GE Satwari
GE Satwari Jammu
REPAIR MAINT OF OH ELECTRIC LINES POLES PAINTING INSULATORS TREE TRIMMING ETC AND ELECTRIC SUPPLY CABLES AND ALLIED WORKS FOR MH AREA UNDER GE SATWARI.
2022_MES_548015_1
GEJM-43/2022-23
Open Tender
Civil Works
Item Rate
270 days
Satwari Cantt
D Class Cat b i
9 documents required · 9 mandatory
₹500
GE Satwari
₹64,000
Yes
9 Feb 2023
17 Sept 2022
10 Oct 2022
17 Sept 2022
8 Oct 2022
3 Oct 2022
Amount
Dismantling and taking out steel tubular swaged pole of any size and depositing to MES store yard all as directed by Engineer -in-Charge.
Dismantling and taking out damage/rusted cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as directed by EIC
Taking out of unsv insulator any type complete all as specified
Dismantling and taking out old damaged ACSR or AAC conductor complete all as directed
Taking out serviceable/unserviceable cable aluminum conductor of any size from excavated trench/pole/over ground etc and retreived material to store kept in safe custody for reuse at site or for taking credit of cable to be replaced with new one all as specified and dirrected. Excavation, sand and return filling will be paid saperately.
Material & labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 25 sqmm 4 core all as specifed and directed.
Material & labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16 sqmm 4 core all as specifed and directed.
Material & labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16 sqmm 2 core all as specifed and directed.
Material & labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 10 sqmm 2 core all as specifed and directed.
Material & labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 150 sqmm 3.5 core all as specifed and directed.
M&L for Bus bar chamber of size 750 x 600 x 500 mm outdoor pedestal type, factory made, powder coated made out of 3.15 mm thick CRCA sheet dust and vermin proof complete with openable shutter in front and rear having proper locking arrangement, duly powder coated with 100 Amp 430 V 4 pole MCCB as incommer control and including 400 Amps, 4 pole Aluminium bus bar mounted on insulator, suitable for 3 phase, 415 volts, 50 Hz AC supply including control wiring to panel with suitable size of PVC insulated and sheathed copper cable, duly mounted on angle iron frame 50x50x6 mm including necessary PCC foundation work in all respect with phase indicator lamps (R, Y. B) – 01 Set. all as specified.
Earthing complete with galvanized steel earth plate electrode 60 cm x60cmX6 mm thick buried directly in ground to a depth not less than 3 mtr below normal ground level with top edge of earth plate at a depth not less than 2.25 mtr below ground level, earth plate surrounded by 15 cm thick packed layer of charcoal, magnicium sulphate, common salt and connected with in and including GI strip of size 25 X 4 mm by means of stainless steel bolts, nuts, check nuts and washers connected to Transformers / panels. 40mm bore of GI pipe (light grade) from earth plate up to testing point for protection of GI strip and 20 mm bore GI pipe (medium grade) with wire mesh and funnel for watering including necessary excavation and earth work, (in any type of soil) PCC chamber (1:3:6) type C-2 with RCC cover with suitable size of handle made out of 8mm dia MS bars and angle iron 40 x 40x 3mm frame for cover complete all as shown in electrical plate No 3 of MES schedule Part I of SSR Part-I 2009 complete all as specified. RCC cover shall be painted with red paint over a primer coat and the rate include in the unit rate of item.
Supply & fix thermoplastic polystyrene polycarbonate enclosures, shock proof, with IP 66 protection junction box of size 155 X 210 X 92 mm with suitable connector for three phase loop in loop out branch out and vibration proof connection and fixing on PCC or MS Electric poles using MS clamp 02 Nos made out of 25mm x 3mm MS strip and nuts & bolts of required size all as directed by Engr-in-charge. Make: Hensel Cat No. KF1616 G or its equivalent in HPL/ Sintex
M & L for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed .
Supply and fixing Danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white with letter figures and conventional skull and bones in signal red colour and fix with MS clamp for HT size 25 X 20 cm and taking out of us one complete all as specified.
Supply and fixing Danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white with letter figures and conventional skull and bones in signal red colour and fix with MS clamp for LT size 20 X 15 Cm and taking out of us one complete all as specified.
M&L Pin type, porcelain, vitreous, white, brown or green insulator, 100 mm height, 65 mm dia for 1100 volts grade including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut complete all as specified. Make -PACTIL / MADRAS PORCELAIN / NGEF / JAIPURIA / BHEL .
M&L loop type, porcelain, vitreous, white, brown or green insulator small size 65 X 90 mm, clearance of hole 16 mm mm for 1100 volts grade including out of U/S one complete all as specified. Make -PACTIL/ MADRAS PORCELAIN / NGEF / JAIPURIA / BHEL .
M & L for Restretching of LT over head line ACSR conductor on steel/PCC pole comprising of any size of conductor aluminium/copper/GI after opening binding wire from insulators and replace binding wire and achieved permissible sag limit of over head line conductor complete all as directed and specified.
M&L for P G clamp of size 4 to 7 mm dia consisting of two brass plates and two steel bolts and nuts for two conductor of equal or unequal sizes for non tension connections including treatment of connector and ACSR conductor with conducting jelly, fixed in repairs complete.
M&L for P G clamp of size 10 to 13 mm dia consisting of two brass plates and two steel bolts and nuts for two conductor of equal or unequal sizes for non tension connections including treatment of connector and ACSR conductor with conducting jelly, fixed in repairs complete.
M&L fluoresent Retro-reflective sheet of size not less than 50 mm width high grade quality of yellow/Red colour fixed on pole after cleaning and removing paint of existing surface complete all as specified and directed.
M & L for Painting of steel tubular/ rail pole with cross arms, clamp of any length and shape for LT overhead line with single coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 20 cm dia black circle with white colour numbering with synthetic enamelled paint from bottom of pole to 90 cm height an complete all as specified and directed.
Supply, stringing and fixing of aluminium conductor steel reinforced ( ACSR) of any type including binding with and including suitable size of binding wire complete Including dismantling and taking out warn out ACSR conductor from overhead electric line comlete all as directed.
Ditto all as per item No. 24 but GI wire 4 mm dia complete.
Supply and fixing mild steel galvanised stay assembly set complete comprising of 14 mm dia, 400 mm long stay bow, 2150mm long stay rod 20mm dia, 300mm x 300mm x 6mm stay plate, thimble, all as shown in electrical plate No.1 of MES Schedule part-I 2010 complete including dismantling and taking out old damaged stay complete all as directed.Note :- PCC , earth work and Insulators etc shall be measured and paid separately.
Cutting & trimming tree branches along HT /LT over head lines after taking all precautions while working on lines such as taking shut down, safety of equipments etc and treaming of tree branches n.exc 3 mtr long and clearing of area and removing the same from site to a distance not exceeding 50 mtr complete all as specified and directed. NOTE: Grith of tree branches shall be measured only above 50 mm dia .
M&L for Synthetic insulating rubber mat of size 2 m x 1 m x 3 mm as per IS 15652-2006 for voltage upto 33 KV complete all as specified and directed by EIC.
M&L for painting of XPM fencing, chanels, post etc mounted on plinth (external and internal both side) with one coat of silver aluminium paint, complete all as specified and directed.
Material & labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate in foundation and mass concrete/filling, complete all as specified and directed.
M & L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed .
Material & labour for PCC 1:2:4 type B-1 using 20mm graded stone aggregate in coping and the like including weathering slightly rounded/chamfered angles with & incuding necessary use and waste of form work for fair faces of concrete, complete all as specified and directed.
Supply and fixing steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-31 (9 meter long) complete all as directed . Note - Earth work and PCC shall be measured and paid separately as these respectively.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cables & foundation of poles ,stay assembly and getting out in any type of soil complete all as specified and directed .
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
Supply and spreading sand Dry cushioning to cable providing with a layer of sand 8cm deep before laying the cable and 15cm deep after laying and stretching the cable in trenches complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid.
Servicing / routine maintenance of ACB in AMF panel for 500 KVA DG set Make: C&S Model AH-8D-CS of capacity 800 Amp checking of fastener,checking of shock absorber for leakage,checking of top and bottom trip free mechanisam,closing and tripping spring assy & spit pin, spring cut off micro switches., earth fault relays, under voltage relays all as specifed. Note: Replacement of any spare part will be measured and paid separately under relevent item.
Servicing / routine maintenance of ACB in AMF panel for 625 KVA DG set Make: C&S, Model AH-8D-CS of capacity 1000 Amp checking of fastener,checking of shock absorber for leakage,checking of top and bottom trip free mechanisam,closing and tripping spring assy & spit pin,spring cut off micro switches., earth fault relays , under voltage relays all as specified. Note: Replacement of any spare part will be measured and paid separately under relevent item.
Supply and fixing of Charging motors 220 V AC
Supply and fixing Earth fault relay for 6D-16D/08N-20S
Supply and fixing Closing coil (6D-16D/08N-206(AHA)
Supply and fixing Shunt Trip 6D-16/08N-20S(AHA) C&S
Supply and fixing Single phase polyester resin cast CTs for '' AH/AHA'' ACB for thermal release 8D/08N(AHA) 800/5A
Supply and fixing Compact UVT Coil 6D-16D/08N-20S(AHA)
Supply and fixing Auxiliary switch of type 14 way (7NO+7NC) 6D-16D/08N-20S(AHA)
Supply and fixing main moving contacts Assembly
Material and labour in replacement of GATE TOP LIGHT MONACO decorative LED 3000K 10W fixture, aluminium die casting, transperent glass diffuser, black colour IP-43 complete inluding fixing using metal sleeve anchor fastners and bolts of suitable size and quantity to be fixed in concrete all as specified.
Material and labour in replacement of POLE LIGHT MONACO decorative LED 3000K 20W fixture, aluminium die casting, transperent glass diffuser, black colour IP-43 complete inluding fixing using metal sleeve anchor fastners and bolts of suitable size and quantity to be fixed in PCC block of size 45x45x60cm all as specified. Note : Rate of PCC will be inclusive in the quoted rates and nothing extra will be admission on this account.
S&F sub main wiring with single core cable 2 x 4 sq mm FRLS insulated Unsheathed stranded copper conductor cable 1100 Volts grade in rigid PVC conduit (Concealed) medium grade alongwith 1 x 4 Sq mm FRLS insulated unheathed copper conductor cable as earth wire connected with main earth dolly including chiseling, cutting & making good to match with the existing surface complete all as specified and directed.
S&F 1100 volt grade heavy duty cable PVC insulated multistranded aluminum conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4 mm dia GI suspension wire one twin core cable flat or circular of size 16 Sqmm two core incl taking down old service connection and removing from the side complete all as specified and as directed.
Taking out old bricks from excavated trenches, full bricks to be kept in safe custody for reuse at site. Broken bricks shall be removed by contractor at no extra cost to low lying area.
Relaying of healthy cable of any size retrived from srl item No 5 above after repair, making proper jointing and making connection using thimbles/lugs of suitable size as required at site.
Dismantling PCC all as dirrected and making good surface.
Steel tubing galvanized (light grade) 100 mm bore conforming to IS-1239 for passing cable under road/floor or fixing to poles for protection of under ground cable complete with Flat iron 50x6mm clampsmade to shape and 12mm dia bolts, nuts and washers for fixing where required complete all as directed by Engr-in-Charge.
Steel tubing galvanized (light grade) 80 mm bore conforming to IS-1239 for passing cable under road/floor or fixing to poles for protection of under ground cable complete with Flat iron 50x6mm clampsmade to shape and 12mm dia bolts, nuts and washers for fixing where required complete all as directed by Engr-in-Charge.
Steel tubing galvanized (light grade) 50 mm bore conforming to IS-1239 for passing cable under road/floor or fixing to poles for protection of under ground cable complete with Flat iron 50x6mm clampsmade to shape and 12mm dia bolts, nuts and washers for fixing where required complete all as directed by Engr-in-Charge.
Steel tubing galvanized (light grade) 40 mm bore conforming to IS-1239 for passing cable under road/floor or fixing to poles for protection of under ground cable complete with Flat iron 50x6mm clamps made to shape and 12mm dia bolts, nuts and washers for fixing where required complete all as directed by Engr-in-Charge.
Re-laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid.
Supply, laying in replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable PVC insulated & PVC outer sheathing with aluminium conductor, Armoured conforming to IS-7098 Part-I (1988) with latest ammendments of size 25 Sqmm x 3.5 core. Note:- Earthwork/excavation shall be measured seperately
Description all as per srl item No 61 here in before but of size 35 Sqmm x 3.5core
Description all as per srl item No 61 here in before but of size 50 Sqmm x 3.5core
Description all as per srl item No 61 here in before but of size 70 Sqmm x 3.5core
Description all as per srl item No 61 here in before but of size 95 Sqmm x 3.5core
Description all as per srl item No 61 here in before but of size 120 Sqmm x 3.5core
Description all as per srl item No 61 here in before but of size 185 Sqmm x 3.5core
Description all as per srl item No 61 here in before but of size 240 Sqmm x 3.5core
Description all as per srl item No 61 here in before but of size 300 Sqmm x 3.5core
SATISH AND CO
M/S S K Electricals Regd
Harsh Electricals
M/S ZTECH
BMMJ TRADERS AND ENGINEERS
M/S SHREE KRISHANA ENERPRISES
CELMAC REGD
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .