Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.3 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹34.4 L+₹3.1 L (9.97%)Rejected-AOC NO 9A VINAYAKANILAYA KANAKA GANAPATHI STREET OM SHAKTHI LAYOUT KANAKAGIRI HORAMAVU POST BANGALORE 560 043 | BENGALURU URBAN | KARNATAKA | 560043 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹37.8 L+₹6.5 L (20.9%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹39.2 L+₹7.9 L (25.3%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
₹31.4 L
EMD Value
₹62,800
Closing Date
19 Jun 2020, 6:00 pmClosed
BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
PROVN OF AUGMENTATION OF DRAINAGE FACILITY FOR KLP PH I AT ADMC BATHING POINT NEAR P 46 AND HARD STANDING IN FRONT OF T 7 AT TB III UNDER GE NORTH BANGALORE
2020_MES_343941_1
8421
Open Tender
Civil Works
Item Rate
150 days
BANGALORE
Class D Category a (i)
7 documents required · 7 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹62,800
Yes
19 Aug 2020
11 May 2020
20 Jun 2020
11 May 2020
19 Jun 2020
2 Jun 2020
11 May 2020 - 23 May 2020
Amount
B/R WORKS
Surface excavation n.exc. 30cm deep and average 15cm deep and getting out hard and dense soil complete all as specified and directed.
Excavating over areas n.exc. 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc., and and getting out in hard /dense soil complete all as specified and directed.
Excavating over areas exc. 1.5 mtr but n.exc. 3.00 mtr in in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc., and getting out in hard /dense soil complete all as specified and directed.
Excavating in trenches n.exc. 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc. 10 sqm on plan and and getting out in hard /dense soil complete all as specified and directed.
Plain Cement Concrete as in foundation filling and mass concrete (1:4:8), type D-2, using 40 mm graded stone aggregate complete all as specified and as directed.
Plain Cement Concrete (1:2:4), type B-1 using 20mm graded stone aggregate as in floors, 40mm thick finished even and smooth with out using extra cement complete all as specified and as directed.
Reinforced Cement Concret, M-30 (Design mix) using 20mm graded stone aggregate as in foundation footings complete all as specified and as directed.
Reinforced Cement Concret, M-30 (Design mix) using 20mm graded stone aggregate as in columns and similar articles all as specified and as directed.
Reinforced Cement Concret, M-30 (Design mix) using 20mm graded stone aggregate as in beams and slabs of any type and similar articles all as specified and as directed.
Reinforced Cement Concret, M-30 (Design mix) using 20mm graded stone aggregate as in retaining walls, basement walls, ballast walls and the like any thickness above top of footing inclding attached pilasters and buttersses complete all as specified and as directed.
Steel form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for fair finished flat surfaces of concrete complete all as specified and as directed.
Steel form work to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal for rough finished flat surfaces of concrete complete all as specified and as directed.
Steel form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, roof slabs etc., complete all as specified and as directed.
Steel form work to sides and soffits of retaining walls, basement walls, ballast walls and the like any thickness above top of footing inclding attached pilasters and buttersses complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc. 25 cm thick all as specified and as directed.
Removing excavated material(Soil) to a distance exc. 1.50 KM but n.exc. 5 KM and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
Hard core of guage n.exc. 63mm deposited spread and levelled, laid in layers n.exc. 15cm thick, watered and rammed to a true surface using broken boulders all as specified and as directed.
75 mm thick plain cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as in paving/ plinth protection laid in panels including necessary form work, finished rough surfaces of concrete complete all as specified and directed
CRS TMT steel bars 10mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed.
All as per Sl Item No. 1.019 here in before but 8 mm dia CRS TMT bars as in stirrups/spacers/binders.
Rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc, complete drilled for fixing of steel sheeting or other covering to doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging also fastening and fixing complete, steel conforming to Fe -290 (Gde-E- 165) quality-A all as specified and as directed.
Rolled Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
Preparation of new or previously untreated steel and iron surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel over a coat of red oxide primer, complete all as specified and directed.
Precast cement concrete block masonry with solid blocks exc. 10 cm in width and setting in cement mortar (1:6), type C1 (1:3:6) using 20 mm graded stone aggregate complete all as specified and as directed.
Precast Reinforced Cement Concrete, type B-1, (1:2:4) using 20 mm graded stone aggragate as in landings, cover slabs for manholes etc., chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain finished faces complete all as specified and as directed.
Rendering 22mm thick on fair faces of brick work or concrete surfaces in CM (1:3) finishing the surfaces even and smooth with out using extra cement mixed with approved water proofing compound complete all as specified and directed. NOTE :- WPC will be measured and paid separately.
Supply only integral liquide water proofing compound all as specified and as directed.
15mm thick rendering on brick or concrete surface in cement mortar (1:4) and finishing the surface with even and smooth without using extra cement complete all as specified and directed.
10mm thick rendering on brick or concrete surface in cement mortar (1:6) and finishing the surface with even and smooth without using extra cement complete all as specified and directed.
Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:3) finishing the surfaces even and smooth with out using extra cement mixed with approved water proofing compound complete all as specified and directed. NOTE :- WPC will be measured and paid separately.
Roof treatment by applying bitumen primer @ 0.27kg/sqm, providing 3mm thick APP modified water proofing membrane weighing not less than 3.8 kg/sqm reinforced with non woven polyester matt weighing not less than 180gm/sqm, having softening point not less than 140 centigrade, having tensile strength of 650 N/sq.cm in longitudinal and transverse directions, the reinforced tearing strength of 180N by torch application with minimum 10cm side overlap and 15cm end lap applying a coat of blown grade hot bitumen VG-10 over the membrane @ 1.2kg/sqm, top of membrane shall than be finished with solar reflective bituminous aluminium paint @0.10kg/sqm all as specified and as directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer all as specified and as directed.
Cast Iron soil,waste and vent pipes 100mm dia bore, in any length with or with out ears, with cement joints, laid in trenches or in floors all as specified and as directed.
Cast Iron bends (any radius) with duck's foot or heel rest 100mm dia bore all as specified and as directed.
Prepartation of new or previously un treated wall surfaces of any description and applying three coats white wash complete all as specified and as directed.
Excavation in post holes each n.exc .0.6 cum getting out, returning, filling in and removing earth or broken rubble mixed with earth around in layers not exc. 25 cm thick, watering, well ramming and removing surplus soil to a distance not exc. 50m and making good the disturbed surface as in soft /loose soil complete all as specified and as directed.
Surface excavation n.exc. 30cm deep and averaging 15 cm deep and getting out in soft / disentigrated rock complete all as specified and as directed.
Removing excavated material(Soil) to a distance not exc. 50 mtr and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
Plain Cement Concrete as in foundation filling and mass concrete (1:3:6), type C-2, using 40 mm graded stone aggregate complete all as specified and as directed.
Glazed coloured ceramic tiles as in vertical surfaces 350 x 250x 7 mm/ 450 x 350 x 7 mm/ 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over rendering 10mm thick in CM (1:4) backing coat on fair faces of brick work or concrete surfaces complete all as specified and as directed.
Non skid ceramic coloured tiles 7-8mm thick(square/rectangular) area of each tile not exceeding 0.11 Sqm as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and including 20mm thick screed bed in CM (1:4) complete all as specified and as directed.
Plain Cement Concrete (1:5:10), type D-2 using 40mm graded stone aggregate as in sub base to floors, 75mm thick complete all as specified and as directed.
Plain mild steel wire, galvanised class 3, in fencing including straining and fixing to wood, concrete or steel posts and/or to straining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, etc. all as specified and as as directed. NOTE:- Each line of wire to be measured.
Chequerred cement concrete tiles with grey cement and pigment, 300x300x20mm thick, set, jointed and pointed in neat cement slurry with grey cement and pigments to match the colour of tiles over 20mm thick screed bed in CM (1:4) complete all as specified and as directed.
Brick work using sub class 'B' bricks in half brick wall built in CM (1:4), straight or curved on plan exc. 6m mean radius complete all as specified and as directed.
TMT steel bars 8mm dia cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed.
Vitreous china coloured wash hand basin, oval shape, fitted in granite slab including providing and cutting 18mm to 19mm thick granite of size 0.90 x 0.60m including brass chromium plated pillar tap 15mm dia, single lever, waste coupling, PVC waste pipe, PVC connecting pipe complete all as specified and as directed.
75mm bore PVC (SWR) pipe, type 'B', single socketed in any length with rubber ring joints laid in trenches or floors complete all as specified and as directed.
75mm bore PVC (SWR) bends, type 'B' fixed with PVC solvent complete all as specified and as directed.
110mm bore PVC (SWR) pipe, type 'B', single socketed in any length with rubber ring joints laid in trenches or floors complete all as specified and as directed.
Unplasticised PVC pipes of pressure rating 10 kgf/cm2, 32 mm dia fixed complete to walls, ceilings or in floors etc.,complete all as specified and as directed.
PVC Connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
Aluminium anodised tubular towel rail 20mm dia, 60cm long complete all as specified and as directed.
20 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings and specials complete all as specified and as directed.
25 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings and specials complete all as specified and as directed.
Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe 410-W (Gde E-250) quality A complete all as specified and as directed.
Rolled mild steel sections as in plates (plain or chequered) channels, square cut or notched Fe-290 (Gde E-165) (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed.
Rolled mild steel as in roof trusses (framed), trussed purlins crane gantries rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces cleats etc.,steel conforming to Fe 410-W (Gde-E- 250) quality-A all as specifeid and as directed.
Pre-painted galvaniume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tenisile strenth of 550 Mpa as in roof covering cladding to wall, pre fixed with self taping screwes as specified and as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Plain Cement Concrete, (1:2:4), type B 1, using 20mm graded stone aggregate as in copings benching of manholes and similar work etc including necessary form work complete all as specified and as directed.
Plain Cement Concrete, (1:4:8), type D-2, using 40mm graded stone aggregate as in concrete bed to drain pipes including forming cradles in for PVC(SWR)/RCC pipes after they are laid and tested sutable for for 110mm dia bore pipe all as specified and as directed
Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm tihck plain colour PVC sheet reinforced with M S square tubes, fixed in opening as per drawings complete all as specified and as directed.
Factory made solid PVC moulded door shutter , 28 to 30mm thick (styles) wuth 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face & 2mm plain colour PVC sheet on back face supplying and fixing in frame at site as per specification & drawing with wood free EPS complete all as specified and as directed.
PTMT butt hinges, 100 mm long and fixed with steel screws complete all as specified and as directed.
PTMT tower bolts, 150 mm long and fixed with steel screws complete all as specified and as directed.
PTMT door handles, 150 mm long and fixed with steel screws complete all as specified and as directed.
Stop valves 15mm dia, standard PTMT of any colour, high pressure, screwed for iron pipe and fixed complete all as specified and as directed.
Bib taps 15mm dia, standard PTMT of any colour, high pressure, screwed for iron pipe and fixed complete all as specified and as directed.
Overhead shower rose of PTMT any colour 125 mm size with or without swivel joints, any size, including fixing to pipe or union complete all as specified and as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 2000 ltrs capacity complete all as specified and as directed.
20mm dia Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed(Min weight 20mm-210 gms) all as specified and as directed.
Gun metal gate or globe valves 25 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed
PVC (SWR) gully trap 125/110 mm dia , setting and jointing with solvent cement including jointing to waste pipe fixed in cement concrete (1:2:4) type B1(1:2:4) complete all as specified and as directed
PVC (SWR) floor trap with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4) complete all as specified and as directed
Plain Cement concrete (1:4:8), type D2, using 40mm graded stone aggregate as in sub bases of floors, 100mm thick, complete all as specified and directed.
Plain Cement Concrete (1:2:4), type B-1 using 20mm graded stone aggregate as in floors, 100mm thick finished even and smooth with out using extra cement complete all as specified and as directed.
Aluminium dividing strips, 1.5 mm thick, 38mm wide inserted in position, conform to design complete all as specified and as directed.
E/M WORKS
Excavating in trenches n.exc. 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, for laying of cable etc. and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers with hard/dense soil not exc. 25 cm thick in each layer complete as specified and as directed.
Removing excavated material(Soil) to a distance not exc. 50 mtr and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
Sand cushioning in layers for cables in trenches / ducts for cable including consolidation complete all as specified and directed. NOTE: Punned thickness will be measured for payment purpose.
Bricks, sub class 'B' of old size 230 mm x 115 mm x 75 mm laid in trenches for cable protection all as specified and directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 25 sq.mm, 3.5 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing complete all as specified and as directed.
Earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge not less than 1.5 m below ground level connected to earth lead by GI wire 4 mm dia by means of bolts nuts, check nuts, washers made out of galvanised iron connected to main switch all as shown in elect plate No 3 of MES SSR Part -I includingn excavation and earth work in any type of soil,funnel, 20 mm dia light grade GI watering pipe with chamber of PCC 1:3:6 type C1 40mm thick of size 450mm x450mm (1:2:4) type B1 for cover slab reinforced with 8mm dia TMT bars 10cm c/c both ways and with 6mm MS hook etc complete all as specified including testing on completion all as specified and directed.
Non clog self priming 3 phase coupled sewage pumpset with 10C4 motor suction and delivery pipe of size 100 x 100 mm, solid handling size of 18.5 mm, power rating 10 HP and 7.5 KW, head range 10-24 metre, flow range-2130-840 LPM packaging unit-1, all as per Kirloskar Cat No. SP4LA+ or techno commercially equivalent makes specified in PS including PCC foundation ,nuts ,bolts & suction and delivery pipe connections all as specified and as directed.
Supply, installing, testing and commissioning of LT panel box made out of CRCA sheet 2.0 mm thick, cubical and out door type, factory made with front opening type suitable for 415 volts, 3phase, 4wire, 50 Hz, AC supply having 3 Nos aluminium busbars of 100 Amps and neutral bus bar of 50 Amps capacity duly insulated with heat shrinkable colour coated sleeves complete, painted with powder coated with pure polyester,60 microns thickness RAL- 7032 code with locking arrangement, mounted on base channel of suitable size ISMC grouted with PCC foudationof suitable type including provision of the following accessories:- (a) MCCB 100 Amps, 4 pole, 415 Volts, 16 KA rupturing capacity-01 (Incoming). (b) MCB 40 Amps, 4 pole, 430 volts, 16 KA rupturing capacity-2 Nos (Out going). (c) On line change over switch 3 pole, 415 volts, 63 Amps with open execution type 1NO. (d) Fully automatic star delta stater suitable for 10 HP Pump set-01 . (e) Indicating lamps R,Y,B NEON type 220 volts, AC 50 Hz.
Excavating in trenches n.exc. 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, for laying of cable etc. and getting out in soft / loose soil complete all as specified and as directed.
Ductile Iron pipe, 100mm dia, K-7 with spigot and socket ends conforming to IS 8329 :2000, with inside surface of centrifuglly cast cement mortar lining suitable for rubber joints / tyton joints in any length laying in trenches, jointed and tested all as per IS 12288-1987 complete all as specified and as directed.
Cast Iron sluice valve 100 mm dia with steel spindle bronze gate & seating rings conforming to IS 14846-2000 class 1.6 PN with ISI mark embosed on it, including jointing materials such as rubber insertion gaskets, suitable size of nuts, bolts, washers etc, including jointing and testing complete all as specified and as directed.
Brick masonary valve chamber of size 900 mm x 900 mm x 860 mm (internal diemensions) with 100mm thick foundation PCC, (1:4:8), type D2 using 40 mm grade stone aggregate, brick wall 230mm thick, with sub class B old size bricks built in cement mortar (1:6), PCC (1:2:4) type B1 using 20mm graded stone aggregate for coping 75 mm thick, rendering in cement mortar (1:4),15 mm thick for internal and external surfaces, finished fair and even,provision of MS sheet cover made out of 2 mm thick sheet fixed to MS angle iron frame made out of 40 x 40 x 4 mm thick with two coats of synthetic enamel paint over one coat of red oxide primer to steel surfaces and locking arrangements with 6 levers Godrei lock complete all as specified and as directed.
Ductile iron fittings of any size, any type with all sockets and spigot fittings such as bends, tappers, collers, Tees, plugs etc up to 100 mm bore as per site requirement complete all as specified and as directed.
Cast Iron Air release valve 100 mm dia with single air outlets, conforming to IS 14845 fixed to DI pipe complete all as specified and as directed.
Cast Iron non return valve 100 mm dia including fixing arrangements complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 10 sq.mm, 2 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing complete all as specified and as directed.
Galvanised iron pipe of 40 mm dia, medium grade, laid in trenches, floors / fixed to wall with all fittings such as socket, bends, elbow, union etc., complete all as specified and as directed.
Galvanised iron pipe of 25 mm dia, medium grade, laid in trenches, floors / fixed to wall with all fittings such as socket, bends, elbow, union etc., complete all as specified and as directed.
Gun metal gate or globe valves 25 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Gun metal gate or globe valves 40 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Wiring complete with 1.5 sq.mm single core FRLS PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable conforming to IS 694 drawn through and including non-metalic rigid PVC conduit of suitable size, medium grade including necessary accessories surface type run on walls/ ceiling with MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for one light point controlled by one switch.
All as per Sl Item No. 2.022 here in befroe but for 3 pin socket out let 5 Amps on independent board. NOTE FOR SL ITEM NO. 2.022 & 2.023 :- (i) The earth wire for the points in the same circuit can be looped from point to point. (ii) Earth wire shall be taken inside the conduit. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring. (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring.
LED tube light fittings along with 18 watts, 4 feet long LED tube with all necessary fixtures suitable for indoor application, wall mounted, extruded aluminium heat shink provision with efficient heat dissipation, integrated electronic driver, powder coated top cover complete with all accessories internally pre wired and including connecting up twin core flexible copper wire complete all as per Bajaj Cat Part No : BCLSB 18 WH or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Switch Piano, flush type, one way, 5 Amps, 240 Volts single pole with ISI marked complete all as specified and as directed.
Switch socket combination 3 & 2 pin, 5 Amps, 240 Volts, flush type multipurpose controlled by one switch all as specified and as directed.
Ceiling rose, surface bakelite type, 65 x 50 mm, 2 to 3 terminals all as specified and as directed.
MCB DB SPN, 4 ways, 240 volts with 200 Amps rated busbar with double door for housing MCBs all as specified and as directed.
MCB single pole 240 volts 5 to 40 Amps complete all as specified and as directed.
MCB single pole and neutral, 240 volts, 32 Amps complete all as specified and as directed.
PRACHANIVA CONSTRUCTIONS
SARAVANA TRADERS
SRI LAKSHMI ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .