Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance KASIMPUR RAMASHANKAR YADAV 165 35 TYPE SECOND NEW COLONY KASIMPUR ALIGARH UTTAR PRADESH 202127 | ALIGARH | UTTAR PRADESH | 202127 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹10.9 L
EMD Value
₹21,800
Closing Date
5 Aug 2021, 2:00 pmClosed
Er Sunil Kumar SE OMC-II DTPS Kasimpur Aligarh
Office of the SE OMC-II DTPS Kasimpur Aligarh Mobile No 9415900792
Routine Preventive and Breakdowns maintenance of turbine associated auxiliaries including all coolers various pumps and valves of turbine side of Unit 7 1x120MW Kasimpur Aligarh
2021_RVUNL_600814_1
ET-11/OMC-II/TMD/21-22
Open Tender
Repair and Maintenance Works
Fixed-rate
365 days
Office of the SE OMC-II DTPS Kasimpur Aligarh
As per Tender Documents
4 documents required · 4 mandatory
₹1,180
SAO CFA and BO HTPS KASIMPUR ALIGARH
₹21,800
28 Aug 2021
2 Jul 2021
7 Aug 2021
2 Jul 2021
5 Aug 2021
2 Jul 2021
2 Jul 2021 - 5 Aug 2021
Amount
Servicing & testing of LP 1A/2A/1B/ 2B/LP3/LP4/LP5
Servicing & Testing of seal cooler of BFP
Servicing & testing of working cooler of BFP
Servicing & testing of Lub oil cooler of BFP
Servicing & testing of motor cooler of BFP
Servicing & testing of air side shaft sealing cooler
Servicing & testing of H2 side shaft sealing cooler
Servicing & testing of Main ejector
Servicing & testing of starting ejector
Servicing & testing of gland steam coolers
Servicing & testing of chimney steam cooler
Servicing & testing of electric oil heater of centrifuging machine
Revisioning of servomotors of control valves
Revisioning of governing valve
Overhauling of hydrazine dozing pump
Cleaning of hotwell / deaerator
Servicing & testing of generator hydrogen cooler
Overhauling of Turbine main lub oil coolers(PHE)
Overhauling of Barring Gear
Servicing of extraction valves
Cleaning of strainers of CEP
Cleaning of strainers of BFP
Overhauling of BFP suction valve/Discharge valve/NRV
Attending flange leakages of main/starting ejector
Cleaning of condenser
Flood test of condenser
Overhauling of PRDS valves size from 65mm to 100mm
Attending leakages from flanges of ext.lines,steam lines, drains
Overhauling of high press steam valve/NRV of different line.
Valve size 25mm to 50mm
Valve size 65/100/125/150mm
Attending leakages from High pressure lines by cutting & welding work.
Revisioning of Low pressure steam/oil/water valves.
Valve size 25mm to 50mm
Valve size 51mm to 150mm
Valve size 151mm to 250mm
Valve size 251mm to 450mm
Replacement of welded HP valve by cutting & welding
Valve size 25mm to 50mm
Valve size 51mm to 100mm
Valve size 101mm to 150mm
Replacement of flanged end steam/Water valves
Valve size 25mm to 50mm
Valve size 51mm to 100mm
Valve size 101mm to 200mm
Valve size 201mm to 300mm
Valve size 450mm
Repairing of parting plane of condenser
Attending minor leakage from pipe ,bend ,etc at different place /location of turbine side including PRDS, Dearetor area.
Pipe size 25 mm to 150 mm
Pipe size above 150mm
Shifting of unworkable pump and placing new/repaired pumps.
sump pumps (Vertical/Horizontal)
Trolley pump
Condensate Extraction Pump
Auxiliary oil pump
EOP AC/DC oil pump
Starting oil pump
Seal oil pump (AC/DC)
Vacuum pump
I. Vapor Extraction fan
Condensate Booster pump
K. Chimney Steam Exhaust Fan
Jacking oil pumps
Servicing/Overhauling of defective pumps at site.
A- Condensate Booster Pump
Starting oil pump
Sump pumps
Trolley pump
Vapor Extraction fan
Condensate Extraction pumps
Chimney Steam Exhaust Fan
Jacking oil pumps
Decoupling, alignment and coupling of pumps with motor.
Condensate Booster Pump
Condensate Extraction pumps
Sump pumps
Auxiliary oil pump
EOP AC/DC oil pump
Chimney Steam Exhaust Fan
Hydrazine dozing Pump
Repairing of MOT tank filter (0ne job means repairing of one no of filter)
Replacement / Inspection of bearing and sleeve
Condensate Booster Pump
Condensate Extraction pumps
Sump pump
Trolley pump
Chimney Steam Exhaust Fan
Starting oil pump
Replacement / Inspection of bearing of CEP pump
Routine/Preventive maintenance of turbine side auxiliaries of unit-7, TMD, DTPS, HTPS Kasimpur Aligarh
M/S Thermal Erectors And Construction Co.
M/S AWAM ENGINEERING CO
SLB Erectors
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .