Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹45.8 LAccepted-AOC GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | 1 | Accepted-AOC L-1 | |
| 2 | 2₹48.4 L+₹2.5 L (5.44%)Rejected-Finance 736 PARAGDAS MANDIR NIRMOCHAN GHAT AYODHYA 224123 | AYODHYA | AYODHYA | UTTAR PRADESH | 224123 | 2 | Rejected-Finance Being other than L-1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
4 Dec 2021, 6:00 pmClosed
GE EAST LUCKNOW
GE EAST LUCKNOW
PROVN OF DRAINS AND CULVERTS AT AMC OFFICERS MESS AND PROVN OF TOILET BLOCK NEAR ATTACH LINE BLDG NO AL-103 AND CERTAIN OTHER SANCTIONED WORK OF AGE B/R-II AND AGE E/M UNDER GE (EAST) LUCKNOW (SECOND CALL)
2021_MES_481856_2
GE/E/LKO/T-41 of 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE EAST LUCKNOW
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE EAST LUCKNOW
₹90,000
Yes
13 Jan 2022
13 Nov 2021
6 Dec 2021
13 Nov 2021
4 Dec 2021
22 Nov 2021
Amount
Surface excavation soft/loose soil not exc 30 cm deep and averaging 15cm deep and getting out soil complete all as specified and directed.
Excavating in post holes (or similar holes) in soft/loose soil, each not exc 0.5 cum each hole, getting out, and removing soil to a distance not exc 50m complete all as specified and directed.
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for foundation, trenches etc and getting out in soft/loose soil complete all as specified and directed
Removing of excavated materials to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed
Earth filling under floor, including spreading, leveling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed. Note : Earth obtaind from excavation shall be used for filling.
M&L for cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations filling, sub base and mass concrete filling, etc complete all as specified and directed
M & L for mild steel works as in framed work such as gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes , walk ways, railings, framework of water tanks and similar work complete all as specified and directed
M&L for mild steel TMT bars 10 mm dia and over as in reinforcement cut to length, bent in shape required including cranking, bending, spirally hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed
M&L for mild steel TMT bars 6 to 8 mm dia and over as in reinforcement cut to length, bent in shape required including cranking, bending, spirally hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed
M&L for mild steel TMT bars 5 mm dia and over as in reinforcement cut to length, bent in shape required including cranking, bending, spirally hooking ends and binding with and including 10 mm dia in stirrups, spacers and binders complete all as specified and directed
M&L for RCC 1:1½ :3 type A1 (using 20 mm graded stone aggregate) as in foundations, footings, plinth beams bases for columns, etc. complete all as specified and directed
M&L for RCC 1:1½ :3 type A1 (using 20 mm graded stone aggregate) as in column, pillars, piers, posts and struts etc complete all as specified and directed
M&L for RCC 1:1½ :3 type A1 (using 20 mm graded stone aggregate) as in wall of drains, any thickness above top of footings etc complete all as specified and directed
M&L for RCC 1:1½ :3 type A1 (using 20 mm graded stone aggregate) as in roof slabs, shelves etc complete all as specified and directed
M&L for RCC 1:1½ :3 type A1 (using 20 mm graded stone aggregate) as in chhajja complete all as specified and directed
M&L for RCC 1:1½ :3 type A1 (using 20 mm graded stone aggregate) as in roof beam, bands, lintel beam, etc complete all as specified and directed
M&L for formwork to sides of concrete in foundations, footings, bases of columns, sides and soffits (if any) plinth beams, and similar work complete all as specified and directed
M&L for formwork to sides of concrete of pillars, posts, struts, piers, columns etc complete all as specified and directed
M&L for form work to soffits of roof slabs, floor slabs and similar work not exc 200 mm thick fair finished surfaces (flat) complete all as specified and directed
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
M&L for formwork to faces of walls, retaining walls, abutments and similar work complete all as specified and directed
M&L for formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed
M&L for formwork to edges of concrete flats, roofs and sides of RCC/ PCC bands in walls, and similar work exc 10 cm but not exc 20 cm wide complete all as specified and directed
M&L for formwork to edges of concrete flats, roofs and sides of RCC/ PCC bands in walls, and similar work exc 5 cm but not exc 10 cm wide complete all as specified and directed
M&L for brick work with fly ash bricks, straight or curved on plan exc 6M mean radius, old size brick built in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work with fly ash bricks, straight or curved on plan to any radius as in half brick thick wall built in CM 1:4 complete all as specified and directed
Demolition of brick/stone masonary including all quoins, pillars etc, built in cement mortar complete all as specified and directed
M&L for PCC 1:2:4, type B-0, with 12.5mm stone aggregate 40 mm thick in Damp Proof Course to horizontal or vertical surfaces including necessary formwork using water proofing compound as per manufacture's instruction and incl a coating of bitumen primer complete all as specified and directed. (Note:- WPC shall be measured and paid seperately as 'Supply only').
M&L for plastering 15 mm thick in CM 1:4 on fair faces of brick or concrete surfaces, finished the surface even and smooth with using WPC @ 2% by weight of cement complete all as specified and directed. (Note- WPC shall be measured and paid separately as 'Supply only').
M&L for 10mm thick cement plaster on other than fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth complete all as specified and directed
M&L rendering 5mm thick in CM 1:3 as in ceiling ,soffits of slab and finish the surface even and smooth without using extra cement complete all as specified and directed
M&L for plastering 15 mm thick in CM 1:4 on fair faces of brick or concrete surfaces, finished the surface even and smooth complete all as specified and directed
M&L for 15 mm thick cement plaster in CM 1:3 on top of RCC roof slab with using water proofing compound 3% by weight of cement, finish the surface even & fair complete all as specified and directed
M&L for 100mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregates as in sub base of floors complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 300x600x 7mm thick over and including 10mm thick rendering in CM 1:4 on vertical surfaces such as skirting, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and drected
M&L for non skid ceramic coloured tiles 400x400x 7mm thick in floors etc. over and including 15mm thick screed bed in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for 18 to 20 mm thick granite for (of any type) machine cut and polished in steps, jambs, pillar window cill, cooking plateform etc laid over and including 20 mm thick screed bed in CM 1:4 , bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed
S&F 60 mm thick, machine pressed rubber moulded, glossy coloured, precast concrete interlocking paver block any shape and size of M-35 grade of approved shade laid over 25mm thick sand cushion and filled with fine sand complete all as specified and directed.
S&F 80 mm thick, machine pressed rubber moulded, glossy coloured, precast concrete interlocking paver block any shape and size of M-35 grade of approved shade laid over 25mm thick sand cushion and filled with fine sand complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection laid in bays not exc 1.5m with contraction joints 30x10mm filled with mixture of hot bitumen and sand, finished the surface even and smooth without using extra cement complete all as specified and directed
M&L for hard core using broken bricks of gauge not exc 63 mm, deposited, spread and levelled in layers not exc 15cm thick, water and rammed to a true surface complete all as specified and directed.
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying three coat of white wash complete all as specified and directed
M&L for preparation of new plastered surfaces of ceiling and applying three coat of white wash complete all as specified and directed
M&L for preparation of new plastered surfaces of wall and applying two coats of cement based paint over one coat of primer on wall complete all as specified and directed
S&F 15mm dia tubes medium grade galvanised, with all fitting and fixed complete to walls/ ceilings/ concealed or laid in floors complete all as specified and directed
S&F 20 mm tubes medium grade galvanised with all fitting and fixed complete to walls/ ceiling / concealed or laid in floors complete all as specified and directed
S&F for 500 Ltr capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top)in white colour triple layered, hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed
S&F 20 mm dia brass gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S&F vitreous china wash hand basin under counter type oval shape of size 550x400mm including brackets complete all as specified and directed.
S&F 15mm bore dia pillar taps cast copper alloy with capstan heads chromium plated screwed down hidh pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and directed
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed
S&F 32mm waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement complete all as specified and directed
S&F 32 mm bore Low density polyethylene pipes for Wash hand basin etc complete all as specified and directed.
S&F vitreous china urinals, half stall type (flat back), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including spreader, 60mm long brass screws, pointing around urinal back in cement; fixing with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed
S&F vitreous china sqatting pan, Orissa pattern, size 580 x 440 mm white , with integral foot rests including trap (excluding flushing cistern and flush pipe ) complete all as specified and directed
S&F PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets of capacity 10 litre ISI marked complete all as specified and directed.
S&F 20 mm dia float valve high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball screwed for iron pipe with fly nuts complete all as specified and directed.
S&F 15mm bore long body bib taps cast copper alloy chromium plated fancy type with crutch or butterfly handle sc-rewed down screwed for iron pipe or for brass ferrule complete all as specified and directed
S&F brass chromium plated shower rose 125 mm size with or without swivel joints including fixing to steel pipe or union complete all as specified and directed
S&F in repair 15 mm bore stop valves (angle type) cast copper alloy chrominum plated fancy type screwed down high presure with crutch or but terfly handle screwed both ends for iron pipe or for unions complete all as specified and directed
All as per item No 63 above but concealed type for shower complete all as specified
S&F 75mm PVC (SWR) floor trap, plain with CP grat-ing including jointing with solvent cement complete all as specified and directed
M&L for soap dish with glass tray fixed to wall with plug and chromonium plated brass screw embedded in the wall complete all as specified and directed
S&F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed
S&F CP Brass toilet paper holder of superior quality complete all as specified and directed
S&F CP Brass Jet spray with hand hold arrangement incl 1.5 m long flexible pipe with hook of superior quality complete all as specified and directed
S&F CP grating doom of 125 mm dia complete all as specified and directed
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed
S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
Dismantling of Trellis work (Jafri)/RCC jali complete all as specified and directed
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
S&F 75 mm bore PVC (SWR) bends any radius complete all as specified and directed
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed
S&F 110 mm bore PVC (SWR) junction single T, equal or unequal complete all as specified and directed
S&F 110 mm bore PVC (SWR) vent cowl complete all as specified and directed
S&F factory made PVC door frames of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube suitable for opening as per site condition complete all as specified and directed.
S&F factory made solid panel pvc door shutter 30 mm thick (style) consisting of frame made out of M. S. tubes for top & bottom rails. M. S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M. S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing
S&F steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed
S&F 200 mm long aluminum anodised barrel tower bolts of extruded section
S&F 150mm long aluminium handles, cast type, anodized complete all as specified and directed.
S&F 100 mm size butt hinges, medium weight, stainless steel complete all as specified and directed
S&F 4 mm thick Figured glass, pin head type and glazing with oil putty in squares not exc 0.5 sqm in each pane complete all as specified and directed
S&F stainless steel steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed
M&L for preparation of new or previously untreated steel surfaces of any description not otherwise described over 10 cm width or girth, and applying two coats of synthetic enamel paint over and including a coat of red oxide primer all as specified.
M&L for PCC 1:4:8 type D-2, using 40mm graded stone aggregate as in bed of drain pipe including packing under and haunching against the sides of pipes after they are laid and tested for 150mm dia of pipe complete all as specified and directed
M&L for 150 mm dia salt glzed stoneware drain pipes grade ‘A’ laid in trenches and jointed in cm 1:1 complete all as specified and directed.
M&L for 150 mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed
M&L for 300 mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed
M&L concrete bed to 300 mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 type D-2 complete all as specified and directed
S&F 450mm dia reinforced concrte pipes, class NP3, laid and jointed complete with collars complete all as specified and directed
M&L concrete bed to 450mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 type D-2 complete all as specified and directed
S&F 600mm dia reinforced concrte pipes, class NP3, laid and jointed with collars complete all as specified and directed
M&L concrete bed to 600mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 type D-2 complete all as specified and directed
M&L for precast RCC 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for man holes and drains) including necessary form work set in CM 1:4 complete all as specified and directed. (Note :- Reinforcement steel shall be measured and paid separately)
M&L for precast cover slab (for drain), of min thickness 75 mm and approved sizes of RCC grade M-25, set in CM 1:4 complete all as specified and directed.
M&L for providing precast cement concrete type B-O using 12.50 mm graded stone aggregate louvres and jallies set in CM 1:4, 35mm thick (measured solid), including all mould- ings but excluding frame complete all as specifed and as directed.
M&L for cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in foundations filling, sub base and mass concrete filling, etc complete all as specified and directed
M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in surface channel and drain complete all as specified and directed
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in copings, bed plates, plinth courses, parapets and the like including weathering, slightly rounded or chamfered angles and throating including use and waste of necessary form work etc complete all as specified and directed
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in foundation/Footing complete all as specified and directed
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed
Add or deduct for 25mm inner girth or part thereof over or under 30cm and ditto
M&L 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and as directed.
Cleaning of existing waste/soil water drain of any sizes by way of cleaning desludging foreign material manually/mechanically or pumping out waste/soil water/sludge including disposed off outside of MOD premises complete all as specified and directed
Demolition of cement concrete/bituminous mecadum surface of any description and in any position not otherwise specifically provided for complete all as specified and directed
M&L for steel work as in tubular trusses incl special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS-1161-11979 Gde St 270 complete all as specified and directed
S&F rolled mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed
S&F MS screw bolts 12mm dia (Machine Made ) with hexagonal or square heads at one end and screwedat the other end or screwed both ends,each screwed end to be fitted with washers and one end hexagonal or square nut, diameter of shank 11 to 15 mm, length of bolt not exc 5 cm long complete all as specified and directed
S&F prepainted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering,cladding to wall etc, fixed with self tapping screws complete all as specified and directed
S&F prepainted galvalume zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, fixed with self tapping screws complete all as specified and directed
Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick with 3 mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed.
All as per item No 114 here-in-before but one 3 pin, 06 Amp socket outlet point on independent board controlled by one, one way switch 06 Amp.
All as per item No 114 here-in-before but one 3 pin, 06 Amp socket outlet point on same board controlled by one, one way switch 06 Amp.
All as per Item No 114 here-in-before but point wiring with 2.5 Sq mm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 16 Amp socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
S&F switch piano flush type, 06 Amp, single pole, one way, 230 Volt complete all as specified & directed.
S&F socket outlet 2 in 1, 5 pin, 06 Amp, flush type, 230 volt complete all as specified & directed.
S&F switch socket combination outlet 2 in 1, 3 pin, 06 Amp and 16 Amp flush type, universal, 230 volt, four hole complete all as specified & directed.
S&F lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting complete all as specified & directed.
S&F single side connection LED T8 tube light rod 20 Watt, 6500K of four feet long into and including LED tube light fixture of four feet long with T8 push fit type holders, connector block, end caps, etc including connecting up complete all as specified and directed. Make : Crompton, Cat No : IGP131LT8-16& LT8-20-865-2 or Havells, Cat No : REGALBATTENT8UPT01X22WSSBS & PHOTONULTRA1213T8SSTL20WLED865SPC or philips cat no TMC 501P1XT-LED22W P 3241
S&F single side connection LED T8 tube light rod 8 Watt, 6500K of two feet long into and including LED tube light fixture of two feet long with T8 push fit type holders, connector block, end caps, etc including connecting up complete all as specified and directed.Make : Crompton, Cat No : DMLN1LT8-8& LT8-8-865-2 or equivalent in havells / philips as approved by GE.
S&F LED security light fitting 45 watt, 5700K with IP 66 protection comprises of a pressure die cast aluminium housing, heat resistance toughened glass, LED lenses, surge protector, electronic driver, etc and all accessories pre-wired including connecting up with PVC insulated copper conductor cable 1.5 Sq mm, 3 core as required for connections and 32 mm bore light grade G. I. tube mounting bracket of 1.5 metre in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete all as specified and directed. Make : Crompton, Cat No : LSTP-45-CDL or equivalent in Havells/ philips as approved by GE.
S&F ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified & directed.
S&F sheet metal enclosure distribution board, single pole and neutral, AC, 240 volt, 08 way, with 200 Amp rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
S&F MCB, SP, AC, 240 volt of 06 to 40 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
S&F in replacement of MCB, DP, AC, 240 volt of 32 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
S&F exhaust fans single phase 230/240 Volts heavy duty metalicbody of size 300 mm sweep 1400 RPM including suitable louvers and making connection with twisted copper flexibelwire 23/0.076 mm all as specified and directed. Make/Model:- Havells Turbo Force SP 1400/ Orient 300 mm Heavy Duty/ Bajaj Heavy Duty Maxx Air
Supply, laying, testing and commissioning LT underground XLPE insulated, armoured heavy duty electric cable with aluminium stranded conductor, 1100 volt grade conforming to IS-1554 and ISI marked of cross sectional area 10 Sq mm 2 core size in trenches, on wall, road crossing through protection pipe etc. complete all as specified and directed.
Providing sand cushioning with dry fine sand including filling, spreading, levelling in layers in cable trench with approved quality of sand for protection of under ground cable complete all as specified and directed
Supply and laying 40 mm bore galvanised steel tubes with all fittings, light grade laid in trenches for cable protection complete all as specified and directed
Supply and laying common burned clay bricks sub class B designation of old size bricks complete all as specified and directed
Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed.
disha construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .