Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹1.4 L+₹177 (0.13%)Accepted-Finance NO 12 21 VENKATESWARA NAGAR VELACHERY CHENNAI TAMIL NADU 600042 | CHENNAI | TAMIL NADU | 600042 | L2 | Accepted-Finance L2 | |
| 3 | L3₹1.4 L+₹3,304 (2.34%)Accepted-Finance 2 4 J S TOWER G 4 BLOCK A AVVAIYAR STREET MEENAMBAKAM CHENNAI 600 027 | KANCHIPURAM | TAMIL NADU | 600027 | L3 | Accepted-Finance L3 | |
| 4 | L4₹1.5 L+₹5,664 (4.01%)Accepted-Finance | L4 | Accepted-Finance L4 |
Tender Value
Refer Docs
Closing Date
20 Feb 2024, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Principal
GPTC SEVVAPET
Supply of UPS for CSE
2024_DoTE_424606_1
248/B3/2024CSE UPS
Limited
Laboratory and scientific equipment
Supply
10 days
Sevvapet
Refer to PDF
2 documents required · 2 mandatory
₹0
Exempted
26 Feb 2024
14 Feb 2024
21 Feb 2024
14 Feb 2024
20 Feb 2024
14 Feb 2024
14 Feb 2024 - 20 Feb 2024
Supply of 10 KVA UPS FOR CSE
Capacity/Rating :l0 KVA General : UPS shall be free from workmanship defects, sharp edges,nicks, scratches, burrs, etc. All fasteners shall be fixed properly. The equipment shall be complete with all parts and all parts shall be functional. Technology : Microprocessor based Digital Control, IGBT based,True online double conversion, Ac to DC conversion and then DC to AC. Waveform : Pure Sine wave Input Voltage : 110-270V Input Frequency : 45-55Hz(Generator Compatible) Input Power Factor : >0.90 Out Voltage : 50Hz/60Hz+/-0.05% Output Power Factor : 0.9 Output Frequency : 50Hz/60Hz+/-0.05% THD : <2%Linear Load and 5%Non Linear Load. Inverter Efficiency : >92% Crest Factor : 3:l Over Load On Batteries : 105%-125% for at least 120sec, if overload exceeds UPSShall go in Bypass mode and auto recover on removal of load. Paralleling : Option for paralleling upto 4 Units. ByPass Switches : Option for paralleling upto 4 Units. Protection : Input Over/Under Voltage, Output Overload, Short Circuit,Battery Low/ High, Battery reversed polarity, protection for IGBT & thermal overload. Display : LCD. Alarms : Audible Alarms should be provided for Mains Fail, BatteryLow and Fault Conditions. Operating Conditions : 0-40degC,0-90%RH maximum, non condensing audible noise-50Db at front 1meter. Cooling : Air forced type Software support : Novel Netware/UNIX/Windows NT/Solaris Minimum VAH Required : 10800(Bidders can choose battery capacity accordingly) Capacity/Rating :l0 KVA Make of UPS : EATON/EMERSON/APC/SOCOMEC/NUMERIC General : UPS shall be free from workmanship defects, sharp edges,nicks, scratches, burrs, etc. All fasteners shall be fixed properly. The equipment shall be complete with all parts and all parts shall be functional. Technology : Microprocessor based Digital Control, IGBT based,True online double conversion, Ac to DC conversion and then DC to AC. Waveform : Pure Sine wave Input Voltage : 110-270V Input Frequency : 45-55Hz(Generator Compatible) Input Power Factor : >0.90 Out Voltage : 50Hz/60Hz+/-0.05% Output Power Factor : 0.9 Output Frequency : 50Hz/60Hz+/-0.05% THD : <2%Linear Load and 5%Non Linear Load. Inverter Efficiency : >92% Crest Factor : 3:l Over Load On Batteries : 105%-125% for at least 120sec, if overload exceeds UPSShall go in Bypass mode and auto recover on removal of load. Paralleling : Option for paralleling upto 4 Units. ByPass Switches : Option for paralleling upto 4 Units. Protection : Input Over/Under Voltage, Output Overload, Short Circuit,Battery Low/ High, Battery reversed polarity, protection for IGBT & thermal overload. Display : LCD. Alarms : Audible Alarms should be provided for Mains Fail, BatteryLow and Fault Conditions. Operating Conditions : 0-40degC,0-90%RH maximum, non condensing audible noise-50Db at front 1meter. Cooling : Air forced type Software support : Novel Netware/UNIX/Windows NT/Solaris Minimum VAH Required : 10800(Bidders can choose battery capacity accordingly)
JAYAM ELECTRONICS
BESTMACH
KUTTY ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .