| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC VILL JAMALPUR P O NAYA MAHMMADPUR DISTT BHOJPUR ARA PIN 802163 | ARA | BHOJPUR | BIHAR | 802163 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹17.3 L+₹83,088.60 (5.04%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹18.9 L+₹2.4 L (14.8%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹20.8 L+₹4.3 L (26.3%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
27 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NARANGI
GE Narangi C/O 99 APO Guwahati
REPAIR / REPLACEMENT TO LT DISTRIBUTION SYSTEM SERVICES IN PH-I ACCN AND REPAIRS TO EXTERNAL ELECTRIC INSTALLATIONS INCLUDING REPAIRS TO OVERHEAD / UNDERGROUND ELECTRIC SUPPLY LINE AND OTHER ALLIED WORKS UNDER GE NARANGI.
2020_MES_348373_1
8555/NAR/E8
Open Tender
Civil Works
Item Rate
180 days
GE NARANGI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NARANGI
₹40,000
Yes
31 Jul 2020
29 May 2020
1 Jul 2020
29 May 2020
27 Jun 2020
13 Jun 2020
60 days
Amount
SCHEDULE 'A' PART-I
Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation, laying of cable or for shafts, wells cesspits,man holes, foundation of pole etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling, in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and as directed.
Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed.
M & L for dry river sand in trenches for cushioning of underground cable including spreading, levelling, hand punning complete all as specified and as directed. Note:Punned thickness will be measured and paid.
Supply and laying well burnt sub class ‘B’ bricks locally available best quality laid dry in trenches for protection of underground cable laid flat with length for brick perpendicular to length of cable complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position complete all as specified and as directed.
M&L for PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed.
M&L for PCC 1:3:6, type C1 (using 20 mm graded stone aggregate) as in coping of pole, fixing of post, etc. including for use of necessary formwork (straight or curved) complete all as specified and as directed.
Taking out old unserviceable LT underground cable of any size from trenches/wall /floor /road /culverts or pole including taking up bricks laid as cable protection, GI protection pipe complete all as specified and as directed. Note: Excavation and earthwork shall be measured and paid seperately.
M & L for relaying old serviceable UG cable of any size/ type in trenches or on wall/ roof etc. after necessary repair/ rerouting works complete all as specified and as directed. Note : (i) Old serviceable cable obtained from taking down under item No 9 above shall be reused. (ii) Brick protection and sand cushining shall be measured and paid separately under respective item.
Supply, laying and testing XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 Sqmm, 3.5 core complete all as specified and as directed
All as per item No 11 here in before but of size 185 Sqmm 3.5 core.
All as per item No 11 here in before but of size 120 Sqmm 3.5 core.
All as per item No 11 here in before but of size 70 Sqmm 3.5 core.
All as per item No 11 here in before but of size 50 Sqmm 3.5 core.
All as per item No 11 here in before but of size 25 Sqmm 3.5 core.
M & L for manual boring of holes under road,pavement, hard standing where ordered for inserting GI pipe 40 mm to 80 mm bore dia complete all as specified and as directed. (Note : - GI pipe 40/50/80 mm will be measured & paid seperately.)
Supply and fixing GI tube light grade of size 80 mm bore dia conforming to IS 1239 of 1990 for protection of LT cable laid in trenches / inserting under road or fixing on wall / pole etc. complete all as specified and as directed.
M & L for GI tubing light grade of size 50 mm bore dia, conforming to IS 1239 of 1990 for protection of LT cable laid in trenches / inserting under road or fixing on wall/pole etc. complete all as specified and as directed.
M & L for GI tubing light grade of size 40 mm bore dia conforming to IS 1239 of 1990 for protection of LT cable laid in trenches / inserting under road or fixing on wall/pole etc. complete all as specified and as directed.
M & L for cable jointing kit for LT (Earthed) grade XLPE cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 25 to 50 Sqmm,3.50 core complete all as specified and as directed.
S & F in repairs, stain-less steel enclosure for MCCB of rating 250Amp In-built neutral Link for TPN system lIK08 and IP30 Protection having Louvers for better heat dissipation Suitable to accommodate upto 185 sq. mm. 3.5 core Aluminum armoured cable connecting to existing Incoming/Outgoing cable with proper dimension lugs complete all as specified and as directed. Make : L &T cat part No. CM91003OOOO or equivalent in Havells /CG/Schneider
S & F in repairs, MCCB with thermal - magnetic release of 200 to 250 Amps, 4 Pole, 415V, 25 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories complete all as specified and as directed. Make : L & T Cat Part No. CM90642OOPO or equivalent in Schneider/ Legrand
S&F in repairs, MCCB with Thermal - magnetic release of 320 to 400 Amps, 4 Pole, 415V, 36 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories complete all as specified and as directed. Make : L & T Cat Part No. CM98403OOROOG or equivalent in Schneider/ Legrand
S&F in repairs pin type porcelain insulator of size 100mm height, 65mm dia, vitreous, white, brown or green including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut for 1100 volts grade complete all as specified as directed.
S & F in repairs, shackle type insulator, porcelain, vitreous, white, brown or green, 75mm height 90mm dia for working pressure of 1100 volts including galvanized steel straps of section 31x3mm, 12mm dia of bolts, washers and nuts complete all as specified and as directed.
Dismantling of steel tubler poles,struts of any size including foundation concrete, coping, cross arms, bracings, insulators complete all as specified and as directed.
Supply & erecting in true vertical position steel tubular swaged pole 9 metre long with MS base plate 300x300x6 mm welded to base complete all as per type 410 - SP - 31 including two coats of aluminium paint and with black paint at bottom over a coat of red oxide primer complete all as specified and directed. (Note :- (i) PCC shall be measured and paid seperately under respective item) (ii) Steel pole shall be installed at existing location.
S & F in repairs of stay assembly complete using 20 mm dia stay rod complete with accessories as shown in electrical plate No 1 including one loop type insulator large size 90 mm x 140 mm, clearance of hole 25.5 mm and galvanized stay strand of size 7/4 mm-11 metre(7.92Kg) complete all as specified and directed. Note : (i) provision of PCC shall be measured and paid seperately under respective item). (ii) Stay assembly shall be installed at existing location.
M & L for cross arms, bracings, supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps, stay clamps, D clamps nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed, including painting two coats of aluminium paint over a coat of primer complete all as specified and as directed.
Fixing only serviceable cross arm obtained from dismantling of pole under item No 27 complete all as specified and as directed.
Dismantling of old unserviceable ACSR conductors of any size from over head lines, poles by removing binding wire, service wire, cables,insulators etc complete all as specified and as directed.
M&L for ACSR conductors (weasel type) for LT OH lines on poles including stringing, binding with & including aluminium wire, 14 SWG or aluminium tape including jumpers complete connecting of disconnected cable, service cable and street light connection complete all as specified and as directed.
S & F in repairs, cradles, hexagonal / rectangular, fabricated with galvanized steel wire 4 mm dia including stretching,jointing in position as a continuous earth wire on pole and for guarding complete all as specified and as directed.
Taking down old unserviceable / corroded LT feeder pillar box/ DB Box/ Busbar Chamber of any sizes or types (after disconnectin of all electrical connection, including dismantling of supporting framwork, foundation concrete etc.) complete all as specified and as directed.
Supply, Install, testing and commissioning CPRI approved LT feeder pillar box of suitable size (leg of the feeder pillar should not be less than 600mm length) out door type, made out of 3.15 mm thick CRCA sheet supported and fixed on structural frame, made up of not less than mild steel ISA 40 x 40 x 6 mm, factory made duly fixed on the ground by PCC foundation 1:2:4 Type B-1 of size 700mm x300mm x600mm on the adjacent pairs of leg & net cementing the same. The feeder pillar box should duly painted with two coats of synthetic enamel paint over a coat of red oxide primer (internally & externally) on the surface all as specified and directed by Engr-in-Charge. The feeder pillar box shall be cubical shaped, roof canopy type, with special type of heavy duty industrial door hinges and totally enclosed dust proof and vermin proof front and back opening with locking arrangements & comprises of following electrical items.
INCOMING: (i) Aluminium bus bar 4 strips (covered with colour coded insulated PVC sleeves) 200 Amps capacity, 60-70 cm long including connection etc complete – 01 Set (ii) Indicator lamp for RYB phase -01 set (iii) MCCB 63-80 Amps 415 Volts, Thermal Magnetic release with adjustable over load setting and adjustble short circuit setting,4 pole, ,Ics=100% Icu,25 kA breaking capacity.= 01 Nos. Make : L & T Cat Part No. CM91712OOJOOG or equivalent in Schneider/ Legrand. (i) MCB Four Pole 40Amp, C curve , Breaking capacity 10kA - 05 Nos Make L&T or equivalent in schneider/legrand Note-- All cables in the feeder pillar box should be properly glanded and thimbled as specified and directed by Engr-in-Charge .
Supply, Install, testing and commissioning CPRI approved LT feeder pillar box of suitable size (leg of the feeder pillar should not be less than 600mm length) out door type, made out of 3.15 mm thick CRCA sheet supported and fixed on structural frame, made up of not less than mild steel ISA 40 x 40 x 6 mm, factory made duly fixed on the ground by PCC foundation (1:2:4 Type B-1) of size 700mm x300mm x600mm on the adjacent pairs of leg & net cementing the same. The feeder pillar box should duly painted with two coats of synthetic enamel paint over a coat of red oxide primer (internally & externally) on the surface all as specified and directed by Engr-in-Charge. The feeder pillar box shall be cubicle shaped, roof canopy type, with special type of heavy duty industrial door hinges and totally enclosed dust proof and vermin proof front and back opening with locking arrangements & comprises of following electrical items.
INCOMING: (i) Aluminium bus bar 4 strips (covered with colour coded insulated PVC sleeves) 200 Amps capacity, 60-70 cm long including connection etc complete – 01 Set (ii) Indicator lamp for RYB phase -01 set (iii) MCCB 63-80 Amps 415 Volts, Thermal Magnetic release with adjustable over load setting and adjustble short circuit setting,4 pole, ,Ics=100% Icu,25 kA breaking capacity.= 01 Nos. Make : L & T Cat Part No. CM91712OOJOOG or equivalent in Schneider/ Legrand. OUTGOING (i) MCB Four Pole 40Amp, C curve , Breaking capacity 10kA - 04 Nos Make L&T or equivalent in schneider/legrand Note-- All cables in the feeder pillar box should be properly glanded and thimbled. .
Supply, Install, testing and commissioning CPRI approved LT feeder pillar box of suitable size (leg of the feeder pillar should not be less than 600mm length) out door type, made up to not less than mild steel ISA 40 x 40 x 6 mm, made out of 3.15 mm thick CRCA sheet supported and fixed on structural frame, factory made duly fixed on the ground by PCC foundation 1:2:4 Type B-1 of size 700mm x300mm x600mm on the adjacent pairs of leg & net cementing the same. The feeder pillar box should have enamelled danger notice plate of 1.6 mm thick, duly painted with two coats of synthetic enamel paint over a coat of red oxide primer (internally & externally) on the surface all as specified and directed by Engr-in-Charge. The feeder pillar box shall be cubicle shaped, roof canopy type, with special type of heavy duty industrial door hinges and totally enclosed dust proof and vermin proof front and back opening with locking arrangements & comprises of following electrical items.
INCOMING: (i) Aluminium bus bar 4 strips (covered with colour coded insulated PVC sleeves) 400 Amps capacity, 60-70 cm long including connection etc complete – 01 Set (ii) Indicator lamp for RYB phase-01 set (iii) MCCB 200-250 Amps 415 Volts, Thermal Magnetic release with adjustable over load setting and adjustble short circuit setting,4 pole,Ics=100% Icu, 36 kA breaking capacity.= 01 Nos. Make : L & T Cat Part No. CM92109OOP1OG or equivalent in Schneider/ Legrand (Incoming to FP Box) (iv) MCCB 63-80 Amps 415 Volts, Thermal Magnetic release with adjustable over load setting and adjustble short circuit setting,4 pole, 25 kA,Ics=100% Icu,breaking capacity.= 01 Nos (Outgoing to another FP Box). Make : L & T Cat Part No. CM91712OOJOOG or equivalent in Schneider/ Legrand OUT GOING (i) MCB Four Pole 40Amp, C curve , Breaking capacity 10kA - 05 Nos Make L&T or equivalent in schneider/legrand .
Supply, Install, testing and commissioning CPRI approved LT feeder pillar box of suitable size (leg of the feeder pillar should not be less than 600mm length) out door type, made out of 3.15 mm thick CRCA sheet supported and fixed on structural frame, made up of not less than mild steel ISA 40 x 40 x 6 mm, factory made duly fixed on the ground by PCC foundation 1:2:4 Type B-1 of size 700mm x300mm x600mm on the adjacent pairs of leg & net cementing the same. The feeder pillar box should duly painted with two coats of synthetic enamel paint over a coat of red oxide primer (internally & externally) on the surface all as specified and directed by Engr-in-Charge. The feeder pillar box shall be cubicle shaped, roof canopy type, with special type of heavy duty industrial door hinges and totally enclosed dust proof and vermin proof front and back opening with locking arrangements & Comprises of folloing electrical items.
INCOMING: (i) Aluminium bus bar 4 strips (covered with colour coded insulated PVC sleeves) 450 Amps capacity, 60-70 cm long including connection etc complete – 01 Set (ii) Indicator lamp for RYB phase -01 set (iii) MCCB 250-320 Amps 415 Volts, Thermal Magnetic release with adjustable over load setting and adjustble short circuit setting,4 pole,Ics=100% Icu, 36 kA breaking capacity.= 01 Nos. Make : L & T Cat Part No. CM98403OOQOOG or equivalent in Schneider/ Legrand (Incoming to FP Box) (iv) MCCB 200-250 Amps 415 Volts, Thermal Magnetic release with adjustable over load setting and adjustble short circuit setting,4 pole,Ics=100% Icu, 36 kA breaking capacity.= 01 Nos. Make : L & T Cat Part No. CM92109OOP1OG or equivalent in Schneider/ Legrand (Outgoing to another FP Box). OUT GOING (i) MCB Four pole 40Amp, C curve , Breaking capacity 10kA - 05 Nos Make L&T or equivalent in schneider/legrand (Note: For item no.36 to 39 The drawing of the feeder piller box to be approved by Accepting Officer and contractor shall submit the same before giving the order to the manufacturer)
M & L for Earthing complete with galvanized steel earth plate 60cm x 60cm x 6.3mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth strip, 25mm x 4mm up to test point by means of nuts, bolts, check nuts and washers of GI including excavation and earth work, PCC 1:3:6 type C-1 pit, 20mm dia GI pipe medium grade, watering pipe and 40mm bore GI pipe light grade for protection of earth strip, MS angle iron frame 40x40x3mm, 40mm thick RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 75mm C/C both ways and with MS handle made out of 12mm dia bars, PGI Funnel, wire mesh etc complete all as shown in electrical Plate No. 03 of SSR Part-I and connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed.
M & L for prunning / trimming the branches of trees if any along overhead line, 3 m on all side below/ above/ sides of overhead line and removing the same upto 150 m away each span not exceeding 45 m complete all as specified and as directed.
M&L for cutting grass, shrubs/ herbs around LT/ HT pole, Feeder Pillar Box, Installations using mechanical or manual T&P, removing the debris at a distance not exceeding 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and as directed.
SONI ENTERPRISE
PURBANCHAL BUILDERS
M/s KRISHNA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .