EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION
O/O THE EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION Singatala Malda PIN 732101
Setting up of BURN WARD (20 Bedded) at Vacated portion of Old Children ward at 2nd Floor of Malda Medical College and Hospital - SITC of AC Machine. (Electrical Work)
2026_WBPWD_5017568_1
WBPWD/EE/MED/e-NIQ-42/2026-27
Open Tender
Electrical Work/ Equipment
Item Rate
45 days
Malda
Please refer Tender documents.
7 documents required · 7 mandatory
₹98,000
13 Oct 2026
29 Jul 2026
31 Aug 2026
29 Jul 2026
28 Aug 2026
4 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5-year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC. | |||||
| 1.01 | Cooling Capacity- 5.2 kW (Minimum) , Air Flow Rate:600 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4-Star(min). | 2 | Nos | 10 | ₹20 |
| 1.02 | Cooling Capacity- 6.1 kW (Minimum) , Air Flow Rate:800 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4-Star(min). | 8 | Nos | 10 | ₹80 |
| 2 | Installation of Split type AC machine with necessary connection between indoor and outdoor unit by means of Copper pipe & cable including cutting hole on wall, supply & fixing of outdoor unit mounting barcket of high grade carbon steel on wall with nut, bolts etc. as required. | 10 | Items | 10 | ₹100 |
| 3Copper Refrigeration pipe line for liquid and suction line with fittings, elbows, bends, supports & brackets (Make- Totaline/ Jobu/ Nippon). | |||||
| 3.01 | Liquid Line 3/8" OD with 13 mm thick Nitrile Insulation). | 20 | Mtr | 10 | ₹200 |
| 3.02 | Liquid Line (1/4" OD with 13 mm thick Nitrile Insulation). | 70 | Mtr | 10 | ₹700 |
| 3.03 | Suction Line (5/8" OD with 19 mm thick Nitrile Insulation). | 70 | Nos | 10 | ₹700 |
| 3.04 | Suction Line (1/2" OD with 19 mm thick Nitrile Insulation). | 20 | Nos | 10 | ₹200 |
| 4 | S & F of 3 core 4.0sq.mm. of 1.1kV grade PVC insulated Copper cable for connection between indoor & outdoor units including proper termination with copper socket as required (Make: Polycab/ Finolex/ KEI). | 120 | Mtr | 10 | ₹1,200 |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
Tendernotice_2.pdf
PDF • 0.43 MB
Tendernotice_3.pdf
PDF • 2.93 MB
BOQ_5087854.xls
BOQ • 0.30 MB
CORRIGENDUM.pdf
PDF • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .