Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹21.7 L+₹1.7 L (8.37%)Rejected-Finance | L2 | Rejected-Finance Quoted other than lowest rate | |
| 3 | L3₹22.3 L+₹2.3 L (11.4%)Rejected-Finance | L3 | Rejected-Finance Quoted other than lowest rate | |
| 4 | L4₹25.5 L+₹5.5 L (27.4%)Rejected-Finance | L4 | Rejected-Finance Quoted other than lowest rate | |
| 5 | L5₹34.6 L+₹14.6 L (73.2%)Rejected-Finance MULTICARE ENTERPRISES PRIVATE LIMITED COMMERCIAL COMPLEX VARDHMAN TOWER PREE T VIHAR G 63 GROUND FLOOR PLOT NO 16 17 18 110092 DELHI EAST DELHI N N 110092 | EAST DELHI | DELHI | 110092 | L5 | Rejected-Finance Quoted other than lowest rate |
Tender Value
₹13.8 L
EMD Value
₹27,600
Closing Date
10 Sept 2022, 6:00 pmClosed
SH ASHOK KUMAR, EE, IDSE
GE NORTH BATHINDA BATHINDA MIL STN PIN 151004
REPAIR AND REPLACEMENT OF INTERNAL WIRING AND LIGHT POINT AT BLDG No. T-1191, T-1188, T-1189, T-1184, T-1182, T-1183, T-1190, T-1193, T-1194, T-1195, T-1197, T-1211 T-1899 AND SPL REPAIR/REPLACEMENT OF INTERNAL ELECTRIC WIRE AND CONNECTED MISC ITEM
2022_MES_539678_1
8937/NIT-41/22-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE NORTH BATHINDA
Class E category b (i)
8 documents required · 8 mandatory
₹500
GE NORTH BATHINDA
₹27,600
Yes
23 Sept 2022
21 Jul 2022
12 Sept 2022
21 Jul 2022
10 Sept 2022
29 Aug 2022
21 Jul 2022 - 28 Jul 2022
Amount
SCHEDULE 'A' ELECTRIFICATION WORKS
Taking down carefully existing unserviceable copper/aluminium point wiring (light/fan/socket or power point) complete with all accessories such as hylum sheet, switches, sockets, ceiling rose, wall brackets, regulator gang boxes etc & making good distrubed surfaces of walls/floor etc and matching with existing surface all as specified and directed by Engr - in- Charge
Material & Labour for surface point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLSH PVC insulated unsheathed and multi stranded copper conductor FRLSH cable (ISI marked) 1100 volts drawn through and including PVC casing caping (heavy duty) suitable size as directed with all fittings and all accessories but including 3mm thick bakelite laminated hylem sheet (fixed with brass screws & cup washers)(ISI marked) for mounting of switches and socket, fan regulator, for one light point /fan point/exhaust fan controlled by one switch including provn of 1.5 Sqmm single core multi stranded FRLSH copper earth wire to common earth and connecting to earthh dolly, complete all as specified and directed by Engr - in- Charge Make:- Havells/Polycab/Dcab/finolex/Anchor
All as per item No 2 here in before but for socket outlet 5 pin 5/6 Amp 250 Volts on same board, complete all as specified and as directed by Engineer-in-Charge.
All as per item No 2 here in before but for socket outlet 5 pin 5/6 Amp 250 Volts on independent board but not below the switch board, complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 2 here-in-before but socket out let one 6 pin, 6/16 Amps, 2 in 1 with cable 2.5 Sqmm multistranded copper conductor FRLSH cable on the independent board including provision of 2.5 Sqmm PVC insulated copper conductor FRLSH cable continuos as earth wire connected to earth dolly conductor etc., complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully existing unserviceable copper/aluminium point wiring (light/fan/socket or power point) complete with all accessories such as hylum sheet, switches, sockets, ceiling rose, wall brackets, regulator gang boxes etc & making good distrubed surfaces of walls/floor etc and matching with existing surface complete all as specified and directed by Engr - in- Charge
Material & Labour for point wiring with multi stranded copper conductor FRLSH cable, 1100 volts grade PVC insulated and unsheathed of size 1.5 sqmm single core in and including PVC concealed conduit not less than 20mm dia (medium duty ISI marked) and conduit fittings with and including 3mmm thick bakelite laminated sheet top cover for one fan/ light controlled by one switch including provison of 1.5 sqmm PVC insulated & unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dollycomplete all as specified and directed by Engr - in- Charge Make:- Havells/Polycab/Dcab/finolex/Anchor
All as per item No 7 here in before but for socket outlet 5 pin 5/6 Amp 250 Volts on same board, complete all as specified and as directed by Engineer-in-Charge.
All as per item No 7 here in before but for socket outlet 5 pin 5/6 Amp 250 Volts on independent board but not below the switch board, complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 7 here-in-before but socket out let one 6 pin, 6/16 Amps, 2 in 1 with cable 2.5 Sqmm multistranded copper conductor FRLSH cable on the independent board including provision of 2.5 Sqmm PVC insulated copper conductor FRLSH cable continuos as earth wire connected to earth dolly conductor etc., complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully existing unserviceable copper/aluminium point wiring (light/fan/socket or power point) complete with all accessories such as hylum sheet, switches, sockets, ceiling rose, wall brackets, regulator except concealed conduit and sunken boxes etc. & making good distrubed surfaces of walls/floor etc. and matching with existing surface all as specified and directed by Engr - in- Charge.
Material & Labour for point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLSH copper cable (ISI marked) 1100 volts grade with multi stranded copper conductor drawn through and including non mettalic, rigid non mettalic PVC conduit (medium grade) concealed in wall/ceiling with and including 1.5 Sqmm single core PVC insulated, multi stranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) including modular metal flush box & modular cover plate with frame suitable matching colour of required module for mounting or housing switches, sockets outlets, fan regulators, etc., including blanking plates & all other fixing accessories for one light/fan/exhaust fan point controlled by one 5/6 Amps switch and including cutting chases (as required) and making good surfaces to match with adjoining surfaces, complete all as specified and directed by Engr - in- Charge Make:- Havells/Polycab/Dcab/finolex/Anchor
All as per item No 12 here in before but for socket outlet 5 pin 5/6 Amp 250 Volts on same board, complete all as specified and as directed by Engineer-in-Charge.
All as per item No 12 here in before but for socket outlet 5 pin 5/6 Amp 250 Volts on independent board but not below the switch board, complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 12 here-in-before but socket out let one 6 pin, 6/16 Amps, 2 in 1 with cable 2.5 Sqmm multistranded copper conductor FRLSH cable on the independent board including provision of 2.5 Sqmm PVC insulated copper conductor FRLSH cable continuos as earth wire connected to earth dolly conductor etc., complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 12 here-in-before but for bell/buzzer point, complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 12 here-in-before but two way point controlled by two two way switch with cable 1.5 Sqmm, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing switch piano flush type, single pole, one way, 5/6 Amps ISI mark, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing switch piano flush type , single pole, one way, 15/16 Amps ISI mark, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Socket outlet multipurpose, 2 in 1, 5 pin, 5/6 Amps, flush type, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Socket outlet multipurpose , 2 in 1, 5 pin, 15/16 Amps, flush type, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing modular switch, single pole, one way, 5/6 Amps, one module, ISI marked, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing modular Socket outlet multipurpose, 2 in 1, 2/3 pin, 5/6 Amps, two module, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing modular switch, single pole, one way, 15/16 Amps, one module, ISI marked, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing modular Socket outlet multipurpose , 2 in 1, 2/3 pin, 15/16 Amps, two module, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing modular bell push 6 Amps, one module, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing modular switch, single pole, two way, 5/6 Amps, one module, ISI marked, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing calling bell AC 230 Volts single pole ding dong, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling rose surface type polycarbonate, isolated body two to three terinal,, tpline series 20 x 50mm, 6 Amps, three terminal, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing stepped type (1-4), electronic modular Fan regulator (two module), 100 watt, 250 volts, fixed on laminated sheet suitable for ceiling fan, complete all as specified by Engineer-in-charge.
Supply and fixing lamp holder PVC/Polycarbonate cased body of brass with back plate suitable for batten fittings complete including 9w LED bulb, complete all as specified and as directed by Engineer-in-Charge. Make of holder : Anchor/Havells/Legrand/Indoasian/SSK and Make of LED bulb :- Crompton/Philips/Bajaj/Havells
Supply and fixing wall mounted Retro LED 20 watt, Batten decorative type, appx 4 feet long, pre wired including LED tube light 20W, 6000K with inbuilt driver complete fitting and all other accessories fitting arrangements including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector including taking down old unserviceable light fittings any type complete all as specified and as directed by Engineer-in-Charge. Make - Cat part No. LT8-20-865-2 of Crompton/Havells/Wipro/Philips
Supply and fixing in replacement recessed LED ceiling light with wide light window for maximized glare free output suitable for 600x600mm and ceiling cutout 595x595mm modular grid/POP ceiling complete fitting with separate electronic driver and high brightness SMD LEDs 36 watt (100 lumens per watt), 6000K and one nos extra LED driver along the fittings including connecting electric connection, complete all as specified and directed by Engineer-in-Charge. Make - Crompton/Havells/Wipro/Philips
Supply and fixing in replacement round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed by Engineer-in-Charge. Make - Crompton/Havells/Wipro/Philips
Supply and fixing LED mirror light fiting 9/10 watt, 6000K, lineer & compact with decorative grey end caps, polycarbonate body and ribbed opal diffuser complete fitting with lamp and all other accessories fitting arrangements including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector, including taking down old unserviceable light fittings any type, complete all as specified and as directed by Engineer-in-Charge. Make - Crompton/Havells/Wipro/Philips
Supply and hanging /fixing in replacement of ceiling fan 1200 mm sweep in white/off white colour, 50watt, copper winding, 3 Blade, single phase, 230 volts 50 Hz double ball bearing, energy saver/energy-efficient, alongwith hanging rod (length as per site requirement or as directed by Engineer-in-charge), canopy (lower and upper), rubber real, nut bolts, lock pin etc. including making electrical connection with flexible round twin core multi strand copper cable suitable size complete all as specified and as directed by Engineer-in-Charge. Make and cat part :- Entrust 50 of Crompton / Energia of USHA / ES 50 of Havelles / Electra 50 of Bajaj Note :- (i) Srl Number of ceiling fan and 'GE North BTD' shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Ceiling fan installed/hanging at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account (iii) Old rusted and outdated ceiling fans deposited to MES store cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account
Supply and hanging /fixing of ceiling fan 1200 mm sweep in white/off white colour, 50watt, copper winding, 3 Blade, single phase, 230 volts 50 Hz double ball bearing, energy saver/energy-efficient, alongwith hanging rod (length as per site requirement or as directed by Engineer-in-charge), canopy (lower and upper), rubber real, nut bolts, lock pin etc. including making electrical connection with flexible round twin core multi strand copper cable suitable size complete all as specified and as directed by Engineer-in-Charge. Make and cat part :- Entrust 50 of Crompton / Energia of USHA / ES 50 of Havelles / Electra 50 of Bajaj Note :- (i) Srl Number of ceiling fan and 'GE North BTD' shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Ceiling fan installed/hanging at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account
Taking down ceilling fan from site and keep in safe custody/store for reuse the same as same location after the building work. Before reinstall the same will be new spray painted as per existing colour compelete all as directed by Engineer-in-Charge. If any damages of fans and its connected acessories at the time of transportation/deposit to store, the contractor will response the same included in the quoted rate.
Supply and fixing in replacement (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 8 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 12 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.
Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet) TPN, 4 Way 433 V (8+12 modules), double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.
Supply, installation, testing & commisioning of outdoor LT panel board protection class IP65, 415-433V made out of 2.0 mm thick RAL 7032/7035 coated CRCA steel, dust and vermin proof, double door complete prewired, with locking arrangements and hanging bracket suitable for fixing arrangements, including painting with powder coated paint over a coat of redoxide zinc crome primer complete including necessary internal wiring for MCCBs with gland comprising and suitable size following electric safety equipments inserted in this panel comprising of the following:- (a) Way for Incomer 200 Amps 4 pole MCCB as per existing size and type -01 No (b) R Y B phase Indicating lamps - 01 Set (set of three) (c) insulated Copper Busbars 200 Amps rating - 04 Nos (d) Way for outgoing MCCB 125 Amps 4 pole -03 No (e) Way for outgoing MCCB 63 Amps 4 pole -01 Nos (f) Provision of digital Voltmeter suitable for 0-500 Volts AC (g ) Provision of Ampere meter suitable for 0-200 Amps Make:- C&S/Universal switch gear control / Powertech / Rajeev associats / Hensel Electric india pvt ltd
Supply and fixing MCB SPN 63 Amps, 10 KA 'C' curve 230 V AC, 50 Hz including necessary attachment, including taking down unserviceable old MCB, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCCB TPN 125 Amps, including necessary attachment, including taking down unserviceable old MCCB, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB SP suitable for 230 volts AC supply 6 to 40 Amps, SP rupturing capacity not less than 10KA, C Curve ISI Marked, 1 Module, including taking down unserviceable old MCB, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos- 8mm dia 25mm long hex head screw. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, CI cover 10mm thick hanged to CFI frame, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate), including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I), including dismantling of old unserviceable earthing, complete all as specified and and as directed by Engineer-in-charge.
Supply & fixed provision of storage type water heater (Geyser) electrical operated 230/240 Volts 25 litre capacity, BEE 5 star rated complete with all safety equipment and accessories such as safety valve, thermostat, plug top, etc. required for proper functionality & including electric/earth connections and carrying out grounting & complete installations with mounting bolts, nuts inclucding testing after installation complete all as specified & directed. Make - Bajaj / HAVELLS / Crompton Greaves/V guard Note :- (i) Srl Number of Gyeser and 'GE North BTD' shall also be writing on Gyeser with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Gyeser installed at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account.
Supply and fixing bib tap cast copper alloy, chromium plated with crutch or butterfly handle with capstan head, wall flange, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply & fixing 600 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge.
Supply and fixing stop valve/angle valve cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed both end for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Material and labour for concealed sub main wiring with 4 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB and including one run 4 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 4 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Material and labour for conncealed sub main wiring with 4 runds of 10 sqmm main wire along with 2 run of 6 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded,1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same, including taking down old unserviceable sub main wiring, complete all as specified and directed. (Note. four runs of main copper conductor, two run of earth wire and one run of PVC conduit shall be measured as one length.)
Material and labour for concealed sub main wiring with 2 runs of 6 sqmm main wire along with 1 run of 6 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessoires including cutting chases for conduits as required, sinking for terminal boxes, marking good the same,including taking down old unserviceable sub main wiring, complete all as specified and directed. (Note. Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length)
Material and labour for concealed sub main wiring with 2 runs of 4 sqmm main wire along with 1 run of 4 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & Accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same,including taking down old unserviceable sub main wiring, complete all as specified and directed, (Note. Two run of main copper conductor, one run earth wire and one run of PVC conduit shall be measured as one unit length.)
Supply and fixing exhaust fan 300 mm sweep (BEE, 5 star rated) with louvres, 230V, single phase AC supply, hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface as per existing surfaces, and connection to fan with suitable flexible twin core round copper wire complete all as specified and directed by Engineer-in-Charge. Make - Usha / Bajaj / Khaitan / Orient / Crompton / Polar Note :- (i) Srl Number of exhaust fan and 'GE North BTD' shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Exhaust fan installed/hanging at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account
Supply and fixing (concealed in wall or as directed) single pole and neutral sheet metal enclosure (AC/geyser Box) with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply, including taking down old unserviceable MCB, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing (concealed in wall or as directed) single pole and neutral sheet metal enclosure (AC/geyser Box) with a two pin and earth plug and socket complete with one single pole MCB of capacity 25 Amps, 240 volts, AC supply, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing (concealed in wall or as directed) single pole and neutral sheet metal enclosure (AC/geyser Box) with a two pin and earth plug and socket complete with one single pole MCB of capacity 32 Amps, 240 volts, AC supply, including taking down old unserviceable MCB, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 04 Way 230/240V, double door, earth bar, 200 Amp rated copper bus bar and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof and including making good disturbed surfaces of walls as necessaty, including taking down unserviceable old DB any type including MCB etc., complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing MCB SPN 40 Amps, 10 KA 'C' curve 230/240 V AC, 50 Hz including necessary attachment including taking down old unserviceable MCB SPN, complete all as specified and directed by Engineer-in-charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as required) and making good disturbed surfaces of walls including cutting and threading of existing pipe any dia for insertaion of tee branch including hole in wall to pass the pipe out side for connection as per site requirment, including taking down old unserviceable tubing, complete all as specified and as directed by Engineer-in- charge.
Supply, laying, jointing and testing XLPE LT Cable of size 16 Sqmm, 2 core, 1100 Volt grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I), laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling, including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge. Note :- (i) Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured & paid separately under appropriate item of this Schedule.)
Supply, laying, jointing and testing XLPE LT Cable of size 50 Sqmm, 4 core, 1100 Volt grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I), laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling, including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge. Note :- (i) Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured & paid separately under appropriate item of this Schedule.)
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cess pits, manholes, for taking out old pipe and laying new pipe line, for laying cable etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
Supply and filling Local sand cushioning , with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR–Part-I before laying of cable and 150mm thick after laying of cable complete all as specified and as directed by Engineer-in-Charge. (Note :- For measurement purpose puned thickness shall be measured and paid i.e 18cm.)
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing/laying GI tubing, light grade, 40 mm bore for protection of cable or earthing lead wire under hardstanding/fixed along poles/wall, laid in in trenches etc., including taking down old unserviceable tubing complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Sleek Pressue die cast aluminium housing, heat resistant glass, energy saving, IP-65 protection, better optics for uniform distribution street/Roadway luminaire with high power LED 25/35 Watt compete fitting with driver, LED strip and all other accessories etc. suitable GI bracket and making electric connection with using twin core copper cable of suitable size including taking down old unserviceable light fitting any type, complete all as specified and as directed by Engineer-in-Charge. Make - Crompton/Havells/Wipro/Philips
Supply and fixing connection of PVC insulated, unseathed multistranded, three core twisted copper flexible cable of size 1.5 Sqmm as required, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for point wiring for one light/fan point/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLSH, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistrand FRLSH, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid/non metallic conduit and connecting with existing CI/pressed steel terminal boxes including 3mm thick hylam brand IS-2036 marked, laminated top sheet cover for mounting switches, sockets, fan regulators etc. , complete all as specified and as directed by Engineer-in-Charge. (A) One light point controlled by one 5 Amp switch one way Note:- (a) Wiring shall be done by using proper colour coding (b) Earth wire shall be of green colour
Labour for fixing of 4 Nos. rawl plug of suitable size (4" - 6") nuts & bolts, grouting work in RCC/brick wall, cemented works labour charges for cutting to existing GI pipe line of size 15mm dia in position for insertion of tee or branch connection jointing complete with necessary GI fittings, plumbing work all as per site requirement, complete all as specified and as directed by Engineer-in-Charge.
Labour for cutting to existing GI pipe of size 25/20mm dia in position for addition/alteration or insertion of TEE for branch connection complete with cutting, threading and jointing/fixing including GI fitting as per site requirement, complete all as specified and as directed by Engineer-in-Charge.
NASIB ENGINEERS AND CONSTRUCTION
M/s VISHAL ELECTRIC STORE
M/s GURFATEH BUILDERS
Multicare Enterprises Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .