| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.8 CrAccepted-AOC MATERE HOUSE SEC NO 14 PRADHIKARAN PUNE MAHARASHTRA INDIA 412105 | PUNE | MAHARASHTRA | 412105 | ₹10.8 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹12.0 CrRejected-Finance 208 2ND FLOOR EXPRESS MARKET AMBEDKAR ROAD GHAZIABAD 201001 UP | GHAZIABAD | UTTAR PRADESH | 201001 | ₹12.0 Cr | L2 | Rejected-Finance NOT THE LOWEST |
| 3 | L3₹12.2 CrRejected-Finance | ₹12.2 Cr | L3 | Rejected-Finance NOT THE LOWEST |
| 4 | L4₹13.5 CrRejected-Finance | ₹13.5 Cr | L4 | Rejected-Finance NOT THE LOWEST |
| 5 | L5₹13.8 CrRejected-Finance | ₹13.8 Cr | L5 | Rejected-Finance NOT THE LOWEST |
Tender Value
₹10.5 Cr
EMD Value
₹8.5 L
Closing Date
14 Nov 2019, 6:00 pmClosed
Chief Engineer Pune Zone Dakshin Kaman Marg Camp
Chief Engineer Pune Zone Dakshin Kaman Marg Camp Pune 411001
PROVN OF SWIMMING POOL AT KIRKEE
2019_MES_250266_3
84439/E8
Open Tender
Civil Works
545 days
KIRKEE
AS PER TENDER
6 documents required · 6 mandatory
₹3,000
GE MH AND RH KIRKEE
₹8.5 L
22 Jan 2020
31 Oct 2019
15 Nov 2019
31 Oct 2019
14 Nov 2019
9 Nov 2019
1 Nov 2019 - 8 Nov 2019
Amount
NOTE: Schedule ‘A’ Part I to X are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-13 only.
Total amount of Sch 'A' Part-I (Building Works)
Total amount of Sch 'A' Part-II (Internal water supply)
Total amount of Sch ‘A’ Part III (Internal Electric Supply)
Total amount of Sch ‘A’ Part IV (External Water Supply)
Total amount of Sch ‘A’ Part V (External Electric Supply)
Total amount of Sch 'A' Part-VI (Road, Path, Hardstanding and Culverts)
Total amount of Sch 'A' Part-VII (Sewage Disposal)
Total amount of Sch ‘A’ Part VIII (Area drainage)
Total amount of Sch ‘A’ Part IX (Boundary wall & steel gate)
Total amount of Sch ‘A’ Part X (Excavation, Earthwork & Site Clearance)
SCH 'A PART XI (Miscellaneous B/R and E/M works) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
Material & labour for construction of valve pit chamber having internal dimensions 900mmx900mmx900mm in PCC 1:4:8 type D-2 using 40mm stone aggrgate for foundation of 150mm thick, 150mm wide offsets around over 100mm thick hard core, 200mm thick PCC solid block walls in cement mortar 1:4, PCC coping 50mm thick in cement concrete 1:2:4 using 20mm graded stone aggregate finished smooth, rendering cement plaster 10mm thick in cement mortar 1:4 and finished even and smooth without using extra cement internally all round and externally upto 300mm from top including fabrication of MS cover embedded to chamber, using 40x40x6mm angle iron,MS plate of size 1200mmx1200mm and 6.00mm thick,handle made out of flat iron of size 25x4mm, butt hinges heavy weight, cold rolled mild steel of size 125mm-2Nos, including painting to steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer including excavation and earth work in hard /dense soil complete all as specified and directed by Engr-in-charge.
Supply, laying, testing of DI pipe of 150mm bore spigot & socketed ends with cement mortar lining inside, centrifugally cast spun ductile iron pressure pipe class 'K-7' conforming to IS 8329/2000, in any length suitable for push on joints (rubber gasket tyton joint) and laid in trenches /floors etc. complete all as specified and as directed.
Cutting existing water supply pipe and inserting Tee of size 200x200x150mm with reducer of 150mm for taking out new branch connection without taking out, complete all as specified and as directed.
M & L for 150mm thick (compacted thickness) Wet Mix Macadam (WMM) laid in two layers 75mm each layer, laying spreading (with paver finisher only) and compacting base course of graded stone aggregates and granular material conforming to MORT&H specifications,(Table 400-II) in layers of equal compacted thickness each, consolidated, including pre-mixing the material with water at OMC in mechanical mixer, carriage of mixed material by tippers to site, laying in uniform layers in base course on a well prepared sub base/ base course and compacting with power vibratory roller to achieve the desired density complete as per MORT&H specification clause -406 including material, labour, machinery, lighting, guarding and maintenance of diversion, complete all as specified and as directed.
M&L for 80mm thick machine pressed pre-cast cement concrete interlocking paver blocks with grey cement and pigment, rubber moulded any shape and size confirming to IS 15658-2006, M-40 grade as in floor/pavement laid over and including 30mm thick crushed stone sand complete all as specified and as directed.
M&L for M&L for Pre-cast cement concrete edge kerb of size 450mm x 300mm x 150mm (H x L x Thickness) (factory made) in M-25 (Design mix), straight or curved on plan not exceeding 6m mean radius and set in cement mortar (1:4) complete all as specified and as directed.
M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including Galvanised steel earthing wire 4mm dia by means of bolts, nuts & checknuts and washers etc; GI pipe 15 mm dia medium grade pipe for protection of G.I earth strip, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion.
M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including GI strip 32x6 mm by means of bolts, nuts & checknuts and washers etc; GI pipe 40 mm dia medium grade pipe for protection of G.I earth strip, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion.
M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including GI strip 25x4mm by means of bolts, nuts & checknuts and washers etc; GI pipe 40 mm dia medium grade pipe for protection of G.I earth strip, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion.
Supply & fix ceiling fan, 1200 mm (48") sweep, 5 star rating BEE mark (after assembling the same) with the fan hook/box and connecitng up complete with and including electronic fan regulator stepped type flush and with and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to porcelain connector block of fan complete all as specified and directed Make : Havells Cat No ES-50 or equivalent in makes listed in Appendix 'C'.
Supply & fix exhaust fan 300mm sweep, 1400RPM, single phase, light weight, white/ivory plastic rust proof body & blades, self opening louvers for protection from birds and rain water, fixing by means of rugged bolts, nuts and washers etc on the round hole cut in wall, including three core copper conductor flexible cord of 0.5sqmm cross sectional area of required length from ceiling rose to porcelain connector block of exhaust fan suitable on working AC, SP 230 V electric supply complete all as specified and directed. Make CG cat Brisk air or equivalent in makes listed in Appendix 'C'.
Supply & fix exhaust fan 380mm sweep, 1400RPM, single phase, light weight, white/ivory plastic rust proof body & blades, self opening louvers for protection from birds and rain water, fixing by means of rugged bolts, nuts and washers etc on the round hole cut in wall, including three core copper conductor flexible cord of 0.5sqmm cross sectional area of required length from ceiling rose to porcelain connector block of exhaust fan suitable on working AC, SP 230 V electric supply complete all as specified and directed. Make CG cat Brisk air or equivalent in makes listed in Appendix 'C'.
M &L for submain wiring with 2 single core FRLS PVC insulated unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 10.0 Sqmm drawn through consealed /surface conduit and including PVC conduit heavy grade with and including 1 single core 10.0 Sqmm 1100 V grade FRLS PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified, directed.
M &L for submain wiring with 4 single core FRLS PVC insulated unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 6.0 Sqmm drawn through consealed /surface conduit and including PVC conduit heavy grade with and including 2 single core 6.0 Sqmm 1100 V grade FRLS PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified, directed.
M &L for submain wiring with 2 single core FRLS PVC insulated unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 4.0 Sqmm drawn through consealed /surface conduit and including PVC conduit heavy grade with and including 1 single core 4.0 Sqmm 1100 V grade FRLS PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified, directed.
M &L for submain wiring with 2 single core FRLS PVC insulated unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 2.5 Sqmm drawn through consealed /surface conduit and including PVC conduit heavy grade with and including 1 single core 2.5 Sqmm 1100 V grade FRLS PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified, directed.
S&F MCB Single pole 240 volts 6 Amps to 32 Amps 10 KA complete all as specified and directed.
S&F MCB Single pole and neutral 240 volts 6 Amps to 32 Amps 10 KA complete all as specified and directed.
S&F MCB Four Pole (TPN) 240 volts 6 Amps to 32 Amps 10 KA complete all as specified and directed.
S&F LED light fitting 1x20 watt, 230 volt, energy saver indoor domestic plastic extruded luminaire with decorative complete all as specified and as directed. Cat part No. LTIC00120WLED/ED of C&S or equivalent in makes listed in Appendix 'C'.
S&F LED light fitting 1x18 watt, 230 volt, energy saver indoor domestic plastic extruded luminaire with decorative complete all as specified and as directed. Cat part No. LCTL-18-CDL of Crompton or equivalent in makes listed in Appendix 'C'.
S & F LED mirror light fitting 1x08 watt 230 volts, energy saver, luminaire with decorative complete all as specified and as directed. Cat part No. Crompton Cat No DMLN1LT8 or equivalent in makes listed in Appendix 'C'.
S&F angle holder, PVC/Polycarbonate type with back plate including supply and fix of LED 1x09 watt, 230 volts complete all as specified and as directed and as directed Cat No CHANDRA/9W/W of Bajaj or equivalent make as mentioned in Appendix 'C'.
S&F Porch light surface mounted LED with PMMA diffuser and lamp 24Watt, 230 volts, energy saver complete all as specified and as directed. Cat part No. Wipro Cat No CRCO14S024H57 or equivalent in makes listed in Appendix 'C'.
S & F post top lantern LED type light fittings with lamp, 25 watt, die-cast aluminium body with UV stabilized poly corbonate diffusers including suitable driver and also suitable for fixing on MS post of dia not less than 76 mm complete all a specified and as directed all as per makes listed in Appendix 'C'.
M & L for steel pole to install bollard fittings made out of GI tube 80mm bore medium grade with fittings 2.5m above ground and 0.5m embedded in ground with PCC 1:3:6 Type C-2 using 40mm graded coarse aggregate of size 0.3mx0.3mx0.3m foundation including excavation and earth work in any type of soil including provn of PVC insulated copper conductor of size 2x1.5 Sqmm and 1x1.5sqmm as in earth wire.
S&F LED security light fitting 30 Watt 230 Volts with all necesary accessories & complete all as specified and as directed including necessary brackets, GI pipe 32mm dia 1.2 M length, medium grade tube including two Nos of clamps fixed with suitable size screws. Make :- C&S, Cat part No LTESS30WLED or equivalent in makes listed in Appendix 'C'.
Supply, laying, testing and commissionnig of UG LT cables 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminum conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/MDB in building etc to suit the cable including material and labour for all jointing/connecting material as required size, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete of following sizes :-
(a)185 sqmm x 3.5 core
(b) 95 sqmm x 3.5 core
(c) 25 sqmm x 4 core
(d) 10 sqmm x 2 core
(e) 6 sqmm x 2 core
M & L for river sand cushioning (dry) in trenches/ ducts for protection of UG cables (below, above and around the UG cable laid in trenches) of 23 cm spread thickness (8 cm in depth before laying the cable and 15 cm in depth after laying the cable) and consolidated (punned) upto 18 cm thickness, complete all as specified and as directed. . . Note-Punned thickness will be considered for payments purpose.
S & F street light fittings pressure die cast aluminium 40 Watt, with and including lamp including necessary bracket, GI 32mm dia medium grade pipe 1.2m long including 2 Nos of clamps and connecting flexible copper conductor wire PVC insulated of 2x2.5Sqmm and 1x2.5Sqmm as in earth conductor, Cat No HPLLEDSL 4060S of HPL or equivalent in makes listed in Appendix 'C'.
S & F factory made PVC Junction boxes for bollard light fittings and street light fittings, weather proof IP-54 protection, hinged door, with 10 A Aluminium bus bar, 240V, neutral link and 01 No MCB SP of 6Amp, necessary fixing arrangement such as clamps, nuts, bolts, etc Make Hansel KF 5250 or equivalent in Sintex/Standard all as specified and as directed.
Supply, installing, testing and commissioning, weather, dust and vermin proof LT cubical panel board factory made, indoor type, as per IS-8623 fabricated with 2mm thick CRCA sheet epoxy powder paint by means of electro static gun after rogorous pre treatment comprising of cold phosphating process on all internal and external surfaces after due preparation of surfaces. The panel shall consist of 400Amp rating bus bar of high conductivity copper alloy for phases and half for neutral and shall be provided with colour coded head shrinkable sleeves, including bottom gland plate consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/Rubber bushes to prevent ingress of water/vermin etc., inside the enclosure the required No of holes to be fixed with chromium plated brass cable glands for incoming and outgoing cables, with necessary internal wiring with stranded copper conductor PVC insulated cable of adequate quantity including 07 Nos Star Delta starters 20 Amps complete with over load relay, single phase preventer, reverse phase and under voltage protection etc. complete and connecting up to pumps including supply and suitable size copper cable from panel to pumps in and including PVC conduit concealed in floor /walls all as directed. The panel shall be provided with seperate comparments for each switch gear etc, with double stud hinged door, front openable with locking arrangement and suitable for 1100Volts grade, 3Phase, 415 Volts, 50 cucles, AC supply and to with protection shall be IP48. The panel shall be fixed with angle iron frame made of angle 50x50x6mm welded in shape with two coats of synthetic enamel paint over a coat of red oxide primer including necessary fixed on wall comprising of the following:-
(a) Copper bus bar 400Amps-03 Nos for phases and half for neutral duly colour sleeved mounted on epoxy/FRP bus bar-01 Set
(b) Incoming
i) MCCB 300 Amps, FP, 25 KA Breaking capacity, 415V, 50Hz - 01 No
(c) Outgoing
i) MCB 40 Amps, TP, 415V, 50Hz, 10 KA - 10 No.
ii) MCB 20 Amps, TP, 230 V, 50 Hz, 10KA -03 No.
iii) MCB 40 Amps, SP, 230 V, 50 Hz, 10KA -02 No.
iv) Phase indicator lamps (RYB) -Set of three-01No
v) Internal wiring with suitble size copper condiuctor PVC insulated heavy duty cable.
vii) Ameter 0-400 amps with suitable CT's -01 No
viii) Voltmeter 0-500 Volts-01 No
Note: Make of the Panel shall be L & T , Havells, Standard, C & S confirming to IS 8623 and IEC Pub-439-3(1990) or their approved manufacturer.
M & L for cutting through existing bitumenous road/PCC/floor of approx size width 500mm and depth 600 along cross section of the road for laying of GI pipe/ RCC pipe for encasing of cable or laying of CI/GI pipe line. After laying, repairing of the road to match with the the original finishing by PCC 1:3:6 type C-1 using 20mm graded coarse aggrgates complete all as specified and as directed.
Supply, install, testing and commissioning of Bobbin Wound Pressure Sand Filter, vertical with suitable vertical support, foundation etc as per OEM recommendations for removing turbidities and suspended impurities of swimming pool water in recirculation as well as to up water. The pressure filters shall be suitable for operating pressure 2.5 Bar and made out of fibre glass reinforced polyester resin , totally anticorrosive and fitted with collector arms and diffuser made from Unplasticised PVC and polypropylene , resistant to salt water having filter bed height not less than 1.0m and 125mm dia inlet/outlet connections and other specifications as apended below, including supply and fix suitable frontal valve connections with single filter 5 valve battery system 125mm connections as per OEM recommendations of makes listed in Appendix 'C' complete all as specified and directed. :-
(a)Flow rate = 100 m³/hr
(b)Filteration rate = upto 20Ltr/Sec/m²
(c)Working pressure = 2.5 Kg/Sq.cm.
(d)Filter dia not less than 1800 mm (4 Nos for main pool & 2 Nos for diving pool), the filter media as per OEM specifications suitable for swimming pool requirements, shall be prefilled during commissioning and the frontal valve shall be as per OEM specification/recommendations and shall be suitable for the mode operations such as Filteration, Rinsing, backwash, Bypass and Draining.
(e)MOC: Polyster Resin Bobbin with Fibre Glass Filament winding
Note :- The cost of Chemicals like TCCA-90, Sodium Bisulphate, Copper Sulphate, sodium carbonate, DCCNa etc required for filteration during commissioning of the Plant are deemed to be included in the Unit rate quoted by the Contractor against this item. Complete water circulation/filteration system shall be tested at 6kg/sqcm pressure for 24 hours before closing the finishing of the exposed fittings and pipes and only after ensuring leak proof and no head loss of pressure the excavated portion shall be finished and the test certificate in this respect shall be recorded.
Supplying, fixing, testing and commissioning of Re-circulating Pump, single stage, horizontal, centrifugal, Self-Priming monoblock pumps incorporating C.I. casing and frame, stainless steel shaft, bronze impeller directly coupled to TEFC induction motor, 1500 rpm, 50 Hz AC, IP-54 protection, class F insulated, hydraulically and dynamically balanced to give vibration free operation, with mechanical seal arrangement, fixed on a base plate with suitable vibration eleminator pads complete all as specified & as directed with following parameters for main pool:- . Note: Out of qty 04 Nos as per Col 3 , three pumps will be working at a time and one pump will remain standby.
(a) Pump shall have inbuilt Hair & Lint Strainer
(b) Pump shall have Flow Rate of 70 m³/hr each
(c) Head - 22 mtrs.
Supplying, fixing, testing and commissioning of Re-circulating Pump, single stage, horizontal, centrifugal, Self-Priming monoblock pumps incorporating C.I. casing and frame, stainless steel shaft, bronze impeller directly coupled to TEFC induction motor, 1500 rpm, 50 Hz AC, IP-54 protection, class F insulated, hydraulically and dynamically balanced to give vibration free operation, with mechanical seal arrangement, fixed on a base plate with suitable vibration eleminator pads complete all as specified & as directed with following parameters for diving pool:- Note: Out of qty 03 Nos as per Col 3 , two pumps will be working at a time and one pump will remain standby.
(a) Pump shall have inbuilt Hair & Lint Strainer
(b) Pump shall have Flow Rate of 90 m³/hr each
(c) Head - 22 mtrs.
Supply, Lay & Testing Unplasticised PVC pipes(UPVC) confirming to IS 4985:2000 of pressure rating 10 kgf /sqcm (including short lengths), with & including S&F necessary pipe fittings such as bends, elbows, unions, tees, reducing tees, adoptors, sockets, plugs, hose clips etc. and fixing to walls, ceilings or in floors etc, complete with saddles (snap clips), wall clips, hooks, protective mild steel tube sleeves and cutting through walls, floors and their making good or laying in trenches complete all as specified & directed of following sizes:-
(a) Pipe OD 250 mm
(b) Pipe OD 225 mm
(c) Pipe OD 200 mm
(d) Pipe OD 160 mm
(e) Pipe OD 150 mm
Supply, Lay & Testing Unplasticised PVC pipes(UPVC) of OD 125mm, confirming to IS 4985:2000 of pressure rating 6 kgf /sqcm, (including short lengths), with & including S&F necessary pipe fittings such as bends, elbows, unions, tees, reducing tees, adoptors, sockets, plugs, hose clips etc. and fixing to walls, ceilings or in floors etc, complete with saddles (snap clips), wall clips, hooks, protective mild steel tube sleeves and cutting through walls, floors and their making good or laying in trenches complete all as specified & directed.
Supply, fixing and testing in position MS body, Wafer type, Butterfly Valve PN 1.0 confirming to relevent IS, suitable for fixing to UPVC water pressure pipe including rubber gaskets, nuts, bolts, washers, and all required fittings all as specified and directed suitable for fixing to UPVC water pressure pipes of the following sizes:-
(a) Pipe OD 250 mm
(b) Pipe OD 200 mm
(c) Pipe OD 160 mm
(d) Pipe OD 125 mm
Supply, laying, jointing & testing ERW Steel Pipes conforming to IS-3589 (1981), thickness 6.0 mm, GR-330 including specials (fittings) complete all as specified & directed of following sizes:-Make: (JINDAL/ SURYA/SWASTIK)
(a) Pipe dia 250 mm with fittings
(b) Pipe dia 200 mm with fittings
(c) Pipe dia 150 mm with fittings
(d) Pipe dia 125 mm with fittings
Supply, fixing & testing in position MS body, Wafer type, Butterfly Valve PN 1.6, with nuts, bolts, 3 mm thick rubber gaskets etc. conforming to IS complete all as specifed & as directed of following sizes:-
(a) 250 mm nominal dia
(b) 200 mm nominal dia
(c) 150 mm nominal dia
(d) 125 mm nominal dia
Supply & fix sluice valve of size 150mm dia bore, cast iron body both ends flanged as per IS 14846 and drilled with stainless steel spindal, iron wheel head as per pressure rating PN 1.0, class 1, ISI marked complete alongwith nuts, bolts, washers, gasket etc complete all as specified and as directed. all as specified and as dirtected.
Supply, fixing & testing in position MS body, 125 mm nominal dia, check valve (NRV) (PN 1.0), conforming to IS, with nuts, bolts, 3 mm thick rubber gaskets etc, complete with testing as per direction of Engineer-in-charge and all as specified & as directed.
Supply and fix in position Foot valve, MS body, 150 mm dia, confforming to IS complete all as specified and directed.
Note for Items 2.72 to 3.00 here in above : All fittings (ERW/MS/UPVC) such as Short pieces, Tees, Reducers, Bends, End Plates, Flanges etc required for successful installation and commissioning of Filtration system are deemed to be included in the unit rate qouted by contractor.
M & L for fixing Main Drain (Pool Drain) grating in SS, complete of suitable size 400x400mm complete with all relevant fittings & accessories complete all as specified and directed.
Supply & fix bottom inlet ( floor inlet), white ABS plastic bottom inlet nozzel for concrete with SS screws of capacity 5000Litres/ Hour & adjustable flow of makes listed in Appendix 'C' complete all as specified and directed.
Supply only Pool Maintenance Equipments as mentioned here-in-under of makes listed in Appendix 'C' complete all as specified and directed :-
(a) PE extruded Vaccum Hose 30 Mtr x ½"
(b) Ribbed Telescopic pole 0.8mm thick 2x2400mm
(c) Shallow Net / deep bag leaf net
(d)Curved Brush
(e)18" Standard Wall Brush (with aluminum handle)
(f) Chlorine test kit with coloured ample complete with all testing fitments and OT solution in Rexene finish box
(g) Electronic PH test kit. Make:RMCO
Supply, installing, testing and commissioning, Pool ionization system with model: PP-10, Technical Specification - Ionizer system- Ion Chamber 4 Nos with 8 pairs per cell of silver +copper electrodes in Each chamber with 4 inch inlet & outlet with the following specifications and accessories of Make: Ion Exchange or equivalent as approved:-
(a) Diameter not less than 300mm
(b) Height not less than 300mm
(c) FRP Ion Chamber 2 Nos with 8 pairs per cell 4 inch I/O FRP body - silver+copper electrodes in each chambers
(d) Silver/copper electrodes in each chamber
(e) Control panel & control unit with voltage and LED display meters
(f) Automatic polarity reversal serve with indication cables upto 3mtr to connect with chambers
(g) Inlet/Outlet Header line for ionizer -common header line -4 inch - refer schematic drawing attached for your reference
(h) Area to be fixed for ionization 8Feet x 8Feet in series with common header line for inlet & outlet
(j) Chamber inlet/outlet 4 inch
(k) Maximum pressure-2.5-3.0Kg/Sqcm with piping header line, flange, bolting inclusive of installation & commissioning of system
(l) 8 pairs per cell of silver+copper electrodes each chamber with combination of silver copper rod 32 Nos, piping, cabling & installation, commissioning etc complete
Supply & Fix High power under water light fittings IPX8 Protection LED not less than 55 watts (57VA), 12 V AC complete with all accessories consisting suitable niche for concrete pools along with 2.5m, 1.5Sqmm twin core copper cable and OEM branded PVC flexible water proof conduit upto the deck box including suitable PVC deck box all as directed all as per the makes listed under Appx 'C'. . . Note: Conduit and niche shall be fixed during concrete and light fittings wiring and all accessories shall be connected /fixed with water proof joints, sealants etc complete all as directed.
Supply, install, test and connect out door type, IP 65 protection control gear box for under water lights made out of 1.6mm thick MS sheet supported with suitable angle iron frame work duly grouted on floor suitable for housing and including supply and fix the following in the control gear box complete including all internal wiring /connections all as directed:-
(a) Transformer 600VA, 230/12 V, 50 Hz: 03 Nos
(b) MCB TPN 30A, 10KA: 01 No as incomer
(c) Copper bus bar 63 A rating for 3 Phase and neutral duly insulated with proper colour coding as per standard specifications and Din channel for fixing the MCBs of incoming and outgoing feeders. The bus bar shall be connected for distribution of the out put of each transformer.
(d) MCB SPN 32 A, 10KA : 03 Nos ( for the input control of each transformer)
(e) MCB SPN 6 A, 10KA : 30 Nos
(f) Indicator lamps LED type for RYB: 03 Nos
M & L for submain wiring 2 runs of 2.5 sqmm FRLS copper cable PVC insulated in and including heavy duty PVC conduit and all conduit fittings duly concealed in wall/floor etc. along with one run of 2.5 sqmm copper cable PVC insulated as in earth continuity conductor all all as directed and connecting up complete. . . . Note: Conduit shall be sealed with water proof sealants for all joints complete as the submain in for pool light connections.
Supply and lay, connect the complete UPVC pipe as per IS 4985-2000, class 4 (PN) 8kgf/Sqcm, 40mm dia on wall, floor or in trench including all fittings and fixtures all as doirected.
Supply and lay, connect the complete UPVC pipe as per IS 4985-2000, class 4 (PN) 8kgf/Sqcm, 25mm dia on wall, floor or in trench including all fittings and fixtures all as doirected.
Supply and fix PVC heavy duty gate valve 40mm dia ISI marked all as specified and as dirrected.
Supply and fix PVC heavy duty gate valve 25mm dia ISI marked all as specified and as dirrected.
Supply only suction sweeper consisting of the following:-
(a) Heavy duty stainless steel SS 3.4 grade) vacuum head of size not less than 900mmx450mm with suitable best quality nylon brush, suitable rollars all as directed.
(b) Heavy duty MS trolley with suitable heavy duty nylon wheels, handle for pulling suitable for housing and supply and fix mono block mud pump with 3 phase 3 HP motor, suitable DOL starter alongwith 100 M of 2.5sqmm 4 core flexible cable, duly coiled in and including suitable spool all as directed.
(c) Nylon rope 25mm dia 40m long
VADERAS INTERIORS AND EXTERIORS
K R TRADERS
M.R.Mutha Engineers
Dhariya Construction Pvt. Ltd.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid