Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC PULGAON | L1 | Accepted-AOC Being Lowest and Quoted rates are reasonable | |
| 2 | L2₹17.4 L+₹79,869 (4.82%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹17.8 L+₹1.2 L (7.53%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹18.8 L+₹2.2 L (13.3%)Rejected-Finance BHAWANI KRUPA GANDHI CHOWK PULGAON | PULGAON | WARDHA | MAHARASHTRA | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹18.9 L+₹2.3 L (14.1%)Rejected-Finance 40 6 UKHARA PO PRATAP PURA AGRA UP 282001 | AGRA | AGRA | UP | 282001 | L5 | Rejected-Finance Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹31,000
Closing Date
19 Jun 2024, 6:00 pmClosed
GE PULGAON
GE PULGAON CAD PULGAON PIN 442303
SPL REPAIR OF APFC PANEL AT SUB STATION 1 AND PROVN OF DEEP FREEZER / REFRIGERATOR FOR OFFRS MESS AT CAD PULGAON RESIDENTIAL AREA UNDER GE PULGAON
2024_MES_656850_1
8126/PUL/E8
Open Tender
Civil Works
Item Rate
180 days
GE PULGAON
AS PER TENDER DOCUENTS
8 documents required · 8 mandatory
₹500
GE PULGAON
₹31,000
17 Jan 2025
30 May 2024
26 Jun 2024
30 May 2024
19 Jun 2024
14 Jun 2024
31 May 2024 - 13 Jun 2024
Amount
Dismantling and taking out the existing unserviceable (damaged/broken) or serviceable tilted Panel of any type and any size, from Location and removal from site all as directed by Engr-in-Chrage.
Supply install, testing and commissioning Out door, in replacement of LT Distribution Panel Feeder Pillar (CPRI approved) Cubicle type,IP-56,outdoor type confirming to IS: 61439 Part I & II factory fabricated made out of outer cover with 3 mm thick CRCA sheet & inner cover with 2mm thick CRCA sheet of suitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate the incoming MCCB and TPN bus bars and outgoing MCCBs feeders. The TPN busbars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator at an interval of not more than 500 mm through out the length of the TPN bus bar. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. The cubicle shall have a bottom and four legs (400mm long) of size 50x 50x6 mm,
S&F Static Voltage generator 200 kvar operating on 415 Volt 3 Phase 50Hz Ac supplyand sensing from the CT installed in the 11KV indoor panel complete with IPCT for correcting the vector Rated Voltage AC 400V, Input Voltage Range AC 308~480V, Rated Frequency 50(60)Hz±10%, Redundancy Each Module is an independent reactive compensation system, Reactive Power Compensation Capability Both inductive and capacitive reactive power, Reactive Power Compensation Performance Cos??≥0.99 after compensation, Imbalance Correction Capability Mitigate negative and zero sequence, Full Response Time <20ms, Instant Response Time <100us, Thermal Loss ≤3% of SVG rated capacity, Output Current Limitation Automatic(100% rated capacity), Cooling method Intelligent forced air cooling and chamber mounted on angle iron legsimbedded in PCC (1:4:8) block type D-2( 40 mm graded agg. of suitable Size incl connection of cable with lugs of suitable size. (i) Multifunctional: Reactive power and imbalance compensation (ii) Excellent reactive compensation: High speed, Precise (-0.99≤Cosφ≤0.99), Step-less, Bi-directional (capacitive and inductance) compensation (iii) Excellent imbalance correction: Both negative and zero sequence, mitigates neutral current (iv) Wide input voltage & frequency range, adapts to tough electrical environment (v) Low thermal loss (≤3% of rated SVG capacity), efficiency ≥ 97% (vi)High stability: Infinite impedance to grid, avoids harmonic resonance problem (vii) Flexible application: Modular design, embedded in standard or customized cabinet (viii) Easy installation and maintenance: Easy installation for APF module replacement and expansion (ix) Wide capacity range: 100kvar~500kvar for a single cabinet, (x) Complete protection: Grid over/under voltage, SVG over current, over temperature, and others. All faults recorded in event log, convenient for failure analysis. (x) HMI Touch panel Display to provide all information relating to the alaram & status of the SVG as well as being capable of displaying metered values. All as specified and directed by EIC. Make : L&T/Delta/Venus technocraft
S & F in replacement of 11 kV CTs of ratio 100-50/5-5-5 class 5P10, 1&.05 S all as specified and directed by EIC.
Material and labour in replacement/repair for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 32mm X 6mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (2009) connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt alround earth plate, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) 50mm thick cover reinforced with 8mm dia TMT bars @ 100mm c/c both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm bore GI medium grade earth lead protection pipe 40mm dia, complete all as specified and directed.
Supply and fixing in replacement of galvanised iron strip 32 X 6 mm with all conecting items buried in ground for additional earthing lead all asspecified and directed by EIC.
Supply and fixing Deep Freezer, Single phase AC 230 Volts, 50 Hz (BEE certified) with star rating with double door having nominal storage capacity of 300 Ltrs
Supply, fixing, connecting and testing, automatic voltage stabilizer, wall mounted type, single phase, naturally air cooled, indoor type designed for input variation between 130 to 300 Volt and output voltage stabilised at 230 Volts with accuracy of (+) 2.5% and capacity 2 KVA complete all as specified.
SHUBHAM SALES
I P Constructions
M/S JAI BHAWANI CONSTRUCTIONS
Attar Singh and Sons
Bidder Name
Attar Singh and Sons
M/S Maa Durga Constructions,Pulgaon
M/S JAI BHAWANI CONSTRUCTIONS
SHUBHAM SALES
I P Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .