Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹41.5 LAdmitted-Finance | -23.52% | ₹41.5 L | L1 | Admitted-Finance |
| 2 | L2₹42.6 L+₹1.1 L (2.63%)Admitted-Finance | -21.51% | ₹42.6 L+₹1.1 L (2.63%) | L2 | Admitted-Finance |
| 3 | L3₹42.8 L+₹1.3 L (3.02%)Admitted-Finance | -21.21% | ₹42.8 L+₹1.3 L (3.02%) | L3 | Admitted-Finance |
| 4 | L4₹43.1 L+₹1.6 L (3.91%)Admitted-Finance | -20.53% | ₹43.1 L+₹1.6 L (3.91%) | L4 | Admitted-Finance |
| 5 | L5₹44.8 L+₹3.3 L (7.86%)Admitted-Finance | -17.51% | ₹44.8 L+₹3.3 L (7.86%) | L5 | Admitted-Finance |
Tender Value
₹54.3 L
EMD Value
₹1.1 L
Closing Date
19 Aug 2026, 11:00 amClosed
Executive Engineer PHED Rural Dn Bhilwara
BHILWARA
RIICO RUPAHELI
2026_PHCJA_582717_1
NIT NO 24/2026-27 EE PHED RURAL DN BHILWARA
Open Tender
Civil Works
Percentage
121 days
BHILWARA
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,000
Executive Engineer PHED Rural Dn Bhilwara
₹1.1 L
Yes
7 Sept 2026
6 Aug 2026
19 Aug 2026
6 Aug 2026
19 Aug 2026
6 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing, lowering, laying in trenches, aligning, fixing in position and
jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work)
Note : Providing and fixing of all requisite specials as per drawing, design
and layout are inclusive in RM measurement of the item and shall not be paid separately. | - | - | - | - |
| 2 | 100 mm K-7 | - | RMT | 1,464 | - |
| 3 | Earth work in excavation by mechanical means (Hydraulic Excavator )/
manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:
All kinds of soil | - | Cum | 200 | - |
| 4 | Earth work in excavation by mechanical means (Hydraulic Excavator )/
manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: | - | - | - | - |
| 5 | Ordinary Rock | - | Cum | 365 | - |
| 6 | Hard Rock (Blasting Prohibited) | - | Cum | 782 | - |
| 7 | Providing and fixing of flanged/ plain ended MS Specials made from MS
sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. | - | - | - | - |
| 8 | MS pipe specials upto 600mm dia (with minimum 5mm thickness
sheet) | - | Per kg | 126 | - |
| 9 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make
of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/ Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output
: RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category-IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection with existing pipeline including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.
Note: Rates are exclusive of tail piece / dismantling joints and earth work. | - | - | - | - |
| 10 | EFM 80 mm | - | Each | 1,03,636 | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.56 MB
sppp.pdf
Tender Documents • 4.53 MB
BOQ_1035273.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .