Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹33.2 L+₹3.3 L (10.9%)Rejected-AOC | L2 | Rejected-AOC Rejected due to not being L1 | |
| 3 | L3₹33.3 L+₹3.3 L (11.1%)Rejected-AOC | L3 | Rejected-AOC Rejected due to not being L1 | |
| 4 | L4₹35.6 L+₹5.6 L (18.5%)Rejected-AOC | L4 | Rejected-AOC Rejected due to not being L1 | |
| 5 | L5₹41.7 L+₹11.7 L (39.1%)Rejected-AOC B 1 2 MAHESH NAGAR AMBALA CANTT 133001 HRY | AMBALA CANTT | AMBALA | HARYANA | 133001 | L5 | Rejected-AOC Rejected due to not being L1 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
15 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NORTH UDHAMPUR
GE NORTH UDHAMPUR
GE U(N)33 2023 2024REPAIRS MAINT AND CLEANING OF SEWAGE LINE SEPTIC TANK AND CONNECTED ITEMS FOR OTM MD ACCN IN PB ENCLAVE AND ADJOINING AREA UNDER AGE B R I OF GE(NORTH) UDHAMPUR
2023_MES_603999_1
GE/U(N)-33 2023-24
Open Tender
Civil Works
Item Rate
330 days
GE NORTH UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE NORTH UDHAMPUR
₹90,000
Yes
30 Aug 2023
19 Jun 2023
17 Jul 2023
19 Jun 2023
15 Jul 2023
3 Jul 2023
Amount
M & L for systematically cleaning of the water closer including nahani trap, floor trap and gully traps by bamboo/wire/kandi rotary cleaner up to first mainhole any type of dia complete all as specified and as directed by Engr-in-Charge. Note : The contractor or his authorised rep shall collect the complaint of all blockage of sewage from complaint cell /Engr-in-charge daily and all complaint will be rectified by the contractor with in same day than the returned the complaint slip after completion of complaint and get recipt from concered JE/Engr-in-charge and same will be submitted by JE/Engr-in-charge at the time of preparing payement If he fails to complete the work with in same day then recovery will be made @150.00 per complaint per day .
M & L for systematically cleaning of the sewage lines including gully traps by passing ropes, Knots, bamboo/wire/kandi rotary cleaner etc for any type of dia of sewage pipe, complete all as specified and as directed by Engr-in-Charge.
Same as item No. 4 above but 100 users capacity ( desludging n exc 12.0 cum and dewatering n exc 12 cum from each septic tank) complete all as specified.
Same as item No. 4 above but 50 users capacity ( desludging n exc 6.0 cum and dewatering n exc 6 cum from each septic tank) complete all as specified.
Same as item No. 4 above but 25 users capacity ( desludging n exc 4.0 cum and dewatering n exc 4 cum from each septic tank) complete all as specified.
M & L for excavation in trenches in hard/dense soil not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation etc or for shafts, manholes, pier holes etc n.exc 10 sqm on plan and not exc 1.50m in depth and getting out in any type of soil, complete all as specified and directed by the Engr-in-charge.
S & F HDPE DWC (Double wall corrugated) pipes confirming to IS-16098, of 150mm internal dia, presure rating SN-8 fixed with rubber seal and copler required with and including suitable bends 90/60/45 degree etc single Y junction, complete as required fixed as per manufacturer instruction laid in trenches for sewage lines all as specified and as directed. Note :- Rates included for pipe, bends any size and type, Y Jn coupler /adaptor etc required and net total length of pipe with fittings shall be measured for payment purpose.
M&L for cement concrete in 1:4:8 type D-2 (using 40 mm graded stone aggregate) in foundation bed for laying of sewage lines or mass concrete, complete all as specified and as directed by Engr-in-Charge.
M & L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed by the Engr-in-charge.
M & L for removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting pointcomplete all as specified and directed by the Engr-in-charge.
M & L for dismantling/ taking out of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches/wall upto & incl of internal dia of pipe 100/75 mm, all as specified and directed by the Engr-in-charge.
S&F 100 mm dia Cast iron Spun soil pipes, waste and vent pipes in any length with or without ears with cement joints, laid in trenches or in floors all specified and directed by the Engr-in-charge.
S&F 100 mm dia Cast iron Spun pipes, waste and vent pipes, in any length with or without ears with cement joints, fixed to wall with MS clamps all specified and directed by the Engr-in-charge.
All as per Sl. item No. 15 above but refixing only (except pipe) with stack clamp, etc, complete all as specified and as directed by Engr-in-Charge.
S&F 75 mm dia iron Spun cast pipes, waste and vent pipes, in any length with or without ears with cement joints, fixed to wall with MS clamps all specified and directed by the Engr-in-charge.
All as per Sl. item No 17 above but refixing only (except pipe) with stack clamp, etc, complete all as specified and as directed by Engr-in-Charge.
S&F in repairs CI sand cast 100mm bore bends/reducer/Tee (any radius) with access door diminishing pieces or tapers (larger bore measured) all as specified all specified and directed by the Engr-in-charge.
All as per srl item No. 19 above but 75mm bore, complete all as specified and as directed by Engr-in-Charge.
S&F in repairs CI cast 100mm bore Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches all as specified all specified and directed by the Engr-in-charge.
All as per srl item No. 21 above but 75mm bore, complete all as specified and as directed by Engr-in-Charge.
S&F 100 mm bore CI vent cowl including taking down old CI vent cowl of any type.
Ditto all as Item No. 23 above but 75mm.
M & L for cast iron eye plate with rubber washer suitabble for 75/100mm bore bends/tee, etc where required, complete all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends swan necks, etc, including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fitting and accessories).
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with MS clamps, all as specified and directed by the Engr-in-charge.
All as per Srl item No.27 above but as in refixing only with stack clamp to wall complete all as specified and as directed.
S&F110 mm bore PVC (SWR) bends with access door any radius, all as specified and directed by the Engr-in-charge.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete, all as specified and directed by the Engr-in-charge.
M&L for 15 mm thick cement plaster on the fair face of brick or concrete surface in cement mortar 1:4 finished even and smooth without using extra cement,all as specified and directed by the Engr-in-charge.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles, complete all as specified and as directed. .
M & L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 metre mean radius, using old size bricks, built in cement mortar 1:6 , complete all as specified and as directed. .
All as per item No. 33 herein before, but except bricks. Note-Old bricks obtained against dismantling shall be used.
M & L for Walling of random rubble, uncursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4 complete all as specified and as directed by the Engr-in-charge.
All as per Srl No. 35 here n before but except stone.
M & L for Flush pointing to random rubble, uncoursed on brought upto course on masonry or concrete block walling in cement mortar 1:4 complete all as specified and as directed by the Engr-in-charge.
M & L for Providing cement concrete 1:3:6 type C-1 ( Using 20 mm graded crushed stone aggregate ) as in coping, Gola etc including necessary formwork as required complete all as specified and as directed by the Engr-in-charge.
M&L for Cement concrete 1:2:4 type B-0 ( Using 12.5 mm graded crushed stone aggregate ) as in surface channel or drain including necessary form work etc, complete all as specified and as directed by the Engr-in-charge.
M & L for pre-cast RCC 1 : 2 : 4, type B-1 (using 20 mm graded stone aggregate) in cover slabs for man holes with plain faces finished fair and smooth etc, set in CM I : 6 and including necessary formwork if required incl. demolition of old slabs complete all as specified
M & L for MS TMT bars 8 mm dia and over as in reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified
Demolition of cement concrete (un reinforced) in ground floor and paving n/exe 15 cm thickness (below or above ground level) complete all as specified and as directed.
M & L for chequered vitrified tiles 30cmx30cmx10mm thick coloured with grey cement & admixtures laid over 15mm thick cement mortar 1:4 set, jointed and pointed in neat cement slurry in floors, complete all as specified and as directed.
M & L for machine pressed rubber moulded manufactured/compacted by vibrating table method pre-cast concrete interlocking paver block Laquor finish any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 grade with grey cement and pigment and joints filled with sand complete all as specified and directed.
M&L for machine pressed rubber moulded manufactured/compacted by vibrating table method pre-cast concrete interlocking paver block Laquor finish any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment and joints filled with sand complete all as specified and directed.
Dismantling and Refixing in same or ther location to make the surface smooth by filling of earth materialRefixing of interlocking tiles ofany thickness thick laid dry in position over sand cushioning including dismantling of existing tiles, complete all as specified and as directed.
M & L for Sand filling under floors or in foundations including watering and consolidation, complete all as specified and as directed.
M & L for 75mm thick PCC 1:4:8 type D1 (using 20mm graded stone aggregate) as in Sub base complete all as specified and directed.
sohtra and co
M/S PARDEEP KUMAR
SATYA SALES AND BUILDERS
anil construction co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .