| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC | L1 | Accepted-AOC DUE TO BEING L1 AND REASONABLE | |
| 2 | L2₹25.7 L+₹2.8 L (12.0%)Rejected-Finance | L2 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 3 | L3₹28.6 L+₹5.6 L (24.5%)Rejected-Finance | L3 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 4 | L4₹28.9 L+₹5.9 L (25.8%)Rejected-Finance ALIPURDUAR | ALIPURDUAR | WEST BENGAL | 735204 | L4 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 5 | L4₹29.7 L+₹6.8 L (29.4%)Rejected-Finance | L4 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
8 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (SOUTH) AKHNOOR
GE (SOUTH) AKHNOOR C/O 56APO
CLEANING OF SEWAGE LINES AND REPAIR /MAINT OF SEWAGE SYSTEM AT SOUTH BANK AND NORTH BANK UNDER AGE B/R-I UNDER GE (SOUTH) AKHNOOR.
2023_MES_585394_1
GES/AKH-74/2022-23
Open Tender
Civil Works
Item Rate
330 days
GE (SOUTH) AKHNOOR
MES EN-LISTED CONTRACTOR WITH CLASS D AND ABOVE WITH CATEGORY a(ii)
9 documents required · 9 mandatory
₹500
GE (SOUTH) AKHNOOR
₹60,000
10 May 2023
11 Mar 2023
10 Apr 2023
11 Mar 2023
8 Apr 2023
25 Mar 2023
Amount
Removing of manholes covers (any type) and dewatering/ pumping/ bailing out of contaminated water including cleaning of sludge and night soil from septic tanks/ soakage wells of any capacity and depth alongwith inlet/ outlet chambers etc by vehicle mounted sewage suction machine including pumping out the contaminated water in open drain/ low lying area to a distance exceeding 50mtr and removing the sludge, silt etc. (solid waste materials) to outside of Unit/ Cantonment area and putting back manhole covers in original position including spreading bleaching powder on top of septic tanks/ soakage wells to make it hygienically fit, complete all as specified and as directed by Engineer-In-Charge. Note: (i) Actual quantity of sludge/ waste material only shall be measured after dewatering the septic tanks only, the sludge shall be carried away in the sewage carrying tankers, of minimum capacity 7000 Ltrs each. (ii) Cost of dewatering/ pumping out of contaminated water from septic tanks and soakage well shall deemed be included in quoted rates.
Dismantling of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed by Engineer-In-Charge.
Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
All as per srl Item No 3 but except bricks.
Rendering 10mm thick on bricks or concrete masonry surfaces, on walls, in cement mortar 1:4, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for, including cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed by Engineer-In-Charge.
Reinforced cement concrete M-20(1:1.5:3), type A-1, (using 20mm graded crushed stone aggregate), nominal mix, as in slabs supported on walls, beams and columns, roofs, landings, deck slabs and in shelves and the like, complete all as specified and as directed by Engineer-In-Charge.
Precast reinforced cement concrete M-20(1:1.5:3), type A-1, (using 20mm graded crushed stone aggregate), nominal mix, as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs and similar articles with plain faces as specified in clause No- 4.11.16 of SSR Part-I (2009), set in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed by Engineer-In-Charge.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 150/ 200mm bore, set in cement mortar, complete all as specified and as directed by Engineer-In-Charge.
Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-In-Charge.
Formwork for smooth finish surfaces to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified and as directed by Engineer-In-Charge.
Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; for laying sewage line, not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type C-2 (using 40mm crushed stone aggregates) as in bed to drain pipes of 200mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; after laying, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type C-2 (using 40mm crushed stone aggregates) as in bed to drain pipes of 150mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; after laying, complete all as specified and as directed by Engineer-In-Charge.
Salt-glazed stoneware drain pipes, internal 200mm, laid in trenches and jointed in cement mortar 1:1, complete all as specified and as directed by Engineer-In-Charge.
Salt-glazed stoneware drain pipes, internal 150mm, laid in trenches and jointed in cement mortar 1:1, complete all as specified and as directed by Engineer-In-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed by Engineer-In-Charge.
Removing excavated materials/ soils, to a distance exceeding 50mtrs but not exceeding 250 mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for, including cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type C-2 (using 40mm graded crushed stone aggregate), 75mm thick, as in plinth protection, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-15(1:2:4), type B-1, (using 20mm graded crushed stone aggregate), nominal mix, as in copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work, complete all as specified and as directed by Engineer-In-Charge.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580x440mm white, with integral foot rests (excluding flushing cistern and flush pipe) but including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to dismantled floor in cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregates), fixing in repair, complete all as specified and as directed by Engineer-In-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engineer-In-Charge.
Non-skid, coloured, ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 Per Square Metre but not exceeding 0.18 Per Square Metre, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Attending complaints of sewage blockage by cleaning and removal of sludge/ night soil and garbage from manholes, W.C. and sewage lines including cleaning any blockage from gully/ nahani/ floor trap/ W.C. etc up to first manhole, by Skilled manpower, in one shift of eight Hours per day (from 900 Hrs to 1700 Hours) for attending complaints of sewage cleaning as instructed by concerned JE with complaint slip and report back to the same JE, including maintaining of the record of complaint slips after getting signature of users, complete all as specified and as directed by Engineer-In-Charge. Note: (i) Nos of man power will be decided by Engineer-In-charge and decison of Engineer-In-charge shall be final and binding to contractor without any extra claim to Govt. (ii) Detailed notes of this item are mentioned on serial page No- 22 of tender here-in-after.
Dismantling/ taking out of cast iron drain pipes of 100mm bore (of any specifications), as fixed on walls or laid in trenches, complete all as specified and as directed by Engineer-In-Charge.
Dismantling/ taking out of cast iron drain pipes of 75mm bore (of any specifications), as fixed on walls or laid in trenches, complete all as specified and as directed by Engineer-In-Charge.
Cast iron sand cast soil, waste and vent pipes, 100mm bore, in any length with or without ears, with cement joints, fixed on walls, complete all as specified and directed by Engineer-In-Charge.
Cast iron sand cast soil, waste and vent pipes, 75mm bore, in any length with or without ears, with cement joints, fixed on walls, complete all as specified and directed by Engineer-In-Charge.
Cast iron bends, 100mm bore pipe (any radius), with duck's foot or heel rest, complete all as specified and as directed by Engineer-In-Charge.
Cast iron bends, 75mm bore pipe (any radius), with duck's foot or heel rest, complete all as specified and as directed by Engineer-In-Charge.
Cast iron branch pieces, 100mm bore pipe, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, complete all as specified and as directed by Engineer-In-Charge.
Oval access doors with seal suitable for 100mm/ 75mm bore cast iron fittings i.e. bends, junctions etc, complete all as specified and as directed by Engineer-In-Charge.
Cast iron branch pieces, 75mm bore pipe, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, complete all as specified and as directed by Engineer-In-Charge.
Cast iron ‘P’ or ‘S’ trap, with grating of 100mm outlet dia including jointing to waste pipe fixed in plain cement concrete, M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates), complete all as specified and as directed by Engineer-In-Charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and as directed by Engineer-In-Charge.
PVC (SWR) pipes, 110mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, single socketed, in any length with rubber ring joints, fixed on wall with mild steel/ PVC clamps, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
PVC (SWR) bends of 110mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, any radius, fixing with adhesive, fixed in repair, complete all as specified and as directed by Engineer-In-Charge.
Cleaning of blocked/ choked SGSW/ Cast Iron drain pipes/ sewer lines of any dia and any types, in horizontal position by rodding, after first manhole, from manholes to manholes and manholes end to septic tanks/ soakage wells, flushing with pressure jet of water/ sewage suction machine after taking out existing manholes covers and putting back manhole covers in original position after cleaning of lines including removing the sludge and other waste materials/ blockage in drain pipes, transport to outside of Unit/ Cantonment area and spreading bleaching powder on top of manholes covers of septic/ soakage pits or in the surrounding areas to make hygienically fit, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of transportation of waste materials shall be deemed included in quoted rates.
Amount of Schedule of credit of for Rs 71,190.00 shall be deducted from quoted amount.
CHOPRA CONSTRUCTIONS
KRISHNA BUILDERS
M/s Shivam Construction Co
harish kumar and co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .