Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹33.6 L+₹4.6 L (16.0%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹36.8 L+₹7.9 L (27.2%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹37.9 L+₹9.0 L (30.9%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Other than Lowest |
Tender Value
₹41.7 L
EMD Value
₹83,380
Closing Date
17 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
MISC REPAIR TO AC PLANTS OF SIGNAL CENTRE HQ CAMS DGIS AND VARIOUS OTHER LOCATIONS UNDER GE (U) PM DELHI CANTT10
2023_MES_619574_1
GE(U)/PM/D-41/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
DELHI CANTT-10
MES contractor enlisted under class D category a (i) b (i) having deposited standing security of Rs 100000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class a
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹83,380
Yes
18 Dec 2023
19 Sept 2023
19 Oct 2023
19 Sept 2023
17 Oct 2023
3 Oct 2023
Amount
Demolition of brick work built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and as directed
Material and labour brick work with fly ash bricks, straight or curved on plan exc 6M mean radius, old size brick built in cement mortar 1:6 complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc including ranking out joints hacking for key scrubbing down with water etc but lime plaster any description complete all as specified and as directed
Material and labour for rendering 15mm thick on fair faces of brick work in CM1:6,finished even and smooth without using extra cement complete all as specified and directed
Material and labour for applying two coats of oil bound distemper over a coat of primer on walls including preparation of new plastered surface complete all as specified and directed. Make for paint & Primer :- Asian / Berger / Jenson & Nicholson / Shalimar.
Material and labour for rendering 15mm thick on other than fair faces of brick work in CM1:6,finished even and smooth without using extra cement complete all as specified and as directed
Material and labour for Preparing and applying two coats of cement base paint on new Plasterd surface of wall omplete all as specified and as directed. Make for paint & Primer :- Asian / Berger / Jenson & Nicholson / Shalimar.
Material and labour for Rendering 10mm thick on concrete surfaces of ceiling in CM 1:4 complete all as specified and as directed
Material and labour for 2 coats of white wash on ceiling surface including preparation of newly plastered surfaces complete all as specified and as directed.
Dismantling floor, hearth wall tiling etc including cement mortar bedding (but not backing)/ cement plaster including rubbish off the premises complete all as specified and as directed
Material and labour for non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc laid over 15mm thick screed bed in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. Make :- Somany/ Johnson/ Kajaria/ Asian/ Nitco
Material and labour for glazed ceramic coloured tiles of size 450X 350X 7mm thick over 10mm thick plaster in CM 1:4 on vertical surfaces such as skirting, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and drected. Make :- Somany/ Johnson/ Kajaria/ Asian/ Nitco
Material and labour for 18-20 mm thick machine cut kota stone slab flooring over 20 mm thick screed bed in cement mortar (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed
Demolition of cement Concrete in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and directed
Demolition of reinforcement cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed
Material and labour for precast reinforced cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in cover in drain, manhole cover, plateform etc all as specified and directed.
Material and labour for RCC 1:1½ :3 type A1(using 20 mm graded stone aggregate) as in foundations, footings, plinth beams; bases for columns, etc. Complete all as specified and directed
Material and labour for RCC 1:1½ :3 type A1(using 20 mm graded stone aggregate) as in Column, pillars, piers, posts and struts etc complete all as specified and directed
Material and labour for formwork to sides of concrete in foundations, footings, bases of columns, sides and soffits (if any) plinth beams, and similar work complete all as specified and directed
Material and labour for formwork to sides of concrete of pillars, posts, struts, piers, columns etc complete all as specified and directed
Material and labour for TMT bars 6 to 8 mm dia for reinforcement cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, and binding with and incl MS wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-415 or Fe-500 complete all as specified and directed.
Material and labour for 25mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in floor sub base comoplete all as specified and directed
Material and labour for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in copings, bed plates, plinth courses, parapets and the like including weathering, slightly rounded or chamfered angles and throating including use and waste of necessary form work etc complete all as specified
Material and labour for 75 mm thick PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
Taking down door/window/ventilator frames with shutters not exc 1.50 sqm each (without taking off shutters from frame) all as specified.
Taking down door/window frames with shutters exc 1.50 sqm but not exc 4.00 sqm each (without taking off shutters from frame) all as specified.
Taking down shutters of any description exceeding 1.00 Sqm but not exceeding 2.00 Sqm each.
Supply and fixing powder coated aluminium frame for doors, windows, ventilators and sliding tracks, beading for grill with one or more rebates including joining cleat for fixing etc. complete all as specified and directed (min thickness of powder coating 50 micron).all as specified. Make of aluminium section:- Hindalco/ Indal/ Jindal
Supply and fixing anodised aluminium door/window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed. Make of aluminium section :- Hindalco/ Indal/ Jindal
Supply and fixing Safety lever locks mild steel with 4 levers and ball bearings for rolling shutters complete all as specified and as directed.
Supply and fixing in repair 140 mm floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring complete all as specified and directed
Surface excavation n exc 30cm deep and averaging 15cm deep in soft/ loose soil complete all as specified and as directed.
Material and labour Hard core of Broken bricks of gauge n.exc 63mm deposited spread & levelled in layers n exc 15cm watered and rammed to a true surface complete all as specified and as directed.
Material and labour for cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations filling, sub base and mass concrete filling, etc complete all as specified and directed
S&F 80 mm thick, machine pressed rubber moulded, glossy coloured, precast conctete interlocking paver block any shape and size of M-40 grade of approved shade laid over 50mm thick sand cushion and filled with fine sand complete all as specified and directed. Make:- M/s Ultra Tiles/ Nitco/Pavit/ Sunshine Industries (Shino tiles)
Material and labour for preparation of old decorated plastered or un-plastered surface of walls, cornices, pilasters etc by brooming down scraping, filling all the nail holes etc and prepairing surface with plaster of paris etc and applying two coat of white wash on walls mixed with adequate qty of fevicol complete all as specified and directed.
Description all as per Item No 36 above but on ceiling complete all as specified and as directed.
Material and labour for preparation of old decorated plastered or un-plastered surface of walls, cornices, pilasters etc by brooming down scraping, and applying two coat of cement base paint on walls tinted or white complete all as specified and directed. Make for paint :- Snowcem / Asian/ Berger/ Dulex
Material and labour for preparation of old painted wooden surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. Make for paint & Primer :- Asian / Berger / Jenson & Nicholson / Shalimar.
Description all as per item No 39 here-in before but on steel surfaces complete all as specified and as directed. Make for paint & Primer :- Asian / Berger / Jenson & Nicholson / Shalimar.
Supply only moulded case circuit breakers(MCCB) 250 Amps, adjustible type, 4 Pole, 36 kA, thermal magnetic with rotary handle and spreader compete all as specified and as directed. Make- Legrand/L&T/ABB/Schneider/Seimens
Supply only moulded case circuit breakers(MCCB) 125 Amps, adjustible type, 4 Pole, 36 kA, thermal magnetic with rotary handle and spreader compete all as specified and as directed. Make- Legrand/L&T/ABB/Schneider/Seimens
Supply only moulded case circuit breakers(MCCB) 100 Amps, adjustible type, 4 Pole, thermal magnetic with rotary handle and spreader compete all as specified and as directed. Make- Legrand/L&T/ABB/Schneider/Seimens
Supply only miniature circuit breaker (MCB) 63 Amps, 4 Pole, 25 KA compete all as specified and as directed. Make- Legrand/L&T/ABB/Schneider/Seimens
Supply only miniature circuit breaker (MCB) 32 Amps, 4 Pole, 25 KA compete all as specified and as directed. Make- Legrand/L&T/ABB/Schneider/Seimens
Supply only control 'C' curve miniature circuit breaker (MCB) 6 Amps, single pole (SP), 10 KA compete all as specified and as directed. Make- Legrand/L&T/ABB/Schneider/Seimens
Supply only power contactor, 40 Amps triple pole (TP), AC 3 duty(main & delta), compete all as specified and as directed. Make- L&T or equivalent in ABB/Legrand
Supply only power contactor, 32Amps triple pole (TP), AC 3 duty (STAR), compete all as specified and as directed. Make- L&T or equivalent in ABB/Legrand
Supply only power contactor, 25 Amps triple pole (TP), AC 3 duty, compete all as specified and as directed. Make- L&T or equivalent in ABB/Legrand
Supply only power contactor, 18 Amps triple pole (TP), AC 3 duty, with add on block, compete all as specified and as directed. Make- L&T or equivalent in ABB/Legrand
Supply only power contactor, 12 Amps triple pole (TP), AC 3 duty, with add on block, compete all as specified and as directed. Make- L&T or equivalent in ABB/Legrand
Supply only power contactor, 9 Amps triple pole (TP), AC 3 duty, with add on block, compete all as specified and as directed. Make- L&T or equivalent in ABB/Legrand
Supply only auxillary contactor (add-on block), suitable for 25-40 amps power contactors, compete all as specified and as directed. Make- L&T or equivalent in ABB/Legrand
Supply only overload relay 30-50 amps,compete all as specified and as directed. Make- L&T/Siemens/Legrand/ABB/C&S
Supply only overload relay 14-23 amps,compete all as specified and as directed. Make- L&T/Siemens/Legrand/ABB/C&S
Supply only overload relay 9-15 amps,compete all as specified and as directed. Make- L&T/Siemens/Legrand/ABB/C&S
Supply only overload relay 4.5-7.5 amps,compete all as specified and as directed. Make- L&T/Siemens/Legrand/ABB/C&S
Supply only star/delta timer range 3-30 seconds,suitable for LT panels compete all as specified and as directed. Make- L&T/ABB/Legrand
Supply only solid state single phasing preventer type VSP2 compete all as specified and as directed. (Make:- Minilec/ L&T/ Siemens/Legrand/ ABB/ C & S.)
Supply only solid state single phasing preventer type VSP3 compete all as specified and as directed. (Make:- Minilec/ L&T/ Siemens/Legrand/ ABB/ C & S.)
Supply only Trip neutral closed (TNC) switch suitable for 200-630 Amps rating MCCB's/ACB's compete all as specified and as directed. Make- Salzer
Supply only Phase indication lights of suitable colour, 240V AC suitable for mounting on LT panel, compete all as specified and as directed. Make:- ESBEE
Supply only on/off/trip indication lights of suitable colour, 240V AC, suitable for mounting on LT panel compete all as specified and as directed. Make:- ESBEE
Supply only on/off push buttons suitable for mounting on LT panels, compete all as specified and as directed. Make:- ESBEE
Supply only copper neutral link suitable for LT panel and as per site requirement, compete all as specified and as directed. Make :- L&T or equivalent in ABB/Legrand/AE
Material and labour in replacement Direct-on-Line Starter in steel sheet enclosure type, motor rating AC-3 Duty, 415 V, 3-Phase, relay maximum range 13-22 Amp, MK1 DOL suitable for 2 HP to 5 HP pump sets complete all as specified and directed. Make :- L&T or equivalent in ABB/Legrand
Material & labour for earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron strip of size 32x6 mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @150 c/c both ways, one lifting handle made of 10mm dia TMT bar embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15cm thick including testing on completion all as specified and as directed. (Note:- Each protection pipe and earth lead upto and including 7.50m length is deemed to be included in unit rate of of this item.)
Supply & fixing of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drewn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.as required 32x6 mm galvanised iron strip including taking down old unserviceable one complete all as specified & as directed.
Material and labour for sub main wiring with two runs of single core 1.5 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded, unsheathed 1100 volts grade in PVC casing caping (medium grade) of adequit size with all fittings and accessories surface type including one run 1.5 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694) as earth wire, including taking down old unserviceable one of any type and any size ( including wooden batten, PVC conduit or casing caping), compete all as specified and as directed. (Make of Cable : HAVELLS/ POLYCAB/FINOLEX/RR Cable/KEI Industries Ltd). (Make of PVC Casing Caping :PRESTOPLAST/ FINOLEX/ Payal/Kalinga)
Material and labour for sub main wiring with two runs of single core 2.5 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded, unsheathed 1100 volts grade in PVC PVC casing caping (medium grade) of adequit size with all fittings and accessories surface type including one run 2.5 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694) 2.5 Sqmm as earth wire, including taking down old unserviceable one of any type and any size ( including wooden batten, PVC conduit or casing caping), compete all as specified and as directed. (Make of Cable : HAVELLS/ POLYCAB/FINOLEX/RR Cable/KEI Industries Ltd). (Make of PVC Casing Caping :PRESTOPLAST/ FINOLEX/ Payal/Kalinga) {Note for item No. 75 & 76:- (i) Two runs of cable with one run earth wire and PVC casing caping shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the casing caping. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.}
Supply and fixing in replacement fully automatic star delta starter for 3 Phase, 415V, 20 HP rating induction motor for cooling tower containing electric over current protection relay range 13-- 19.5Amp with external CT 960 Amp, AC-3, 25 Amp contactor rating and back up protection HRC fuse of suitable rating etc complete all as specified and as directed. Make - L&T/Siemens/Legrand/ABB/Crompton
Supply laying, connecting and testing in replacement GI water tubing 50 mm bore, medium grade, with all fittings, with screwed and socketed joints, laid in floor or fixed to wall or surface and making good the disturbed surface complete all as specified and as directed. Make:- Jindal/Tata/BST/Prakash
All as per Srl item No. 78 here-in-before but 25 mm bore complete all as specified and as directed.
All as per Srl item No. 78 here-in-before but 20 mm bore complete all as specified and as directed.
All as per Srl item No. 78 here-in-before but 15 mm bore complete all as specified and as directed.
Taking down existing water storage tank and S&F rotational moulded polyethylene multilayer water storage tank of capacity 1000 litre (cylindrical vertical with closed top) hoisted and fixed in position on existing wall, stage, roof or RCC staging including complete connection of inlet and out let pipe, tank nipple, float valve etc. fixing of GI pipe (over flow) & washout pipe to the nearest rain water drain complete all as specified and as directed. Make:- Sintex/Polycon/Rotex
Material and labour sub main wiring with 2 runs of 6.0 Sqmm single core, PVC insulated & unsheathed, FRLS cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 6.0 Sqmm size PVC insulated copper conductor including taking down old sub main wiring complete all as specified and directed. (Make of Cable : HAVELLS/ POLYCAB/FINOLEX/RR Cable/KEI Industries Ltd). (Make of PVC Casing Caping :PRESTOPLAST/ FINOLEX/ Payal/Kalinga) {Note :- (i) Two runs of cable with one run earth wire and PVC casing caping shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the casing caping. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.}
S & F in replacement Gun metal Ball valve suitable for 50 mm bore pipe complete all as specified and as directed. Make :- Zoloto/Kirloskar/Leader.
All as per Srl item No. 84 here-in-before but suitable for 40 mm bore pipe complete all as specified and as directed.
All as per Srl item No. 84 here-in-before but suitable for 25 mm bore pipe complete all as specified and as directed.
All as per Srl item No. 84 here-in-before but suitable for 20 mm bore pipe complete all as specified and as directed.
All as per Srl item No. 84 here-in-before but suitable for 15 mm bore pipe complete all as specified and as directed.
Supply, laying replacement of connecting XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables, heavy duty, 1100 Volts grade with standard aluminium conductor of size 16 Sqmm, 4 core complete all as specified and as directed. Make:- Polycab/Finolex/Fort Gloster/KEI Industries Ltd/Havells.
Supply and fixing in repairs / replacement Compound pressure gauge (Discharge pressure) of size 100 mm dia suitable for 0 to 300 PSI with suitable housing for mounting on pipe complete all as specified and as directed. Make :- Adarsh / Fiebig
Supply and fixing in repairs/replacement Compound suction and Oil pressure gauge of size 100 mm dia suitable for 0 to 150 PSI with suitable housing for mounting on pipe complete all as specified and as directed. Make :- Adarsh / Fiebig
Material and labour in replacement PTMT float valve with EPOXY coated Aluminum rod and HD Ball suitable for 20mm bore pipe complete all as specified and directed. Make:- Prayag / Polytuff / Supreme.
S&F prefabricated MS cage for water storage tank made out of MS Angle iron frame of size 35mm x 35mm x 5mm in cubical shape welded with wire mesh of 2 mm dia on five side having opening arrangement, nut bolts of any size and shape 01 Nos (Approx weight 90 Kg each) including hoisting and fixing of protection cage over existing service tank of capacity 1000 Litre at roof level, duly painted with two coat of synthetic enameled paint over and including a coat of red oxide primer including grouting in PCC 1: 3: 6 complete all as specified and directed. Make for paint & Primer :- Asian / Berger / Jenson & Nicholson / Shalimar.
Material and labour for servicing of Floor mounted AHU unit of 12000 CFM to 17000CFM capacity including cleaning of bottom tray and painting inside the tray with one coat of marine anti-corrosive paint over a coat of red oxide primer, cleaning of cooling coil and filters complete with high pressure detergent solution without damaging cooling coils, checking aligning and tightening of blower fan, greasing of all movable parts, replacement of worn out bolts, nuts shaft keys etc complete all as specified and as directed. Make for paint & Primer :- Asian / Berger / Jenson & Nicholson / Shalimar.
ditto- all as per item No. 94 above but 5000 CFM to 10000CFM capacity
Material and labour for servicing of ceiling mounted AHU unit of 1500CFM to 5000CFM capacity including cleaning of bottom tray and painting inside the tray with one coat of marine anti-corrosive paint over a coat of red oxide primer, cleaning of cooling coil and filters complete with high pressure detergent solution without damaging cooling coils and ceiling, checking aligning and tightening of blower fan, greasing of all movable parts, replacement of worn out bolts, nuts shaft keys etc complete all as specified and as directed. Make for paint & Primer :- Asian / Berger / Jenson & Nicholson / Shalimar.
Material and labour for servicing of package type AHU unit of up to 5000CFM capacity including cleaning of bottom tray and painting inside the tray with one coat of marine anti-corrosive paint over a coat of red oxide primer, cleaning of cooling coil and filters complete with high pressure detergent solution without damaging cooling coils and ceiling, checking aligning and tightening of blower fan, greasing of all movable parts, replacement of worn out bolts, nuts shaft keys etc complete all as specified and as directed. Make for paint & Primer :- Asian / Berger / Jenson & Nicholson / Shalimar.
Disconnecting from mains/taking out existing unserviceable/defective Cooling tower motor of capacity 20 HP of any size, type, and make including disconnecting all electrical connections removing from foundation transporting to repair workshop disconnecting unserviceable burn out winding completely including insulating materials and rewinding of the complete stator with super enameled copper wire of existing size applying proper insulation ‘F’ class varnish drying in oven, assembling, transporting back to site, re-installating, testing and commissioning complete all as specified and as directed.
Supply only three phase Over load thermal relay direct mounting type, relay range 23-30 Amps, including necessary wiring, thimbles, etc complete all as specified and as directed. Make- L&T/Siemens/Legrand/ABB/C&S
Supply only three phase Over load thermal relay direct mounting type, relay range 20-33 Amps, including necessary wiring, thimbles, etc complete all as specified and as directed. Make- L&T/Siemens/Legrand/ABB/C&S
Material and labour for preparation of surfaces of Central AC Plant of capacity 2x 24/25 TR , trap door, condensers,chillers,compresors, Induction motors, pumps, hot water boiler, C channels, all pipe lines, valves and outer body of cooling towers and AHU's with different colors following the color code system as directed by the site-in-charge.Job includes removing the old paint by rubbing, brushing and applying one coat of red oxide zinc chrome primer and two coats of Synthetic Enamel Paint (1st grade quality) complete all as specified and as directed. Make for paint & Primer :- Asian / Berger / Jenson & Nicholson / Shalimar.
diitto- all as per item No. 101 above but Capacity of AC Plant 3x 60 TR
diitto- all as per item No. 101 above but Capacity of AC Plant 3x 30 TR
diitto- all as per item No. 101 above but Capacity of AC Plant 3x 15 TR
Supply and fixing in repairs / replacement thermometer suitable for condenser water line with suitable housing for mounting on pipe line 0-50°C complete all as specified and as directed. Make :- Indfoss / Renutrol
Material and labour for 100 mm thick cement concrete type C-2, 1:3:6 ( 40 mm graded aggregate) including finishing surface of concrete topping even and fair ( without using extra cement), and finishing surface of concrete in floors including taking down complete all as specified & as directed.
Material and labour for taking out old MS pipes and Supplying & laying , testing & commissioning mild steel (Heavy) 'C' class pipe of size 250 mm dia on exposed surface / underground (in trenches) including welding works, connections with existing chiller/condenser water line, chiller/condenser pump, fabrication of bends, MS flange, tees, reducers, shoe, support ( brick masonry block & wooden support for underground / MS angle- clamp & wooden support for exposed surface ) along with priming coat of steel primer as per standard specification complete all as specified & as directed. Make for ms pipe :- Tata/Jindal/Sail/Oswal. Make for paint & Primer :- Asian / Berger / Jenson & Nicholson / Shalimar. Note:- (i) The rates quoted by the contractor shall deemed to include the cost of MS fittings required during laying of MS Pipes. (ii) The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be heavy class of thickness min. 7mm as per IS: 3589
ditto- all as per item no 107 above but size 100 mm dia
ditto- all as per item no 107 above but size 80 mm dia
ditto- all as per item no 107 above but size 50 mm dia
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation / fixing pole / laying cable and pipe line etc or for man hole etc not exc 10 Sqm on plan and getting out in soft / loose soil complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick complete all as specified and as directed.
Removing excavated Soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Disconnecting of electrical connection from panal board and Taking out electric motor pump of capacity 40 HP from the base plate of pump set after opening the nut bolts and transporting the motor to workshop and after repairing the motor, re-installing & testing complete all as specified and as directed.
Opening the electric induction motor of capacity 40 HP and taking out the unserviceable winding wire complete and cleaning the slots, rewinding the motor with super enamelled copper winding wire of gauge same as existing gauge including all other insulating material, (i.e. cotton tap, PVC tap, PVC sleeve glass pipe, varnish) complete all as specified and as directed.
Disconnecting the centrifugal pump and repairing the same by replacing unserviceable spare parts including lath work etc and re-assembling the same in original position of 40 HP pump having discharge 25 LPS at 65 Mtr head complete all as specified and as directed. (Note:- Spare parts required for repaired shall be measured and paid separately under relevant item of this schedule)
Supply only in replacement following spare for pumps of capacity 40 HP, complete all as specified and as directed. Make-Kirloskar or equivalent in crompton Greaves
CI Impellor
CI casing wearing ring DEN/ ND.
CI Split glands.
Ball bearing SKF 6306/6307.
Bearing Cap.
Key for impeller steel.
Impeller nut (steel).
Remetalling welding & turning of pump shaft.
Stuffing box bush.
Gland packing
Trey coupling
Supply and fixing in replacement CI foot valve suitable for 100 mm bore pipe flange type including nut, bolts & washers etc complete all as specified and directed. Make:- Advance / Audco / Leader / Castel / NVR / Zoloto.
Supply and fixing in replacement cast Iron non return valve suitable for 80 mm bore pipe flange type including nut, bolts & washers complete all as specified and as directed. Make:- Advance / Audco / Leader / Castel / NVR / Zoloto.
Material and labour for dewatering and cleaning of underground sumps of 10000ltr to 25000ltr capacities with high pressure water jet to remove all masses, algae and dirt and removal of dirty water along with sludge using sludge machine and disposal of the same to a safe distance and including scrubbing of internal surfaces using industrial vacuum machine and applying of anti bacterial sterilization spray and apply one coat white wash to walls, floors and ceilings internal surfaces of reservoirs and UG sumps of the following capacity complete all as specified as directed .
Material and labour preparation of surface by removing old paint by scraping with scrap paper/ sand paper and applying two coat of synthetic enamel paint on pipe lines (100/80mm- approx 80mtr), sluice valves & NRV (80mm size- 11 Nos) , Pumping sets with base ( 40HP capacity- 04Nos), 200/250mm size header-20mtr etc including writing letters SM/MES No. on pumping set with letter size of 10 cm Hight complete all as specified and as directed.
Supply only in replacement rubber insulating mat class A type, chequered, size 2 Mtr x 1 mtr x 25 mm thickness, for working voltage 3.3 KV complete all as specified and as directed. Make : Jyoti /Dunlop or Equivalent
Material and labour in replacement cast iron body sluice valve, stainless steel stem, non raising wedged gates with iron wheel head, PN-1.6, as per IS-14846, including flanged joints suitable for 80 mm bore pipe complete all as specified and directed. Make:- Advance / Audco / Leader / Castel / NVR / Zoloto.
diitto- all as per item No. 123 above but dia 100mm
diitto- all as per item No.123 above but dia 150mm
Supply and fixing in repairs DOL starters for motors of 7.5 HP capacity with suitable rating relay, suitable for mounting on existing LT Panels of AC plants and connections with suitable size single core copper conductor wire compete all as specified and as directed. (Make -L&T/Siemens/Legrand/ ABB/Crompton.)
Supply only PVC insulated single core copper conductor cable of size 16 sqmm for connections in LT Panels to centrifugal pump sets, complete all as specified and as directed. Make:- Finolex/Polycab/KEI/Havells
Dismentling the defective FRP cooling tower gear box of Cap 220/230 TR of Make- Paharpur, and Overhauling the same by replacing defective broken/unserviceable spare parts taper/ ball bearings, any type gears, main shaft kharad work, keys, nut bolt etc and including gear oil, greasing , servicing, cleaning and assembling, testing & commissioning for satisfactory performance complete all as specified & as directed.
Supply only gear oil suitable for gear box of Cap 220/230 TR cooling tower
Supply and fixing in replacement/repair fan blades for FRP Cooling tower of Cap- 220/230TR with complete fitting nut, bolt etc. complete all as per specified and directed.
P S TRADERS
SREE BABA TRADERS
J.P. Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .