANICAL COUPLING / MECHANICAL JOINT / D JOINT heavy duty INCLUDING ALL JOINTING MATERIAL , ISI marked, split type with long collar, suitable rubber rings, bolts, nuts and washers etc suitable for MS/CI/DI/GI /PVC pipes of following sizes AS REQUIRED FOR REPAIRING OF ANY KIND OF LEAKAGES COMPLETE all as specified and as directed:- Notes:- (a) Excavation and Earth work shall be measured and paid separately. (b) Quoted rate inclusive of cutting of any kind of pipes and all ITEMS as required for fixing and proper functioning of Joints. (c) Quoted rate is deemed to be inclusive of necessary T&P for cutting the pipe line, Pump sets for De-watering, JCB for Excavation (if required) etc and no extra payment shall be admissible on this account.
80 mm Dia
100 mm Dia
150 mm Dia
Supply and fixing in replacement of DI D/F Gate valve (Soft Sealed) Resilient Seated Soft Sealing gate valves( Sluice valves RAISING TYPE) with body bonnet of ductile cast iron of grade GGG-40/SG- 400/15 or GGG-50/SG-500/7 or equivalent grade as per IS 3896 - Part 2- 1985 and subsequent revisions, Wedge fully rubber lined with EPDM Food grade quality and Seals of NBR and the valve should be vacuum tight and 100 % leak proof with face to face dimension as per BS 5163-89/IS 14846-2000/DIN 3202 F 4. and Valves should be electrostatic powder coating both inside and outside pocket less body passage class PN 1.6 including all jointing materials (Gasket, Nut bolts etc) connecting and testing complete all as specified and directed. Note : OLD SERVICEABLE VALVES TO BE DEPOSITED TO the DEPARTMENT store FOR FURTHER USE as directed by Engr-In-Charge.
100 mm Dia
150 mm Dia
S&F, connecting and testing in repair of Cast Iron foot Valves flanged ends swing type operation with rubber seat as per IS : 4038 single disc with all standard accessories and tested including replacement of nuts, bolts, washers, gaskets, packings etc complete all as specified and directed.
50 mm Dia
65 mm Dia
Cutting the existing road of any kind straight by manual, depth and width not less than 30 cm for pipes up to 100 mm dia and 60 cm for pipes from 150 mm to 150 mm dia and 75 cm for pipes above 400 mm dia and filling back with excavated soil up to 75 % road portion and 25 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate complete all as specified and directed.
M&L in repairs for Construction of new PCC solid Masonry valve chamber of size 1500 X 1500 X 1500 mm (Internal dimensions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick 150 mm wide off sets around over 100 mm thick hard core , 200 mm thick PCC solid block walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, without using extra cement internally including top of floor including excavation earth work in hard/Dense soil 3 mm thick MS sheet cover fixed on 40 mm X 40 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
M&L for painting of water distribution header including all control valves and all exposed pipe of any size by using synthetic enamelled spray painting after scrapping /cleaning complete all as directed .
Supply and lay in repairs MS black tubing ERW welded including specials , having outside dia of 212 mm and 6 mm thick ISI marked conforming to IS 3589 - 2001 with plain ends complete including connecting of MS pipes and specials by welding, leak testing of pipe line laid in trenches / floors / walls / ducts complete all as specified and as directed by the Engineer-in-charge. Note: Quoted rate is inclusive of supply and fixing of flange of suitable size, bends as required , welding and cutting etc as required for fixing of pipe .
Supply and lay in repairs Pipes MS black ERW Steel including specials having nominal dia 150 mm of thickness 6.0 mm as per IS 3589 - 2001, Grade - 330 with plain ends and specials by welding, leak testing of line laid in trenches / floors/ walls /ducts complete all as specified and directed. Note: Quoted rate is inclusive of supply and fixing of flange of suitable size as required, bends, welding and cutting etc as required for fixing of pipe .
Supply and lay in repairs Pipes MS black ERW Steel including specials having nominal dia 100 mm of thickness 6.0 mm as per IS 3589 - 2001, Grade - 330 with plain ends and specials by welding, leak testing of line laid in trenches / floors/ walls /ducts complete all as specified and directed. Note: Quoted rate is inclusive of supply and fixing of flange of suitable size as required , bends welding and cutting etc as required for fixing of pipe .
Core cutting / drilling of Bldg Roof / Wall for passing of GI Pipe up to 40 mm dia including necessary machineries complete all as specified and directed
Srinivash Engineers (BID ID -3271097)
Mavee Syndicate (BID ID -3277673)
VS ENTERPRISES (BID ID -3277722)
MS ENTERPRISES (BID ID -3275961)
M Shyam Sunder (BID ID -3274246)
THE DECAN ENGINEERING AND REFRIGERATION COMPANY (BID ID -3277835)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .